Page 1 of the Raypak 2100-4001 user manual — Catalog No.: 2000.26M Effective: 12-1-07 Replaces: 12-1-99
Pagina 1 · klik om te vergroten
Pagina 1

Raytherm ®

- Type H

Job:

Engineer:

Hydronic Heating Boilers

Contractor:

Commercial

Prepared By:

Models 2100-4001 (Indoor)

Model : Date:

EFFICIENT 82% thermal efficiency – highest of any atmospheric

Raypak 2100-4001 — Job: diagram (page 1)
Afb. 1 · Job:

boiler available today

THERMAL SHOCK PROOF Twenty-year warranty against thermal shock damage

up to 150°F differential Maximum operating temperature: 230°F

LIGHTWEIGHT A floor load of 70 lbs./sq. ft. or less

HIGH RECOVERY Cuts fuel costs substantially because the standby and

radiation losses normal to other boilers and tank-type water heaters are eliminated

LOW WATER OPERATING TEMPERATURE Operates with water temperature as low as 105°F

without condensing

Heat Exchanger ƒ ASME Inspected and Stamped

Gas Control Train ƒ Manual Main Gas Shut-off Cock ƒ Main Gas Pressure Regulator ƒ Redundant Safety Shut-off Valve ƒ Control Valve ƒ Firing Mode

Temperature Controllers

B-7 Modulating B-5 Modulating, Outdoor Reset B-6 Two-stage B- Four-stage Digital Y-241 Electronic Sequencer,

160 PSIG ƒ National Board Approved ƒ Headers

Glass-lined Cast Iron – Standard Bronze – Option A-1 ƒ Finned Tubing

On/off (H4) Two-stage Firing (H3) Four-stage Firing (H9) Motorized Modulation (H2) B-6000 (H6) ƒ Fuel

1-4 Stages Y-281 Electronic Sequencer,

Copper – Standard Cupro Nickel – Option A-3 ƒ ASME Steel Tube Sheet ƒ Silicone O-Rings ƒ 60 PSIG ASME Pressure Relief Valve ƒ Temperature and Pressure Gauge

Additional Safety Controls

F-9 Low Water Cut-off Probe I-1 High Limit Control, Auto Reset S-1 Low Gas Pressure Switch S-2 High Gas Pressure Switch

Natural Gas Propane Gas ƒ Design Certified ANSI Z21.13/

(Boiler) ƒ Water Connections

CSA 4.9

Left Hand – Standard Right Hand – Option A-6 ƒ Flow Configuration

Construction ƒ Front Controls ƒ Stainless Steel Burners ƒ Polytuf Powder Coat Finish ƒ Built-in Draft Diverter ƒ Draft Inducer

Two-pass (Standard) Single-pass (Cast Iron Only)

Regulatory Agency Requirements

Controls ƒ 120V, 60Hz, 1 Ph Power Supply ƒ 120/24V Transformer ƒ 100% Pilot Shut-off/Lockout ƒ Electronic, Intermittent Ignition (IID)

Motorized Draft Inducer –

Pilot ƒ High Limit Control, Manual Reset ƒ High Limit Control, Auto Reset –

Models 3001-4001 ƒ On/Off Switch ƒ Flow Switch ƒ Economaster II Pump Time Delay

Raypak 2100-4001 — Regulatory Agency Requirements diagram (page 1)
Afb. 2 · Regulatory Agency Requirements

Catalog No.: 2000.26M Effective: 12-1-07 Replaces: 12-1-99

1-8 Stages · Option D-2

Page 2 of the Raypak 2100-4001 user manual — Catalog No.: 2000.26M Effective: 12-1-07 Replaces: 12-1-99
Pagina 2 · klik om te vergroten
Pagina 2

Raytherm - Type H Hydronic Heating Boilers Model

Raypak 2100-4001 — Raytherm - Type H Hydronic Heating Boilers Model diagram (page 2)
Afb. 3 · Raytherm - Type H Hydronic Heating Boilers Model
TUH Dimensions (inches) al Gas Width Overall Height Gas Conn. Water Conn. FlApprox. ue Dia. Shipping K Weight (Lbs.) Gas Conn. Water Conn. Fl Output A BG H 1722 61.0 68-1/4* 3**24 1400 2049 70.0 68-1/4* 3**26 1580 2460 81-1/4 68-1/42 3**28 1750 2870 92-1/2 68-1/42 3**30 1920 3280 103-3/4 68-1/42 3**32 2100

* 1-1/2” or 2” contingent on boiler type code requirements NOTE: Ratings are for elevations up to 2,000 feet. For

elevations over 2,000 feet, reduce ratings 4% for every 1,000 feet above sea level.

** 4” on one-pass option

BOILER RATE OF FLOW AND PRESSURE DROP

Raypak 2100-4001 — BOILER RATE OF FLOW AND PRESSURE DROP diagram (page 2)
Afb. 4
Model 10° ∆T No. GPM ∆P F20° ∆T 30° ∆T T GPM∆P FT GPM ∆P FT H-2100 N/A N/A17211.0 115 5.0 H-2500 N/A N/AN/AN/A 137 7.5 H-3001 N/A N/AN/AN/A 164 11.2 H-3500 N/A N/AN/AN/A 191 16.2 H-4001 N/A N/AN/AN/A N/A N/A H-2100 344 14.0N/AN/A N/A N/A H-2500 N/A N/A2055.3 N/A N/A H-3001 N/A N/A2467.8 N/A N/A H-3500 N/A N/A28711.0 191 5.0 H-4001 N/A N/A32814.8 219 6.8

N/A – Not Applicable NOTES: ƒ Values represent maximum flows and pressure drops for closed heating systems. ƒ Maximum acceptable flow through heat exchanger tubes is 200 GPM (two-pass); 400 GPM (one-pass) ƒ Single-pass heat exchangers are to be used only when flow rates exceed the allowable for two-pass

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com

Catalog No.: 2000.26M Effective: 12-1-07 Replaces: 12-1-99

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Raypak 2100-4001

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Raypak 2100-4001

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Raypak 2100-4001 handleiding-pdf

2 pagina's·221 KB·Boiler·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…