Gebruiksaanwijzing /service van het product RSNA-B Series van de fabrikant Rheem
Ga naar pagina of 40
FORM NO. S1 1-933 REV . 2 Supersedes Form No. S1 1-933 Rev . 1 RSNA-B SUPER HIGH EFFICIENCY 1 3-SEER SERIES NOMINAL SIZES 2-5 TONS [7 .0-1 7 .6 kW] P ACKAGE A IR C ONDITIONERS.
2 T ABLE OF CONTENTS Unit Features & Benefits ..............................................................................3-4 Model Identification Options ..........................................................................5 - 6 General Data RSNA-B Series .
3 UNIT FEA TURES & BENEFITS—RSNA-B These qualit y feature s are inc luded in the Rhe em P acka ge Air Conditioner 5.
4 UNIT FEA TURES & BENEFITS—RSNA-B SERIES 1. All models feature Copeland ® Scroll ® compressors for maxi- mum efficiency and quiet operation. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes.
R S N A — B 036 J K 010 X X Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat .
6 OPTIONS—RSNA-B SERIES Option Code Side Flow AA No Option AK x F A CT OR Y INST ALLED OPTION CODES Example: RSNA-B036JK000 XX (where XX is factory installed option) Example: No Options RSNA-B036JK000 Example: Options with Sideflow RSNA-B036JK000AK Note: Factory installed economizer is not available on these models.
7 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B024JK B030JK B036CK B036JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 24,800 [7.27] 31,200 [9.
8 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B042CK B042JK B048CK B048JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 42,500 [12.45] 42,500 [12.
9 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B060CK B060JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 60,000 [17.58] 60,000 [17.58] EER/SEER 2 11.1/13 11.1/13 Nominal CFM/ARI Rated CFM [L/s] 2000/1850 [897/873] 2000/1850 [897/873] ARI Net Cooling Capacity Btu [kW] 58,000 [16.
10 GENERAL DA T A—RSNA-B SERIES NO TES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat.
11 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] DR ➀ .
12 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] DR ➀ .
GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] DR ➀ .
INDOOR AIRFLO W PERFORMANCE—208 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed RPM 730 775 820 865 905 940 0.
15 AIRFLOW PERFORMANCE—RSNA-B SERIES INDOOR AIRFLO W PERFORMANCE—230 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil Bl.
ELECTRICAL DA T A – RSNA-B SERIES Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size 16/16 20/20 Maximum Overcurrent Protection Device Size 25/25 Compressor Motor No. 1 Volts 208/230 Phase 1 HP 2 1/6 RPM 3450 Amps (RLA) 10.4/10.4 Amps (LRA) Unit Information Unit Operating Voltage Range 54/54 187-253 Condenser Motor No.
B024JK No Heat — — 16/16 20/25 20/25 A10J 24.57/32.76 34.6/40.0 45/52 45/45 60/60 A05J 12.28/16.38 17.3/20.0 24/27 25/25 30/30 44/50 45/50 — — — — — 16/16 20/25 20/25 22/25 25/25 — — — RXQJ- Heater Kit Nominal kW Heater KBTU/Hr @ 208/240 V Heater Amp.
30% 2% 21% 2% 29% 2% 20% 2% CORNER WEIGHTS % OF TO T AL UNIT WEIGHT THERMOST A T WIRING ENTRANCE ELECTRICAL POWER ENTRANCE BLOWER/ EV APORA T OR ACCESS P ANEL SIDE SUPPL Y DUCT OPENING SIDE RETURN DUC.
52 7 / 16 " [1332 mm] FIL TER ACCESS P ANEL (FOR UNIT MOUNTED FIL TER ACCESSOR Y BLOWER/ EV APORA TOR ACCESS P ANEL OUTDOOR COIL PROTECTIVE GRILLE 25 5 / 16 " [643 mm] 10 3 / 16 " [259 mm] 4 3 / 4 " [121 mm] 5 1 / 16 " [129 mm] 1 1 / 8 " [28.
20 TYPICAL INST ALLA TIONS.
COMMON SUPPL Y/RETURN CONCENTRIC AIR DIFFUSER SUPPL Y AIR/PERFORMANCE NO TE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.
DUCT AD APTERS RECT ANGULAR T O R OUND TRANSITIONS (DO WNFLO W) RXMC-CA03 RXMC-CA02 [ ] Designates Metric Con versions 22 ACCESSORIES.
[ ] Designates Metric Con versions RXRE-CAA30 (3 P osition) Provided with enthalpy control, and mixed air sensor . Settings include fully open, fully closed and adjustable mid point.
CFM [L/s] RSNA-B 680 [321] RSNA-B 850 [401] RSNA-B 1020 [481] RSNA-B 1190 [562] RSNA-B 1275 [602] 1500 [708] 1400 [661] 1200 [566] 1000 [472] 800 [378] 1650 [779] 1540 [727] 1320 [623] 1100 [519] 880 [415] Minimum Airflow Model No. Nominal Airflow Maximum Airflow 510 [241] RSNA-B 600 [283] 660 [311] Airflow Pressure Drop, Inches W .
DUCT AD APTER SIDEFLO W SQU ARE T O R OUND TRANSITION RXMC-B A01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation.
RXSG-AAA 14 (1 4" [356 mm] High) RXSG-AAA08 (8" [203 mm] High) R OOFCURB (Full P erimeter) RXSG-AAA08, RXSG-AAA 1 4 and RXSG-AAA24 for RSNA-B Series Hinged corners make for fast, easy set-up. NO T f or use with RQKA/RQLA/RQMA P acka ge Heat Pumps.
R OOFCURB (Full P erimeter) (Cont.) [ ] Designates Metric Con versions RXSG-AAA24 (24" [610 mm] High) 27 ACCESSORIES.
[ ] Designates Metric Con versions P A CKA GE AIR CONDITIONERS & GAS/ELECTRIC P A CKA GE UNITS R OOFCURB INST ALLA TION (Full P erimeter) OLD MODEL OLD CURB MODEL NEW MODEL TO OLD MODEL ROOFCURB A.
LIFT KIT—MODEL NO . RXML-A01 The lift kit is intended for temporary installation while the unit is being lifted into position. Kit includes 4 lift brackets.
W ARNING ONL Y ELECTRIC HEA TER KITS SUPPLIED BY THIS MANUF ACTURER AS DESCRIBED IN THIS PUBLICA TION HA VE BEEN DESIGNED, TESTED, AND EV ALU A TED BY A NA TIONALL Y RECOGNIZED SAFETY TESTING A GENCY FOR USE WITH THIS UNIT .
31 WIRING SCHEMA TICS—RSNA-B SERIES.
32 WIRING SCHEMA TICS—RSNA-B SERIES.
33 WIRING SCHEMA TICS—RSNA-B SERIES.
34 WIRING SCHEMA TICS—RSNA-B SERIES.
35 WIRING SCHEMA TICS—RSNA-B SERIES.
36 WIRING SCHEMA TICS—RSNA-B SERIES.
37 NOTES.
38 NOTES.
39 NOTES.
Before pr oceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Pro vincial, and Local codes, regulations, and practices.
Een belangrijk punt na aankoop van elk apparaat Rheem RSNA-B Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Rheem RSNA-B Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Rheem RSNA-B Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Rheem RSNA-B Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Rheem RSNA-B Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Rheem RSNA-B Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Rheem RSNA-B Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Rheem RSNA-B Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.