Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 1 Model(s): QFP44 Owner ’ s Manual Installation and Operation Installation and service of this appliance should be performed by quali ed personnel.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Numb.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 4 Î = Contains updated information. 14 Appliance Setup A. Remove Glass Assembly 54 B. Clean the Appliance 54 C. Install the Refractory 54 D. Adjust the Air Shutter 55 E. Adjust the V ertical Baf e 56 F .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 5 B. Limited Lifetime W arranty W arranty Period HHT Manufactured Appliances and V enting Components Covered Parts Labor Gas W ood Pellet EP A Wood E.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 6 gasketing, glass discoloration, rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baf es, repots, doors, or rebox area are not covered by this warranty .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 7 C. BTU Speci cations MODELS: QFP44 LABORA TOR Y : Underwriters Laboratories, Inc. (UL) TYPE: Direct V ent Gas Heater STANDARD: ANSI Z21.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, build.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 9 Decorative Doors (not shown) Section 2.E. Fixed Glass Assembly Section 2.F . Mantel Hearth (not required) Dashboard Control Section 2.G. Clear Space Section 2.D. Figure 2.1 General Operating Parts B.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 10 Clear Space 3 ft (0.91 m) in front of appliance C. Clear Space W ARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 1 1 Ignitor Battery Box By pulling the drawer forward, the ignitor battery box can be accessed to replace the AA battery as necessary . See Figure 2.4. Ignitor Battery Box Figure 2.4 Accessing the Ignitor Battery Box.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 12 Remote Receiver The remote receiver has a 3-position slide switch: OFF/REMOTE/ON (see Figure 2.5). NOTE : The remote receiver will only respond to the transmit ter when the 3 - position slide but ton on the remote receiver is in the Remo te position.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 13 1. LOW - Battery power low . Replace batteries within two weeks. 2. TIMER - Indicates time remaining before system shuts off, when timer- programmed, 9 - hour maximum setting. 3. MODE - Indicates operation MODE of system.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 14 Setting °F/°C Scale The factory setting for temperature is degrees Fahrenheit °F). T o change this setting to degrees Centigrade (°C): • Remove the battery cover on the back of the transmitter and locate the “setting button” at the top center of battery compartment (see Figure 2.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 15 Adjusting the Flame Height - Operates in ON or THERMO mode This remote control system allows the user to control the height of the FLAME when the gas valve is factory equipped with a FLAME CONTROLLER.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 16 H. Before Lighting Fireplace Before operating this replace for the rst time, have a quali ed service technician : • V erify all shipping materials have been removed from inside and/or underneath the rebox.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 17 1. T urn unit of f with remote. 2. T urn of f all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 18 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the replace of f and allow it to completely cool. • Remove xed glass assembly .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 19 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care. Glass is breakable.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 20 V enting Frequency: Seasonally By: Homeowner T ools needed : Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 21 Figure 3.1 Standing Pilot Flame Patterns.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 22 Noncombustible roof flashing maintains minimum clearance around pipe (SECTION 10) Ceiling Firestop on floor of attic (SECTION 8) V ent Pipe (SECTI.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 23 B. Design and Installation Considerations Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 24 5 5 F raming and Clearances A. Select Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 25 Combustible flooring may be installed next to the front of the appliance. ALL SURF ACES MUST BE FLUSH WITH THE BOTT OM OF THE UNIT . C B A Drywall 1-1/2 in. (38 mm) 0 in. 1-1/2 in. (38 mm) 0 in. D 40-7/8 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 26 Mantel Non-combustible Face A A = 53 in. (1346 mm) min. Non-combustible Mantel 12 in. (308 mm) maximum depth A = 66 in. (1676 mm) min. Combustible Mantel D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci ed.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 27 Direct V ent Gas, Wood or Fuel Oil T ermination 20 in. (508 mm) (minimum) to Perpendicular W all (DV only) Wood, Gas or Fuel Oil T ermination 20 in. min. * (508 mm) T ermination Caps Same Height * If using decorative cap cover(s), this distance may need to be increased.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 28 Dimension Descriptions A Clearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * B Clearance to window or door that may be opened – 10,000 BTUs or less, 6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 29 Horizontal V ertical 8-1/2 in. 8-1/2 in. 12 in. On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 30 H 1 V 1 T o replace the rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 31 4 ft min. (1.22 m) 17 ft max. (5.18 m) 3 ft min. (.91 m) 1. T op V ent - Horizontal T ermination - (continued) Figure 7.4 T wo 45° Elbows replacing One 90° Elbow Figure 7.5 Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 H 1 V 2 H 2 3 ft (.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 32 2. T op V ent - V ertical T ermination No Elbow Figure 7.7 Figure 7.8 T wo Elbows Note: If installing a vertical vent/ter- mination off the top of the appliance, the ue restrictor should be used.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 33 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows 12 ft (3.66 m) min. 60 ft (18.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 34 No combustible framing to be located within shaded area. 1-1/2 in. (13 mm) minimum to perpendicular wall. WAL L 2 x 4 or 2 x 6 header Drywall 3 in. (76 mm) 1 in. (25 mm) minimum Air space clearance to bottom and sides of horizontal pipe must be at least 1 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 35 C. Install the Ceiling Firestop A ceiling restop MUST be used between oors and at- tics. • Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ oor (see Figure 8.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 36 Bend all tabs inward 90° to maintain clearance and prevent insulation from falling inside Insert 3 screws Bend 4 tabs inward 90° to maintain clearance Laser-etched cut lines D. Install Attic Insulation Shield W ARNING! Fire Risk.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 37 A. Secure and Level the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown-in insulation.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 38 Lances 10 10 Install V ent P ipe A. Assemble V ent Sections Attach Pipe to the Firebox Assembly Note: The end of the pipe sec tions with the lanc ed tabs will face towards the applianc e.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 39 B. Assemble Slip Sections W ARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in. (13 mm) in length.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 40 Figure 10.7 Securing V ertical Pipe Sections Figure 10.8 Securing Horizontal Pipe Sections D. Disassemble V ent Sections • Rotate either section (see Figure 10.9) so the seams on both pipe sections are aligned as shown in Figure 10.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 41 E. Install Metal Roof Flashing Note: Skip to Sect ion 1 0.I. if using the RF 4 - 8. • See minimum vent heights for various pitched roofs (Figure 10.1 1) to determine the length of pipe to extend through the roof.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 42 F . Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp. • Connect both halves of the storm collar with two screws (see Figure 10.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 43 G. Install RF4-8 The RF4-8 may be used in place of the roof ashing and storm collar . Pipe must be supported within 12 in. (305 mm) of the roo ine using plumbers strapping when using the RF4-8 Flashing.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 44 Important Notice: Heat shields may not be eld constructed. I. Heat Shield Requirements for Horizontal T ermination W ARNING! Risk of Fire! T o prevent overheating and re, heat shields must extend through the entire wall thick- ness.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 45 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in. (38 mm) min.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 46 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci ed and approved parts.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 47 Control Knob Screw (pressure adjustment) Pin (blue-NG, red-LP) Solenoid Lock Nut Figure 1 1.7 V alve Components • Replace 2 screws holding pilot bracket to burner . • Pull hood keeper from pilot and lift hood of f pilot assembly .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 48 C. Gas Connection • Refer to Reference Section 16.A. for location of gas line access in appliance.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 49 B. Standing Pilot Ignition System Wiring • The standing pilot ignition system wiring does not require a 1 10 V AC supply to operate. • A 1 10 V AC junction box MUST be installed for use with a fan or remote control.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 50 D. Electrical Service and Repair W ARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 51 Mantel Non-combustible Face A A = 53 in. (1346 mm) min. Non-combustible Mantel 12 in. (308 mm) maximum depth A = 66 in. (1676 mm) min. Combustible Mantel Figure 13.1 Minimum Vertical and Maximum Horizontal Dimensions 1 1 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 52 0 in. 0 in. 0 in. Finish wall material may be combustible - T op and Sides High T emperature Sealant (300° F/149° C min.) Non-Combustible Zone These joints may be taped and covered with joint compound.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 53 14 14 Applianc e Setup C. Install the Refractory • Remove the refractory retainer from each side of the rebox. • Put the left side refractory in place and reinstall the left side refractory retainer .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 54 • Install the upper back refractory . Figure 14.4 Install Upper Back Refractory • Install the right side refractory . • Slide the back refractory slightly from side to side as necessary to close up any gaps in the corners.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 55 Figure 14.7 Adjust the Vertical Baf e Figure 14.8 Positioning Rear Log F . Install Logs, Ember Bed & Rockwool • Remove the grate from the hearth by removing the screws. • Position rear log over the locating tabs at the rear of the hearth pan.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 56 • Position the right front log over the grate bars, aligning the cut outs on the bottom of the log with the bars. See Figure 14.12 Figure 14.12 Positioning Right Front Leg • Position the cutout on the bottom of the left log over the locating bracket on the grate.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 57 W ARNING! Risk of Explosion! Follow rockwool placement instructions. DO NOT place rockwool directly over burner ports. Replace rockwool material annually . Improperly placed rockwool interferes with proper burner operation.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 58 A. Standing Pilot Ignition System 15 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 59 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) C. Failed valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 60 16 16 Reference Materials 49 in. 1245 mm 40 in. 1016 mm 35-1/2 in. 902 mm A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 61 B. V ent Components Diagrams Figure 16.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pi p e inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 62 B. V ent Components Diagrams ( continued ) Figure 16.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 63 B. V ent Components Diagrams ( continued ) Figure 16.4 DVP V ent Components 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW V ertical T ermination Cap (High wind) 14 in. (356 mm) 12 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 64 B. V ent Components Diagrams ( continued ) Figure 16.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 65 C. Service Parts 13 14 17 18 20 16 19 15 28 31 32 29 30 26 24 22 21 27 23 25 6 3 1 7 4 2 5 Log Set Assembly Refractory Assembly 8 9 10 11 12 QFP44 Service Parts 44 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 66 24 23 22 12 26 19 20 16 3 4 5 10 11 9 8 6 13 7 25 14 17 15 18 21 2 1 Service Parts QFP44 Service Parts Diagram 44 in. Gas Appliance - DV Beginning Manufacturing Date: Aug 2006 Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 67 D. Optional Components Door (iron full view) DF-QFP44-IFV Door (iron operable) DF-QFP44-IOP Door (Craftsman operable, black) DF-QFP44-COP-BK Door .
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 68 E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer , please visit www .
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire QFP44 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire QFP44 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire QFP44 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire QFP44 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire QFP44 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire QFP44 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire QFP44 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire QFP44 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.