Pelco Manual C1402M-B (2/98) 5 1.0 GENERAL CAUTION: This device is designed to operate at 24 volts AC power. Input voltage must not exceed 28 volts or drop below 22 volts or else DAMAGE TO THE MOTORS WILL OCCUR. Should you need technical assis- tance, please call (800) 289-9100.
6 Pelco Manual C1402M-B (2/98) 2.0 DESCRIPTION The SB26 is a discreet surveillance, low profile, hemisphere dome for CCD type cameras designed for ease of installation, relocation, and service in fixed ceilings or standard 2' x 2' (.61 m x .
Pelco Manual C1402M-B (2/98) 7 2.1 MODELS SB26 Drop ceiling discreet surveillance enclosure with black opaque lower dome with 1 f-stop light loss and all aluminum back box which mounts above the ceiling. (Camera mount supplied.) (UL) SB26-1 Same as SB26 except supplied with clear viewing slot for virtually zero light loss.
8 Pelco Manual C1402M-B (2/98) 3.0 INST ALLA TION Save the shipping box and any inserts in case the unit must be returned for credit or repair . 3.1 CONDUCTOR AND CABLE REQUIREMENTS (ALL MODELS EXCEPT SB26) A minimum of 12 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power .
Pelco Manual C1402M-B (2/98) 9 Figure 1. SB2600 Wiring Diagram.
10 Pelco Manual C1402M-B (2/98) Figure 2. SB2600-SL Wiring Diagram.
Pelco Manual C1402M-B (2/98) 11 Figure 3. SB2600SL-PP Wiring Diagram.
12 Pelco Manual C1402M-B (2/98) Figure 4. SB2600-PP Wiring Diagram.
Pelco Manual C1402M-B (2/98) 13 3.3 MOUNTING INSTRUCTIONS Handle the lower dome with care so as not to scratch or get fingerprints on the viewing window . Determine the type of mounting desired. The enclosure can be mounted in a fixed ceiling, or completely replace a standard 2' x 2' (.
14 Pelco Manual C1402M-B (2/98) 3.3.2 Dropped Ceiling, Tile Replacement Mounting To mount the enclosure into a dropped ceiling grid, perform the following steps (refer to Figure 6): 1. Determine the location for mounting the enclosure and remove the appropri- ate ceiling tile.
Pelco Manual C1402M-B (2/98) 15 3.3.3 Camera/Lens Installation Install the camera/lens that you have selected for use with the SB2600 Series dome as follows: 1.
16 Pelco Manual C1402M-B (2/98) 3.4 CONNECTOR ASSEMBL Y Assemble the connector parts according to the instructions below . Detail B, below , reflects the pin arrangement specific to all SB26/SB2600 Series. Refer to Figure 10 during assembly . For best results use an AMP style crimper when making the wire to pin connection.
Pelco Manual C1402M-B (2/98) 17 3.5 J-BOX INST ALLA TION For installations requiring full plenum rating, perform the following step: Installations Requiring Conduit When conduit must be run to the enclosure back box: 1. Attach the provided J-box to the top of the enclosure back box as shown in Figure 1 1 using the supplied 6-32 screws.
18 Pelco Manual C1402M-B (2/98) Figure 1 1. Attachment of J-Box to Back Box for Plenum Applications.
Pelco Manual C1402M-B (2/98) 19 3.6 ADJUSTMENTS To adjust the pan limits, perform the following steps. Refer to Figure 12 for limit stop locations. Factory pan limits are set at 0-355 ° , tilt limits are set at 0-90 ° (horizontal to vertical). To adjust limit stops, perform the following steps: 1.
20 Pelco Manual C1402M-B (2/98) 4.0 MAINTENANCE Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic.
Pelco Manual C1402M-B (2/98) 21 5.0 EXPLODED ASSEMBL Y DIAGRAMS Refer to Figure 13 for an exploded assembly diagram of the SB26 Enclosure, Figures 14 and 15 for the SB2600 Series Pan/Tilt, and Figure 16 for the SB26 fixed mount. Figure 13. SB26 Exploded Assembly Diagram T able A.
22 Pelco Manual C1402M-B (2/98) Figure 14. SB2600 Series Pan/T ilt Exploded Assembly Diagram.
Pelco Manual C1402M-B (2/98) 23 T able B. SB2600 Series Pan/T ilt Exploded Assembly Parts List Item No. Quantity Description Part Number 11 Bracket, drive mount 25004103COMP 2-4 - Not Used 51 Slip rin.
24 Pelco Manual C1402M-B (2/98) 46 1 Bracket, pan preset potentiometer 8104012COMP 47 1 Gear, pan preset potentiometer 90010020 48 2 Ring, snap 15510000 50 1 Support, lens 8144006COMP 51 1 Bracket, re.
Pelco Manual C1402M-B (2/98) 25 Figure 15. SB2600 Hardware Exploded Assembly Diagram.
26 Pelco Manual C1402M-B (2/98) T able C. SB2600 Hardware Exploded Assembly Parts List Item No. Quantity Description Part Number A4 Spacer , 1/4" O.D. x 1/8" L, #6 clear SP A8500 B1 0 Nut, hex 6-32 SS ZH6-32NUTSH C2 Screw, 8-32 x 3/8", hex hd, m/s, SS ZH8-32X.
Pelco Manual C1402M-B (2/98) 27 Figure 16. SB26 Fixed Series Exploded Assembly Diagram.
28 Pelco Manual C1402M-B (2/98) T able D. SB26 Fixed Series Exploded Assembly Mechanical Parts List Item No. Quantity Description Part Number 11 Bracket, drive mount, upper 25004103COMP 21 Adapter bra.
Pelco Manual C1402M-B (2/98) 29 6.0 SPECIFICA TIONS MECHANICAL Construction Pan/tilt: Aluminum Back box: Aluminum Lower dome: Acrylic hemisphere with distortion free viewing window; rotates with the pan/tilt/camera/lens. Max. Camera/Lens Length: (Including BNC connector): 12.
30 Pelco Manual C1402M-B (2/98) Figure 17. SB2600 Dimension Drawing GENERAL Environment: Indoor Temperature Range: 14 ° to 122 ° F (-10 ° to 50 ° C) Dimensions: See Figure 17 Rating: NEMA 1 (Design and product specifications subject to change without notice.
Pelco Manual C1402M-B (2/98) 31 NOTES.
32 Pelco Manual C1402M-B (2/98) 7.0 WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved.
Een belangrijk punt na aankoop van elk apparaat Pelco SB2600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco SB2600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco SB2600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco SB2600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco SB2600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco SB2600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco SB2600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco SB2600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.