Installation and Operation Instructions for MegaTherm Pool Heating Boiler Model MT Sizes 2000-5000 FOR YOUR SAFETY : This product must be inst alled and serviced by a professional service technician, qualified in hot water boiler installation and maintenance.
Page 2 Pentair Water Commercial Pool and Spa T ABLE OF CONTENTS SECTION 1. General Information 1A. Introduction ................................................... 3 SECTION 2. Installation 2A. Boiler Placement ........................................
MegaTherm Commercial Pool Heating Boiler Page 3 SECTION 1. General Information IMPORTANT WARNING: The MegaTherm Model MT commercial pool boilers must be used with potable water only. For pools containing salt water, a specially equipped boiler must be used.
Page 4 Pentair Water Commercial Pool and Spa All boilers must be installed on a non-combustible floor. Under no circumstances can boilers be installed on carpeting. The National Fuel Code allows a boiler to be placed on other than a non combustible surface when such an installation complies with the local codes.
MegaTherm Commercial Pool Heating Boiler Page 5 2B-2. Venting 1. Model MT boilers have built-in draft diverters for natural draft operation and must not be connected into any portion of a mechanical draft system under positive pressure.
Page 6 Pentair Water Commercial Pool and Spa 4. Liquified petroleum is heavier than air. Therefore, the pool boiler should not be installed in pits or other locations where gas could accumulate. The boiler should be located a safe distance from LP gas storage and filling equipment.
MegaTherm Commercial Pool Heating Boiler Page 7 Arrangement of gas train components for on-off firing are shown schematically in the Gas Piping Diagram (see Figure 6).
Page 8 Pentair Water Commercial Pool and Spa Therefore, the temperature difference between the inlet and out pipes will be so small as to be difficult to sense by touching the two pipes. 2I. Boiler By-Pass Piping All Model MT pool boilers are equipped with an automatic flow control valve.
MegaTherm Commercial Pool Heating Boiler Page 9 pool. If this condition exists, follow this procedure to adjust the switch: 1. With the boiler on, the filter pump running and the filter clean, slowly increase the pressure setting until the boiler shuts off.
Page 10 Pentair Water Commercial Pool and Spa 3A-3. Hi-Limit Checkout After running the boiler for a long enough period to bring the water temperature within the range of the hi-limit, slowly back off the high limit setting until the unit shuts off. The main burners should re-ignite when the hi-limit is turned back up to its original setting.
MegaTherm Commercial Pool Heating Boiler Page 11 3F. Time Clock Operation During the initial warm-up period, the boiler must run continuously. Therefore, remove all time clock stops until the pool water reaches a temperature of at least 70 o F.
Page 12 Pentair Water Commercial Pool and Spa SECTION 4. Maintenance 1. At start-up and every six (6) months thereafter, the pilot and main burner flame should be observed for proper performance (see Figures 9 and 10; see attached lighting and shutdown instructions for proper pilot flame pattern).
MegaTherm Commercial Pool Heating Boiler Page 13 SECTION 5. T roubleshooting and Analysis of Service Problems 1. For proper service and problem diagnosis of the boiler and system, the following tools are required: a. Gas pressure test kit with range from zero to 14" W.
Page 14 Pentair Water Commercial Pool and Spa SECTION 6. Conversion of Model MT Pool Boilers From Indoor to Outdoor Models Please read the following instructions with Figure 11. Figure 12 shows the conversion completed. Please follow the instructions in their numerical order, failure to do this will cause problems on assembly.
MegaTherm Commercial Pool Heating Boiler Page 15 Figure 12. Outdoor Parts. Referenced on page 14..
Page 16 Pentair Water Commercial Pool and Spa SECTION 7. Parts Description and Order Numbers I=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted. K ey Size Size Size Size Size Size Size No. Description 2000 I 2450 I 3050 I 3500 I 4050 I 4500 I 5000 I 2200 E 2800 E 3200 E 3600 E 4000 E 4500 E 1.
MegaTherm Commercial Pool Heating Boiler Page 17 Figure 13. Parts Identification. *Indoor parts only **For tiles, see Figure 15..
Page 18 Pentair Water Commercial Pool and Spa I=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted. K ey Size Size Size Size Size Size Size No. Description 2000 I 2450 I 3050 I 3500 I 4050 I 4500 I 5000 I 2200 E 2800 E 3200 E 3600 E 4000 E 4500 E 22.
MegaTherm Commercial Pool Heating Boiler Page 19 Figure 14. Built-in Automatic Control Valve. Rod retainer 101337 Spring shaft S00196 Spring Spring guide S00116 Spring Valve disk 101335 Main casting S-20002 IN - Return from the pool To heater inlet From heater outlet OUT - Supply to the pool K ey Size Size Size Size Size Size Size No.
Figure 15. Tile Assembly. © 2006 Pentair W ater Pool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins Ave.
Een belangrijk punt na aankoop van elk apparaat Pentair MT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pentair MT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pentair MT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pentair MT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pentair MT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pentair MT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pentair MT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pentair MT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.