OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035- 80749-00.
TA BLE OF CONTENTS A C880 B e f o r e U s i n g t h e A C 8 8 0 ..................... 2 S a f e t y P r e c a u t i o n s .......................... 2 U s i n g t h e A C 8 8 0 ........................... 3 S e t u p ..................................
Page 2 BEFORE USING T HE A C880 Check for any shipping damage. Place a claim with carrier if damage is disc overed. DO NOT USE A DAMA GED UNIT. Complete and retur n the Warr anty Card to ac tivate te chnical s upport ser vice and w arra nty coverage.
Page 3 USIN G T HE A C880 Note: The purpose of this discus sio n is to fa m iliarize the user with t he features and functions of the AC880 Refrigerant Handling Station.
Page 4 SETUP 1 Low Pressure Gauge 7 Oil Charge - High Side 13 Fill Port 2 Keypad 8 Red Hose - High Side 14 Refrigerant Cylinder 3 Power Switch 9 Blue Hose - Low Side 15 Y ellow Hose w/Anti-blowback 4 .
Page 5 N N N N N N N N N N N N EXTREMELY IMPOR TA NT N N N N N N N N N N N N Always connect Y ellow Hose (15) to Cylinder (14) first and then connect other end of hose with anti-blowback valve to Fill Port (13) on AC880. WEIGHT = XX.X LB AUTOMA TIC ? # >>>> WEIGHT = XX.
Page 6 WEIGHT = XX.X LB AUTOMA TIC ? # > WEIGHT = XX.X LB RECYCL E ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER CHECK HO SES START ? # ENTER WEIGHT = XX.
Page 7 DRA IN RECOVERED OIL Oil is separated from the recove re d refrigerant and MUST be removed following EACH Recover/ Recycle procedure to determine the amount (if any ) necessary to add into the A/C Sy stem as follows: Note: The AC880 must be connected to pow er source.
Page 8 WEIGHT = XX.X LB AUTOMA TIC ? # >> WEIGHT = XX.X LB VACUUM ? # ENTER * A/C HAS PR ESSURE GO TO RECY CLE # ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < .
Page 9 WEIGHT = XX.X LB AUTOMA TIC ? # >>> WEIGHT = XX.X LB CHARGE ? # ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER WEIGHT = XX.X LB CHARGI NG CHARG E COMP LETE EVAC HOS ES # ENTER CHA RGE 1.
Page 10 WEIGHT = XX.X LB AUTOMA TIC ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER ENTER CH ARGE AMOUNT = XX.
Page 11 WEIGHT = XX.X LB COMPRE SSOR OFF * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE # TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER WEIGHT = XX.
Page 12 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # ENTER FILTER H OURS= XX.X HOU RS > TOTAL R ECYC LED= XXXX.X K G > TOTAL C HARG ED= XXXX.X K G > A CCESS ST ORED DA TA 1. Set up the AC880 and t urn the Main Power Switch ON.
Page 13 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # Calibration Switch WEIGHT = XX.X LB CHARGI NG > OVER CH ARGE AMOUNT = X.XX KG # >< ENTER SET OVER CHA RGE A MOUNT 1. Remove the front panel of the AC880.
Page 14 SCHEDULED MA INT ENA NCE DA IL Y... Che ck the oil le vel in t he Vacuum Pump while the pump is running. The Vacuum Pum p Oil Level Sight Glass is visible thr ough a hole in the Lower Rear Panel of the AC880. The oil l evel s hould be at the “half-way” point of the glass.
Page 15 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 360-81555-00 Manifold Assy 880 120V 2 024-80037-00 Contactor ½ HP (120V) 3NO/1N C 3 024-80066-00 Rocker Swi tch SPDT Visired N on-lig hted 4 360-803.
Page 16 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 026-80077-00 Combo Filter 3/8 Fl are (Long) 2 360-81192-00 Compressor Inlet Tube Assy 3 360-81197-00 Accumulator Assy 4 360-81356-01 Compressor Assy .
Page 17 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 024-80040-00 Rocker Swi tch SPDT (on-on) Amber 125V 2 024-80060-01 Circuit Boar d 120V 3 026-80065-03 Gauge 30"-120 Psig 1/4 MFL 3.
Page 18 T ROUBLESHOOTING FILL CYLINDER PROCEDURE 1) The cy linder of new refrigerant should be at ambient temperature or great er for best performance of the Fill Cylinder procedure. Make sure the cy linder was not recently moved from an air-conditi oned storage ro om to a w arm w ork a rea .
Een belangrijk punt na aankoop van elk apparaat Sharp AC880 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sharp AC880 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sharp AC880 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sharp AC880 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sharp AC880 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sharp AC880 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sharp AC880 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sharp AC880 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.