Gebruiksaanwijzing /service van het product SeaEra Toilets van de fabrikant Raritan
Ga naar pagina of 16
Pressurized Freshwater Model Sea W ater Model (Remote Pump) Sea W ater Model (Integral Pump) The SeaEra toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste.
Press push-button switch and hold until all waste is cleared from the toilet bowl. • No special toilet paper is required. • W ater should appear in the bowl within ten seconds. If not, see troubleshooting section. • Hard objects or stringy substances (paper towels, feminine hygiene products, filter cigarettes, etc.
Clean Gaske t and Gasket Contact Surf aces Thoroughly Unscre w Tighten Cleaning Instructions IMPOR T ANT : Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These may cause damage to the toilet. Using C.
WINTERIZING IMPOR T ANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations.
Integral and Remote Intake Pump Models Parts Require d 3/4" (19mm) I.D. intake hose approximately 3 feet (1m) long. 1" (25mm) or 1 1/2" (38mm) I.D. discharge hose approximately 3 feet (1m) long. T wo buckets Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1.
SPECIFICA TIONS Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size 6 5/8" (16.8cm) 19 3/4" (52.1cm) Household 17 1/2" (44.5cm) Marine 14 3/8" (36.5cm) Household 13" (33cm) Marine 11 1/8" (28.3cm) 14 7/8" (37.
7 Mounting T oilet Mounting surface must be flat and solid. 1. Install seat on toilet. 2. Remove motor cover . 3. Place toilet where it will be located. Make sure ther e is r oom to route hoses. Make sure seat will open pr operly . 4. Mark location of toilet base mounting holes on mounting surface.
8 90° Rotation of T oilet Bowl T oilet bowl can be rotated 90° on the base, for installing in confined locations. NOTE: SeaEra Models with Integral Pump: Replace existing hose from the intake pump to the toilet bowl with a longer hose. 1 . Determine which direction bowl is to be mounted.
INST ALLA TION Mounting W ater Solenoid V alve (Pressurized Fr eshwater Models Only) 1. Locate valve on a solid flat surface in an area that is dry and well ventilated. 2. Mark and drill holes for water solenoid mounting bracket. NOTE: Hole size will depend on type of bolts/screws used (1/4" [6mm] size bolt/screws are recommended).
10 INST ALLA TION Discharge Lines 1 . Connect quality sanitation hose 1" (25mm) or 1 1/2" (38mm) I.D. to discharge fitting on toilet. 2 . Run hose to appropriate device (i.
11 From Seacock T o Intake Pump INST ALLA TION Intake Lines Pressurized Fr eshwater Models Install a shut off valve in intake line before water solenoid valve.
WIRING W ARNING: Hazard of Shock and Fir e • Always use proper wir e, wire connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect appliances to toilet circuit. • Make sure power is off before pr oceeding.
TR OUBLESHOO TING W ARNING: HAZARD OF ELECTRIC SHOCK - Bef ore beginning any work on the SeaEr a, be sure that all power to the unit has been turned of f. W ARNING: HAZARD OF FLOODING - Make sur e seacocks are in the CLOSED or OFF position befor e working on toilet.
EXPLODED P AR TS P ar t No. Description 1108A Macerator Nut 1222A W 90° Discharge F itting 1226 Mounting Scre w (4) 1226B 1/4-20 Hex Nut (4) 1234 Bo wl Gasket 1236A W Bo wl Spud Assembly 1236E Bo wl .
15 EXPLODED P AR TS SeaEra Exploded Parts V iew 1244 or 1237 1236A W 1236E 1234 VCAP 1226B RNI CH38 161105 C254 161130 1222A W 161125 F164 161107 1108A M23A 161123 161120 161115 31-102 161110 1610* HW.
L318 0103kgs Specifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, P.O. Box 1157, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.
Een belangrijk punt na aankoop van elk apparaat Raritan SeaEra Toilets (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Raritan SeaEra Toilets heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Raritan SeaEra Toilets vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Raritan SeaEra Toilets leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Raritan SeaEra Toilets krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Raritan SeaEra Toilets bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Raritan SeaEra Toilets kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Raritan SeaEra Toilets . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.