R www .quadrare.com 7037-135E September 1, 2008 DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance in - structions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation.
Page 2 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Hearth & Home T echnologies welcomes you to our tradi - tion of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durabil - ity , and performance.
September 1, 2008 7037-135E Page 4300 Wood Stove Series (ACC) R Section 1: Listing and Code Approvals A. Appliance Certications ...................... 4 B. Mobile Home Approved ...................... 4 C. Glass Specications .................
Page 4 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) 1 Listing and Code Approvals The Quadra-Fire 400 Series Wood Stove (ACC) meets the U.S . E nvi ronm enta l Prot ecti on Ag ency ’s 19 90 par tic ulat e emission standards. A. Appliance Certication C.
September 1, 2008 7037-135E Page 5 4300 Wood Stove Series (ACC) R 2 Getting Started A . Design, Installation & Location Consider ations Consideration must be given to: • Safety • Convenience .
Page 6 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-leve.
September 1, 2008 7037-135E Page 7 4300 Wood Stove Series (ACC) R Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove pe rf orm anc e.
Page 8 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Floor Protector Chimn ey Conn ecto r Insula ted " T " Flashi ng Li s te d T e r min a tion C a p T r im Coll ar on I n s i d.
September 1, 2008 7037-135E Page 9 4300 Wood Stove Series (ACC) R 3 Dimensions and Clearances 28-7/16 in.(722mm) 26-5/16 in. (668mm) 15 -5/ 8 in . (3 97 mm) 1 1-1/2 in. (292mm) 16 in. (406mm) 20-3/4 in. (527mm) C L 4-1/2 in (108mm) Outside Air Connection A.
Page 10 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Appliance Dimensions (Cont’d) Figure 10.1 Figure 10.2 Figure 10.3 Figure 10.4 4300 Step Top Pedestal Model 4300 Step Top Leg Model 2-7/8 in. (606m m) -7/1 6 in. (849m m) 15-1/1 6 in.
September 1, 2008 7037-135E Page 1 1 4300 Wood Stove Series (ACC) R B. Clearances to Combustibles (UL and ULC) BAC K WA LL / SIDE W ALL CORNER INST ALLA TIO N 90° OFF TOP UP & OUT CEIL ING CLEARA.
Page 12 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) A. Hearth Protection Requirements FLOOR PROTECTION: Floor protector must be non-com - bustible material, extending beneath heater and to the front, sides and rear as indicated.
September 1, 2008 7037-135E Page 1 4300 Wood Stove Series (ACC) R Must ext end 2 in. (51m m) beyond each side of pipe (shad ed are a) NOTE: • Illustrations and photos reect typical installations and are FOR DESIGN PURPOSES ONL Y . • Illustrations/diagrams are not drawn to scale.
Page 14 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) B. Outside Air Kit Installation 1. Remove all materials from packing box. 2. Using a #2 Phillips screw driver attach the ex adapter to the stove using 4 screws. Figure 14.1. . Remove circular” knock-out” in the base of the pedestal.
September 1, 2008 7037-135E Page 15 4300 Wood Stove Series (ACC) R C. Blower (Optional) NOTE: The blower cord is equipped with a pronged (grounding) plug for your protection against shock hazard. Do not remove. 1. Remove the bolts (1/4”-20 Phillips head) on the outer skin at the bottom rear of appliance.
Page 16 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) NOTE: I n Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS.
September 1, 2008 7037-135E Page 17 4300 Wood Stove Series (ACC) R Thimble Site constructed for masonry chimney installation: Components • A minimum length of 12 inches [05mm] (longer for thicker walls) of solid insulated factory-built chimney length constructed to UL 10 T ype HT 6 inch (152mm) inside diameter .
Page 18 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Chimney Height / Rise and Run Th is pro duct was des igne d for an d tes ted on a 6 inch (152 mm) chimney , 14 to 16 feet (420-480cm) high, (includes stove heig ht) measure d from the base of the applia nce.
September 1, 2008 7037-135E Page 19 4300 Wood Stove Series (ACC) R D. Chimney T ermination Requirements Follow manufacturers instructions for clearance, securing, ashing and terminating the chimney .
Page 20 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) 6 Mobile Home Installation 10 . Burn wood only . Other types of fuels may generate poisonous gases (e.g., carbon monoxide). 1 1. If unit burns poorly while an exhaust blower is on in home, (i.
September 1, 2008 7037-135E Page 21 4300 Wood Stove Series (ACC) R 7 Appliance Set Up Figure 21.3 Do NOT operate before fully assembling components. Burning your stove without a pedestal or leg kit attached: • Will void your warranty . • May result in property damage or personal injury .
Page 22 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Pedestal and Ash Removal System (Cont’d) Figure 22.3 Grate ARS Channel Replace bo th bricks back into f irebox Figure 22.2 Cover Plate Ash Re movel Drawer Adapters Oak Pedestal T rim Figure 22.
September 1, 2008 7037-135E Page 2 4300 Wood Stove Series (ACC) R B. Leg Kit and Ash Removal Installation (ARS) for Step Top Uni-Body Do NOT tilt the unit on the cast iron legs. • Tilting could lead to property damage. • Lift the unit upright and place it into position on the oor protector .
Page 24 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) N OTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently , but should not stop.
September 1, 2008 7037-135E Page 25 4300 Wood Stove Series (ACC) R 8 Operating Instructions B. Wood Selection & Storage Burn only dry seasoned wood. Store wood under cover , out of the rain and snow . Dry and well-seasoned wood will not only minimize the chance of creosote formation, but will give you the most efcient re.
Page 26 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) 2. Second Stage The next stage of burning, the secondary stage, is the period when the wood gives off ammable gases which burn above the fuel with bright ames. During this stage of burning it is very important that the ames be maintained and not allowed to go out.
September 1, 2008 7037-135E Page 27 4300 Wood Stove Series (ACC) R F . Burn Rates and Operating Efciency For maximum operating efciency 1. This appliance has a timer system (ACC) that operates the stove at its maximum efciency removing any guess work for the homeowner .
Page 28 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) G. Building A Fire Before lighting your rst re in the stove: 1. Conrm the bafe is correctly positioned. It should be even with the front tube and resting on all tubes. Figure 28.
September 1, 2008 7037-135E Page 29 4300 Wood Stove Series (ACC) R CORRECT POSITION Ceramic Blanket and Bafe Board are NOT in contact with the back of the rebox. Ceramic Blanket is NOT in contact with the back of the rebox and NOT even with the Baf - e Board in the front.
Page 0 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) J. Opacity (Smoke) This is the measure of how cleanly your appliance is burn - ing. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney , and 0% opacity means that no smoke column can be seen.
September 1, 2008 7037-135E Page 1 4300 Wood Stove Series (ACC) R 9 Maintaining & Servicing Y our Appliance A. General Maintenance Inspe ction : Inspe ct the system at the applian ce connec tion and at the chimney top.
Page 2 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) 4. Cleaning Plated Surfaces • Frequency: Prior to first burn and then as desired • By: Homeowner Clean all the ngerprints and oils from plated surfaces BEFORE ring the appliance for the rst time.
September 1, 2008 7037-135E Page 4300 Wood Stove Series (ACC) R B. Glass Replacement 1 . Ensure that the re is out and the appliance is cool to the touch. 2. Protect a table or counter top with padding or towels. Protect your hands and wear gloves to prevent injury .
Page 4 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Replace the rebrick if they become crumbly and/or if there is a 1/4 inch (6.5mm) gap between the bricks. Inspect the rebrick after each ash removal. The rebox is lined with high quality rebrick, which has exceptional insulating properties.
September 1, 2008 7037-135E Page 5 4300 Wood Stove Series (ACC) R D. Bafe Removal 1. Remove all ash from the rebox, and extinguish all hot embers before disposal into a metal container .
Page 6 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) F . T ube Channel Assembly Replacement Removing Tube Channel Assembly 1. Remove the right side shield by removing 2 screws in the back using a Phillips head screw driver. 2. Remove 4 screws from channel access cover and remove cover.
September 1, 2008 7037-135E Page 7 4300 Wood Stove Series (ACC) R 10 T roubleshooting With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service.
Page 8 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) 1 1 Reference Materials Figure 38.1 - Door , Glass And Door Handle Assembly A. Exploded view Figure 38.2 - Burn Rate Air & Start-Up Air Controls Glass Size: 15-1/2” wide x 1-/8” high 42 43 44 45 46 47 48 31 30 40 32 41 Item Description Part No.
September 1, 2008 7037-135E Page 9 4300 Wood Stove Series (ACC) R SIZES (#) Bafe Board: 9-1/2” w x 15-/4” h, each (#29) Ceramic Blanket: 19” w x 1-/4” h, 1/2” thick Figure 39.
Page 40 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) SIZES (#) Bafe Board: 9-1/2” w x 15-/4” h, each (#29) Ceramic Blanket: 19” w x 1-/4” h, 1/2” thick Figure 40.
September 1, 2008 7037-135E Page 41 4300 Wood Stove Series (ACC) R IMPORT ANT : THIS IS DA TED INFORMA TION . When requesting a part for your appliance, please supply serial number and model name/number to ensure correct service parts. All parts may be order from an authorized dealer .
Page 42 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Component Pack, Millennium Model, Nickel (includes T ouch-up Paint, Nickel Spring Handles (1) 1/2 inch and (2) 1/4 inch, T rimount Plug, Owner ’s Manual, W arranty Card) 7037-015 Component Pack, Step-T op Model (includes T ouch-up Paint, Owner ’s Manual, W ar - ranty Card).
September 1, 2008 7037-135E Page 4 4300 Wood Stove Series (ACC) R Pedestal (only) Assembly, Step-Top Model 7033-013 2 Pedestal Base, Millennium Model 7033-163 3 Pedestal Riser , Millennium Model 70-207 26 Rear Air Channel Assembly 70-002 Rope, Door , /4 in.
Page 44 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) Date of Service Performed By Description of Service C. Service And Maintenance Log.
September 1, 2008 7037-135E Page 45 4300 Wood Stove Series (ACC) R D. Homeowner ’ s Notes.
Page 46 7037-135E September 1, 2008 R 4300 Wood Stove Series (ACC) E. W arranty Policy Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective bra.
September 1, 2008 7037-135E Page 47 4300 Wood Stove Series (ACC) R HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main - tenanc.
R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES 7037-135E September 1, 2008 Page 48 CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , log onto www .
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire Quadra-Fire 43M-ACC-K (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire Quadra-Fire 43M-ACC-K heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire Quadra-Fire 43M-ACC-K vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire Quadra-Fire 43M-ACC-K leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire Quadra-Fire 43M-ACC-K krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire Quadra-Fire 43M-ACC-K bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire Quadra-Fire 43M-ACC-K kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire Quadra-Fire 43M-ACC-K . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.