GO2 GOS2G217 or 2U

Page 1 of 2 2' x 2' Recessed Fluorescent, High Performance Louver Static or Air Supply/Return, 2 Lamp T8 or 2U

  • GO2 evenly illuminates horizontal and vertical surfaces and is low in brightness.
  • 80.5% efficient with a 1.7 space mounting ratio (2 T8 lamps)
  • 79.5% efficient with a 1.6 space mounting ratio (2 T8U lamps)
  • 94% reflective flat white powder coated louver.
  • 94% reflectance Miro TM reflector system.
  • 5" deep body.
  • One piece housing.
  • Black exterior for cooler ballast operating temperature.
  • Built-in earthquake clips (patent no. 5,072,344).
  • Spring loaded latches.
  • 18 gauge steel hinges.
  • Construction to meet NYC Code or Chicago Plenum requirements is available.
  • Manufactured in USA
Philips GO2 — GO2 GOS2G217 or 2U diagram (page 1)
Afb. 1 · GO2 GOS2G217 or 2U

Mounting Methods Dimensions

G

exposed T-grid ceiling. T

exposed slot T-grid ceiling.

Philips GO2 — Mounting Methods Dimensions diagram (page 1)
Afb. 2 · Mounting Methods Dimensions
Philips GO2 — Mounting Methods Dimensions diagram (page 1)
Afb. 3 · Mounting Methods Dimensions
Philips GO2 — Mounting Methods Dimensions diagram (page 1)
Afb. 4 · Mounting Methods Dimensions

1/4" max.

1-1/2" max. 1-7/8" max.

9/16", 15/16" or 1" 24"

drywall kit.

Philips GO2 — Mounting Methods Dimensions diagram (page 1)
Afb. 5 · Mounting Methods Dimensions

Air supply slots (GOA only)

Drywall Kit (See Options)

2" x 2-1/2" access plate with two K.O.s (7/8" dia.) Order Catalog Number: FK92X4.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 a Philips Group Section 1/Folio A10-15

Lightolier is a Philips group brand

Show 12 more labels / short text on this page
5" (127mm) · 24" (610mm) · 5" (127mm) · 9/16" 24" · 24" (610mm) · Support (by others) · Type “G” Fixture · 23-7/8" (606mm) · Drywall (by others) · 15-11/16" (398mm) · 5" (127mm) · 05/08
Page 2 of the Philips GO2 user manual — Lightolier is a Philips group brand
Pagina 2 · klik om te vergroten
Pagina 2

GO2 GOS2G217 or 2U

Page 2 of 2 2' x 2' Recessed Fluorescent, High Performance Louver Static or Air Supply/Return, 2 Lamp T8 or 2U

Model No. GOS2G217UNVC2 LER = FP - 65.5 IW - 30.28 BF - 0.88 Comparative yearly lighting energy cost per

Model No. GOS2G22UUNVC5 LER = FP - 73.9 IW - 46.0 BF - 0.77 Comparative yearly lighting energy cost per

1000 lumens = $3.66 Report Number: G2008145 Catalog Number: GOS2G217UNVC2 Lamp: (2) F17/TL835/ALTO/PLUS Luminaire: GO2 2'X2' with 6 cell louver. Ballast: Advance IOP-2P-32-SC Report is based on 1400 Lumens per lamp. Efficiency: 80.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.7 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.000 21.000

CANDELA DISTRIBUTION

1000 lumens = $3.25? Report Number: G2008126 Catalog Number: GOS2G22UUNVC5 Lamp: (2) FBO/835XP/ECO Luminaire: GO2 2'X2' with 6 cell louver. Ballast: Advance IOP-2P-32-LW-SC Report is based on 2775 Lumens per lamp. Efficiency: 79.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.6 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.000 21.000

CANDELA DISTRIBUTION

Philips GO2 — CANDELA DISTRIBUTION diagram (page 2)
Afb. 6
Philips GO2 — CANDELA DISTRIBUTION diagram (page 2)
Afb. 7

0.0 45.0 90.0 FLUX

0.0 45.0 90.0 FLUX

0 755 755 755

0 1646 1646 1646

5 761 765 768 73

5 1644 1691 1720 162

15 719 825 950 236

15 1528 1721 1814 481

25 640 915 1094 408

25 1341 1628 1864 750

35 536 857 979 503

35 1111 1477 1833 925

45 403 663 657 466

45 838 1239 1355 899

55 271 383 283 307

55 561 779 775 651

65 157 153 106 149

65 322 359 202 318

75 80 86 75 85

75 165 172 156 174

85 22 24 21 26

85 46 47 47 53

COEFFICIENTS OF UTILIZATION –

90 3 3 2

COEFFICIENTS OF UTILIZATION –

90 8 7 4

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 717 25.6 31.8 00-040 1220 43.6 54.2 00-060 1993 71.2 88.4 00-090 2253 80.5 100.0 90-180 0000 0.0 000.0 00-180 2253 80.5 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 1391 25.1 31.6 00-040 2317 41.8 52.5 00-060 3867 69.7 87.7 00-090 4411 79.5 100.0 90-180 0000 0.0 000.0 00-180 4411 79.5 100.0

1 89 85 82 80 78 76 77 75 74 2 82 76 71 71 68 64 69 66 63 3 75 67 61 64 59 55 62 58 54 4 69 60 52 57 52 48 55 51 47 5 64 54 47 52 46 42 50 45 41 6 59 49 42 47 41 37 46 40 37 7 55 45 38 43 37 33 42 36 33 8 51 41 34 39 33 29 38 33 29 9 48 37 31 36 30 27 35 30 26 10 45 34 28 33 28 24 33 27 24

1 88 84 81 79 77 75 76 74 72 2 80 75 70 70 66 63 68 65 62 3 74 66 60 63 58 54 61 57 53 4 68 59 53 56 51 47 54 50 46 5 63 53 47 51 45 41 49 44 41 6 58 48 41 46 40 36 45 40 36 7 54 44 37 42 36 32 41 36 32 8 50 40 34 38 33 29 37 32 29 9 47 37 30 35 30 26 35 30 26 10 44 34 28 33 27 24 32 27 24

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2002. 3294. 3265. 55 1660. 2346. 1734. 65 1305. 1272. 881. 75 1086. 1167. 1018. 85 887. 968. 847.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4164. 6156. 6733. 55 3436. 4772. 4747. 65 2677. 2985. 1679. 75 2240. 2335. 2118. 85 1854. 1895. 1895.

Ordering Information Explanation of Catalog Number. Example: GOS2G22UUNVC5

GO2 Series Body StyleA =Air Supply S =Static
Ceiling TypeG = Grid
OptionsAdd appropriate suffix

(lay-in T bar) T= Slot grid or

Voltage120, 277 or UNV =120-277
to catalog no., ie(C)

two-directional concealed T (see options)

Lamp Type/ Fixture Length:

Ballast Type:

17= 2' T8 2U= 2' U T8 (Nominal 24") GO Standard GO2

Ballast

GC For NYC Code – I.B.E.W. Manufactured

GN For NYC Code – Local 3 Manufactured

Options/Accessories Plaster Frame: Catalog Number: PF22. Radio Interference Filter: To order one RIF per fixture; SUFFIX: R.

Specifications (continued) Materials: Chassis parts are die-formed code gauge cold rolled steel. Side rails hemmed over and housing ends turned-in for safe handling. Reflector is 94% reflective aluminum. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel. Rust preven- tative undercoating. Louver–94% reflective flat white powder coat. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

To order one RIF per ballast; SUFFIX: B. Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C. Electrical Wiring Options: Consult factory. Air Closure Strip: SUFFIX: ACS4 (factory installed). Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: C.

Specifications Performance: In an installation of 2 lamp T8U luminaries in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .84. Air Handling (GOA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

Job Information Type:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 a Philips Group Section 1/Folio A10-15

Lightolier is a Philips group brand

Show 5 more labels / short text on this page
Fixture · Lamp Quantity · Width · 5½" Deep Body · *Instant Start Standard
Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Philips GO2

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Philips GO2

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Philips GO2 handleiding-pdf

2 pagina's·89 KB·Woonaccessoires·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…