PLEASE READ ALL OF THE OWNERS MANUAL AND SAFETY NOTES IMPORTANT SAFETY NOTES: 1. When installing your stove, particular attention should be paid to fire protection.
TABLE OF CONTENTS Safety label ................................................................................................................... ...................... 3 Dimensions ....................................................................
3100 SAFETY LABEL (found on back of stove) Page 3 Manufactaured by: Model: Quadra-Fire 3100 Serial No..
24 1/ 2" ( 622m m ) 9" (229 m m ) 21 1/ 2" ( 546m m ) 2 1/ 4" ( 57m m ) 23" (58 4m m ) DIMENSIONS Page 4 FIGURE 1b FIGURE 1a 20 1/2" (5 21m m ) 9" (229m m ) 24 1/2&q.
DIMENSIONS Page 5 26 5/ 8" ( 676m m ) 23 7/ 8" ( 606m m ) 13 1 1/ 16" (348m m ) 4 5/ 16" ( 1 10m m ) 24 5/ 8" ( 626m m ) 25" (63 5m m ) 9" ( 2 29 m m ) 2 13/ 16".
Minimum clearances to Combustible Materials (in inches and millimeters) for Quadra-Fire 3100 Standard Stove Chimney & Installation Clearance Connector A B C D E F Residential Standard Note 1 14”.
SAFETY LISTING The Quadra-Fire 3100 is listed by OMNI-Test Laboratories, Inc. , Beaverton, Oregon, to UL 1482-83, (UM)84 HUD and ULC S627. It is also approved for mobile home installations with outside combustion air in the U.S. (see pages 15 and 16 for further details).
CHIMNEY CONNECTOR The chimney connector must be 6” (152mm) diameter with a minimum thickness of 24 gauge. Do not use aluminum or galvanized steel. They cannot properly withstand the extreme temperatures of a wood fire. Do not use chimney connector pipe as a chimney.
A chimney inside the house must have at least 2” (50mm) of clearance to the combustible structure. A chimney outside the house must have at least 1” (25mm) clearance to the combustible structure. Firestops must be installed in the spaces where the chimney passes through floors and/or ceiling (Figure 5).
A chimney must be the required height above the roof or other obstruction for safety and proper draft operation. The chimney must be a minimum of 3’ (914mm) higher than the highest point where it pa.
2. THIMBLE : An approved thimble must be used when the connection from the stove is made through a combustible wall to a masonry chimney. There are several methods you can use for connection through a combustible wall, two of which are illustrated in this manual.
Minimum 3 ½” (89mm) [4” (102mm) nominal] thick solid bricks are to be used. The fire clay liner (ASTM C35 or equivalent), 5/8” (16mm) wall thickness, must not penetrate into the chimney beyond the inner surface of the chimney flue liner and must be firmly cemented in place.
First, build the frame for the thimble, making sure that it is no smaller than 14½” (368mm) diameter, which will maintain a 2” (50mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame. Then insert the frame into the opening, toe-nailing it to the wall studs.
CONNECTION TO A METAL PREFABRICATED CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed precisely.
MOBILE HOME INSTALLATION You must use a Quadra-Fire 3100 outside air kit (see page 16 for part numbers) for installation in a mobile home. Use of alternative material will void warranty. 1. An outside air inlet must be provided for combustion and be unrestricted while unit is in use.
3100 PEDESTAL MODELS 1. Kit includes two 1” (25mm) rope gaskets to be tucked under pedestal to seal off both sides. 2. Floor installation: Cut a 4” (102mm) minimum hole in the floor to accommodate outside air piping. Use 4” (102mm) minimum metal flex or rigid pipe to directly connect outside air to the unit or into vented crawl space.
1. Place protective pad or stove pallet on floor. 2. Lay body of stove on its back on protective pad or pallet. 3. Slide pedestal over adapter on bottom of stove 4. Line up holes in sides of pedestal with holes in adapter. 5. Bolt pedestal into place, and tighten securely.
Page 18 1. Remove ash removal system top and bottom cover plates by loosening nuts under stove. 2. Discard both plates. 3. Insert ash removal system grate into opening in firebox floor. 4. Continue with proper installation according to model you have purchased: pedestal or leg.
ASH REMOVAL SYSTEM OPERATING AND CLEANING CAUTION : Do not operate stove with ash removal system door open. Store ash in metal container until hot embers have cooled completely. 1. When stove is cool, open front door and brush most of the ash into the center of the firebox.
OPERATING INSTRUCTIONS IMPORTANT - PLEASE READ BEFORE USING STOVE BURNING PROCESS In recent years there has been an increasing concern about air quality.
OPERATING INSTRUCTIONS (cont.) BLOWER OPERATING INSTRUCTIONS (see blower installation instructions on page 27) If your Quadra-Fire wood stove is equipped with an optional blower, you should follow these guidelines: 1. Initial (cold) start-up: Leave blower off until your stove is hot and a good coalbed is established.
OPERATING INSTRUCTIONS (cont.) BURNING GUIDELINES (cont.) MEDIUM: After a wood load has been burning on high for at least 15 minutes (longer for very large pieces or wet wood), close (pull out) the primary control (on the right side of the stove). Leave the secondary control (under the ashcatcher) open (pushed in).
MAINTENANCE CREOSOTE 1. Formation and need for removal : When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a newly-started or a slow-burning fire.
1. Remove door from stove and lay on a padded flat surface. 2. Remove glass tabs and screws with a Phillips screwdriver (turn screws counterclockwise). 3. Lift glass frame pieces and glass out of the door frame. 4. Lay new glass with fiberglass tape around it into the door frame, making sure the Quadra-Fire logo reads correctly to the outside.
BAFFLE REMOVAL AND INSTALLATION NOTE : The baffle in the 3100 stove is heavy (29 pounds). Moving the baffle around inside the stove takes strength and patience.
BRICK PATTERN 8. To install the baffle, repeat steps 2 through 7 in reverse. Be sure that the hole in the baffle is on its alignment pin on the rear shelf.
INSTALLATION OF OPTIONAL BLOWER Part #831-1700 The blower is shipped fully assembled and ready for installation. 1. Remove three ¼”-20 (3/8” hex head) bolts from blower cover, and remove nutbar. Discard nutbar. 2. Using bolts, attach blower to lower rear of stove, as shown.
1. Unscrew and remove the rear heat deflector. 2. Attach the two “ S ” clips to the upper edge of the outer wall of the stove. 3. Set top heat shield on stove and push down into “ S ” clips. 4. Install chimney pipe through hole in top heat shield.
Page 29 ACCESSORIES AND SERVICE PARTS ACCESSORIES 831-1650 Top shield, gold 831-0971 Top shield, black 831-1730 Outside air kit, pedestal 831-1740 Outside air kit, leg 831-1700 Blower 832-1091 Black d.
NOTES Page 30.
NOTES Page 31.
Aladdin Hearth Products, warrants their wood heating appliances to the original purchaser for the lifetime of the appliance, to be free from defects in material and workmanship. This warranty gives you specific legal rights; you may have other rights which may v ary from state to state.
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire 3100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire 3100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire 3100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire 3100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire 3100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire 3100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire 3100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire 3100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.