Powerware 9355 UPS 10/15 kVA User’s Guide ®.
Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent.
Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standa rds and EU directives: S Harmonized Standards: IEC 62040 - 1 - 1 and IEC 62040 .
Special Symbols The following are examples of symbols used on the UPS to alert you to important information: RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Safety Warnings 5 .............................................
TABLE OF CONTENTS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com ii 9 Operation 65 ........................................................... Control Panel Functions 65 .....................................
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 1 Chapter 1 Introduction The Powerware ® 9355 uninterruptible power supply (UPS) is a true online, double - conversion three - phase system that can be used to prevent loss of valuable electronic information and minimize equipment downtime.
INTRODUCTION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 2 Providing outstanding performance and reliability, the Powerware 9355 UPS’s unique benefits including the following: S Online UPS design with pure sine wave output.
INTRODUCTION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 3 The following options for the Powerware 9355 are available: S Remote Monitor Panel (RMP) The optional RMP provides monitoring of the operational status and alarm condition of the UPS from virtually any location within the facility.
INTRODUCTION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 4.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 5 Chapter 2 Safety Warnings IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions t hat you should follow during installation and maintenance of the UPS and batteries.
SAFETY WARNINGS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 6 Consignes de Sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES CONSIGNES DE SÉCURITÉ IMPORTANTES DANGER! Cet onduleur contient des TENSIONS MORTE LLES.
SAFETY WARNINGS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 7 Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES ESTE MANUAL CONTIENE INSTRUCCIONES DE SEGURIDAD IMPORTANTES PELIGRO Este SIE contiene VOLTAJES MORTALES.
SAFETY WARNINGS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 8.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 9 Chapter 3 UPS Setup This chapter describes: S Equipment inspection S Floor loading and clearances S Unloading the cabinet(s) The instructions are intended for the chief operator/system supervisor, electrical consultants, and installation electricians.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 10 Floor Loading When planning the installation, consider the UPS weight for floor loading. The strength of the installation surface must be adequate for point and distributed loadings.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 11 Unloading the Cabinet(s) The following tools are required for unloading the cabinet(s): S 15 mm wrench or socket S 7 mm nut driver or socket CAUTION The UPS and EBM are heavy ( see page 10).
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 12 2. Remove the four M4 screws securing the stabilizing bracket to the cabinet rear panel and remove the bracket (see Figure 3). Retain the hardware for later use.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 13 NOTE Be sure to support the front and back of the cabinet when rolling it off the pallet to prevent tipping. 5. Slowly roll the cabinet toward the rear of the pallet.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 14 Two-High UPS Cabinet To remove a two - high UPS from the shipping pallet: 1. Remove the M10 bolt securing the vertical bracket to the pallet (see Figure 6).
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 15 4. Repeat Steps 1 through 3 to remove the vertical bracket on the other side. 5. Remove the three M10 bolts securing the rear shipping pad to the pallet and remove the shipping pad (see Figure 8).
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 16 NOTE Be sure to support the front and back of the cabinet when rolling it off the pallet to prevent tipping. 7. Slowly roll the cabinet toward the rear of the pallet.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 17 Selecting an Installation Option You are now ready to install the Powerware 9355 UPS.
UPS SETUP EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 18.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 19 Chapter 4 UPS Installation The Powerware 9355 has the following power connections: S 3 - phase (L1, L2, an.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 20 5. Verify that the UPS battery circuit breaker is in the OFF position (see Figure 11). Battery Circuit Breaker UPS Wiring Access Cover Conduit Landing Plates Figure 11.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 21 10. Verify that the input circuit breaker is in the OFF position (see Figure 12). 11. Remove the input isolation transformer wiring access cover and retain.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 22 NOTE Input neutral must be wired for proper operation. Failure to connect an input neutral will void the warranty. NOTE The Powerware 9355 UPS is a single - feed UPS only.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 23 Ground Figure 13. UPS Terminal Block (3-High Shown) L1 L2 L3 N INPUT L1 L2 L3 N OUPUT N Figure 14.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 24 13. For UPS only installations, replace the UPS wiring access cover and conduit landing plate. For UPS installations with an input isolation transformer, replace the transformer’s wiring access cover.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 25 * * Figure 15. UPS Wiring Diagram.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 26 * * Figure 16. UPS with Extended Battery Modules Wiring Diagram.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 27 * * Figure 17. UPS with Input Isolation Transformer Wiring Diagram.
UPS INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 28.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 29 Chapter 5 Wall-Mounted Bypass Switch Installation This chapter describes installing the wall - mounted bypass switch with the UPS. The wall - mounted bypass switch is a Make-Before-Break maintenance bypass switch.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 30 4. Determine your equipment’s grounding requirements according to your local electrical code. 5. Remove the bypass cabinet front cover (see Figure 18).
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 31 7. Punch holes for the conduit (AC input, UPS output, load connection, and maintenance bypass contact wires) using a Greenlee punch or similar device.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 32 10. Verify that the UPS battery circuit breaker is in the OFF position (see Figure 21). 11. Remove the UPS wiring access cover and one of the conduit landing plates and retain.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 33 12. Hardwire the UPS input terminations. See Table 2 for specifications and Figure 22 for a detailed view of the UPS terminal block.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 34 Ground Maintenance Bypass Contacts TB2 Figure 22.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 35 13. Hardwire the output terminations from the UPS to the bypass cabinet (see Figure 23). Neutral Line 1 Line 2 Line 3 Ground Figure 23.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 36 14. Hardwire the load to the bypass cabinet (see Figure 24). 15. Route the maintenance bypass wires through the conduit to the UPS terminal block (see Figure 22 on page 36).
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 37 17. Wire the AC input to the bypass breaker (see Figure 25). Line 1 Line 2 Line 3 Figure 25. Bypass AC Input Wiring 18.
WALL-MOUNTED BYPASS SWITCH INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 38 Red Wire (open when breaker is open) Bypass Input Black Wire (common) From UPS 1 Output Not Used Not Used Not Used 225A 80A (4X) LOAD Blue Wire (closed when breaker is open) Figure 26.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 39 Chapter 6 Stabilizing the Cabinet NOTE For seismic installations, you MUST order and install a Powerware 9355 U PS seismic kit; do not use the following instructions.
STABILIZING THE CABINET EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 40 4. Continue to one of the following sections: S “Extended Battery Module Installation” on page 43 to install optional EBMs.
STABILIZING THE CABINET EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 41 M4 Screws Figure 29. Stabilizing Bracket with Two Cabinets M4 Screws Figure 30.
STABILIZING THE CABINET EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 42.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 43 Chapter 7 Extended Battery Module Installation NOTE A maximum of 22 battery strings can be ins talled in one configuration, including UPS batteries (4 EBM - 64 models or 3 EBM- 96 models).
EXTENDED BATTERY MODULE INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 44 UPS Battery Connector Rear Ground Strap EBM Battery Circuit Breaker EBM Battery Connector EBM Cable UPS Battery Circuit Breaker Figure 31.
EXTENDED BATTERY MODULE INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 45 8. Remove the top front covers of all cabinets. 9. Install the remaining ground straps between each cabinet (see Figure 32).
EXTENDED BATTERY MODULE INSTALLATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 46.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 47 Chapter 8 Communication This section describes the: S DB - 9 communication port S X - Slot cards S Remote .
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 48 Installing Communication Options and Control Terminals To access and install the communication options and control terminals: 1. Remove the front covers of all cabinets, starting with the top cabinet.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 49 Figure 35. Installing Communication Cables 3.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 50 4. Route the cable(s) to the approximate location of the cover access holes. 5. Connect the cables to the appropriate location. See “Communication Options” on page 51 or “Control Terminals” on page 60 for detailed information.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 51 Communication Options The Powerware 9355 has serial communication capabilities through the DB - 9 communication port or through an X - Slot card in one of the available bays.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 52 The cable pins are identified in Figure 38 and the pin functions are described in Table 3. See Figure 33 on page 47 for serial port location. 3 8 7 9 1 6 2 4 5 Figure 38.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 53 S Industrial Relay Card - is used to indicate the operating status of the UPS using the customer’s monitoring equipment and to connect an optional RMP.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 54 Remote Monitor Panel The optional RMP can be installed to monitor the operation of the UPS from virtually any location within your facility, up to 152.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 55 Mounting Slots (6 places) NOTE Matches mounting holes on a single - or double - gang electrical box. Cable Exit Openings for 1/2” Conduit or Provided Strain Relief (3 places) Dimensions are in mm [inches] Figure 41.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 56 To install an RMP: NOTE If mounting to a hollow wall, secure the enclosure bottom to a wood or metal stud within the wall. Do not use hollow wall anc hors.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 57 6. To check the operation of the RMP, ensure that the UPS is supplying the load via the inverter or bypass. If the indicators on the RMP show the appropriate status, then it is operating correctly.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 58 Industrial Relay Card The IRC uses normally - open or normally - closed dry relay contacts to indicate the UPS status as listed in Table 5. Figure 43 shows an IRC.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 59 Table 5. IRC Wire Terminations IRC Terminal Function Remarks J2-1 NC J2-2 COM Normal mode J2.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 60 Control Terminals The cables should be connected to the control terminals with a mating connector. Input and output terminals have a functional isolation from terminal to terminal.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 61 Remote Emergency Power-off REPO is used to shut down the UPS from a distance. This feature can be used for shutting down the load and the UPS by thermal relay, for instance in the event of room overtemperature.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 62 Relay Output Contacts The UPS incorporates a programmable relay output with potential free contacts for remote alarm indications (see Figure 33 on page 47).
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 63 Table 6. Programmable Signal Inputs Signal Description Disable Bypass Operation If active, the automatic transfer to the static bypass is prevented.
COMMUNICATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 64.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 65 Chapter 9 Operation This chapter contains information on how to use the Powerware 9355, including front panel operation, UPS startup and shutdown, and configuring the UPS for Extended Battery Modules.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 66 The following table shows the indicator status and description. Indicator Status Description On The UPS is operating normally. Green Flashing S The UPS is starting up or is shut down and waiting for power to return.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 67 The following table shows the basic menu structure.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 68 User Settings The following table displays the options that can be changed by the user. NOTE Changes to the output voltage or frequency options should be made before turning on the UPS; otherwise, the changes do not take effect.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 69 Table 8. User Settings (continued) Default Setting Available Settings Description Automatic Battery Tests Enabled/Disabled Enabled automatically runs the battery test once a month.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 70 Initial Startup Startup and operational checks must be performed by an authorized Eaton Customer Service Engineer, or the warranty terms as specified on page 91 become void.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 71 Internal Bypass Startup To start up the UPS in Bypass mode: 1. Verify that the maintenance bypass switch is in the UPS position (see Figure 46 on page 79).
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 72 Normal Mode Startup To start up the UPS: 1. Verify that the maintenance bypass switch is in the UPS position (see Figure 46 on page 79). 2. If an optional isolation transformer is installed, switch the input circuit breaker to the ON position.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 73 Starting the UPS on Battery NOTE Before using this feature, the UPS must have been powered by utility power at least once. To start the UPS on battery: 1.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 74 5. Use the or arrow buttons to select the number of strings according to your UPS configuration:.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 75 UPS Shutdown To shut down the UPS: 1. Press any button on the front panel display to activate the menu options. 2. Press the button on the front panel display and then press the button to select the TURN UPS ON/OFF menu.
OPERATION EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 76.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 77 Chapter 10 UPS Maintenance This section explains how to: S Care for the UPS and batteries S Recycle used b.
UPS MAINTENANCE EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 78 When to Replace Batteries When the indicator flashes and the LCD panel displays Battery Failure, the batteries may need replacing. Contact your service representative to order new batteries.
UPS MAINTENANCE EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 79 Using the UPS Maintenance Bypass Switch The UPS maintenance bypass switch is located on the back of the UPS (see Figure 46). The maintenance bypass switch is used to bypass the UPS during maintenance or servicing.
UPS MAINTENANCE EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 80 To switch the UPS to maintenance bypass from Normal mode: 1. Turn the maintenance bypass switch through the SERVICE position to the BYPASS position.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 81 Chapter 11 Specifications This section provides the following specifications for the Powerware 9355 models.
SPECIFICATIONS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 82 Table 10. Dimensions and Weights Dimensions (H × W × D) Weight 2-High UPS 32.2 ” × 12 ” × 33.5 ” (81 × 30 × 85 cm) 381 lb (173 kg) 3-High UPS-32 47.
SPECIFICATIONS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 83 Table 12. Technical Specifications Technology Online, double-conversion topology with static bypass switch and 3-position maintenance bypass switch.
SPECIFICATIONS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 84 Table 13. Model Specifications 10 kVA Model Output Voltage (Line–Line) 208 208 208 220 Ou.
SPECIFICATIONS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 85 Table 14. Battery Specifications Battery Type 9 Ah sealed, valve-regulated lead acid (VRL A.
SPECIFICATIONS EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 86.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 87 Chapter 12 Troubleshooting The Powerware 9355 is designed for durable, automatic operation and also alerts you whenever potential operating problems may occur.
TROUBLESHOOTING EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 88 Action Possible Cause Alarm or Condition Overtemperature LED is on. 1 beep every second. UPS internal temperature is too high or the fan has failed.
TROUBLESHOOTING EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 89 Service and Support If you have any questions or problems with the UPS, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a UPS technical representative.
TROUBLESHOOTING EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 90.
EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 91 Chapter 13 Limited Warranty WARRANTOR: The warrantor for the limited warranties set forth herein is Eaton Power Quality Corporation, a Delaware Corporation (“Eaton”).
LIMITED WARRANTY EATON Powerware ® 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com 92 END-USER’S OBLIGATIONS: In order to receive the benefits of this Warranty, the End -Use.
Een belangrijk punt na aankoop van elk apparaat Powerware 15 KVA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Powerware 15 KVA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Powerware 15 KVA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Powerware 15 KVA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Powerware 15 KVA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Powerware 15 KVA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Powerware 15 KVA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Powerware 15 KVA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.