Gebruiksaanwijzing /service van het product FNSW-2400S van de fabrikant Planet Technology
Ga naar pagina of 31
NOVASwitch FNSW-1600S FNSW-2400S 10/100Base-TX Fast Ethernet Smart Switch.
PLANET NOVASwitch series Trademarks Copyright PLANET Technology Corp. 2000. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp.
FNSW-16/2400S User's Manual TABLE OF CONTENTS 1. UNPACKING INFORMA TION ........................................... 5 2. PRODUCT INTRODUCT ION ............................................. 7 2.1 K EY F EATURES ....................................
PLANET NOVASwitch series 5.2 H ALF - AND F ULL -D UPLEX .................................................. 23 5.3 F AST E THERNET ................................................................ 24 5.4 A UTO -N EGOTIATION .............................
FNSW-16/2400S User's Guide 5 1. UNPACKING INFORMATION Thank you for purchasing a PLANET NOVASwitch series Ethernet Switches. Before continuing, please check the contents of the product package.
PLANET NOVASwitch series This page intentionally left blank!.
FNSW-16/2400S User ’ s Guide 7 2. PRODUCT INTRODUCTION NOVASwitch Ethernet Switches are multi-speed, versatile network devices combining both standard and "Big-Pipe" ports under the same hood. 2.1 Key Features • Compliant with IEEE802.3 and 802.
PLANET NOVASwitch series 8 2.2 Front Panel FNSW-1600S Figure 1: Front View of the FNSW-16/2400S 2.2.1 Ports Speed n 100Base-TX All 100Base-TX ports come with auto-negotiation capability.
FNSW-16/2400S User ’ s Guide 9 23 24 19 20 Reset Port Type Cable Type Connector 10Base-T Cat 3, 4, 5 RJ-45 100Base-TX Cat.5 UTP only RJ-45 100Base-FX* 62.
PLANET NOVASwitch series 10 Steady Green 100M Lit to indicate that a valid physical UTP/STP connection exists on that port runs in 100Mbps L OWER ROW OFF 10M Remains off and Link ON to indicate the port runs in 10Mbps Table B: FNSW-2400S Port-LED Functions 2.
FNSW-16/2400S User ’ s Guide 11 2.3.4 RS-232 Console The RS-232 console helps to manage the Switch. Please use the cable with the package. Attach one end to the switch and the other to your PC ’ s COM1 or COM2. Then startup your console program like Windows Hyper Terminal, or ProCOMM with parameter: 19200, n, 8, 1.
PLANET NOVASwitch series 12 This page intentionally left blank!.
FNSW-16/2400S User ’ s Guide 13 3. INSTALLATION The Switch do NOT require software configuration. Users can immediately use any of the features of this product simply by attaching the cables and turning on the power. However, the Console port will helps to have more setting to your Switch.
PLANET NOVASwitch series 14 3.3 Power notes: 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider use an UPS (Uninterrupted Power Supply) for your device.
FNSW-16/2400S User ’ s Guide 15 4. CONSOLE CONFIGURATION On the rear panel, there is one console port for configuring the switch. The attached cable in the packing box is used to connect to PC ’ s RS232C port (COM1, or COM2). Following the instructions below to configure the switch.
PLANET NOVASwitch series 16 There are six options available for the console setup: (1) Trunk / VLAN Setting (2) Port Status (3) Port Setting (4) Factory Setting (5) Redundant Link (6) Save Setting To enter any of the sub-menu, simply follow the instruction and type the number on the command line, and press ENTER.
FNSW-16/2400S User ’ s Guide 17 Default: No Trunk Group in the device. Note: As soon as trunk port enabled, the ports will be grouped as followings: 2-port Trunk: 1 st group: 1 , 3, 5, 7, 9, 11, 13,.
PLANET NOVASwitch series 18 Purpose: Set up the VLAN Group Default: No VLAN Group in the device (all ports in VLAN1) Note: Use Toggle to select VLAN group and “ SAVE ” to make the setting take effect. VLAN setting example 1, Follow the selection to add port 1 to VLAN2.
FNSW-16/2400S User ’ s Guide 19 VLAN3 X X VLAN4 X X 4.3 Port Status Entry: S elect “ 2 ” from < Console Manu> PORT 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A.
PLANET NOVASwitch series 20 Enable port 2 ’ s PAUSE frame support Enetr Port Number ((qq) to quit)>> 2 Select (1)Port Mode (2)Pause (3)Back Pressure>> 2 Select Pause in FDX (1)Enable (2)Disable>> 1 PAUSE frame is used while the devices that connect to the Switch runs in Full-duple mode.
FNSW-16/2400S User ’ s Guide 21 Set up the Factory default value, the system will be Auto Reboot 4.6 Redundant Link Setting Entry: Select “ 5 ” from < Console Manu> Redundant Link on Port-20/Port-19(19 is Backup link) (1)Enable (2)Disable >>1 Purpose: Set up Redundant Link.
PLANET NOVASwitch series 22 This page intentionally left blank!.
FNSW-16/2400S User ’ s Guide 23 5. OPTIMIZING CONFIGURATION 5.1 Prior to Installation Before installing the Switch and connecting network devices, it is important to plan the new network layout.
PLANET NOVASwitch series 24 5.3 Fast Ethernet 100Base-TX and 100Base-FX are called "Fast Ethernet." This is because they use the Ethernet CSMA/CD access rules and data packet structure, but data travels ten times faster (100Mbps) than traditional 10Mbps Ethernet.
FNSW-16/2400S User ’ s Guide 25 5.4 Auto-Negotiation The 100Base-TX ports on the Switch have built-in "Auto- Negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset).
PLANET NOVASwitch series 26 5.6 Sample Application The optimal application for the Switch, no matter with the extension module or not, is as a "big pipe" backbone interconnecting file servers with bandwidth-hungry workgroups, departments, and offices.
FNSW-16/2400S User ’ s Guide 27 6. TROUBLESHOOTING S YMPTOM Link LED does not lit after cable is connected to the port. C HECKPOINT 4 V erify that the other end of the cable is connected to a device that is powered on and on-line .
PLANET NOVASwitch series 28 This page intentionally left blank!.
FNSW-16/2400S User ’ s Guide 29 7. PRODUCT SPECIFICATIONS P RODUCT FNSW-1600S / FNSW-2400S N ETWORK P ORTS 16/24 10/100Base-TX RJ-45 (MDI-X) B UFFER M EMORY 4Mb E XTENSION S LOT 1 open slot (shared with port 16/24 for optional module) M EDIA S UPPORT 100Base-TX Cat.
PLANET NOVASwitch series 30 8. RJ-45 PIN ASSIGNMENT Pin Numbered Ports (MDI-X port) Uplink Port (MDI-II port) 1 Input Receive Data + Output Transmit Data+ 2 Input Receive Data - Output Transmit Data- .
EMFNSWSv1 ISO9002.
Een belangrijk punt na aankoop van elk apparaat Planet Technology FNSW-2400S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Planet Technology FNSW-2400S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Planet Technology FNSW-2400S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Planet Technology FNSW-2400S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Planet Technology FNSW-2400S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Planet Technology FNSW-2400S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Planet Technology FNSW-2400S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Planet Technology FNSW-2400S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.