6-01376-07 StorNext 3.1 ® StorNext File System T uning Guide File System T uning Guide File System T uning Guide.
StorNext 3.1 File System Tuning Guide, 6-01376-07 , Ver. A, Rel. 3.1 , October 2007, Made in USA. Quantum Corporation provides this publ ication “as is” without warranty of an y kind, either express or implied, including but not limited to the implied warranties of merc hantability or fitness for a particular purpose.
StorNext File System Tuning Gu ide i Content s Chapter 1 StorNext File System Tuning 1 The Underlying Storage System ............. ... ......... .............. .............. .............. ... 1 RAID Cache Configuration .............. .............. .
StorNext File System Tuning Guide 1 0 S torNext File System T uning The StorNext File System (SNFS) pr ovides extremely high performance for widely varying scenarios. Many factors determine the level of performance you will realiz e. In particular, the performance characteristics of the underlying st orage system are the most critical factors.
StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 2 RAID Cache Configuration 0 The single most i mportant RAID tuning component is the cache configuration. This is particular ly t rue for small I/O operat ions.
StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 3 File System Mana ger (FSM) stati stics reports in the cvlog file.
StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 4 unusual cases, it severely degrades typical sce narios. Therefore, it is unsuitable for most environments.
StorNext File System T uning File Size Mix and Application I/O Characteristics StorNext File System Tuning Guide 5 File Size Mix and Application I/O Characteristics It is always valuabl e to understand th e file size mix of the target dataset as well as the application I/O characte ristics.
StorNext File System T uning File Size Mix and Application I/O Characteristics StorNext File System Tuning Guide 6 It is usually best to configure the RA ID stripe size no greater than 256K for optimal small file buffer cache performance. For more buffer cache configuration settings, see Mount Command Options on page 17.
StorNext File System T uning The Metadata Network StorNext File System Tuning Guide 7 The Metadat a Network As with any client/server protocol, SNFS perfor mance is subject to the limitations of the underlying network. Therefore, it is recommended that you use a dedicated Metadata Networ k to avoid contention with other network traffic.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 8 Some metadata operations such as fi le creation can be CPU intensive, and benefit from increased CPU power. The MDC platform is important in these scenarios because lower clock- speed CPUs such as Sparc and M ips degrade performance.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 9 Example: [stripeGroup RegularFiles] S tatus UP Exclusive No ##Non-Exclusive stripeGroup for all Fi les##.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 10 Str i p eB re a dth 0 T h i s s e t t i n g m u s t m a t c h t h e R A I D s t r i p e s i z e o r b e a m u l t i p l e o f t h e R A I D stripe size. Matching th e RAID stripe size i s usually the most optimal setting.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 11 InodeCacheSize 0 This setting consumes about 800-1000 bytes of memory times the nu mber specified.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 12 Settings greater than 64K are not recommended because performance will be adversel y impacted due to in efficient metad ata I/O operations.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 13 man cvfs_config page.) T he snfsdefrag man page explains the command options in greater detail. FSM hourly statistics reporting is another very useful tool.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 14 SNFS supports the Windows Perfmon utility. This provides many useful statistics counters for the SNFS client component. To instal l, obtain a copy of cvfsperf .
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 15 The “PERF: VFS” trace shows throughput measured for the read or write system call and significant a.
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 16 • Identify read/modify/w rite condition. If buffered VFS writes are causing De vice reads, it might be beneficial to match I/O request size to a multiple of t he “cachebufsize” (default 64KB; see mount_cvfs man page).
StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 17 Mount Command Options 0 The following SNFS mount command settings are explained in greater detail in the mount_cvfs man page. The default size of the buffer cache varies by platform and main memory size, and ranges between 32MB and 256M B.
StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 18 SNFS External API 0 The SNFS External API might be useful in some scenarios because it offers programmatic use of special SN FS performance capabilities such as affinities, preallocation, and quality of service.
StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 19 is set to auto-detect but the host is set to 1000Mb/full , you will observe a high error rate and extremely poor perfor mance. On Linux the ethto ol command can be very useful to invest igate and a djust speed/duplex settings.
StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 20 Figure 1 Multi-NIC Hardware and IP Configurati on Diagram In the diagram there are two subnetwork s: the blue subnetwork (10.0.0.x) and the red subnetwork (192.
StorNext File System T uning Distributed LAN Servers StorNext File System Tuning Guide 21 Distributed LAN Servers Distributed LAN Servers must ha ve suff icient memory. When a Distributed LAN Server does not have sufficient me mory, its performance in servicing Distributed LAN I/O requests might suffer.
StorNext File System T uning Distributed LAN Client Vs. Legacy Network Attached Storage StorNext File System Tuning Guide 22 Performance 0 DLC outperforms NFS and CIFS for single-stream I/O and provides higher aggregate bandwidth. For in ferior NFS client implementations, the difference can be more th an a factor of two.
StorNext File System T uning Windows Memory Requirements StorNext File System Tuning Guide 23 Therefore, DLC provides incr eased st abilit y that is comparable to the StorNext SAN Client. Consistent Security Model 0 DLC clients hav e the same security mo del as StorNext SAN clients.
StorNext File System T uning Windows Memory Requirements StorNext File System Tuning Guide 24 The first is the Directory Cach e Size . The default is 10 (MB). If you do not have large directories, or do not pe rform lots of directory scans, this number can be reduced to 1 or 2 MB.
StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 25 Sample FSM Configuration File This sample configuration file is locat ed in the SNFS install directory under the examples subdirectory named example.
StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 26 MAX(StripeBreadth) # MaxMBPerClientReserve 50 # in MBs, default 100 MB reserved per client # OpHangLimit.
StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 27 [Disk CvfsDisk4] Status UP Type VideoDrive [Disk CvfsDisk5] Status UP Type VideoDrive [Disk CvfsDisk6] S.
StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 28 [Disk CvfsDisk17] Status UP Type DataDrive # **************************************************************************** # A stripe section for defining stripe groups.
StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 29 [StripeGroup AudioFiles] Status UP Exclusive Yes ##Exclusive StripeGroup for Audio File Only## Affinity .
Een belangrijk punt na aankoop van elk apparaat Quantum 6-01376-07 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quantum 6-01376-07 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quantum 6-01376-07 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quantum 6-01376-07 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quantum 6-01376-07 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quantum 6-01376-07 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quantum 6-01376-07 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quantum 6-01376-07 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.