SAFETY SAFETY PRECAUTIONS PRECAUTIONS GB
ADDITIONAL FOR NORTH AMERICA AND CANADA: This monitor must NOT be permanently mounted to the building structure. It must be mounted in such a way that it can be removed using basic tools. The power supply cord must NOT be attached to the building surface. The power supply cord must NOT be routed through walls, ceiling, floors, or other similar openings in the building structure. The power supply cord MUST be positioned so as to prevent physical damage.
Do not allow anything to rest on the power cord. Do not locate this LCD monitor where the cord will be damaged by people walking on it.
Do not overload wall outlets and extension cords as this can result in fire or electric shock.
A suitable socket outlet must be provided near to the monitor and shall be easily accessible Do not place this LCD monitor near any heat sources such as radiators, heaters, stoves and other heat-generating products (including amplifiers). Do not place your LCD monitor on an unstable stand, shelf or table. Serious injury to an individual, and damage to the LCD monitor may result if it should fall. Your sales person can recommend approved wall mounting kit. A special wall mounting kit is available for this model.
This LCD monitor should be operated only from the type of power source indicated on the monitor or as indicated in the Operating Instructions. If you are not sure of the type of power supply, consult your sales person or your local power company.
This equipment is fitted with an approved mains lead and an approved non rewireable UK mains plug. To change a fuse in this type of plug proceed as follows:
For added protection it is strongly recommended that this LCD monitor is supplied via an approved earth fault protection device.
If the fuse cover is lost or damaged the plug must NOT be used but replaced with a serviceable plug. If the fitted plug is not suitable for your socket outlets, it should be cut off and an appropriate plug fitted in its place. If the mains plug contains a fuse, this should have a rating of 13 Amp, ensure the fuse cover is correctly fitted. If a plug without a fuse is used, the fuse at the distribution board should not be greater than 13 Amp.
Do not use immediately after moving the LCD monitor from a low temperature to a high temperature environment, as this causes condensation, which may result in fire, electric shock, or other hazards. Before cleaning, unplug the monitor from the wall socket.
Do not mount near an open flame source. Open flames must never be used near this LCD monitor. This LCD monitor should not be built in or enclosed in any way, heat build up will reduce the life of the monitor.
The wires in this mains lead are coloured in accordance with the following code:
This LCD monitor should have a minimum distance of 5cm away from the wall and the monitor should have 10cm distance around the top and sides.
Blue > Neutral Brown > Live Green and Yellow > Earth
Always mount using recommended and substantial fixtures and fittings. The rear finned section around the cabinet functions as a heat sink, removing heat away from the monitor. The external surface of the cabinet (finned area) must not be covered or the airflow restricted in anyway by enclosing the LCD monitor.
Before replacing the plug cover, make certain that the cord grip is clamped over the sheath of the lead - not simply over the wires.
Do not attempt to bypass the safety purpose of the grounding type plug.
THIS UNIT IS NOT DISCONNECTED FROM THE MAINS UNLESS THE MAINS LEAD IS UNPLUGGED.
Do not apply liquid cleaners or aerosol cleaners directly onto the LCD monitor. Use a damp cloth for cleaning.
THE INSTALLER MUST MAKE SURE THE MAINS LEAD IS EASILY ACCESSIBLE.
10cm · 10cm 10cm 5cm


Decloration of Conformity: North America and Canada
Model Number : CE42LM5R Trade name : Sanyo Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 Telephone : (818) 998-7322
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interence that may cause undesired operation.
The AC Power Cord supplied with this LCD monitor meets the requirement for use in the country in which you purchase it.
AC Power Cord for the United States and Canada:
AC Power Cord used in the United States and Canada is listed by the Underwriters Laboratories (UL) and certified by the Canadian Standard Association (CSA). AC Power Cord has a grounding-type AC line plug. This is a safety feature to make sure that the plug will fit into the power outlet. Do not try to defeat this safety feature. Should you be unable to insert the plug into the outlet, contact your electrician. THE SOCKET-OUTLET SHOULD BE INSTALLED NEAR THE EQUIPMENT AND EASILY ACCESSIBLE
G reverse-engineer, decompile or disassemble the Software;
The product (meaning the equipment or appliance to which this documentation relates) incorporates Software (the software applications, utilities and modules embedded within the Product) which is owned by Sanyo or its licensors. Before using the product, please read the End-User License Conditions detailed below. If you do not agree to the terms and conditions of the End-User License, Please do not proceed to use the Product- repack the Product unused and return it to your supplier together with proof of purchase for a full refund. By using the product, you agree to be bound by the terms and conditions of the End-User License.
G make the Software (or any part of it) available, or permit its
redistribution, for use with any computer hardware other than the Product; or rent, lease, gift, loan, sell, distribute or transfer possession of the whole or any part of the Software.
This license is effective until terminated. This license will terminate automatically without notice if you fail to comply with any of its provisions.
Disclaimer
G use the Software in conjunction with any other computer
hardware other than the product;
G copy all or part of the Software;
G incorporate all (or any of) the Software into other programs
developed by (or on behalf of) you and/or used by you;

INST INST ALLA ALLA TION TION
Step : 1 Mains Connection
I Connect the display unit to VGA, BNC and Scart connector as
/DVI-D /DVI-D
required.
ensure your mains plug is easily accessible.
50Hz/60Hz. To completely switch off the mains, or when the display unit is not to be used for an extended period of time, it is advisable to disconnect the power cord from the power outlet.
DVI-D DVI-D
7 PC connection This LCD monitor has a PC connector (PC-IN D-SUB).You can connect a PC to the LCD monitor and use it as a monitor display (see page 8).This input will support a large range of resolutions (see pg12).Audio can be connected via the 3.5mm PC audio in socket.

i Please use the correct mains lead supplied with the set for your
area 3. Warning: To prevent injury, the unit must be securely attached to the wall in accordance with the installation instructions.
I INPUT selection To switch between AV1, RGB, AV2 (RGB H/V or Y, Pb, Pr) AV3, DVI or PC mode press the TV/ AV button on your remote control repeatedly or press and hold the TV/AV button for a few seconds and a selection menu will appear on screen.Use the 5 or 6 buttons to select the correct input.
9.PJ Net IN/OUT: Has the ability for PJ-NET to be connected to control the monitor using a network.
1. AV1 SCART connection 2. RGB TTL input (5V RGB signals) into SCART terminal 3. Y,Pb,Pr/ RGBHV connection (AV2) This LCD monitor has a choice of Y, Pb, Pr or RGB H/V connections. You can connect your DVD player to the Y, Pb, Pr terminals instead of using a scart lead. This can support high definition in analogue component form. RGB H/V can be used as a PC input via the BNC terminals.Both options support a large range of resolutions (page 12).
DVI-D DVI-D
IEC connector · AC Mains Outlet

TV/AV button To switch from AV1, RGB, AV2, AV3, DVI or PC mode press repeatedly or Press and hold in a few seconds, an AV selection menu appears. Select the mode you require using the
Standby To switch the monitor on and off. Also see page 7
Screen mode selector To select the screen mode, Natural, Full, Zoom, Title-in or Normal. Refer to page 10
Recall To display Input selection information and the OFF Timer if set. You can also select colour systems in AV mode as follows AUTO -> PAL -> SECAM -> NTSC3.58
MENU To enter and exit the main menu, and sub menus.
Up and down To select the next item
Level up/down To adjust the sound volume level, or enter sub menus Sound mute To mute the sound from the speakers. The sound changes as follows; Normal volume -> Mute
Picture mode selection Press the button repeatedly to select the following picture modes. Personal - Personal preference mode. Dynamic - Suitable for brightly lit rooms. Standard - Normal viewing mode. Eco - Suitable for dimly lit rooms and gives a cinema - like effect.
Bass expander To get an emphasised bass sound ON or OFF.
Surround mode selector To select the surround mode, OFF, MID, MAX
FOR EU USERS
Remote control battery installation
The symbol mark and recycling systems described below apply to EU countries and do not apply to countries in other areas of the world. Your SANYO product is designed and manufac- tured with high quality materials and components which can be recycled and/or reused.
The symbol mark means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
In the European Union there are separate collection systems for used electrical and electronic equipment, batteries and accumulators. Please, dispose of them correctly at your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
Install two "AA" 1.5 volt batteries so that the "+" and "-" marks on the batteries match the "+" and "-" marks inside the unit into the remote control handset.
buttons

Off Timer OFF/ 5-120 mins
Switching into/from standby mode The Standby mode is used for switching the LCD monitor off for short periods of time. In standby mode the monitor is switched off but is still receiving mains power.
AV2 Setting RGB, H/V / Y Pb Pr Text Language Greek/ West/ East/ Cyrillic
During menu operation the bottom of the on screen display will show which controls can be used for menu navigation. Press the MENU button to enter the main menu.
G To turn the monitor into standby mode, press the 4 button.
A sub menu is selected using the 5 or 6 button and pressing the1 button when the required sub menu is highlighted. When you have finished you can press the MENU button to exit, then the MENU button again to exit the main menu.
The blue power indicator illuminates more brightly.
G To turn the monitor ON from standby mode, press any of the
following buttons: 4, 5, 6 or 0-9 buttons.
If you find the power indicator flashing, disconnect power cord from the power outlet and contact our Service desk.
This warning is a sign to let you know that the power protection function of this TV set is now operating.
: Select : Adjust MENU : Exit
Picture menu
Menu/F button: rotate between volume, Brightness, contrast, colour, sharpness and OSD language.
Brightness Contrast Color Sharpness Preset Personal / Dynamic / Standard / ECO Noise Reduction Mid / Max / Auto / / OFF Dyn. skin tone ON / OFF Text Brightness Min / Mid / Max
Input/ OK button: switch between AV1, RGB, AV2, AV3, DVI and PC mode. e d buttons: provide up and down adjustments.
: Select : Adjust MENU : Back
4 button: To switch from display to standby mode. (to switch off completely disconnect the monitor from the power supply)

I AV2 setting Press the MENU button. Select Setting using the 5 or 6 button press the 1 button to enter. Select AV2 setting using the 5 or 6 button. Press the 1 or 2 button to select either Y,Pb,Pr or RGB H/V. Press the MENU button to exit, this automatically stores your changes. Press the MENU button again to exit the main menu.
Press the MENU button and select Sound using the 5 or 6 buttons, press the1 button to enter.
Volume Balance Bass Treble Preset Personal / Talk / Music / Normal Surround OFF / Mid / Max
: Select : Adjust MENU : Back
Select and adjust to obtain the best sound settings for your environment using the 5 or 6 and 1 or2 buttons. Press the MENU button to return to Main Menu. These settings automatically store when you exit the menu.Press the MENU button to exit menu.
: Select : Adjust MENU : Exit
Connect your PC to either PC-IN or RGBHV on the rear of the set. Once connected select PC mode or AV2 (RGBHV, see page 5 for AV2 input settings) via the v button on your remote control. The set will become a monitor for the PC. By pressing the MENU button on the remote control a menu window will appear on screen, this allows the settings to be adjusted. To adjust the Picture settings select picture using the 5 or 6 buttons on the remote control then the1 button to enter the fol lowing picture settings menu. Press the 1 or 2 buttons to adjust the Picture brightness and the same to adjust the contrast of the picture.
OSD Language English Timer
AV2 setting Y,Pb,Pr/RGB, H/V Text Language Greek/ East/West/ Cyrillic
: Select : Adjust MENU : Exit
Brightness Contrast Position Video Adjust Auto Adjust Resolution White Tone R White Tone G White Tone B
Use the 1 or 2 button to select the prefered OSD language (English, French, German, Italian, Spanish, Dutch). Press the MENU button to return to main menu.
1024 X 768 @60Hz
Native Resolution XGA / WXGA 1366 x 768
: Select : Adjust MENU : Back
Picture position changes the picture horizontally and vertically. Press the1 button to enter the sub menus, adjustment is carried out using the1 or 2 buttons on the remote control. Video adjust changes the Phase and the clock of the screen. If the picture is blurred or grainy this function will adjust it to a clearer picture, adjustment is carried out using the 1 or 2 buttons on the remote control. Auto Adjust will automatically centralize the picture by using the 1 button. This will change all the above settings automatically. Auto adjust can also be achieved by pressing the /recall button on the remote control without having to select the menu. Resolution displays the current resolution of the picture. This is for information only and cannot be adjusted. White tone: Using the 1or2 buttons it is possible to adjust the colour tone of the picture using the White tone Red(R) / Green (G)/ Blue(B). This will adjust the picture to show more or less of the chosen colour. For example if red is selected you can adjust the pro portion of red in the picture to increase or decrease using the 1 or 2 buttons. Native Resolution is used when the PC can output WXGA 1366 x 768. The setting on your Monitor set can be changed to receive XGA/WXGA signal using the1 or 2 buttons . Once the native resolution has been selected, save the settings by switching the monitor off then on using the standby button.
The Off timer will switch the monitor into the standby mode when the selected time has elapsed.
Press the MENU button. Select Setting using the 5 or 6 button press the 1 button to enter. Select Timer using the 5 or 6 button, press 1 button to enter Timer Menu. Press the 1 or 2button to change time.
: Select : Adjust : Exit
The time changes in 5 minute steps.The maximum time is 120 minutes. If you have set the off timer, a count down display appears in the corner of the screen when the recall button is pressed. i If the monitor is switched off by the standby button 4 on the
remote control or by the standby switch 4 on the back of the LCD monitor the timer settings will be cancelled.
Press the MENU button. Select Setting using the 5 or 6 button press the 2 button to enter.Select Text language using the 5 or 6 button.Press the 1 or 2 button to select West, East, Greek or Cyrillic.Press the MENU button to exit.
For Sound settings refer to sound menu (Page 8) Setting: Press the menu button on your remote control and using the 5 or 6 buttons to select Settings. The 1 button will enter the settings menu.
OSD Language English Timer AV2 setting Y,Pb,Pr/RGB, H/V Power save ON/ OFF
: Select : Adjust MENU : Exit

PC OPERA PC OPERATION / TION / INST INSTALLA ALLATION MENU TION MENU GB GB
RS232C settings
OSD Language, Timer and AV2 settings are the same as in all input modes (pg 8). Power save if turned ON will switch the monitor into Powersave mode after 1 minute if no signal is detected, the LED light will turn a brighter blue to indicate stand by. The monitor will automatically turn back on when a signal has been detected (PC input / RGBHV). Use1 or 2 buttons to select power save ON or OFF. Press the menu button twice to initiate Powersave.
This monitor can be controlled via the RS232C connector using a suitable computer/ control commands. Serial Interface Specification Transfer Specification 1. Transmission Speed: initial setting value is 19200. 2. Transmission speed can be changed via the Installation menu. (see below baud rate)
ON Program OFF Max Volume OSD ON/ OFF Winter mode ON/ OFF RC Inhibition ON/ OFF Child Lock ON/ OFF
Address 000-999 Baud Rate 9600 / 19200
The Designated RS-232C serial cable must be used for a connection to a computer and LCD monitor.
: Select : Adjust : Exit
PC COM 1
TV CONTROL PORT
This LCD monitor allows you to set up the following:-
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
N.C.
RXD
RXD TXD
TXD DTR
SG
SG
DSR
N.C
RTS
CTS
CTS
RING
N.C.
(D-Sub 9 Pin) (D-Sub 9 Pin)
The TV command is defined by one command/ one line that starts with “C” and ends with carriage return. (0x0D)
I Max Volume Select Max volume using the 5 or 6 button, use the 1 or 2 buttons to set the maximum volume required.
There are two types of commands:
Functional Execution Command e.g Co5[CR] (table on page 64) Status Read Commands e.g “CR0 [CR] (see table on page 64)
I OSD (On screen display) Select OSD using the 5 or 6 button, select ON / OFF using the 1 or 2 buttons.Selecting OFF will inhibit the OSD. To re- instate OSD, press and hold the green button on the remote control to re-enter installation menu and select OSD ON.
Setting the monitor address in RS232 mode To Access Installation mode press the green button on the remote control and hold for 5 seconds (Installation menu will appear).
I Winter mode This Function can be activated when the LCD monitor is used during cold temperature conditions, approximately 38˚F/ 4˚C or below to maintain picture performance. Using the 5 or 6 button select winter mode, once highlighted you can select ON or OFF by pressing the 1 or 2 button. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function. When in winter mode, power consumption is higher than normal standby consumption. This is entirely due to the operation of heating circuitry. We strongly recommend to turn off Winter mode when the ambient temperature is above 38˚F/ 4˚C.
ON Program OFF Max Volume OSD ON/ OFF Winter mode ON/ OFF RC Inhibition ON/ OFF Child Lock ON/ OFF
Address 000-999 Baud Rate 9600 / 19200
: Select : Adjust : Exit
Each monitor can have a specific Address for example 007, which enables the monitor to be controlled individually and will not affect other monitors connected to a controlling PC.
I RC Inhibition You can prevent unwanted remote control operation by selecting RC Inhibition. When selected an inhibit symbol will appear on screen when a button is pressed on the remote control. Select using the 5 or 6 button. Press the 1 or 2 button to select On or OFF. To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF.
Address format command The addressing format command is used for operating multiple monitor sets from a single PC via the RS232C command line. If you set your monitor address to ‘000’, it will never respond to any addressing command from the PC. If the address from the PC is ‘FFF’, all monitor sets will execute the command. The Address format command is defined by one command, one line which starts with ‘A’ and ends with carriage return.(0 x0D) The Monitor starts to decode when it receives a carriage return. (0x0D) An address is added at the top of a control command
I Child lock You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor. Select using the 5 or 6 button. Press the 1 button to select On or OFF.
Example: Functional execution command: “A001C05” [CR] means address is 001 and the control command is C05 Status read command “A001CR0”[CR] means address is 001 and command is CR0.
i Disconnecting the mains suppy before exiting installation menu will cancel the following features On program, RC inhibition, Address and Baud Rate.
The monitor can set its own address in the Installation option menu (above) The address range is 000 - 999, the default address will be 000 The baud rate indicates the unit for transfer speed of data from the PC to the monitor sets
Installation · Connection · Installation

I Screen options Today there are various transmission formats with different size ratios, eg. 4:3 ,16:9 and video formats such as letterbox.
Press the WIDE button repeatedly to select your desired setting.
i When in High Resolution (720p / 1080i) YPbPr or DVI, the picture will remain fixed in 16:9 format ‘Full size’ and may not be changed.
The whole screen is filled stretching the width.
The correct ratio is maintained with black bars on the left and right.
I Full · I Normal


Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.