Power over LAN™ Midspans PD-6006, PD-6012 & PD-6024 6/12/24-Port Models IEEE 802.3af-compliant User Guide Data and Power on a Single Line.
Disclaimer PowerDsine assumes no responsibility or liability arising from the use of Midspans, as described herein, nor does it convey any license under its patent rights or the rights of others. Applications that are described herein for any of theses products are for illustrative purposes only.
PD-6006/12/24 Power over LAN Solutions 3 Cat. No.: 06-6800-056 Contents 1 S AFETY I NFORMATION ............................................................................. 5 1.1 General Guidelines .....................................................
PD-6006/12/24 Power over LAN Solutions 4 Cat. No.: 06-6800-056 Model Numbers Definition PD-60 xx / yyyy / M where : xx represents the number of ports (6, 12 or 24) yyyy establishes the type of input power used, such as: AC ( yy ) , or DC ( yy ) , or both AC and DC ( yyyy ) .
PD-6006/12/24 Power over LAN Solutions 5 Cat. No.: 06-6800-056 1 Safety Information 1.1 General Guidelines You must read the following safety information before carrying out any installation, removal or any maintenance procedure on the Power over LAN Midspan.
PD-6006/12/24 Power over LAN Solutions 6 Cat. No.: 06-6800-056 1.2 Power Cord In the event that the power cord is replaced, the replacement must meet local requirements. U.S.A. and Canada The cord must be UL-approved or CSA certified. The minimum specification for the flexible cord is: • No.
PD-6006/12/24 Power over LAN Solutions 7 Cat. No.: 06-6800-056 2 About the Power over LAN Midspan PowerDsine’s family of Power over LAN Midspans, series 6000, injects power over data-carrying Ethernet cabling.
PD-6006/12/24 Power over LAN Solutions 8 Cat. No.: 06-6800-056 2.2 10/100BASE-TX Ports Definition 2.2.1 Data Input Ports According to the model acquired, the Midspan has 6, 12 or 24 10Base- T/100Base-TX- data input ports, configured in a non-crossover manner (straight-wired).
PD-6006/12/24 Power over LAN Solutions 9 Cat. No.: 06-6800-056 2.3.2 Port Indications One bi-color indicator (green and orange), per port, provides port status: Green indicates that the terminal unit has been identified as "Power over LAN Enabled" and is active and receiving power.
PD-6006/12/24 Power over LAN Solutions 10 Cat. No.: 06-6800-056 Table 2-2: Port Status Indications Port LED Color Port Load Conditions Port Voltage Off Non-active load or unplugged port. Power to the port is disconnected.No DC voltage present on spare pairs.
PD-6006/12/24 Power over LAN Solutions 11 Cat. No.: 06-6800-056 3 Installing the Power over LAN Midspan 3.1 Background Information As shown in Figure 3-1, the Midspan is connected in series to an Ethernet switch/hub. The data outputs from the switch are connected to the Midspan.
PD-6006/12/24 Power over LAN Solutions 12 Cat. No.: 06-6800-056 3.3 Connecting Ethernet Cables The ports on the front panel of the Midspan are configured as "route through" ports for all eight conductors of the RJ-45 connectors. Use Category 5 cabling in making connections.
PD-6006/12/24 Power over LAN Solutions 13 Cat. No.: 06-6800-056 3.6.2 Troubleshooting Guide This paragraph provides a symptom and resolution sequence in order to assist in the troubleshooting of minor operating problems. If the steps given do not solve your problem, do not hesitate to call your local dealer for further assistance.
PD-6006/12/24 Power over LAN Solutions 14 Cat. No.: 06-6800-056 Table 3-1: Troubleshooting Steps Symptom Corrective Steps Is it safe to keep the Midspan running while a port indicator is orange? This is a safe condition. The orange indication is due to: 1.
PD-6006/12/24 Power over LAN Solutions 15 Cat. No.: 06-6800-056 4 Remote Power Management SNMP Remote Management is an optional feature, for monitoring and control of the device. For further details, refer to PowerDsine’s PowerView, Power over LAN™ SNMP Web Manager User Guide, catalog number 06-6910-056.
Part Number: 06-6800-056 Release 1.0 Covered under US Patent 6,473,608 Visit our web site at: www.powerdsine.com For technical support, call: +972-9-7755123 In the USA: +631-756-4680 or 1-877-4-802-3A.
Een belangrijk punt na aankoop van elk apparaat PowerDsine PD-6006 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen PowerDsine PD-6006 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens PowerDsine PD-6006 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding PowerDsine PD-6006 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over PowerDsine PD-6006 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van PowerDsine PD-6006 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de PowerDsine PD-6006 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met PowerDsine PD-6006 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.