NL
Sennheiser logo
Officiële handleiding

Sennheiser HDE1030

27 pagina's·584 KB·Gehoorapparaat·PDF·ENJA
Sennheiser HDE1030
Inhoudsopgave 11 secties Instructions for use · Characteristics · Versions · Putting the receiver into operation · … TonenVerbergen
Page 1 of the Sennheiser HDE1030 user manual — EZL 1030
Pagina 1 · klik om te vergroten
Pagina 1

HDE 1030

Radio frequency mono receiver for use on guided tours and in conferences.

Environmentally friendly operation with

Storage and charging in the system case

EZL 1030

colour-coded identification markers for

Versions HDE 1030-2 D 1 Two-channel receiver, switchable (Cat. no. 04026) between 36.64 and 36.72 MHz. HDE 1030-2 D 2 Two-channel receiver, switchable (Cat. no. 04027) between 37.16 and 37.82 MHz. HDE 1030-3 UK 1 Three-channel receiver, three switchable fre- (Cat. no. 04029) quencies in the range between 48 and 50 MHz HDE 1030-2 F 1 Two-channel receiver, switchable, for two (Cat. no. 04028) approved frequencies in France HDE 1030 Single-channel receiver with the following frequencies: (Cat. no. 03881) 36.64 MHz (Cat. no. 03882) 36.72 MHz (Cat. no. 03883) 37.04 MHz (Cat. no. 03884) 37.16 MHz (Cat. no. 03885) 37.82 MHz (Cat. no. 03886) 37.98 MHz HDE 1030 Single-channel rceiver, frequency chosen by (Cat. no. 03880) customer HDE 1030 F 1 Single-channel rceiver, version for an (Cat. no. 04030) approved frequency in France HDE 1030 UK 1 Single-channel receiver, version for an (Cat. no. 04031) approved frequency in the UK HDE 1030-3 Three-channel receiver, three switchable (Cat. no. 04029) frequencies (36 - 50 MHz)

Show 4 more labels / short text on this page
Characteristics · Lightweight · rechargeable accuplugs · different frequencies
Page 2 of the Sennheiser HDE1030 user manual — KEN 1030
Pagina 2 · klik om te vergroten
Pagina 2

Putting the receiver into operation

Sennheiser HDE1030 — Putting the receiver into operation diagram (page 2)
Afb. 1 · Putting the receiver into operation

Insert accuplug . Select receiver channel .

(Only for two or three-channel receivers.) Turn the receiver on and adjust the volume .

If you are not going to use the HDE 1030 for a period, please switch it off by turning the volume control off until it clicks .

Changing the identification markers To easily distinguish between receivers that have been set to different frequencies a set of colour-coded identification markers KEN 1030 can be used for labelling the different frequencies. Since the markers are inserted into the front of the receiver, the different frequencies can be clearly recognized even from a distance. This is especially advantageous when it comes to sorting the receivers after an event.

Sennheiser HDE1030 — Putting the receiver into operation diagram (page 2)
Afb. 2 · Putting the receiver into operation

Hissing noise only Transmitter is switched off

Sound is distorted Accuplug is discharged, please replace or recharge

No sound at all Accuplug is defective or transmission is disturbed

KEN 1030

After use · Fault finding

Page 3 of the Sennheiser HDE1030 user manual — Simultaneous operation of several tour guide systems
Pagina 3 · klik om te vergroten
Pagina 3
Sennheiser HDE1030 — Simultaneous operation of several tour guide systems diagram (page 3)
Afb. 3 · Simultaneous operation of several tour guide systems

Since it is possible to switch between up to three frequencies several guided tours can be conducted at the same time. Another way would be to select different preset frequencies for the receivers (see VERSIONS).

Your local Sennheiser dealer (please see attached list) will help you with the selection of frequencies.

BA 90 Accuplug As a spare, or for replacing defective (Cat. no. 03261) accuplugs.

EZL 1030-20L System case for 20 HDE 1030 receivers and (Cat. no. 03877) one hand-held transmitter SKM 1030-7. (NB: Requires NT 92 / NT 92-UK / NT 92-120.)

L 1030-10 Charging unit for recharging 10 HDE 1030 (Cat. no. 04024) receivers with inserted accuplugs. (NB: Requires NT 92 / NT 92-UK / NT 92-120.)

L 92-10 / L 92-20 Charging unit for 10 and 20 BA 90 accuplugs, (Cat. no. 03355 / 03356) respectively. (NB: Requires NT 92 / NT 92-UK / NT 92-120.)

KK 1030 Connection cable for two charging units (Cat. no. 04125) L 1030-10, L 92-10 or L 92-20. (Thus, one plug-in mains unit powers two charging units.)

NT 92 230 V plug-in mains unit with Europlug for (Cat. no. 03357) charging units EZL 1030-20L, L 1030-10, L 92-10 or L 92-20. Please order separately!

NT 92-UK 240 V plug-in mains unit with UK 3-pin plug for (Cat. no. 03359) charging units EZL 1030-20L, L 1030-10, L 92-10 or L 92-20. Please order separately!

NT 92-120 120 V plug-in mains unit with USA 2-pin plug (Cat. no. 03358) for charging units EZL 1030-20L, L 1030-10, L 92-10 or L 92-20. Please order separately!

L 90 / L 90-UK Charger for one BA 90 accuplug. (Cat. no. 03262)

Accessories

Page 4 of the Sennheiser HDE1030 user manual — Cleaning and replacing the ear pads
Pagina 4 · klik om te vergroten
Pagina 4

Cleaning and replacing the ear pads

The ear pads can be removed from the receiver and cleaned with soapy water or sterilised by using the same solution as is used by mothers to sterilise the teat of a babies bottle. Rinse under clear water, then let dry well.

Replacement ear pads can be obtained directly from your local Sennheiser agent.

Receiver frequencies HDE 1030-2 D 1 36.64 and 36.72 MHz. HDE 1030-2 D 2 37.16 and 37.82 MHz. HDE 1030-3 UK 1 3 frequencies in the range between 48.00 and 49.99 MHz. HDE 1030-2 F 1 2 frequencies approved in France HDE 1030 One of the following frequencies: 36.64 MHz, 36.72 MHz, 37.04 MHz, 37.16 MHz, 37.82 MHz, 37.98 MHz HDE 1030 Frequency chosen by customer HDE 1030 F 1 Frequency approved in France HDE 1030 UK 1 Frequency approved in the UK

Nominal deviation ± 8 kHz AF frequency response 50 - 8000 Hz Maximum sound pressure level at 1 kHz approx. 112 dB THD at nominal deviation and 1 kHz < 1.5 % Signal-to-noise ratio at nominal deviation and 500 µV antenna voltage > 57 dB (CCIR 468, peak deviation) > 68 dBA (DIN 45 500) Power supply BA 90 Accuplug Current consumption 7 mA Operating time approx. 8 hours Dimensions (in mm) / Weight 206 x 136 x 22,5 / 55 g Supply schedule 1 Receiver HDE 1030 1 Accuplug BA 90

Subject to alterations.

Technical data

Vraag stellen over de Sennheiser HDE1030

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Sennheiser HDE1030

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Sennheiser HDE1030 handleiding-pdf

27 pagina's·584 KB·Gehoorapparaat·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…