AF-S80CX AF-R80CX AF-R85CX ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL PAGE CONTENTS This INSTALLATION AND OPERATION MANUAL explains the proper use of your new Sharp Air Conditioner. Read these instructions carefully before installing or operating your air conditioner.
2 To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit.
3 SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective wo.
4 INST ALLA TION INSTRUCTIONS Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. The mounting kit is designed for wooden sill double or single hung sash-type windows.
5 11 10 9 8 6 7 3 4 5 1 2 11 10 9 8 7 6 5 4 3 2 1 ACCESSORIES No. Accessories Q'ty Right closure assembly 1 Left closure assembly 1 Window sash foam seal 1 1.
6 Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels. Secure the right and left closure to the cabinet with six of the provided screws. (L= 13 / 32 ", 10mm) 2 3 Open the window sash and place the air conditioner on the sill.
7 1/2 inches (13mm) Indoor side Indoor side 7 8 Secure the top angle of the unit and the top of the closure assemblies to the sash with three of the provided screws. (L=1", 25.4mm) And secure the bottom of the closure assemblies to the sill with two of the provided screws.
8 IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manua l. • Make sure the unit is the correct capacity for the area you want to cool.
9 PRECAUTIONS • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for protection.
10 P ARTS NAMES UNIT CONTROL P ANEL 1 Front Cabinet 2 Air Inlet (Indoor Side) 3 Horizontal Louvers 4 Vertical Louvers 5 Air Outlet (Indoor Side) 6 Control Panel 7 Rear Cabinet 8 Air Inlet (Outdoor side) 9 Filter (Pull the filter handle to the right to remove.
11 HOW TO OPERA TE --- Lower temp. --- Raise temp. Touch POWER ON/OFF pad. • The unit is preset at 74 ° F and HIGH COOL. This will show in the display when the power is first turned on. • POWER indicator and SELECTOR in- dicator (COOL) will light.
12 POWER ON/OFF F hr SELECTOR TIMER ON/OFF ENERGY SAVER COOL / FAN TEMP SELECTOR indicator SELECTOR pad T O CHANGE F AN SPEED AND OPERA TION MODE During operation Touch SELECTOR pad and select the operation mode and fan speed. • SELECTOR indicator and display will light in order as you touch.
13 HOW TO OPERA TE ENERGY SA VER T O CHANGE AIR FLOW DIRECTION Horizontal louvers Adjust UP/DOWN air flow The horizontal louvers are used to adjust the UP / DOWN direction of air flow, and the vertical louvers are used to adjust the LEFT / RIGHT direction of air flow for uniform and efficient cooling of the room.
14 HOW TO OPERA TE ON TIMER OPERA TION (If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above.) 1 Touch the TIMER ON/OFF pad to set the delayed start time. • The time setting will change as you touch the pad.
15 HOW TO OPERA TE OFF TIMER OPERA TION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.
16 Remove the battery compartment cover. Insert the batteries in the compartment, making sure the and polarities are properly aligned. Replace the cover. HOW TO OPERA TE INST ALLING BA TTERIES Use two size-AAA (R03) batteries. Battery compart- ment cover NOTES: • The battery life is approximately one year with normal use.
17 POWER TEMP. TEMP. SELECTOR SET TIMER/OFF ON/OFF • The time setting will change as you push the button. The display will change as follows; • The last OFF time setting is memorized by the unit and will appear on the display when the button is pushed.
18 CLEANING AND MAINTENANCE CLEANING THE FIL TER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter before starting the unit.
19 BEFORE CALLING FOR SER VlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit p.
SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TINSEA 292 JBRZ 01LO TL 1.
Een belangrijk punt na aankoop van elk apparaat Sharp AF-R85CX (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sharp AF-R85CX heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sharp AF-R85CX vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sharp AF-R85CX leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sharp AF-R85CX krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sharp AF-R85CX bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sharp AF-R85CX kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sharp AF-R85CX . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.