- Type H
Engineer:
Hydronic Heating Boilers
Contractor:
Commercial
Prepared By:
Models 2100-4001 (Indoor)
Model : Date:
EFFICIENT 82% thermal efficiency – highest of any atmospheric

THERMAL SHOCK PROOF Twenty-year warranty against thermal shock damage
up to 150°F differential Maximum operating temperature: 230°F
LIGHTWEIGHT A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY Cuts fuel costs substantially because the standby and
LOW WATER OPERATING TEMPERATURE Operates with water temperature as low as 105°F
Heat Exchanger ASME Inspected and Stamped
Gas Control Train Manual Main Gas Shut-off Cock Main Gas Pressure Regulator Redundant Safety Shut-off Valve Control Valve Firing Mode
B-7 Modulating B-5 Modulating, Outdoor Reset B-6 Two-stage B- Four-stage Digital Y-241 Electronic Sequencer,
160 PSIG National Board Approved Headers
Glass-lined Cast Iron – Standard Bronze – Option A-1 Finned Tubing
On/off (H4) Two-stage Firing (H3) Four-stage Firing (H9) Motorized Modulation (H2) B-6000 (H6) Fuel
1-4 Stages Y-281 Electronic Sequencer,
Copper – Standard Cupro Nickel – Option A-3 ASME Steel Tube Sheet Silicone O-Rings 60 PSIG ASME Pressure Relief Valve Temperature and Pressure Gauge
F-9 Low Water Cut-off Probe I-1 High Limit Control, Auto Reset S-1 Low Gas Pressure Switch S-2 High Gas Pressure Switch
Natural Gas Propane Gas Design Certified ANSI Z21.13/
(Boiler) Water Connections
Left Hand – Standard Right Hand – Option A-6 Flow Configuration
Construction Front Controls Stainless Steel Burners Polytuf Powder Coat Finish Built-in Draft Diverter Draft Inducer
Two-pass (Standard) Single-pass (Cast Iron Only)
Controls 120V, 60Hz, 1 Ph Power Supply 120/24V Transformer 100% Pilot Shut-off/Lockout Electronic, Intermittent Ignition (IID)
Motorized Draft Inducer –
Pilot High Limit Control, Manual Reset High Limit Control, Auto Reset –
Models 3001-4001 On/Off Switch Flow Switch Economaster II Pump Time Delay

1-8 Stages · Option D-2


* 1-1/2” or 2” contingent on boiler type code requirements NOTE: Ratings are for elevations up to 2,000 feet. For
elevations over 2,000 feet, reduce ratings 4% for every 1,000 feet above sea level.
** 4” on one-pass option

N/A – Not Applicable NOTES: Values represent maximum flows and pressure drops for closed heating systems. Maximum acceptable flow through heat exchanger tubes is 200 GPM (two-pass); 400 GPM (one-pass) Single-pass heat exchangers are to be used only when flow rates exceed the allowable for two-pass
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725 www.raypak.com