INSTALLATION INSTRUCTIONS UFM Universal Flat Mount NORTH AMERICA EUROPE AUSTRALIA, NEW ZEALAND, OCEANIA (DISTRIBUTOR) 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-.
- 2 - - Warnings 2 - Assembly drawing 3 - Flat panel list 4 - Parts list 6 9 h t p e d d a e r h t e h t g n i k c e h C - 0 1 y a l p s i d l e n a p t a l f e h t f o r e t n e c e h t g n i d n i F.
- 3 - 1 6.000 (406 . 4) 16 . 0 0 0 ( 406. 4) 1. 943 (49. 3) 5 .000 (1 2 7 ) 28 . 0 0 0 ( 171. 2) C L 3 .500 ( 88.9) C L 5. 0 0 0 (127) 16 . 0 0 0 ( 406. 4) 24 . 2 9 0 ( 616. 97) 16 . 0 0 0 ( 406. 4) 21. 790 (553 . 4) 1. 2 4 5 ( 31. 75) A B C D E F G H B A F H 21.
- 4 - Flat panel list Hitachi EIKI Electrograph Gateway 32HDT20,CMP307XJ,CMP307XU,32HD T20 CMP401HDU, CMP402HDE, CMP402HDU, CMP4120HDU,CMP4121,CMP4121HDU,CMP4201U, CMP4202U, 42HDW10,42HDT20, 42HD T50,.
- 5 - SONY Sanyo VIEWSONIC Sampo PDP421A: M5 x 20 - ¼” nylon spacer (small) PDP42H1NA: M5 x 20 - ¼” nylon spacer (small) VPW420: M8 x 30 – ½” nylon spacers - sleeves VPW425: M8 x 30 – ¼.
- 6 - (Qt y 8) (Qty 8) M6 x 1 2 M5 x 50 M5 x 16 M5 x 25 M5 x 20 M5 x 12 M4 x 25 M4 x 16 M8 x 70 M8 x 35 (Qty 4) (Qty 4) (Qty 6) (Qty 4) (Qty 6) M8 x 30 M8 x 25 (Qty 4 ) M8 x 2 0 (Qty 6 ) (Qty 6) (Qty 6) (Qty 4 ) (Qty 8) M6 x 20 (Qty 6 ) Parts list This wall m ount is ship ped wit h all proper inst allation har dware and c omponents.
- 7 - 1/4" Ny lon spacers 5/16 " Fl at w a s h er s (metal) 1 " Ny lon s p ac ers 1/4 " N yl on s pac e r s 9/16 " Nylo n s pacers (l arge ) (small) 1/2" Ny lon spacers (.
- 8 - Parts list (con’t) Level (1) 5/16" flat washers (4) 5/16" x 3" La g bolts (4) (used on w ood studs only) Griplates™ (8) Wall plate (1) Mounting brac ket s (left & right) All of these parts are use d to install the mounti ng bracket.
- 9 - Checking the thread depth on your flat panel Inverted flat panel display Thread insert Thread depth indicator Figure 2 Figure 3 Figure 1 Markin g the de p th 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the sam e full depth and mark it.
- 10 - C L L C Finding center of the flat panel display Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring fro m outside to outside of the chassis. See figure 1. Using a pencil lightly mark the center of your flat panel.
- 11 - Positioning the mounting brackets Inverted flat p anel Nylon spacers if Applicable ( see chart ) on p a g e 4 and 5 Center mar k Bottom of flat panel Install the nylon spacers to the mounting points on the flat panel see figure 3. Lay the left and right m ounting brackets (stamped arrows facing out).
- 12 - C L Bottom of flat panel Align the mounting brackets The mountin g brackets are designe d with a center o f viewing guide on the side of them . See figure 6. Bottom of flat panel Mounting bracket Center of flat panel Center of viewing guide Match the cent er of viewing gui de with the center line you marke d in step 1.
- 13 - DIMPLES FACING UP 3/4" DIMPLES FACING UP DIMPLES FA CING DOWN DIMPLES FAC ING DOW N Securing the mounting brackets The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE : If your plasma uses M8 x 20 Phillip screws.
- 14 - 16" 16" Finding the wood studs behind the wall structure Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs.
- 15 - 16" 16" Marking the mounting points on the wall Place the bottom portion of the wall plate to the reference line and mark the four (4) lag bo lt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling.
- 16 - Securing the wall plate to wood studs Wall p late (4) 5/16" x 3" lag bolts and (4) flat washers (supplied) Level and secure the p late to the wall with the reference arrow facing up to the ceiling. Secure the plate using the four (4) 5/16" lag bolts and flat washers (supplied).
- 17 - Securing the wall plate to a concrete wall Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Use a min dia of 5/16” x 2 ¼” lg concrete wedge anchors (commercially available). See figure 14. Use a minimum diameter of 5/16” x 2 ¼” long wedge anchors (commercially available).
- 18 - AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECO MMENDED FOR INSTALLATION OF T HIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POS SIBLE DAMAGE TO THE FLAT PANEL.
- 19 - Make any lateral shift adjustment and lock it b y tighten ing the two (2) ¼”-20 Phillips screws found on the bottom of the mounting brackets.
- 20 - PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defect s in material and workmans hip for the lifetime of the original installation of this product.
Een belangrijk punt na aankoop van elk apparaat Premier Mounts Universal Flat-Only Mount UFM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Premier Mounts Universal Flat-Only Mount UFM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Premier Mounts Universal Flat-Only Mount UFM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Premier Mounts Universal Flat-Only Mount UFM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Premier Mounts Universal Flat-Only Mount UFM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Premier Mounts Universal Flat-Only Mount UFM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Premier Mounts Universal Flat-Only Mount UFM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Premier Mounts Universal Flat-Only Mount UFM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.