User Manual CS-114A Read this guide thoroughly and follow the installation and operation proce- dures carefully in order to prevent any damage to the units and/or any de- vices that connect to them. This package contains: M 1 Master View CS-114A KVM Switch M 1 Power Adapter M 1 User Manual If anything is damaged or missing, contact your dealer.
Overview The Master View CS-114A 4 Port KVM (Keyboard, Video, Mouse), Switch is a control unit that allows acces s to four computer systems from a single PS/2 keyboard, PS/2 mous e, and monitor console in a cost effecti ve manner.
Hardware Requirements Console M One VGA, SVGA , or Multisync moni tor capable of the highes t resolution that you wi ll be using on any PC i n the installati on M One PS/2 Mouse M One PS/2 Style K eyboard Computers The following equipment must be ins talled on each PC that is to be connected to the system: M A VGA, SVGA or Multisync card.
Introduction Front View 1. On Line and Selected LEDs: M When an On Line LED is lit, it indi cates that the computer at- tached to the corresponding port i s up and running. M When a Selected LED i s lit, it indi cates that the port it corre- sponds to is the currentl y selected port.
Rear View 1. Power Jack The CS-114A is des igned to be non-powered (external power is not required - its operation power c omes from the computers). In general, the only time that external power is re.
Installation Before You Begin Single Stage Installation The most basic installati on is a Single Stage ins tallation, in whi ch no additional Mas ter View ’ s are dai sy chained down from the first uni t. The Master View CS-114A design also allows additional uni ts to be dai sy chained down to two or three levels.
Two Stage Installation To control even more computers, up to four additi onal Master View CS-114A units can be cas caded from the CPU ports of the First Stage unit. The cascaded Master V iews that connect back to the First S tage unit are considered Second Stage units .
Three Stage Installation The procedures for setting up a three stage ins tallation are essenti ally the same as for a two stage installation. With a three stage setup, however, as many as 64 c omputers can be control led in a compl ete installati on. Note: Master View units cannot be cascaded bey ond the third level .
Operation Powering Off and Restarting If it becomes necessary to Power Off one of the Master View units , before starting it back up you mus t do the following: 1. Shut down all the computers that are attac hed to it. If the unit is operating under external power, unplug the power adapter c able.
Hotkey Port Selection Hotkey Port Selection allows you to select the acti ve computer directly from the keyboard. The Master View CS-114A prov ides the following Hotkey Port S election features: M Sel.
To access a computer attached to a Second S tage unit, key in a two di git number for the Port ID (press and release eac h number separatel y). The first digit represents the CPU Port number (1 - 4), .
M Last/Next Mode: Last/Next mode enables you to easily switc h from the currently active computer to the previous or next avai lable computer in the instal lation. There are two methods of invoking Last/Nex t Mode: Basic Mode, and Quick Mode.The choice of mode is made with DIP Switch 4.
Hotkey Summary Table Activity DIP Switch Combination Port Select 3 On [Alt+Ctrl+Shift] Port ID [Enter] 3 Off [LCtrl+RCtrl] Port ID [Enter] Auto Scan 3 On [Alt+Ctrl+Shift] 0 [Enter] 3 Off [LCtrl+RCtrl].
DIP Switch Settings Note: The default position for all s ettings is ON. Scan Time - Switch 1 & 2: Seconds Switch1 Switch2 5O n O n 10 Off On 20 On Off 40 Off Off Hotkey Select - Switch 3 / Last/Next Mode Select - Switch 4: See the Hotkey Summary Table on page 12.
Troubleshooting Symptom Possible Ca us e Action Keyboard Not Responding 1 Loose c ables. Check all key board cable connecti ons to make sure they are c ompletely seated i n their sockets. Keyboard needs to be reset. Unplug the keyboard from the Console Keyboard Port, then plug it back i n.
Video Problems Resolution and/or Bandwidth set too high. This unit supports VGA, SVGA, Mult isync, and XGA (interlaced), with resol utions of up to 1920x1440. The maximum bandwidth is 180 MHz. Cable quality not good enough. We strongly recommend that y ou use high quality cables 1 The unit is designed to work with AT and PS/2 k eyboards.
Een belangrijk punt na aankoop van elk apparaat ATEN CS-114A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ATEN CS-114A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ATEN CS-114A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ATEN CS-114A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ATEN CS-114A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ATEN CS-114A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ATEN CS-114A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ATEN CS-114A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.