The information in this document contains general descriptions of the technical opti- ons available, which do not always have to be present in individual cases.
The required features should therefore be specified in each individual case at the time of closing the contract.
The device conforms to the EU guideline 1999/5/EG, as attested by the CE mark.
This device has been manufactured in accordance with our certified envi- ronmental management system (ISO 14001). This process ensures that en- ergy consumption and the use of primary raw materials are kept to a mini- mum, thus reducing waste production.



Figure 2-1 optiPoint 500 entry 2-4 Figure 2-2 optiPoint 500 economy 2-5 Figure 2-3 optiPoint 500 basic 2-6 Figure 2-4 optiPoint 500 standard 2-7 Figure 2-5 optiPoint 500 advance 2-8 Figure 2-6 Power supply to BLF 2-12 Figure 3-1 Keypad and control panel (optiPoint 500 standard) 3-1 Figure 3-2 Jacks on the underside of the telephone (optiPoint 500 advance) 3-3 Figure 3-3 optiPoint 500 entry, economy block diagram 3-7 Figure 3-4 optiPoint 500 basic, standard and advance block diagram 3-8 Figure 4-1 Private network termination units 4-1 Figure 5-1 Jacks on the underside of the telephone (optiPoint 500 advance) 5-3 Figure 5-2 Recorder adapter 5-12 Figure 5-3 Connection example: host, SPA, Client, 2 SNG - Power supply unit dependent on the configuration5-14 Figure 7-1 System connection of optiPoint IPadapter 7-2 Figure 7-2 Overview: connecting an optiPoint IPadapter to the terminal 7-3 Figure 7-3 Overview: connecting an optiPoint IPadapter to the system 7-4 Figure 7-4 Electrical connection of the optiPoint IPadapter 7-4 Figure 7-5 Faults shown on optiPoint display 7-23 Figure 7-6 Error codes for configuration settings 7-24 Figure 7-7 WEB access to the IPadapter 7-32 Figure 7-8 WEB page administration 7-33 Figure 7-9 IP address and routing 7-34 Figure 7-10Settings in Assistant Office 7-35 Figure 7-11optiPoint IPadapter homepage 7-36 Figure 7-12WEB page administration 7-37 Figure 7-13IP address and routing 7-38



Table 2-1 Features of optiPoint 500 entry 2-4 Table 2-2 Features of optiPoint 500 economy 2-5 Table 2-3 Features of optiPoint 500 basic 2-6 Table 2-4 Features of optiPoint 500 standard 2-7 Table 2-5 Features of optiPoint 500 advance 2-8 Table 2-6 Headsets 2-17 Table 2-7 Environmental conditions 2-20 Table 2-8 UP0/E interfaces: technical data 2-21 Table 3-1 Telephone test for HiPath 4000/Hicom 300 H 3-4 Table 7-1 Pin assignment 7-4 Table 7-2 FTP parameters 7-14 Table 7-3 Error messages 7-15 Table 9-1 opiPoint 500 models 9-1 Table 9-2 optiPoint 500 adapters 9-1 Table 9-3 optiPoint 500 without HS 9-2 Table 9-4 optiPoint 500 handset with/without logo 9-3 Table 9-5 optiPoint 500 more spare parts 9-3 Table 9-7 Order addresses 9-7 Table 9-8 Intranet addresses 9-9



Faulty terminals and adaptors can be debugged on site by exchanging components/adaptors or replacing individual faulty elements, such as handsets, cords, covering panels, etc.
Setting Up the Equipment
The equipment is set up by the user or service technician. Training or orientation on how to use optiPoint500 device parts is not neccessary.
A mains socket may be necessary for operating telephones and options, depending on the scope of the configuration. If more telephones are to be added later on, make sure that an adequate number of mains sockets are available for connecting the required local power supply units.
Damage to the Equipment
Only use tools and testers suitable for the job. Do not put devices with external damage into service.
Lay the power and connection cables in such a way as to avoid accidents (no tripping) and damage to the cables.
Troubleshooting and Replacing Boards
Protecting Electrostatically Sensitive Devices
To protect electrostatically sensitive devices (ESD):
General Service Information · Service Concept · Laying Cables

General Service Information Nur für den internen Gebrauch
The following symbols are used in this manual to identify possible sources of danger.
Data Protection and Data Security
7 Hazards that can cause damage to the hardware and software and even destroy it.
4 Electrostatically sensitive devices
In Germany, the processing and use of personal data are subject to various regulations, includ- ing the regulations of the Federal Data Protection Law (Bundesdatenschutzgesetz = BDSG). For other countries, please follow the appropriate national laws.
The aim of data protection is to protect the rights of individuals being affected by use of their personal data.
Guidelines for Members of Siemens Staff
Siemens staff are required to observe business and data secrecy as a result of the company’s work rules.
In order to ensure that the statutory requirements during service - whether during "on-site ser- vice" or during "remote service" - are consistently met, you should always observe the following rules. You will not only maintain the interests of your and our customers, you will also avoid personal consequences.
Safety Symbols · Helpful suggestions · Using Personal Data

Nur für den internen Gebrauch General Service Information
Guidelines for Using Data
Conscious action helps maintain data protection and data security:
Safety Symbols

General Service Information Nur für den internen Gebrauch
Safety Symbols

OptiPoint 500 telephones are designed to facilitate access to the features of HiPath 3000/Hi- com 150H and HiPath 4000/Hicom 300/300H. See the chapter on “Startup” for configuration information.
The operating principle is characterized by three dialog keys, which in conjunction with the dis- play, facilitate interactive user prompting. In addition, the key LED principle indicates activated functions.
The numerous control functions are clearly laid out in submenus and can be read on the display (excluding "entry" model). Features can also be selected directly via the service key using a code. Important functions can be programmed on individual function keys.
Function keys with LEDs 8 12 12 12 19
Adapter slots 1 1 2
Headset port (121 TR9-5) •
Display (characters) 2 x 24 2 x 24 2 x 24 2 x 24
Display background lighting •

optiPoint 500 Features at Hicom/HiPath
Features when Connecting to Hicom and HiPath
Optiset E IDs for telephones and options must be used when connecting optiPoint500 to one of the following systems:
Additional Features when Connecting optiPoint 500 to HiPath 4000
Product Description · Features

Modules (Add-On Components) and Adapters
The optiPoint 500 operating panel (basic model and later versions) can be expanded
– using key modules with function keys
– a signature module or
– a busy lamp field
By using adapters in conjunction with telephones, specific workstation requirements can be satisfied.
Additional devices can be directly connected to the workstation (e.g. PC, fax machines, tel- ephones, headsets) by simply adding different adapters to the underside of the telephone.
– only possible with Windows 98 SE or Windows 2000 with USB support
– optiPoint 500 USB client interface, conforming to USB Specification 1.1
– USB cable with right-angle plug available for optiPoint 500 basic/standard/advance
– integrated USB1.1 interface replaces optiset E control/data adapter for CTI functions
– integrated USB1.1 interface replaces optiset E with ISDN adapter for modem, NDIS- WAN miniport, and CAPI applications
CallBridge for Data offers NDISWAN miniport, CAPI 2.0, and ComPort/modem interface for data applications
7 No firewall has been implemented - there could be a security risk if both a LAN port and CallBridge for Data are installed.
Product Description · Configuration Notes

2.3.1 optiPoint 500 entry
For stations at which a display is not required (e.g. lifts, entrance halls, etc.)


Figure 2-1 optiPoint 500 entry
– open listening (not speakerphone mode)
Table 2-1 Features of optiPoint 500 entry



Figure 2-2 optiPoint 500 economy
Table 2-2 Features of optiPoint 500 economy

Figure 2-3 optiPoint 500 basic
– optiPoint 500 Key Module
– optiPoint 500 Signature Module
Table 2-3 Features of optiPoint 500 basic

Figure 2-4 optiPoint 500 standard
– optiPoint 500 key module
– optiPoint 500 signature module
Table 2-4 Features of optiPoint 500 standard



Figure 2-5 optiPoint 500 advance
19 function keys with LEDs Full duplex speakerphone mode with echo sup- pression for room adaptation
Tiltable alphanumeric LCD display with 2 lines and 24 characters per line. additional with background lighting, remains lit for approx. 5 s.
– optiPoint key module
– optiPoint signature module
3 dialog keys for interactive user prompts: Yes, Back, and Continue
2 adjustable keys (plus/minus) for ringer vol- ume, ringer pitch, handsfree quality, alerting tone and display contrast
Suitable for wall mounting
Table 2-5 Features of optiPoint 500 advance
If optiPoint 500 advance is connected to Hicom or HiPath 3000 or AllServe 150, only 12 func- tion keys can be configured via Hicom/HiPath. The remaining function keys can be configured as call destination keys via the optiPoint500 ad- vance menu.
Product Description · Telephones · Controls Special Features

Adapters facilitate flexible expansion of the telephone workstation at optiPoint 500 basic, stan- dard and advance system telephones, by means of individual add-on components.
Product Description · Module Options · Configuration Notes


The key module on the basic, standard and ad- vance models is used for saving call numbers and functions (e.g. callback, conference, last number redial, etc.)
It features:
One of the keys is assigned the shift function. 30 name destination keys can be programmed using the shift key.
Max. 2 key modules can be connected to optiPoint 500.

The BLF is a key module for optiPoint 500 and 600 that can be connected to the telephone over an 8-pin RJ45 communications port.
It can be used in the HiPath 3000/Hicom 150E/H and HiPath AllServe 150 systems and has the same functions as the existing BLF on optiset E telephones.
The BLF on the basic, standard and advance models allows phone numbers and functions to be saved (e.g. callback, conference, last number redial, etc.)

2.4.2.1 Power Supply
The BLF has its own local power supply. If you want to connect two BLFs, you need only one local power supply for them both (i.e. the power supply of the first BLF can be used for the sec- ond BLF as well).
The BLF uses the same power supply (power supply unit 2x35V) and connector as the optiPoint 500 a/b adapter (also see chapter “Accessories“ --> “Mains adapter“).
The output of power supply must be connected directly with the optiPoint BLF.
Product Description · Module Options · It has


Figure 2-6 Power supply to BLF
When connecting the BLF the configuration should be checked to ensure that it cor- responds with the telephones/auxiliary modules which are connected..
Product Description · Module Options

2.4.2.2 Connection to the Terminal
The following connection configurations A - D are possible:
B
optiPoint BLF optiPoint BLF
optiPoint BLF optiPoint BLF
You can also connect the BLF to the terminal first in combination C and D in connection with a key module.
With releases lower than 3.0, it is not possible to use an optiPoint 500 advance with the connection configurations C and D.

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
SPI master out/slave in
nc + 3,3V nc DGND SPI clock SPI master in/


The optiPoint 500 signature module is a chip card reader add-on device for the basic, standard and advance models.
The key module is a simple option for upgrading an existing telephone to chip card technology.
I2C Bus Memory Cards
Customized, programmable I2C cards are required for using signature modules. These can be obtained from Siemens AG: [email protected] (see Section 9.3)
Product Description · Module Options · Physical mounting

2.5.1 External Speaker/Desk Microphone
These parts feature magnetic shielding to protect magnetic data media and monitors as well as a device to protect against incoming radiation for electromagnetic compatibility (especially in conjunction with mobile phones).

To avoid feedback, position the desk microphone and the external speaker as far away from each other as possible.

LED for on/off display
The desk microphone replaces the microphone that is integrated in the telephone and assists in optimizing the "speakerphone" function in poor acoustic conditions.
If the external speaker button on the telephone is pressed, an LED lights up on the microphone to show that the microphone is now ready to record.
The microphone can be switched off by pressing the mute key. Deactivation is confirmed when the LED goes out.
optiset E External Speaker
The active external speaker enhances the speaker already integrated in the telephone and im- proves the acoustic features and is therefore most suitable for telephone conferences.
When the external speaker is connected to the power network, an LED lights up to show that is operational. The external speaker button on the telephone activates this function.
The base volume can be adjusted in line with the given room conditions using the automatic volume control key on the front of the telephone. Volume control during a call is controlled via the volume key on the telephone.


The headset replaces the telephone handset, i.e. the user’s hands are free during the call. This add-on device is particularly useful for frequent telephone users (switch operators, tele-market- ing personnel).
Connecting the Headset to an 121TR9-5 Interface
The following headsets can be connected to the optiPoint acoustic adapter and the optiPoint 500 advance telephone:
Headset Order Number Connect to
or optiPoint 500 basic with acoustic adapter
or optiPoint standard 500 with acoustic adapter
2100 Flex Boom NC Mono
2100 Flex Boom NC Duo
The acoustic adapter also supports the ex- tended cordless 121TR9-5* interface.
Spare parts and accessories, such as ear cushions, earpieces, clothing clips, adapter sets for glasses, fast-on clips, head clips, and extension cords are available from your Siemens con- sultant.

You may need to use an optiset E local power supply unit to extend the range or operate addi- tional options. The local power supply unit has two RJ11 jacks and is packaged with the con- necting cable.
If the supply voltage exceeds 21 V, all devices are reset and any calls in progress released.
Line voltage 220 (230) V
AC line frequency 47-53 Hz
Max. output voltage 50 V
Min. output voltage 30 V
Max. output current 250 mA

Primary/Client Configuration (see Section 5.5 on page 5-11)
The local power supply can be looped into the connecting line of the primary or client tele- phone.
If a local power supply is connected in front of the client telephone, the phone adapter detects this local power supply (via pins 2+5) and turns off the power to the client telephone. In this case, only the signals are received via the UP0/E interface.
If the power to the client fails, the phone adapter reactivates the power supply.
If the local power supply unit is connected in front of a primary telephone, the supplementary power is fed via a diode. Because the optiset E local power supply unit has a higher voltage, it supplies the power to the equipment.

Each telephone/key module is supplied with:
For each system order/upgrade, a CD-ROM for is supplied to the administrator via the PC net- work for provision to the user (available in 7 languages):
Further CDs can be ordered at a charge.
Up-to-date documents (CD contents) on the Internet: www.hipath.com
This tool is used for labeling the optiPoint 500 telephone keys. It offers:
optiPoint key labeling sheet order units include:
Wall brackets can be used for all optiPoint 500 telephones, apart from with add-on devices, if a USB 1.1 interface or an adapter is plugged in.
Product Description · Accessories · Order Number A31003-H8400-B990-*-6Z19

2.6.1 Asset ID
All telephones have a 32-bit asset ID, which is an electronically encoded serial number that is set in the factory during final inspection. This number, combined with the phone ID (telephone type), clearly identifies the telephone.
The asset ID is stored in four bytes, each composed of eight bits.
Significance of the bit field
Year Week Day Design Factory Test bay Serial no.
4 bits 6 bits 3 bits 3 bits 2 bits 2 bits 12 bits
LSB ** 1
* MSB = most significant bit
** LSB = least significant bit
Environmental conditions apply to all optiPoint telephones, adapters and key modules:
Ambient temperature Relative humidity
Operation 5°C to 40°C 5% to 85%
Transport (short-term) -40°C to +70°C 95% at 45°C
Storage -5°C to +45°C 5% to 95%
Table 2-7 Environmental conditions
Product Description · Technical Data

The transmission range with a 0.6 mm PVC cable is at least 1,000 meters (100 meters from primary to client device).
The feeding range can be checked via the optiPoint menu item "Service", "Line Test". This test activates all LEDs for 3 or 5 seconds (depending on the system type), turns on the ringer for 1 second, and blanks the display.
Detailed range data for the individual cable types can be found in the ICN TI Hicom 150 E/ Hi- com 300 E and in the ICCS Manual, Volume 2 (order no.: A30951-V6200-*-7620/Lieferzentrum Fürth).
The UP0/E interface is a vendor-specific ISDN interface that uses the CorNet TS protocol and a powered two-wire interface for connecting the optiPoint500 telephones.
Data transmission based on time-division multiplexing with AMI codes 250 µs frame
Bit clock 384 kHz
Net bit rate 144 kbps
Aggregate bit rate 152 kbps
Center frequency 192 kHz
Characteristic impedance at 192 kHz 100 ohms
optiPoint 500 telephones are upgraded with a USB interface (with the exception of optiPoint 500 entry). This is the basis for:
TAPI and CAPI can be used in parallel (e.g. you can receive a large e-mail or download data, etc. while setting up calls via a CTI application).
Product Description · Technical Data · UP0/E interface

Product Description · Technical Data

Startup Unpacking the Box
Before unpacking the telephone, check the box to see if there is any visible damage caused during transport. Then open the box and check its contents to make sure they are complete and undamaged.
Due to the many different kinds of varnishes and polishes used on furniture, the possibility of housing components being damaged or leaving unsightly marks cannot be completely ruled out. Siemens does not assume any liability for any damage associated with where the tele- phone set is mounted.
When setting up the telephones, make sure that they are not exposed to direct sunlight and are not in the direct vicinity of a heat source.

Function/name keys with LED
Label (covered by handset)
Figure 3-1 Keypad and control panel (optiPoint 500 standard)

Startup Nur für den internen Gebrauch
Date and Time Indicator
The software polling cycle time is 32 ms. After determining that a key was pressed, the tele- phone does not poll any other keys until the user releases the pressed key.
Pressing the Plus/Minus Key Simultaneously
A specific feature can be configured in Hicom/HiPath (e.g. volume control) when the plus and minus keys are pressed at the same time.
All optiPoint 500 telephones with displays (economy, basic, standard, advance) have a date/ time indicator. As indicated in CorNet-TS, the telephone only maintains the clock, while Hicom/HiPath are re- sponsible for setting the time, activating the telephone to display the time, and controlling the call duration timer.
Keypad Polling

Nur für den internen Gebrauch Startup Ports on the Underside of the Telephone
7 When changing or expanding an existing configuration, first unplug the host, connect the extension, and then plug the host back in.

Figure 3-2 Jacks on the underside of the telephone (optiPoint 500 advance)
RJ45 jack for · RJ11 Hicom jacks · Adapter slots

Startup Nur für den internen Gebrauch
Accessing the Telephone Test
The telephone test is started by pressing the "service key" and entering the "code number".
Menu text Action after pressing OK
91 LED Start the LED test
92 Screen Start the screen tests
93 Keys Start the key test
94 Audio Go to the audio test/submenu
941 Speaker Test the speaker volume (7 levels)
942 Handset Test the handset volume (7 levels)
943 Ringer volume Change the ringer volume (7 levels)
944 Ringer pitch Change the ringer pitch (7 levels)
945 Alerting tone Change the volume of the alerting tone (7 levels)
946 Speakerphone mode Handsfree function (3 levels): normal, loud, noisy room
940 Back Return to the audio test
95 Asset ID Display the asset ID
96 Software version Display the telephone SW version
97 Feeding range Start the feeding range test
90 Back Return to the telephone test
Table 3-1 Telephone test for HiPath 4000/Hicom 300 H
optiPoint 500 Models with Display (economy, basic, standard and advance)
– if sufficient power is being supplied, a light grey pixel pattern is visible
Telephone Tests · Code number

Nur für den internen Gebrauch Startup Telephone Tests
– if no power is being supplied, the pattern is not discernible in the display window.
Test Function Not Working
If the test function does not work, you may need to connect an additional power supply unit to the telephone. If the date and time do not appear on the screen after startup, either the telephone or the line is defective.
optiPoint 500 telephones on Hicom 300 H are recognized as optiset E IDs.
optiPoint 500 telephone Generation/recognition by Hicom 300 H optiPoint 500 entry --> optiset E basic optiPoint 500 economy --> optiset E advance optiPoint 500 basic --> optiset E advance plus/comfort
optiPoint 500 standard --> optiset E advance plus/comfort
optiPoint 500 advance --> optiset E advance plus/comfort + optiset E key module
Only HiPath 4000 V1.0 and later recognize the optiPoint 500 IDs.
HiPath 3000/Hicom 150 H
The location of the Service key and the code assignments can be freely programmed in Hicom 150 H. optiPoint 500 telephones are not recognized automatically by HiPath 3000 V3.0/V3.0 and ear- lier and Hicom 150 H; instead they are treated like optiset E telephones. optiPoint 500 advance telephones are not released for sale on HiPath 3000 Version 3.0 and earlier. Only HiPath 3000 V3.0 and later fully support the optiPoint 500 IDs.
optiPoint 500 telephone Generation/recognition by HiPath 3000/Hicom 150 H and HiPath 3000 Manager E/Hicom Assistant E Office optiPoint 500 entry --> optiset E basic optiPoint 500 economy --> optiset E advance optiPoint 500 basic --> optiset E advance plus/comfort
optiPoint 500 standard --> optiset E advance plus/comfort
optiPoint 500 advance --> optiset E advance plus/comfort + optiset E key module
HiPath 4000/Hicom 300H

Startup Nur für den internen Gebrauch
Because the optiPoint 500 advance has more function keys (4 + 15) than all optiset E tele- phones (max. 4 + 8), the system generates an optiset E advance plus/comfort with optiset E key module for the optiPoint 500 advance. This combination is also recognized by HiPath 3000 Manager E/Hicom Assistant E Office.
The 4 + 8 function keys of the optiset E advance plus/comfort and the first 7 keys of the optiset E key module are used for programming the 4 + 15 function keys of the optiPoint 500 advance.
Telephone Tests

Nur für den internen Gebrauch Startup Block Diagrams

Figure 3-3 optiPoint 500 entry, economy block diagram

Startup Nur für den internen Gebrauch

Figure 3-4 optiPoint 500 basic, standard and advance block diagram
Block Diagrams

Private Network Termination Units

optiset E distance adapter
Figure 4-1 Private network termination units
Private network termination units convert the two-wire UP0/UP0/E and U2B1Q subscriber interfac- es of the HiPath system to the user’s four-wire S0 interface.
optiset E · optiPoint 500

Private Network Termination Units Nur für den internen Gebrauch
PNT Private Network Termination
PNT converts the two-wire UP0 interface to the four-wire S0 interface and extends the range. This gives you the advantages of the S0 and S0 bus interfaces at great distances from the Hi- com system (connecting up to eight telephones and using fewer cables and system ports). The desktop model can also be mounted on the wall. Power is supplied by an optiset E local power supply unit.
The PNT E converts the two-wire UP0/E interface to the S0 interface to connect up to two S0 terminals (such as a PC and fax) to Hicom. A local power supply is available for the PNT E if the connected devices need to receive power from the S0 interface.
PNT Q converts the two-wire U2B1Q interface to the four-wire S0 interface and extends the range. This gives you the advantages of the S0 and S0 bus interfaces at great distances from the Hicom system (connecting up to eight telephones and using fewer cables and system ports).
4.4 Distance Adapter (UCON S and M) at Hicom 300/300 E and HiPath 4000
Distance adapters increase the optiPoint 500 telephone range from 1,000 m to a total of 8,000 m, depending on the cable type. The range between the optiPoint 500 distance adapter and telephone is limited to 100 m (depending on the cable type and diameter). To connect this adapter, an SLMQ line card (U2B1Q interface, 16 ports) with LAP-S and CorNet- TS must be provided in Hicom 300/300 E. Power is supplied to the distance adapter via a local power supply unit. An 8-pin RJ 45 plug is used as the mains power supply. This is the same as the plug used for PNT. The stacked UCON S or M housing is suitable for desktop installation or mounting on the wall.
Distance Adapter S (single) - UCON S
UCON S has a 6-pin RJ 11 entry and exit port. It serves as the connection between an optiPoint 500 telephone and its options via the U2B1Q interface (2-wire).
Distance Adapter M (multiple) - UCON M
UCON M is available via four 6-pin RJ 11 entry (4x U2B1Q) and exit interfaces (4x UP0/E). This adapter is used for connecting four telephones and their options.

Option Adapters and Ports
The optiPoint 500 adapter concept facilitates the flexible extension of the optiPoint 500 basic, standard and advance system telephones.
Comparison of optiset E Adapters and optiPoint Option Adapters

* Local power supply unit recommended ** Local power supply unit required

Option Adapters and Ports Nur für den internen Gebrauch
– configurations with analog adapters and ISDN adapters.
Configuration Notes · – client configurations

Nur für den internen Gebrauch Option Adapters and Ports
7 When changing or expanding an existing configuration, first unplug the host, connect the extension, and then plug the host back in.
Figure 5-1 Jacks on the underside of the telephone (optiPoint 500 advance)
You can plug adapters into slots on the underside of the telephones.
Adapter Slots · Adapter slots

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 acoustic adapter
>
A local power supply unit is required when using the acoustic adapter.
You can connect the following to this adapter:
It is intended for use with the following systems:
This model has an integrated headset port on the underside of the device.
basic standard advance

Nur für den internen Gebrauch Option Adapters and Ports optiPoint 500 acoustic adapter

1 2 3 4 5 6 7 8
for connecting speaker and mi- crophone
Floating contact (MW6/6) Headset MW8/8
Pin assignments, Desk Microphone and External Speaker: MW 8/8
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
+U GND NF Sens LS_SENS LSP NC DGND
External Speaker:
Y cable MW8/8

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 acoustic adapter
Desk Microphone:
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
The electrical values comply with FTZ 121TR9-5.
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
5.2.1 Electrical Requirements of the Headset

Nur für den internen Gebrauch Option Adapters and Ports optiPoint 500 acoustic adapter
In addition, the acoustic adapter also provides two floating contacts. This allows the control of a busy lamp and a secondary bell.
This signals the active telephone states:
An external lamp can be used to indicate these states. When the lamp lights up, one of the above-mentioned states is active. However you cannot provide a separate lamp for each of this states.
The lamp receives power from an external source rather than from the telephone itself. However, to prevent this lamp from causing irreversible damage to the optiset telephone or optiset contact adapter, the power supply must range from 24 volts to a maximum of 60 volts, and the lamp itself should not exceed 5 watts. (You can, of course, connect a relay instead of the lamp, taking care not to exceed the connection values mentioned above).
This provides the ring input status.
This contact can provide an external signaling mechanism when the telephone rings. This is important when connecting a secondary bell or similar device. Once again, observe the electrical connection values for this connector as well (24 V - 60 V, 5 W; do not connect an inductive load without surge protection). However, you can also connect a relay instead of the lamp, with this relay then controlling the 220 V secondary bell.
The “busy display“ and “door opener“ functions cannot take place simultaneously. The “door opener“ function is currently only applicable for HiPath 4000 (later also for HiPath 3000 V4.0).
Both contacts can carry the following load:
5 W with 24 V a.c. or 60 V d.c.
Contact Load

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 Analog Adapters
This type of adapter is used for connecting an analog terminal (e.g. telephone, group 3 fax, mo- dem, cordless telephone) to the system telephone.
A local power supply unit is required when using an analog adapter. Only DTMF terminals can be connected to an analog adapter (no dial pulsing).

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
RJ11 6 5 4 3 2 1
Functions

Nur für den internen Gebrauch Option Adapters and Ports optiPoint 500 Analog Adapters
– fax machines or other
– analog equipment with an analog interface
The adapter does not support the following functions:
Analog Interface · – analog telephones · – cordless telephones

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 ISDN Adapter
The ISDN adapter converts a UP0 => S0.
This permits the connection of default ISDN terminals with their own power supply unit (e.g. group 4 fax machines, ISDN data terminals, ISDN telephones as well as video communication equipment, such as a video set or video kit for example).

Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
RJ45
8 7 6 5 4 3 2 1
– cables can be a maximum of 100 meters long with a cable impedance of 75 ohms.
– They can be up to 200 meters with a cable impedance of 150 ohms according to CCITT Recommendation I.430
Functions

Nur für den internen Gebrauch Option Adapters and Ports optiPoint 500 Phone Adapter (Host/Client)
The phone adapter facilitates the connection of a second UP0/E terminal with its own power supply unit (client) for using the second B-channel.
The connected client phone can send and receive calls independently of the host telephone’s connection status.
If you need to extend the range or operate additional options a local power supply unit is required (see chapter „Local Power Supply Unit“.
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
NC AUX - UP0 - UP0 + AUX + NC
6 5 4 3 2 1
The phone adapter has a single MW6 modular connector with 4 pins that supply the interface for the client phone.
Restriction:
Range limited to 100 meters.
Functional Description

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 recorder adapter

Figure 5-2 Recorder adapter
The recorder adapter has an interface for a second headset and a recorder interface.
The way in which the headset plus adapter interacts with the telephone and the CS is described by the CorNet-TS layer 3 specification for Symphony. The CS can detect a second headset af- ter it has been plugged into this option.
When a second handset is connected, the uplink beep capability is provided by adding the beep and uplink audio during the beep. A beep detection circuit activates the uplink beep when the switch recorder generates the beep signal, thus maximizing the echo reflection attenuation. The users hear the uplink beep in the secondary tone path.
Pin 1 2 3 4
Interfaces · Headset · Interface Description

Nur für den internen Gebrauch Option Adapters and Ports optiPoint 500 recorder adapter
Pin 1 2 3 4 5 6
Ports 2 and 3 and ports 4 and 5 are connected to each other.
1 2 3 4 5 6
Headsets that are connected to the headset plus adapter must meet the same requirements as those connected to the headset adapter.
Recorders that are connected to the headset plus adapter must meet the following require- ments:
The headset plus adapter already contains an electrical isolator for the recorder port.
Recorder port · Electrical Requirements

Option Adapters and Ports Nur für den internen Gebrauch
optiPoint 500 recorder adapter


Nur für den internen Gebrauch Option Adapters and Ports

Phone Pin Nr Up0 HA HS Side out Bay out USB MW6/4 MW4/4 MW4/4 MW8/8 B2B USB Typ B 1 not asse MIN1(DGND) MIN2(DGND) MRST LPWR+ USB_VCC 2 LGND HAP HSP DGND LGND D- 3 Up0_La HAN HSN SCLK APWR+ D+ 4 Up0_La MIP1+ MIP2+ (RX_INCA) not asse DGND 5 AUX+ (TX_INCA) not asse 6 not asse SPI_CS DGND 7 +3V3 DCL 8 MTSR +3V3 9 DD 10 OPT_RESN 11 DU 12 FSC 13 SCLK 14 MTSR 15 MRST 16 OPT_CSN
not asse not assembled nc not connected (xx_xx) connection only during developement res reserved

ISDN Slave Analog Recorder Pin Nr S0 Up0 a/b 2-nd Ear Record MW8/8 MW6/6 MW6/6 MW4/4 MW6/6 1 nc 2 nc AUX- nc HOP RECP 3 SR1 Up0- TIP+ HON RECP 4 SX1 Up0+ RING nc RECN 5 SX2 AUX+ nc RECN 6 SR2 nc nc nc 7 nc 8 nc
Port Overview

Option Adapters and Ports Nur für den internen Gebrauch

Akustik Key Signature BLF Pin Nr Audio Head Contact Side in Side Out Card Power MW8/8 MW8/8 cod MW6/6 MW8/8 MW8/8 CCR MW6/6 1 MIC_POW+ HS_RXD ACT1 MTSR MRST SC_VCC nc 2 MIC_DGND DGND ACT2 +3V3 DGND SC_RSTN POW- 3 MIP MIN RING1 SC_CS SCLKO SC_CLK nc 4 MIC_SENSN HSP RING2 (VPP) nc nc nc 5 LS_SENSN HSN (RESETN) nc DGND POW+ 6 LSP MIP+ SCLK CS_OUT nc nc 7 (BOOT) +3V3 DGND +3V3 SC_I/O 8 AGND HS_TXD MRST MTSR SC_AUX
Port Overview

optiPoint 500 basic, standard and advance models are equipped with a USB interface. This provides a USB 1.1 (client) "plug and play" port on a PC with MS Windows 98SE/2000.
The USB cable (S30267-Z360-A30-*) with right-angle plug is required for connecting optiPoint 500 to a Windows PC. This cable is not supplied with optiPoint 500.
The "Callbridge TU" program is ready for downloading. It sets up the connection from the PC to optiPoint 500 and offers PC-supported telephony. The telephone user should contact his system administrator for information on installing this program. This program is not installed by default by the Siemens technician.
The documentation for CallBridge you can find under following link adress:
http://netinfo2.icn.siemens.de/e_doku/en/index.htm#hcab
CallBridge CallBridge TU

CallBridge Nur für den internen Gebrauch
Data communication with PCs over optiPoint 500 system telephones.
CallBridge for Data is a software solution for PC data communication with the new optiPoint 500 telephone family. The connection to ISDN transforms a PC into a communications workstation, especially when there is no LAN or when the LAN, without a gateway to the outside, allows data communication only within the company. CallBridge for Data sets up the access to the Internet or fax and also allows additional data communication relationships to other data devices, both in analog telephone networks and with ISDN.
It takes only one USB cable to connect the PC to the telephone. CallBridge for Data thus re- places hardware components that would otherwise be necessary, such as an ISDN card in the PC and an ISDN adapter on the modular telephone.
The delivery consists of a CD-ROM with the CallBridge for Data software and accompanying electronic documentation. The USB cable must be ordered separately.
CallBridge for Data

An IP adapter provides voice communication via LAN connections.
The optiPoint IP adapter is an external adapter for optiset E terminals, which can be configured in the following system environment:
The optiPoint IP adapter can be administered both via the telephone connected to the UP0/E port (basic settings only) and a LAN-based PC (web browser = HTTP client - all settings, e.g. Upload new firmware, Save configuration files, etc.).
Administration via telephone is essential for initial commissioning if DHCP support (Dynamic Host Configuration Protocol) is not available. DHCP support is activated by default in the case of optiPoint IPadapter. If DHCP is supported, the optiPoint IPadapter is automatically recog- nized in the LAN and can immediately be administered via the web browser.
For information on the administration of the LAN environment at Hicom Xpress @LAN, please refer to the administration manual for HiPath HG 1500/Hicom Xpress @LAN (reference no.: A31003-K5020-B811-*-7619).
IP Adapter · IP Adapter Administration

IP Adapter Nur für den internen Gebrauch
HG1500
@LAN)
@LAN)
LAN LAN
LAN
LAN LAN
HTTP client DHCP server
optiPoint IPadapter optiPoint IPadapter
‚system-side‘ mode ‚system-side‘ mode
U P0/E
300 E/H or Hicom
optiPoint IPadapter optiPoint IPadapter
300 E/H or Hicom
‚phone-side‘ mode ‚phone-side‘ mode
150 E
U P0/E
Figure 7-1 System connection of optiPoint IPadapter
>

Nur für den internen Gebrauch IP Adapter Connection to the Terminal


(A) To the terminal (B) To IPadapter A B
Connect the optiPoint IPadapter to the terminal in the following sequence (please also note the diagram "Electrical connection of the optiPoint IPadapter"):
optiPoint

IP Adapter Nur für den internen Gebrauch
Connection to the System
LAN - I/F
10 Base T UP0/E
Connect the optiPoint IPadapter to the Hicom system in the following sequence (please also note the diagram "Electrical connection of the optiPoint IPadapter"):
The optiPoint IPadapter can be operated as a desktop unit or can be mounted on the wall with a screw. The wall attachment can be found on the back of the IPadapter (point 3).


Figure 7-4 Electrical connection of the optiPoint IPadapter
PIN assignments on the IPadapter
Connector/ jack Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
UP0/E RJ11 NC DC- a(UP0/E) b(UP0/E) DC+ NC
LAN RJ 45 TDX+ TCD- RXD+ NC NC RXD: NC NC
Table 7-1 Pin assignment

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser

With the help of a PC (web browser) connected to the LAN network, you can start up/register the UP0/E telephone via the LAN. A DHCP server is necessary in order to configure the LAN settings automatically.
The following structural overview shows how you can navigate through the various web pages by clicking the relevant links.

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
The IPadapter/UP0/E telephone automatically goes back into operation as soon as LAN crashes/malfunctions are repaired. The IPadapter is ready for operation as soon as it is plugged back in or relocated on the LAN; no additional administration/configuration is required. The login procedure with password entry and authentication is performed by an en- cryption algorithm to guarantee LAN security. The local power supply unit required for operation is identical to the 3 power supply units supplied for the optiset E telephones (FRG/IM; UK and US).
Fault signaling:
Depending on the type of fault, an error message describing the fault that occurred appears when an incorrect entry is made in the web page (see the following example).
Error example:
An incorrect phone number ("123abc") was entered.
The submitted data contained an error:
Phone number:
123456 CorNet TC login password:
phone-side Operation mode:
Return to Administrator settings Home
The following error message may appear on every web page in which parameters can be changed. The administrator is informed if no parameters can be modified.
CorNet TC parameters · (optional) · Submit Reset

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
The following error message appears when the administrator attempts to restart or download an application when the telephone is not idle. This is designed to prevent ongoing calls from being interrupted.
This error message may appear on every web page when local administration of the IPadapter is implemented via an optiset E terminal.
Information on setting options can be found in the Windows help or the HTML file on the web browser. To perform administration via the web browser, open the Administration menu.
To log on, proceed as follows:

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
optiPoint IPadapter Home Page
The optiPoint IPadapter web server allows the administrator to: y configure the administrator settings y perform diagnostic tests y download new software y save and restore the terminal configuration
Leads to Administration page
(via Administrator Login if necessary)
The password is “123456”. For data protection reasons, the password should be changed after it has been entered.
optiPoint IPadapter administrator login
****** Password:
Leads to requested page if
Leads to home page

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
y General Information y Administrator settings y Load (download from file server) application y Load (download from file server) configuration y Save (upload to file server) configuration y Save (upload to file server) history information y View history information y Restart terminal y Diagnostics y Change administrator password
Versions:
File transfer status:
11:23, 5 Oct 1999
9:05, 1 Oct 1999
Return to Administration Home

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
This page shows the MAC address, the versions of the various software components and the status of the last data transfer action between the data server and the optiPoint IPadapter.
y IP address and routing y CorNet TC parameters y Speech parameters y File transfer y FTP username & password
Return to Administration Home
Administrator settings

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
IP address and subnet mask of OIP-2, the IP address of the IP partner --> HG1500 V1.0 (Xpress@LAN) or optiPoint IPadapter in "peer-to-peer" mode)
IP address and routing
DHCP 10.144.233.62 IP address:
255.0.0.0 Subnet mask:
0.0.0.0 IP partner address:
IP Routing:
0.0.0.0 Default gateway:
0.0.0.0 Route 1:
0.0.0.0 Route 2:
0.0.0.0 Gateway 1:
0.0.0.0 Gateway 2:
255.0.0.0 Mask 1:
255.0.0.0 Mask 2:
Return to Administrator settings Home
You also have the option of entering additional routing information. If the file server for upload- ing/downloading, the OIP-2 and the IP partner are located in different subnets and therefore cannot be addressed via a single subnet mask, this additional IP routing gateway must be en- tered.
Submit · Reset

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
If more than 24 characters are input, the following message appears:
– "The submitted data contained an error: Invalid Phone number: "
– "The submitted data contained an error: Invalid CorNet TC login password: "
Phone number:
123456 CorNet TC login password:
phone-side Operation mode:
Return to Administrator settings Home
The setting of the jitter buffer depends on the properties of the customer network (LAN) in each case. Depending on the quality of the network, a zero speech delay ("Short" setting) or a sig- nificant speech delay ("Long" setting) may occur.
CorNet TC parameters · (optional) · Submit Reset

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
Normal Jitter buffer:
Return to Administrator settings Home
Speech parameters · Submit Reset

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
19.34.56.1 Fileserver IP address:
OIP_1_0.app Application fileserver filename:
database.ini Config fileserver filename:
history.txt History fileserver filename:
c:\ Fileserver path:
No transfer Action on submit:
Options are: y No transfer y Upload configuration y Download configuration y Download application y Upload history
Configuration of FTP username & password is on a separate page.
Return to Administrator settings Home
The parameters that are needed to download configurations from the server and to upload them to a server, or to download applications from a server and to upload history files are en- tered in this mask.
Ensure that the FTP server directory which contains the download software or configuration is enabled in the server configuration for the FTP user specified in optiPoint IPadapter.
The default parameters are displayed in the following table.
File Server IP address ’0.0.0.0’
Application file server file name ’oip.app’
Config file server file name ’oip.cfg’
History file server file name ’history.txt’
Table 7-2 FTP parameters
File transfer · Submit Reset · FTP parameter Default

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
File server path empty field
Table 7-2 FTP parameters
The default setting for “Action on submit” is "No transfer" every time you open this mask.
The following error messages appear if incorrect entries are made:
Cause of fault Fault description
wrong file server IP address No connection to server
file server not availlable No connection to server
wrong file name for download No file on server
invalid file name No Access on server
Table 7-3 Error messages
FTP username & password
fred Username:
************* New password:
************* Confirm new password:
Return to Administrator settings Home
The fields displayed are empty each time you log into this page.
The following errors may occur:
FTP parameter Default · Submit Reset

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
– "The submitted data contained an error: Inconsistent confirmation password"
Load (download from fileserver) application
This operation will FTP a new application program file from a fileserver according to the details in the File transfer page. After the application is downloaded it will be validated. If valid, the new file will replace the existing program file and the terminal will auto-restart.
FTP Settings:
Return to Administration Home
During the download, the following message is shown on the terminal display:
– OIP: Download started ...
– OIP: Programming ...
– OIP: Restart ...
Download

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
Load (download from fileserver) configuration
This operation will FTP a new configuration file from a fileserver according to the details in the File transfer page. After the configuration data is downloaded it is required to subsequently restart the terminal to activate the new values.
FTP Settings:
Return to Administration Home
Save (upload to fileserver) configuration
This operation will FTP the current configuration data to a fileserver according to the details in the File transfer page.
FTP Settings:
Return to Administration Home
Download · Save

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
Save (upload to fileserver) configuration
This operation will FTP the current history information to a fileserver according to the details in the File transfer page.
FTP Settings:
Return to Administration Home
13 day(s) ago, 17:53:31 TC_LOGON 4 day(s) ago, 21:12:10 TC_LOGOFF 4 day(s) ago, 21:12:23 TC_LOGON
Return to Administration Home
Save · History file · Empty history

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
This operation will restart the terminal immediately. (You will loose your web connection to the terminal.)
Return to Administration Home
Restart terminal · Restart

IP Adapter Nur für den internen Gebrauch
Administration Via the Web Browser
The tests on this page do not require assistance from a local user.
Select which tests to invoke:
19.24.34.198 -- IP address:
This page will be reloaded with the updated test results after the tests have been invoked.
Return to Administration Home

Nur für den internen Gebrauch IP Adapter Administration Via the Web Browser
****** Current admin password:
****** New password:
****** Confirm new password:
Return to Administration Home
The following error messages appear if incorrect entries are made:
– "The submitted data contained an error: Incorrect administrator password"
– "The submitted data contained an error: Invalid new password"
– "The submitted data contained an error: Inconsistent confirmation password"
Change administrator password · Submit Reset

IP Adapter Nur für den internen Gebrauch
Administration via optiPoint 500
Telephone-based administration is only possible at optiPoint terminals with display (i.e. not with entry, basic and signature).
If, however, you want to connect a telephone without display, then administration must first be performed with a display telephone. This telephone can then be disconnected.
The administration operation is menu-driven, i.e. all available settings are listed on the termi- nal’s display. You can navigate between the various settings with the dialog keys. Once you have made all settings, select “Start phone?”. The Administration mask closes and a connec- tion between the terminal and the system is set up. Once optiset E has been started, you can only access the Administration menu again by unplugging and reconnecting the line (booting the IPadapter).
Fault signaling:
Faults that occur when operating the optiPoint IPadapter are displayed as follows:
If the terminal has a display, an appropriate error message appears on the display. If multiple faults occur at the same time, the fault with the highest priority is displayed (see the following diagram).

Nur für den internen Gebrauch IP Adapter Administration via optiPoint 500
NO DHCP response Press any key? >
Ping to Gateway failed Press any key? >
Ping to Partner failed Press any key? >
Generic socket error Press any key? >
TC Login Error Press any key? >
Error connecting partner Press any key? >
Unknown Error Press any key? >
Figure 7-5 Faults shown on optiPoint display
Once a fault occurs, press any key on the terminal to open the optiPoint IPadapter administra- tion menu. You can resolve the fault there by modifying the appropriate settings.
If a parameter is invalid or not set correctly, the following error messages are also displayed for the configuration setting:
Example:
If an invalid Partner_IP address is entered or if the partner IP address is not set, the following error code appears: ’0x1000’ (see figure below)
highest priority · lowest priority · ’CFG error Oxnnnn’

IP Adapter Nur für den internen Gebrauch
Administration via optiPoint 500
- ERROR_FLASH 0x0001 - ERROR_TFFS_DRV 0x0002 - ERROR_TFFS_DRIVE 0x0004 - ERROR_TFFS_CREATE 0x0008 - ERROR_DOS_OPT 0x0010 - ERROR_DOS_INIT 0x0020 - ERROR_FACTORY_RESET 0x0040 - ERROR_HISTORY_CREATE 0x0080 - ERROR_HISTORY_OPEN 0x0100 - ERROR_NO_INI_FILE 0x0200 - ERROR_INI_FILE_EXPAND 0x0400 - ERROR_INI_CHECK_TERM_IP 0x0800 - ERROR_INI_CHECK_PARTNER_IP 0x1000 - ERROR_INI_CHECK_GATEWAY 0x2000 - ERROR_INI_CHECK_E164 0x4000
Figure 7-6 Error codes for configuration settings

Nur für den internen Gebrauch IP Adapter Administration via optiPoint 500
To perform administration via the telephone, proceed as follows:
No valid password entered

IP Adapter Nur für den internen Gebrauch
Administration via optiPoint 500
No valid Password entered
Password:
0 9...
No valid Password entered
Exit Password Abort? >
No valid Password entered
0 9...
and so on until the line is full ... (when line is full no more entries are accepted)

Nur für den internen Gebrauch IP Adapter Administration via optiPoint 500


IP Adapter Nur für den internen Gebrauch
Administration via optiPoint 500
No change of value
No change of value

Nur für den internen Gebrauch IP Adapter Administration via optiPoint 500

No change of value OIP IP address: Abort? >
No change of value OIP IP address: Abort? >
No change of value OIP IP address: Abort? >
and so on until the line is full ... (when line is full no more entries are accepted)

IP Adapter Nur für den internen Gebrauch
Administration via optiPoint 500
No change of value
‘system-side‘ cannot be undone - Change anyway?>
No change of value

Nur für den internen Gebrauch IP Adapter Configuration Examples
>
When you restart the computer, the IPadapter is set to "phone-side" by default as on optiPoint 500.
Configuring the optiPoint IPadapter (peer to peer) for connection to HG 1500 (Xpress@LAN) with Hicom 150 Office
Configuring the IPadapter at Hicom:

IP Adapter Nur für den internen Gebrauch
Adapter IP address Phone number optiPoint side

Partner IP address (HG 1500 IP address) HG 1500 cannot be configured via the WEB interface.
Figure 7-7 WEB access to the IPadapter
Configuration Examples

Nur für den internen Gebrauch IP Adapter Configuration Examples

The IP address, default gateway, etc. are set here.
Figure 7-8 WEB page administration

IP Adapter Nur für den internen Gebrauch
Configuration of the default gateway (the def. gateway must always be entered, even if it is in the same subnet). This is usually the same as the HG 1500 IP ad-
Partner IP address (the IP address for the HG 1500 - LAN interface in this case).
Figure 7-9 IP address and routing
Configuration Examples

Nur für den internen Gebrauch IP Adapter Configuration Examples
In HG 1500, a voice client is configured for the optiPoint IPadapter in the same way as for Op- ticlient 130 (see also the HG 1500 Service Manual).
The phone number for the IPadapter must already be available in Office. The optiPoint IPadapt- er phone number must be activated as the TFA Client after configuration in HG 1500 (see fol- lowing screenshot).

Figure 7-10 Settings in Assistant Office

IP Adapter Nur für den internen Gebrauch
Configuring the optiPoint IPadapter (peer to peer) for connection to the UP0E port of Hicom 150 E and Hicom 300E

Hicom side or Optiset side
Partner IP address (this is the IPadapt- er IP address) phone-side
Figure 7-11 optiPoint IPadapter homepage
Configuration Examples · Adapter IP address · Subscriber phone number

Nur für den internen Gebrauch IP Adapter Configuration Examples
The IP address, default gateway, etc. are set here.
Figure 7-12 WEB page administration

IP Adapter Nur für den internen Gebrauch
Partner IP address (the IPadapter IP ad- dress in this case) phone-side Configuration of the default gateway (the def. gateway must always be entered, even if it is in the same subnet).

Figure 7-13 IP address and routing
Configuration Examples

Nur für den internen Gebrauch IP Adapter Configuration Examples
The same procedure is adopted for the configuration of optiPoint IPadapter on the optiPoint 500 (phone-side) except that in each case, the other IP address is entered as the IP address and IP partner address.
When you restart the computer, the IPadapter is set to "phone-side" by default as on optiset E. The IPadapter connected to the UP0 port should only be switched to "system-side" mode using the WEB interface after configuration has been completed. The IPadapt- er resets itself after switching to "system-side" mode.
The IPadapter which is set to "system-side" mode can then only be administrated via the Web browser and not via an optiPoint system telephone.

IP Adapter Nur für den internen Gebrauch
Configuration Examples

Troubleshooting Test Loops 3 and 4
The telephone tests for optiPoint 500 are described in Section 3.6.
Troubleshooting for optiPoint 500 can be carried out on site by replacing the faulty equipment or with the appropriate spare parts.
Hicom/HiPath provide diagnostic modes that are supported by the telephone (test loops 3 and 4).
optiPoint 500 Test Loops
optiPoint 500 telephones support ISDN test loops 3 and 4 to the line card
8.2 Reboot
The first time the telephone is turned on or is reset by the local firmware, this reboot is repre- sented visually as follows:
These procedures show that the telephone was rebooted and has completed its self-test pro- cedures.
They do not indicate that communication has been established with the Hicom/HiPath.
After communication has been established with Hicom/HiPath, the Hicom/HiPath controls the screen and LEDs (excluding entry), thus showing the user that the telephone is ready for op- eration.
Test loop 3 · smartlink CPU · Test loop 4

Troubleshooting Nur für den internen Gebrauch
Reboot

Ordering Information Products and Spare Parts
9.1.1 Initial Equipment: Telephone Models, Optiset E Key Modules, and Adapters
Name Color Part Number
optiPoint 500 entry arctic S30817-S7101-A101-*
optiPoint 500 economy arctic S30817-S7108-A101-*
optiPoint 500 basic arctic S30817-S7102-A101-*
optiPoint 500 standard arctic S30817-S7103-A101-*
optiPoint 500 advance arctic S30817-S7104-A101-*
optiPoint key module arctic S30817-S7105-A101-*
optiPoint signature module arctic S30817-S7106-A101-*
optiPoint BLF arctic S30817-S7107-A101-*
optiPoint 500 entry manganese S30817-S7101-A107-*
optiPoint 500 economy manganese S30817-S7108-A107-*
optiPoint 500 basic manganese S30817-S7102-A107-*
optiPoint 500 standard manganese S30817-S7103-A107-*
optiPoint 500 advance manganese S30817-S7104-A107-*
optiPoint key module manganese S30817-S7105-A107-*
optiPoint signature module manganese S30817-S7106-A107-*
optiPoint BLF manganese S30817-S7107-A107-*
Table 9-1 opiPoint 500 models
Name Color Part Number
optiPoint phone adapter arsenic S30817-K7110-B108-*
optiPoint analog adapter arsenic S30817-K7110-B208-*
optiPoint ISDN adapter arsenic S30817-K7110-B308-*
optiPoint recorder adapter arsenic S30817-K7110-B408-*
Table 9-2 optiPoint 500 adapters

Ordering Information Nur für den internen Gebrauch
Products and Spare Parts
Name Color Part Number
optiPoint acoustic adapter arsenic S30817-K7110-B508-*
Table 9-2 optiPoint 500 adapters
Name Color Part Number
optiPoint 500 entry arctic without HS S30817-S7101-N101-*
optiPoint 500 economy without logo
optiPoint 500 basic arctic without HS S30817-S7102-N101-*
optiPoint 500 standard arctic without HS S30817-S7103-N101-*
optiPoint 500 advance arctic without HS S30817-S7104-N101-*
optiPoint 500 entry manganese without HS S30817-S7101-N107-*
optiPoint 500 economy without logo
optiPoint 500 basic manganese without HS S30817-S7102-N107-*
optiPoint 500 standard manganese without HS S30817-S7103-N107-*
optiPoint 500 advance manganese without HS S30817-S7104-N107-*
Table 9-3 optiPoint 500 without HS

Nur für den internen Gebrauch Ordering Information Products and Spare Parts
Name Color Part Number
optiPoint 500 handset arctic with logo V38140-H-X173-*
optiPoint 500 handset manganese with logo V38140-H-X174-*
optiPoint 500 handset arctic without logo V38140-H-X175-*
optiPoint 500 handset manganese without logo V38140-H-X176-*
Table 9-4 optiPoint 500 handset with/without logo
optiPoint entry (wall brackets) arsenic L36363-A328-C338-*
optiPoint basic (wall brackets) arsenic L36363-A329-C338-*
LINE CORD 6M SI 4-WIRE AS4/RJ11 F30033-X1000-X125
LINE CORD 6M SI 4-WIRE RJ11/RJ F30033-X1000-X185
LINE CORD 6M SI 4-WIRE RJ11/RJ F30033-X1000-X176
USB cable for PC S30267-Z360-A30
optiPoint Y cable L36453-Z5-C199-*
LOCAL POWER SUPPLY GBR AUL:06D1287
LOCAL POWER SUPPLY 110V USA AUL:51A4827
POWER TYPE-CONNECTING RELAY L30460-X1345-X
Table 9-5 optiPoint 500 more spare parts
BRACKET socket C39334-Z93-C12 · Handset cord L36146-H4007-L589-*

Ordering Information Nur für den internen Gebrauch
Products and Spare Parts
Cordless Headset for extended 121TR9-5 interface
Ellipse 1.8 EHS L30220-F600-H186
CA40 EHS Firefly L30220-F600-H188
Headsets 121TR9-5 for the optiPoint acoustic adapter or ad- vance headset interface (built-in)
2100 Flex Boom NC Mono L30220-F600-H184
2100 Flex Boom NC Duo L30220-F600-H185
Active loudspeaker box arctic L30460-X1278-X11
(incl. main adapter)
Active loudspeaker box manganese L30460-X1278-X12
(incl. main adapter)
Active loudspeaker box arctic L30460-X1278-X21
(incl. main adapter)
Active loudspeaker box manganese L30460-X1278-X22
(incl. main adapter)
Add-on microphone arctic L30460-X1279-X1
Add-on microphone manganese L30460-X1279-X2
Accessory pack, entry D7101-A101-1
Accessory pack basic, standard, advance D7102-A101-1
Table 9-5 optiPoint 500 more spare parts

Nur für den internen Gebrauch Ordering Information Products and Spare Parts
Accessory pack for advance D7104-A101-1
Accessory pack for BLF D7107-A101-1
Accessory pack for general optiPoint 500 A31003-H8400-B989-*- 6Z19
Table 9-5 optiPoint 500 more spare parts

Ordering Information Nur für den internen Gebrauch
Name Reference number *
Installation Instructions - key module A31003-E8000-S078-*-6Z31
Installation Instructions - signature module A31003-E8000-S096-*-6Z31
Installation Instructions - phone adapter A31003-E8000-S079-*-6Z31
Installation Instructions - acoustic adapter A31003-E8000-S092-*-6Z31
Installation Instructions - ISDN adapter A31003-E8000-S080-*-6Z31
Installation Instructions - analog adapter A31003-E8000-S091-*-6Z31
Installation Instructions - wall mounting A31003-E8000-S083-*-6Z31
Installation and Administration Instructions IPadapter
Installation Instructions - optiPoint 500 CTI TAPI Ser- vice Provider
Installation and Operating Instructions - privacy mod- ule
Operating Instructions - external speaker and desk microphone
Operating instructions for all optiPoint 500 devices and all switches on CD-ROM
Key labeling program Downloads on the Internet at: www.hipath.de Order from: http://c4bs.spls.de/index.cfm?cfto- ken=641474811&cfid=80697&Anmel- dung=1
Online key labeling tool on the Internet
* The final digits in the part number designate the following languages: -19/-20=German; -7419= German/English; -7619/-7620=English; -7719=French; -7219=Italian -6Zxx = Dutch, English, French, German, Italian, Portuguese, Spanish
Documentation · Installation instructions · Table 9-6 Documentation

Nur für den internen Gebrauch Ordering Information
Product Company Address Telephone*
Spare parts and replacement equip- ment
Siemens AG ICN Ersatzteilvertrieb Hofmannstr. 51 D-81359 Munich
Service and operating instructions
Siemens AG LZF Gründlacherstr. 258 - 260 D-90765 Fürth-Bislohe
Side-load kit TIS GmbH Barloer Weg 190 D-46397 Bocholt
optiPoint 500 handset with mute key and spe- cial designs
Bühner&Schaible Kommunikationstechnik D-73663 Bergen
I2C bus memory cards for signature modules
A&D SE Würzburgerstr. 121 90766 Fürth Mr. Rainer Eickholt [email protected] mens.de
Key labeling sheets - 40 pre-cut sheets for economy/basic/stan- dard/advance (for ev- ery 5 telephones) - 10 pre-cut sheets for entry (for every 15 tele- phones)
Siemens AG LZF Gründlacherstr. 258 - 260 D-90765 Fürth-Bislohe
Table 9-7 Order addresses
* When calling from outside Germany, replace the first 0 in the phone or fax number with +49.

Ordering Information Nur für den internen Gebrauch
After-Sales Service and Repair
optiPoint 500 and accessories for repairs and replacements can be ordered via EWS from the Spare Parts Service.
Product Company Address Telephone*
Spare parts and re- placement equipment
Siemens AG ICN Ersatzteilvertrieb Hofmannstr. 51 D-81359 Munich
* When calling from outside Germany, replace the first 0 in the phone or fax number with +49.
Order form · Fax · recipient

Nur für den internen Gebrauch Ordering Information
SIS (Service Information System)
http://sis.icn.siemens.de/sis/base.nsf
Service Guidelines http://netinfo.icn.siemens.de/icnens/produkte/ service_richtlinien/richtlinien_d.htm
http://netinfo.icn.siemens.de/icnens/tools_rules/tapim/ tapim_d.htm
ITSC (International Technical Support Center)
http://itsc.icn.siemens.de/index.htm
ES D 132 homepage (informa- tion about integrating tele- phones and protocol scripts)
http://www-ls-dev.mch.pn.siemens.de/esd132/index.htm
ICN TI (Technical Information) http://godzilla.mchh.siemens.de/gspnti/deutsch/ auswahl.htm
ICN VZ DC 2 Documentation Center
http://intranet.icn.siemens.de/vz_dc_2/index.htm
optiPoint 500 Homepage Rolm http://desktops.au.rolm.com/prdct/optiset/main.htm
Fürth Central Supply http://www.click4business-supplies.de
Firma TIS GmbH http://www.tis-gmbh.de
Firma Bühner & Schaible http://www.buehner-schaible.de
Table 9-8 Intranet addresses
Intranet Addresses · Subject Address · EWS (Engineering Worksta- tion)

Ordering Information Nur für den internen Gebrauch
Intranet Addresses

The following list contains the abbreviations used in this manual.
API Telephony Application Programming Interface
ARCOFI Audio Ringing Codec Filter (audio chip)
Audio Bus Analog transmit and receive signal
BDSG German Data Protection Act
BSG Key Module Port (RJ45, 8-pin)
CCITT Comité Consultatif International Télégraphique et Télephonique
CorNet Corporate Network Protocol
CTI Computer Telephony Integration
DC/DC DC-DC Power Supply Converter
DCE Data Circuit Terminating Equipment
DHCP Dynamic Host Configuration Protocol
DIU PCM 30 power set
DMI Digital Multiplexer Interface
DTE Data Terminal Equipment
DTMF Dual-Tone Multifrequency Signaling
EEPROM Electrically Erasable and ReProgrammable Read-Only Memory
ESD Electrostatically Sensitive Devices
GU Hookswitch (reed relay with magnet in handset)
HA Handset port (RJ 8)
ICCS Integrated Communication Cabling System
ICN TI Information and Communication Networks Technical Information
IOM2 ISDN-Oriented Modular (2B + D channel access)
P31003-E8400-A100-3-7620 Service Manual Y-1

ISDN Integrated Services Digital Network
ISO International Standard Organization
LAP-D Link Access Procedure on the D-channel
LCD Liquid Crystal Display (with standard and modular telephones only)
Lsp. Speaker for ringer, open listening and speakerphone mode
Mikr. Microphone (with optiset E standard, advance plus, and memory telephones only)
OTO Optiset Teleworking Option
PC-AC PC Attendant Console
PNT Private Network Termination
Power Power supply for options, 5 V and 21 - 56 V (from UP0/E)
RNG Call Number Generator (optiset E key module)
RS232 Data Interface (optiPoint data adapter)
SLMQ Subscriber Line Mode Q
Smartlink Line chip for UP0/E access
SNG Local Power Supply Unit
SPI bus Serial Peripheral Interface (serial data bus)
TAPI Telephony Application Programming Interface
UP0/E Trunk interface to the communication server (RJ 11)
UCON Previous name for distance adapter
P31003-E8400-A100-3-7620 Y-2 Service Manual

A Accessories 2-16 Asset ID 2-20
B Block diagram telephone layout 3-7
C Configuration 2-1 Configuration notes 2-9, 5-2 Control panel 3-1
D Data protection 1-2 Data security 1-3 Desk microphone 2-16
E Environmental conditions 2-20 ESD 1-1 External speaker 2-16
I IP administration via optiset E 7-22
K Key labeling program 2-19 Keypad 3-1
L Lists of spare parts 9-1 Local power supply unit 2-18
O Observing business and data secrecy 1-2 optiPoint 500 2-16 optipoint 500 2-16 optiPoint 500 acustic adapter 5-4 optiPoint 500 advance 2-8 optiPoint 500 analog adapter 5-4 optiPoint 500 basic 2-6
P31003-E8400-A100-3-7620 Service Manual Z-1

optiPoint 500 economy 2-5 optiPoint 500 entry 2-4 optiPoint 500 external speaker 2-16 optiPoint 500 headsets 2-17 optiPoint 500 phone adapter 5-11 optiPoint 500 phone adapter connection example 5-14 optiPoint 500 recorder adapter 5-12 optiPoint 500 standard 2-7 optiPoint IPadapter installation 7-2
P Personal data 1-2 PNT 4-1, 4-2 PNT E 4-2 PNT Q 4-2 Private network termination units 4-1 Product description 2-1 Protecting electrostatically sensitive devices 1-1
R Ranges 2-21 Reboot 8-1 Replacing boards 1-1
S Safety information 1-1 Safety symbols 1-2 Service information 1-1 Setting up the telephone 3-1 Spare parts, replacement equipment 9-1 Startup 3-1
T Technical data on the optiPoint 500 local power supply unit 2-18 Telephone Test 3-4 Time indicator 3-2 Troubleshooting 1-1
U Unpacking the box 3-1 UP0/E interface description 2-21 Using data 1-3
W Wall mounting 2-19
P31003-E8400-A100-3-7620 Z-2 Service Manual