2004.1.29 SH7046 Group FP-80Q User System Interfa ce Board HS7046ECH61H User’s Manual Renesas M icrocomput er Developm ent Enviro nment System SuperH TM Family /SH7046 S eries Rev.
Cautions Keep safety first in your circ uit designs! 1. Renesas Technology Corp. put s the maximum e ffort int o making semi conductor pr oducts better and more reliable, but the re is always the possibility that trouble may occur with them. Trouble with semi conductors may l ead to personal i njury, fire or property dama ge.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufa ctured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e boards determined to be defe ctive in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or limitatio n of implied warranties or liabilit y for incidental o r consequential d amages, so t he ab o ve limitation or excl usion ma y not appl y to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have ot her rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface board. • KEEP the user's manual handy for future reference. Do not atte m pt to use the user system interface bo ard until you fully under stand its mec ha ni s m.
V W ARNING Observe the pr ecautions listed below. Failure to do so will result in a FIRE HA ZARD and will damag e the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric shock pr evention and qualit y assurance.
i Preface The HS7046ECH61H is a u ser sys tem in terface board that conn ects a user sy stem for the S H7046 FP-80Q packag e to the SH7046 E6000H em ul ator (HS7046EPH60H).
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User System Interf ace Board to User System .
1 Section 1 Configuration Figure 1 and table 1 sh ow th e configu ration and compon ents of the u ser system interface board f or the FP-80Q packag e. Please make sure y ou hav e all of these com ponents w hen un packing. Socket cover Screws (M2.0 x 8 mm) with flat washers EV-chip board Board User system Spacer IC socket Screws (M2.
2 CAUTION Use an IC149-080- 017-B5 socket (manuf actured by YAMAICH I ELECTRONICS Co., Ltd.) for the FP-80Q package IC socket on the user syst em. Table 1 HS7046ECH61H Compon ents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Board to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
4 2.1.2 Installing Cable Hea d CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC sock et for an FP-80Q packag e on the user sy stem with pin 1 on the us er system interface board, an d insert the user sy stem interface board into th e IC socket on the u ser system , as shown in figure 2.
5 Screws (M2.0 x 12 mm) with flat washers Pin 1 Board IC socket (IC 149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 2 Connecting User System Interface Board to User S.
6 2.2 Connecting User System Interface Board to EV-Chip Board W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
7 Connector No. UCN1 UCN1 UCN2 UCN2 Board EV-Chip Board Connector No. Board Connector No. EV-chip board Spacer User system Figure 3 Connecting User System Interface Board to EV-Chip Board.
8 2.3 Recom me nded Dim ensions for User System M ount Pad ( Footprint) Figure 4 show s the recom m ended dimens ions for the m ount pad (f ootprint) for the us er system w ith an IC socket f or an FP-80Q packag e (IC149-080- 017-B5: m anuf actured by YAMAIC HI ELECTRONICS C o.
9 2.4 Dim ensions for EV-Chip Boar d and User Syste m Inter face Board The dimens ions for the EV- chip board and the u ser system interface board are show n in figure 5. 140.0 19.5 31.0 33.5 16.0 100.0 116.0 92.0 69.0 29.5 5.0 34.5 Unit: mm Tolerance: ±0.
10 2.5 Resultin g Dimensions after Con necting User System Interf ace Board The resulting dim ensions, af ter connecting th e user system interface board to th e user system , are shown in figure 6. Unit: mm Tolerance: ±1.0 mm User system EV-chip board IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co.
11 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
12 MCU (SH7046) Screws (M2.0 x 8 mm) with flat washers Socket cover Pin 1 User system IC socket (IC 149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co.
13 Section 4 Verifying Operation 1. Turn on the em ulator accordin g to the procedures described in the SH7046 E6000H Em ulator User's Manual (HS 7046EPH60HE).
14 To use the crystal oscillator mounted on the EV-chip board Install a crystal oscillator into the crys tal oscillator terminals on the EV-chip board.
15 Section 5 Notice 1. Before connectin g any parts or cables, make su re that pin 1 on the both sides are correctly aligned. 2. Do not apply excessive force to the u ser system interface board w hile it is con nected to the user system .
SH7046 Group FP-80Q User System Interface Board HS7046ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
SH7046 Group F P-80Q User Sy stem Inte rface B oard HS7046E C H61H U ser’ s Manual REJ10B0040-0400H.
Een belangrijk punt na aankoop van elk apparaat Renesas SH7046 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Renesas SH7046 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Renesas SH7046 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Renesas SH7046 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Renesas SH7046 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Renesas SH7046 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Renesas SH7046 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Renesas SH7046 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.