NL
Siemens logo
Officiële handleiding

Siemens 9014

230 pagina's·2.3 MB·Printer·PDF·EN
Siemens 9014
Inhoudsopgave 265 secties Title · Preface · Brief description of the printer · 9014 Needle Printer · … TonenVerbergen
Titlep.1Prefacep.3Brief description of the printerp.39014 Needle Printerp.49015 Needle Printerp.59015 E Needle Printerp.69016 Needle Printerp.7Target groupp.8Summary of contentsp.8Notational conventionsp.9Technical data and printer optionsp.10Technical datap.12Character complementp.13Optionsp.13Connection options of the 901x-12 printersp.14Serial interface V.24 (RS-232 C)p.14Parallel Centronics interfacep.14Description of the IBM Proprinter emulationp.15Initial conditionp.16Forms transport mechanismp.17Additional commandsp.17Forms layoutp.22Set form length in linesp.22Set form length in inchesp.23Set perforation skip modep.23Reset perforation skip modep.24Set first print linep.24Set left marginp.24Set left and right marginsp.25Forms transportp.26Set 8 lpip.26Set 7/72 inch line spacing modep.26Preset n/72 inch line spacing modep.27Set preset line spacingp.27Set n/216 or n/180 inch line spacing modep.27Set line spacing unitp.28Line feed (LF)p.28Reverse line feedp.29Form feed (FF)p.29Relative vertical tabulation forwardp.29Set vertical tab stopsp.30Vertical tabulationp.30Additional commandsp.31Print carriage movementsp.32Carriage returnp.32Print head to left marginp.33Spacep.33Backspacep.33Set 10 cpip.33Set 12 cpip.34Set 17.1 cpip.34Set/reset proportional spacing modep.34Relative horizontal tabulationp.35Set horizontal tab stopsp.36Horizontal tabulationp.37Set print direction (bidirectional or unidirectional)p.37Additional commandsp.38Font designp.39Select IBM character set 1p.39Select IBM character set 2p.40Set boldface modep.40Reset boldface modep.40Set double strike modep.40Reset double strike modep.40Set subscript/superscript modep.41Reset subscript/superscript modep.41Set expanded mode for one linep.42Set/reset expanded modep.42Reset expanded modep.42Set character size and line spacingp.43Set print quality and character pitchp.44Set/reset underscore modep.44Set/reset overscore modep.45Additional commandsp.46Bitmap graphicsp.52Select graphics modep.52Select single dot-density graphics modep.55Select double dot-density graphics modep.55Select double dot-density and double-speed graphics modep.56Select quadruple dot-density graphics modep.57Select graphics mode (expanded)p.58Miscellaneous commandsp.61Set default tab stopsp.61Transparent print data for one characterp.61Transparent print data for several charactersp.62Automatic line feedp.62Set printer onlinep.63Set printer offlinep.63Clear line bufferp.63Delete characterp.63NUL functionp.64Additional commandsp.64Alternative graphics mode AGMp.65Set n/60 inch line spacing modep.65Set n/216 or n/180 inch line spacing modep.65Relative vertical tabulation forwardp.66Select graphics modep.67Description of the Epson LQ-2550 emulationp.70Initial conditionp.71Reset to initial conditionp.72Forms transport mechanismp.73Select single form feedp.73Additional commandsp.74Forms layoutp.79Set form length in linesp.79Set form length in inchesp.80Set perforation skip modep.80Reset perforation skip modep.81Set left marginp.81Set right marginp.81Forms transportp.82Set 8 lpip.82Set 6 lpip.82Set n/60 inch line spacing modep.83Set n/180 inch line spacing modep.83Set n/360 inch line spacing modep.84Line feed (LF)p.84Form feed (FF)p.84Relative vertical tabulation forwardp.85Relative vertical tabulation reversep.85Select vertical tabulation channelp.85Set vertical tab stopsp.86Set vertical tab stops in channelp.87Vertical tabulationp.88Print carriage movementsp.89Carriage returnp.89Spacep.90Backspacep.90Set 10 cpi (Pica)p.90Set 12 cpi (Elite)p.90Set 15 cpip.91Set/reset proportional spacing modep.91Set character spacing modep.92Absolute horizontal tabulationp.92Relative horizontal tabulationp.93Set horizontal tab stopsp.94Horizontal tabulationp.94Set print direction (bidirectional or unidirectional)p.95Set unidirectional print mode for one linep.95Select text alignmentp.96Font designp.97Select fontp.98Select national versionp.99Select character setp.100Set/reset user-defined character setp.100Copy current character set into user-defined character setp.101Define user-defined charactersp.102Select print qualityp.105Select character stylep.105Set italics modep.106Reset italics modep.106Set boldface modep.106Reset boldface modep.106Set double strike modep.106Reset double strike modep.106Set subscript/superscript modep.107Reset subscript/superscript modep.107Set condensed modep.108Reset condensed modep.108Set expanded mode for one linep.108Set/reset expanded modep.109Reset expanded modep.109Set/reset double height modep.109Select print mode combinationsp.110Set/reset underscore modep.110Set/reset line marking modep.111Additional commandsp.112Bitmap graphicsp.117Select graphics modep.117Reassign graphics modep.120Miscellaneous commandsp.121Control characters between X’80 and X’9Fp.121Printing characters between X’80 and X’9Fp.121Reset most significant bit (MSB) to zerop.122Set most significant bit (MSB) to onep.122Delete most significant bit (MSB) defaultp.122Set printer onlinep.123Set printer offlinep.123Clear line bufferp.123Delete characterp.123Audible signalp.124NUL functionp.124Additional commandsp.124ESC / P2 Commandsp.126Set page formatp.126Set page length in defined unitsp.127Set absolute vertical print positionp.127Set relative vertical print positionp.128Select font by pitch and pointp.128Set unitp.129Set horizontal motion index (HMI)p.129Assign character tablep.130Select character tablep.130Print data as charactersp.131Select graphics modep.131Print raster graphicsp.132Barcodesp.133General informationp.134Code 39p.1342 out of 5 Industrialp.1352 out of 5 Interleavedp.136Codabarp.137EAN-8 and EAN-13p.137EAN-8 and EAN-13 Add-onp.139Code 93p.139MSI Mod 10/10p.142UPC-A and UPC-Ep.143UPC-A and UPC-E Add-onp.144Code 128 (EAN 128)p.144POSTNETp.145Select barcodep.146Set/reset barcode modep.150Programming examplesp.150Format of the 13-digit standard EAN numberp.165Command overview of the IBM Proprinter emulationp.166Forms transport mechanismsp.166Forms layoutp.167Forms transportp.168Print carriage movementsp.170Font designp.172Bitmap graphicsp.175Miscellaneous commandsp.176Alternative graphics mode AGMp.178Command overview of the Epson LQ-2550 emulationp.179Initial conditionp.179Forms transport mechanismp.179Forms layoutp.180Forms transportp.181Print carriage movementsp.183Font designp.185Bitmap graphicsp.189Miscellaneous commandsp.189ESC / P2 commandsp.191Character set tablesp.192IBM all character setp.192IBM set 1p.193National versions of IBM set 1p.194IBM set 2p.195National versions of IBM set 2p.196IBM code pagesp.197Page 437p.197Page 850p.198Page 858p.199Page 860p.200Page 863p.201Page 865p.202Epson EXT GCTp.203National versions of Epson EXT GCTp.204Epson ITALICp.205National versions of Epson ITALIC (1)p.206National versions of Epson ITALIC (2)p.207OCR-Ap.208ISO 8859-1p.209Code tablesp.210ISO 7-bit code (international version)p.210ISO 7-bit code (German national version)p.211Meaning of the control characters in the code tablesp.212Hexadecimal -> decimal conversion and vice versap.213Interfacesp.214Serial V.24/RS-232 C interfacep.214Parallel Centronics interfacep.218Use with two interfacesp.221Related publicationsp.222Environmental protectionp.224Indexp.225
Page 1 of the Siemens 9014 user manual — Epson and IBM Proprinter Emulation
Pagina 1 · klik om te vergroten
Pagina 1

9014, 9015, 9015 E, 9016 Printer

Epson and IBM Proprinter Emulation

Programmer Reference Guide

EditionSeptember 1999
Page 2 of the Siemens 9014 user manual — Title
Pagina 2 · klik om te vergroten
Pagina 2

Copyright © Siemens AG 1999.

All rights reserved. Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Copyright and Trademarks

Page 3 of the Siemens 9014 user manual — Brief description of the printer
Pagina 3 · klik om te vergroten
Pagina 3

Preface

This manual describes the IBM® Proprinter® emulation as well as the Epson® LQ-2550 and ESC/P2 emulation.

Brief description of the printer

The 9014, 9015,9015 E and 9016 printers are extremely fast 24 needle printers that emphasize convenient handling of paper and high performance.

The modern printer concept enables them to be used with Siemens data systems as workstation printers and for large print volumes.

The effective printing rate depends on various parameterizable functions such as, for example, form feed, sheet insertion and ejection, print modes etc.

Most printer functions can also be selected at the printer control panel. Function selection is menu-controlled.

Page 4 of the Siemens 9014 user manual — 9014 Needle Printer
Pagina 4 · klik om te vergroten
Pagina 4

9014 Needle Printer

Siemens 9014 — 9014 Needle Printer diagram (page 4)
Afb. 1 · 9014 Needle Printer

The 9014 printer is equipped with continuous forms tractor and manual single sheet insertion.

For automatic sheet feeding, the printer can be equipped with up to three ASF (Automatic Sheet Feeder) cassettes.

Different types of paper handling are available with the 9014 printer:

– single sheet (manual)

– continuous forms (tractor)

– single sheet (automatic)

Preface · – envelope (automatic)

Page 5 of the Siemens 9014 user manual — 9015 Needle Printer
Pagina 5 · klik om te vergroten
Pagina 5

9015 Needle Printer

Siemens 9014 — 9015 Needle Printer diagram (page 5)
Afb. 2 · 9015 Needle Printer

Convenient handling of paper is available with the 9015 printer:

Using tractor cassettes, two continuous forms stacks can be inserted in a comfor- table way.

A parking position for continuous forms handling is available.

There is no loss of sheets when you tear off continous forms (Zero-Tear-Off-Funk- tion).

The printer offers a cut-off feature.

Preface

Page 6 of the Siemens 9014 user manual — 9015 E Needle Printer
Pagina 6 · klik om te vergroten
Pagina 6

9015 E Needle Printer

Siemens 9014 — 9015 E Needle Printer diagram (page 6)
Afb. 3 · 9015 E Needle Printer

The 9015 E needle printer offers the same attributes as the 9015 printer except from the cut-off feature. Additionally, the 9015 E printer can optionally be equipped with a manual single sheet insertion.

Preface

Page 7 of the Siemens 9014 user manual — 9016 Needle Printer
Pagina 7 · klik om te vergroten
Pagina 7

9016 Needle Printer

Siemens 9014 — 9016 Needle Printer diagram (page 7)
Afb. 4 · 9016 Needle Printer

The fast high performance 9016 needle printer offers the handling of continouos forms (tractor) and, optionally, of single sheets (manual insertion).

Preface

Page 8 of the Siemens 9014 user manual — Summary of contents
Pagina 8 · klik om te vergroten
Pagina 8

Target group

The contents of this manual is intended for users who want to program printer output.

Familiarity with printer programming is required.

Summary of contents

This manual describes the control characters of the following Epson and IBM Proprinter emulations of the 9014 / 9015 / 9015 E and 9016 printer:

Dieses Handbuch beschreibt die Steuerzeichen der folgenden Epson- und IBM-Proprinter- Emulationen der Drucker 9014 / 9015 / 9015 E / 9016:

G Epson LQ-2550 / 1060 and ESC/P2

G IBM Proprinter emulations (IBM printers 4207, 4208 (XL24) )

The ECMA emulation is described in further Programmer’s Reference Guides (see [1], [4]).

References in the text consist of numbers enclosed in square brackets.

The full titles of the referenced publications and manuals are given in the References chapter.

Target group Preface

Page 9 of the Siemens 9014 user manual — !
Pagina 9 · klik om te vergroten
Pagina 9

Notational conventions

In this manual, the following conventions have been used:

Italics Names of files, programs, commands, variables, options and screen texts such as input fields, text fields, menus etc. in plain text

Monospace System output such as error messages, other messages, notes, excerpts from files

Monospace bold User input in examples

“Quotation marks” References to other chapters or manuals

Keys or key combinations in plain text

Additional information, notes and tips

!

® User activities

Page 10 of the Siemens 9014 user manual — Technical data and printer options
Pagina 10 · klik om te vergroten
Pagina 10

Technical data and printer options

9014 printer interface modules

The 9014 printer with IBM Proprinter and Epson LQ-2550 emulation is equipped with the 90142-12 interface module. It contains a parallel (Centronics®-compatible) and a serial V.24 (RS-232 C) interface. The 9014 printer with the 90142-12 interface module is referred to below as the 9014-12 printer. There are two other interface modules with IBM / Epson emulation:

– 90142-13 with additional IGP functionality

– 90142-14 with additional East European character sets

For network connections, the following interface module is available:

– 90142-LE2 (Ethernet® LAN connection for Epson LQ-2550 and IBM Proprinter emula- tion)

The printer is also available with the ECMA emulation with one of the following interface modules:

– 90142-11 with SS97 (RS-422 A) and V.24 (RS-232 C)

– 90142-15 with SS97 (RS-422 A), V.24 (RS-232 C) and BAM controller

– 90142-LE1 (Ethernet® LAN connection for ECMA emulation)

The functions of the ECMA emulation are described in a separate Programmer’s Reference Guide [4].

9015 / 9015 E printer interface modules

The 9015 printer with IBM Proprinter and Epson LQ-2550 emulation is equipped with the 90152-12 interface module. It contains a parallel (Centronics®-compatible) and a serial V.24 (RS-232 C) interface. The 9015 printer with the 90152-12 interface module is referred to below as the 9015-12 printer. There is another interface module with IBM/Epson emulation:

– 90152-13 with additional IGP functionality

Page 11 of the Siemens 9014 user manual — Technical data and printer options
Pagina 11 · klik om te vergroten
Pagina 11

Technical data and printer options

For network connections, the following interface module is available:

– 90152-LE2 (Ethernet® LAN connection for Epson LQ-2550 and IBM Proprinter emula- tion)

The printer is also available with the ECMA emulation with one of the following interface modules:

– 90152-11 with SS97 (RS-422 A) and V.24 (RS-232 C)

– 90152-15 with SS97 (RS-422 A), V.24 (RS-232 C) and BAM controller

– 90152-LE1 (Ethernet® LAN connection for ECMA emulation)

The functions of the ECMA emulation are described in a separate Programmer’s Reference Guide [1].

9016 printer interface modules

With the 9016 printer, the serial RS-232 C / RS 422 and the Centronics® interface for the IBM Proprinter and Epson LQ-2550 emulation are integrated. Since this equipment of the 9016 printer is equivalent to the 9014-12 and 90152-12 printer types, the printer is referred to below as the 9016-12.

Page 12 of the Siemens 9014 user manual — Technical data
Pagina 12 · klik om te vergroten
Pagina 12

Technical data Technical data and printer options

Technical data

The following table lists the major technical data of the printer that is relevant to programmers.

Printing systemPrint head with 24 needles Print directionBidirectional with logic seeking Print matrix24 x 36 - letter quality (LQ) 12 x 36 - near letter quality (NLQ) 12 x 12 - draft (DRAFT) Printing rate (characters per second)175 - letter quality (LQ) 350 - near letter quality (NLQ) 700 - draft (DRAFT) Printer buffer16 Kbyte up to 48 Kbyte (programmable) Column width (mm or inch)Normal font 2.54 or 1/ 10 2.12 or 1/ 12 1.76 or 1/ 14,4 1.69 or 1/ 15 1.49 or 1/ 17 1.41 or 1/ 18 1.27 or 1/ 20 Micro-column width (inch)1/ for DRAFT 120 1/ for LQ/NLQ 180 Micro-line spacing (inch)1/ 360 Character height (mm)2.42 to 3.3 and thereof double, threefold, fourfold, up to eightfold height; DATA LARGE up to 999-fold height Character widthsingle width: depends on the font and the selected character pitch; thereof double, threefold, fourfold up to eightfold width; DATA LARGE up to 999-fold width
Page 13 of the Siemens 9014 user manual — Options
Pagina 13 · klik om te vergroten
Pagina 13

Character complement Technical data and printer options

Character complement

The standard character complement of the printers contains up to fifteen fonts with several character sets. Some character sets can be used with different national versions.

Further information on fonts and character sets is given in the description of corresponding commands and in the tables (for the character sets see Character set tables).

Options

The following options are currently available:

– Automatic sheet feeder (ASF)

– Console with integrated paper rack

G 9015 E printer

– Console with integrated paper rack

– Manual single sheet insertion

Show 7 more labels / short text on this page
G 9014 printer · – Console · G 9015 printer · – Tractor cassette · – Tractor cassette · G Drucker 9016 · – console
Page 14 of the Siemens 9014 user manual — Parallel Centronics interface
Pagina 14 · klik om te vergroten
Pagina 14

Connection options of the 901x-12 printers

The 901x-12 printers can be connected via the serial and parallel interface.

Serial interface V.24 (RS-232 C)

The 901x-12 printers can be connected with the following systems via the V.24 interface (RS-232 C):

– Quattro / BNC / 886x systems

Parallel Centronics interface

The 901x-12 printer can be connected with the following systems via the Centronics interface:

Show 5 more labels / short text on this page
– RM systems · – Primergy systems · – PC’s · – Primergy systems · – PC’s
Page 15 of the Siemens 9014 user manual — Description of the IBM Proprinter emulation
Pagina 15 · klik om te vergroten
Pagina 15

Description of the IBM Proprinter emulation

With the IBM Proprinter emulation, the 9014, 9015, 9015 E and 9016 printers behave like the 4207 and 4208 (XL24) printers from IBM.

The commands are divided into the following command groups:

G Forms transport mechanism

G Print carriage movements

Show 6 more labels / short text on this page
G Initial condition · G Forms layout · G Forms transport · G Font design · G Bitmap graphics · G Miscellaneous commands
Page 16 of the Siemens 9014 user manual — Initial condition
Pagina 16 · klik om te vergroten
Pagina 16

Initial condition IBM Proprinter emulation

Initial condition

After power-on, the printer is in the following condition:

– Printer buffer cleared

– All vertical tab stops reset

– Proportional spacing mode reset

– Horizontal tab stops set in every eighth column

– Print direction bidirectional

– Boldface mode off

– Double strike mode off

– Subscript/superscript mode off

– Expanded mode off

– Normal character height

– Underscore mode off

– Overscore mode off

– Character enlargement mode off

The following functions depend on the menu setting:

– Perforation skip mode

– Font (type style)

– Print quality (DRAFT, LQ, NLQ)

– National version/IBM code page

Show 7 more labels / short text on this page
– Form length · – Left margin · – Right margin · – Line spacing · – Character set · – Character pitch · – Paper source
Page 17 of the Siemens 9014 user manual — Additional commands
Pagina 17 · klik om te vergroten
Pagina 17

Forms transport mechanism IBM Proprinter emulation

Forms transport mechanism

The printer is always equipped with two continous forms tractors. The last sheet of a conti- nuous forms stack can be printed to the end of the form.

Additional commands

ESC [ < s 1B 5B 3C 73 27 91 60 115

This command causes a vertical form feed to the beginning of the next page.

Select paper source and ejection, number of copies, cut-off mode

ESC [ > p1 ; p2 ; p3 ; p4 s 1B 5B 3E p1 3B p2 3B p3 3B p4 73

27 91 62 p1 59 p2 59 p3 59 p4 115

The control character > should only be used if an indent or a form feed (FF) is to be performed.

p4= 0 to 1 is only available for the 9015 printer with cut-off feature.

Eject sheet · (SPS or SPSIF)

Page 18 of the Siemens 9014 user manual — Forms transport mechanism
Pagina 18 · klik om te vergroten
Pagina 18

Forms transport mechanism IBM Proprinter emulation

p1= 0

Manual single form feed

p1=1 bis 3

ASF, bin 1 to 3

p1= 6

p1= 7

p1= 8

ASF, bin 1 or 2

p1= 9

ASF, bin 2 or 3

p1= 10

ASF, bin 1 or 2 or 3

p2= 0

AGC (automatic gap control)

p2= 1 bis 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

Cut-off sheets in upper tray

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Batch output (rear side)

G 9014 Printer · Ignored · Tractor

Page 19 of the Siemens 9014 user manual — Forms transport mechanism
Pagina 19 · klik om te vergroten
Pagina 19

Forms transport mechanism IBM Proprinter emulation

p1= 0 to 3

p1= 6

p1= 7

p1= 8 to 10

p1= 15

Selection of both tractors (upper and lower)

p2= 0

AGC (automatic gap control)

p2= 1 to 6

PCC (programmable copy control) (Print gap for 1- to 6-ply copies)

p3= 0

Cut-off sheets in upper tray

p3= 1

p3= 2

p3= 3

Sheets in stack (default)

p4= 0

Cut-off feature off (default)

p4= 1

Show 8 more labels / short text on this page
G 9015 Printer · Ignored · Upper tractor · Lower tractor · Ignored · Ignored · Ignored · Cut-off feature on
Page 20 of the Siemens 9014 user manual — Forms transport mechanism
Pagina 20 · klik om te vergroten
Pagina 20

Forms transport mechanism IBM Proprinter emulation

G 9015 E Printer

p1= 0

Manual single form feed

p1=1 to 3

p1= 6

p1= 7

p1= 8 to 10

p1= 15

Selection of both tractors (upper and lower)

p2= 0

AGC (automatic gap control)

p2= 1 bis 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Batch output (rear side)

Show 5 more labels / short text on this page
Ignored · Upper tractor · Lower tractor · Ignored · Ignored
Page 21 of the Siemens 9014 user manual — Forms transport mechanism
Pagina 21 · klik om te vergroten
Pagina 21

Forms transport mechanism IBM Proprinter emulation

p1= 0

Manual single form feed

p1=1 to 3

p1= 6

p1= 7

p1= 8 to 10

p1= 15

p2= 0

AGC (automatic gap control)

p2= 1 bis 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Show 7 more labels / short text on this page
G 9016 Printer · Ignored · Ignored · Lower tractor · Ignored · Ignored · Ignored
Page 22 of the Siemens 9014 user manual — Set form length in lines
Pagina 22 · klik om te vergroten
Pagina 22

Forms layout IBM Proprinter emulation

Forms layout

The dimensions of the form can be selected freely. The following commands are available:

G Set form length in lines

G Set form length in inches

G Set perforation skip mode

G Reset perforation skip mode

G Set first print line

G Set left margin

G Set left and right margins

Set form length in lines

ESC C p1 1B 43 p1 27 67 p1

This command specifies the physical page length in multiples of the current line spacing and sets the current vertical position as the first print line (top of form).

The set page length is not affected by later changes of the line spacing.

p1 Form length in multiples of the current line spacing

Range: X’01 ≤ p1 ≤ X’7F The minimum valid form length is 3 inches and the maximum is 22 inches.

Page 23 of the Siemens 9014 user manual — Set perforation skip mode
Pagina 23 · klik om te vergroten
Pagina 23

Forms layout IBM Proprinter emulation

Set form length in inches

ESC C NUL p1 1B 43 00 p1 27 67 00 p1

This command specifies the physical page length in inches and sets the current vertical position as the first print line (top of form).

p1 Form length in inches

Range: X’01 ≤ p1 ≤ X’16 The minimum valid form length is 3 inches and the maximum is 22 inches.

Set perforation skip mode

ESC N p1 1B 4E p1 27 78 p1

The perforation area is specified as a number of lines at the current line spacing. It is skipped at the end of every page.

The perforation area is not affected by later changes of the line spacing.

The perforation area should be selected so that at least 4/6 inch remain as print area.

If you change the first line (top of form), the perforation area moves accordingly.

p1 Perforation area in lines at the current line spacing

RangeX’00 ≤ p 1 ≤ X’FF
Page 24 of the Siemens 9014 user manual — Set left margin
Pagina 24 · klik om te vergroten
Pagina 24

Forms layout IBM Proprinter emulation

Reset perforation skip mode

ESC O 1B 4F 27 79

Set first print line

ESC 4 1B 34 27 52

The current print line is defined as the first print line (top form). The first print line should be selected so that at least 4/6 inch remain as print area.

The set form length is not affected by this command.

Set left margin

ESC ; 1B 3B 27 59

The current print column defines the first printable character in the line and thus the left margin.

The set left margin is not affected by later changes of the character pitch.

The left margin should be selected so that at least 4/10 inch remain as print area between the left and right margins.

This function should not be used in new applications.

Page 25 of the Siemens 9014 user manual — Set left and right margins
Pagina 25 · klik om te vergroten
Pagina 25

Forms layout IBM Proprinter emulation

Set left and right margins

ESC X p1 p2 1B 58 p1 p2 27 88 p1 p2

The parameters define the first and last print columns of a line at the current character pitch and thus define the left and right margins.

The first print column of a line is column 1. The set margins are not affected by later changes of the character pitch. The margin setting should be selected so that at least 4/10 inch remain as print area between the left and right margins.

This command must be located at the beginning of the line.

If you specify 0 (zero) for a parameter, the current margin setting is not affected.

p1 Left margin in columns at the current character pitch

RangeX’00 ≤ p 1 ≤ X’FC

p2 Right margin in columns at the current character pitch

RangeX’04 ≤ p 2 ≤ X’FF
Page 26 of the Siemens 9014 user manual — Set 7/72 inch line spacing mode
Pagina 26 · klik om te vergroten
Pagina 26

Forms transport IBM Proprinter emulation

Forms transport

The following commands affect the paper movement:

G Set 8 lpi

G Set 7/72 inch line spacing mode

G Preset n/72 inch line spacing mode

G Set preset line spacing

G Set n/216 or n/180 inch line spacing mode

G Set line spacing unit

G Line feed (LF)

G Reverse line feed

G Form feed (FF)

G Relative vertical tabulation forward

G Set vertical tab stops

Set 8 lpi

ESC 0 1B 30 27 48

The line spacing is set to 8 lines per inch.

Set 7/72 inch line spacing mode

ESC 1 1B 31 27 49

A line spacing of 7/72 inch is set.

G Vertical tabulation · G Additional commands

Page 27 of the Siemens 9014 user manual — Set n/216 or n/180 inch line spacing mode
Pagina 27 · klik om te vergroten
Pagina 27

Forms transport IBM Proprinter emulation

Preset n/72 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1

A line spacing of n/72 is preset. The defined line spacing is set by the ESC 2 command.

p1 Line spacing in 1/72 inch increments

RangeX’01 ≤ p 1 ≤ X’55

Set preset line spacing

ESC 2 1B 32 27 50

The line spacing preset with the ESC A p1 command is set.

Set n/216 or n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1

A line spacing of n/216 or n/180 inch is set depending on the line spacing unit (see Set line spacing unit).

The default is n/216 inch.

p1 Line spacing in n/216 or n/180 inch increments

RangeX’01 ≤ p 1 ≤ X’FF
Page 28 of the Siemens 9014 user manual — LF 0A 10
Pagina 28 · klik om te vergroten
Pagina 28

Forms transport IBM Proprinter emulation

Set line spacing unit

ESC [ \ EOT NUL NUL NUL p1 NUL

1B 5B 5C 04 00 00 00 p1 00

27 91 92 04 00 00 00 p1 00

This command sets the line spacing unit to either 1/216 inch or 1/180 inch.

The preset line spacing unit only affects the two commands ESC 3 p1 and ESC J p1.

p1 Line spacing unit

Valid parameter values:

180 216 B4 D8

Line spacing 1/180 inch Line spacing 1/216 inch

Line feed (LF)

Control character Hexadecimal Decimal

LF 0A 10

A line feed is performed using the current line spacing. The contents of the line buffer are printed.

This control character terminates the expanded mode for one line.

A carriage return is also performed depending on the menu setting.

Dec Hex Meaning

Page 29 of the Siemens 9014 user manual — Relative vertical tabulation forward
Pagina 29 · klik om te vergroten
Pagina 29

Forms transport IBM Proprinter emulation

Reverse line feed

ESC ] 1B 5D 27 93

ESC M 1B 4D 27 77

The reverse line feed is performed using the current line spacing. The contents of the line buffer are printed.

Form feed (FF)

FF 0C 12

The paper is advanced to the next top of form position. The contents of the line buffer are printed and a carriage return is performed.

This control character terminates the expanded mode for one line.

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1

The vertical print position is moved down by n/216 or n/180 inch depending on the line spacing unit (see Set line spacing unit).

The default is n/216 inch.

p1 Relative vertical movement in n/216 inch or n/180 inch increments

RangeX’00 ≤ p 1 ≤ X’FF
Page 30 of the Siemens 9014 user manual — VT 0B 11
Pagina 30 · klik om te vergroten
Pagina 30

Forms transport IBM Proprinter emulation

Set vertical tab stops

ESC B p1 ... pk NUL 1B 42 p1 ... pk 00 27 66 p1 ... pk 00

A maximum of 64 vertical tab stops can be set. Previously set vertical tab stops are reset.

The vertical tab stops must be defined in ascending order in lines. The absolute vertical tab location depends on the current line spacing.

The line count begins with one at the first print line (see Set first print line).

The set vertical tab stops are not affected by later changes of the line spacing.

All vertical tab stops are reset if no parameters are specified (ESC B NUL).

p1 ... pk Vertical tab stops in lines (1 ≤ k ≤ 64)

RangeX’01 ≤ p k ≤ X’FF

Vertical tabulation

Control character Hexadecimal Decimal

VT 0B 11

This control character causes vertical tabulation to the next vertical tab stop. Vertical tabulation is possible anywhere within a line.

Repeated specification of this control character causes vertical tab stops to be skipped. If you transfer VT VT VT, for example, the printer positions the print head to the third vertical tab stop. If no tab stops are set, this control character causes a line feed.

This control character terminates the expanded mode for one line.

A carriage return is also performed depending on the menu setting.

Page 31 of the Siemens 9014 user manual — Additional commands
Pagina 31 · klik om te vergroten
Pagina 31

Forms transport IBM Proprinter emulation

Additional commands

ESC [ p1{ 1B 5B p1 7B 27 91 p1 123

This command loads and sets the line spacing. Valid values: 1, 2, 3, 4, 6, 8, 12, 16, 24, 48, 60, 72, 90, 144, 180, 360 lpi.

ESC [ p1g 1B 5B p1 67 27 91 p1 103

Valid values:

p1 = 0

Reset tab stop at the current position

p1 = 3

Reset all horizontal tab stops

p1 = 4

Reset all vertical tab stops

Load line spacing · Reset tab stop

Page 32 of the Siemens 9014 user manual — CR 0D 13
Pagina 32 · klik om te vergroten
Pagina 32

Print carriage movements IBM Proprinter emulation

Print carriage movements

The following commands control the print carriage movements:

G Print head to left margin

G Set 10 cpi

G Set 12 cpi

G Set 17.1 cpi

G Set/reset proportional spacing mode

G Relative horizontal tabulation

G Set horizontal tab stops

G Set print direction (bidirectional or unidirectional)

Carriage return

Control character Hexadecimal Decimal

CR 0D 13

The print carriage moves to the beginning of the line. The character following CR is printed as the first character in the line.

A line feed may be performed in addition to the carriage return depending on the menu setting. When writing new application programs, be sure to terminate each line with LF and CR.

Show 5 more labels / short text on this page
G Carriage return · G Space · G Backspace · G Horizontal tabulation · G Additional commands
Page 33 of the Siemens 9014 user manual — DC2 12 18
Pagina 33 · klik om te vergroten
Pagina 33

Print carriage movements IBM Proprinter emulation

Print head to left margin

ESC < 1B 3C 27 60

The print carriage moves to the beginning of the line.

Space

Control character Hexadecimal Decimal

SP 20 32

The print head moves one space width using the set or programmed character pitch.

If an expanded mode is active, the space width is increased accordingly.

Backspace

Control character Hexadecimal Decimal

BS 08 08

Reverse movement by the width of one space.

Set 10 cpi

Control character Hexadecimal Decimal

DC2 12 18

Set a character pitch of 10 cpi.

Page 34 of the Siemens 9014 user manual — Set/reset proportional spacing mode
Pagina 34 · klik om te vergroten
Pagina 34

Print carriage movements IBM Proprinter emulation

Set 12 cpi

ESC : 1B 3A 27 58

Set a character pitch of 12 cpi.

Set 17.1 cpi

SI 0F 15

Set a character pitch of 17.1 cpi.

Set/reset proportional spacing mode

ESC P p1 1B 50 p1 27 80 p1

In proportional spacing mode the character width differs. An i, for example, is narrower than an m.

Proportional spacing is possible with all fonts except the OCR fonts.

p1 sets/resets proportional spacing

Valid parameter values:

0 1 48 49

0 1 30 31

Reset proportional spacing mode Set proportional spacing mode Reset proportional spacing mode Set proportional spacing mode

Dec Hex Meaning

Page 35 of the Siemens 9014 user manual — Relative horizontal tabulation
Pagina 35 · klik om te vergroten
Pagina 35

Print carriage movements IBM Proprinter emulation

Relative horizontal tabulation

ESC d p1 p2 1B 64 p1 p2 27 100 p1 p2

The horizontal print position is moved right by the defined amount. The specified shift begins at the current print position and has to be specified in 1/120 inch increments.

Spaces are shown underscored, overscored or crossed out if the function is active.

The defined right margin cannot be exceeded.

p1 p2 define the shift

Shift= (p1 + (p2 * 256)) * 1/120 inch

RangeX’00 ≤ p 1 ≤ X’FF
RangeX’00 ≤ p 2 ≤ X’FF
Page 36 of the Siemens 9014 user manual — Set horizontal tab stops
Pagina 36 · klik om te vergroten
Pagina 36

Print carriage movements IBM Proprinter emulation

Set horizontal tab stops

ESC D p1 ... pk NUL 1B 44 p1 ... pk 00 27 68 p1 ... pk 00

This command sets horizontal tab stops. A maximum of 32 horizontal tab stops can be set. Previously set horizontal tab stops are reset.

The horizontal tab stops must be specified in ascending order in multiples of the current character pitch. The absolute horizontal tab stop locations depend on the current character pitch.

The set horizontal tab stops are not affected by later changes of the character pitch.

The default horizontal tab stop locations are in every eighth print column.

All horizontal tab stops are reset if no parameter is specified (ESC D NUL).

p1 ... pk Horizontal tab stops in multiples of the character pitch (1 ≤ k ≤ 32)

RangeX’01 ≤ p k ≤ X’FF
Page 37 of the Siemens 9014 user manual — Set print direction (bidirectional or unidirectional)
Pagina 37 · klik om te vergroten
Pagina 37

Print carriage movements IBM Proprinter emulation

Horizontal tabulation

Control character Hexadecimal Decimal

HT 09 09

This control character may be located anywhere within a line and causes tabulation to the next horizontal tab stop. Repeated specification of this control character causes horizontal tab stops to be skipped. If you transfer HT, for example, the printer positions the print head to the fourth horizontal tab stop.

Conditions for horizontal tabulation:

G At least one horizontal tab stop must be set.

G The printer ignores the control character if no horizontal tab stops are set or if tabulation exceeds the end of the line.

G If the print head is on a set horizontal tab stop, the next horizontal tab stop is accessed.

Set print direction (bidirectional or unidirectional)

ESC U p1 1B 55 p1 27 85 p1

Unidirectional printing should be used if high positioning precision is required (e.g. in the graphics mode). The default is bidirectional printing.

p1 defines the print direction

Valid parameter values:

0 1 48 49

0 1 30 31

Bidirectional print direction Unidirectional print direction Bidirectional print direction Unidirectional print direction

The command is ignored if the menu setting does not permit unidirectional printing (see [2]).

Dec Hex Meaning

Page 38 of the Siemens 9014 user manual — Additional commands
Pagina 38 · klik om te vergroten
Pagina 38

Print carriage movements IBM Proprinter emulation

Additional commands

ESC [ p1 ‘ 1B 5B p1 60 27 91 p1 96

p1 defines the print position and consists of a maximum of three digits. p1 = 0 and p1 = 1 define the first print position and thus have the same meaning.

ESC [ p1 a 1B 5B p1 61 27 91 p1 97

p1 defines the print position and consists of a maximum of three digits. p1 = 0 and p1 = 1 define the first print position and thus have the same meaning.

ESC [ p1 d 1B 5B p1 64 27 91 p1 100

p1 defines the print line and consists of a maximum of three digits. p1 = 0 and p1 = 1 define the first print line and thus have the same meaning.

ESC [ p1 e 1B 5B p1 65 27 91 p1 101

p1 defines the number of print lines and consists of a maximum of three digits. p1 = 0 and p1 = 1 define the first print line and thus have the same meaning.

Show 4 more labels / short text on this page
Absolute horizontal positioning · Relative horizontal positioning · Absolute vertical positioning · Relative vertical positioning
Page 39 of the Siemens 9014 user manual — Select IBM character set 1
Pagina 39 · klik om te vergroten
Pagina 39

Font design IBM Proprinter emulation

Font design

The following commands are available for font design:

G Select IBM character set 1

G Select IBM character set 2

G Set boldface mode

G Reset boldface mode

G Set double strike mode

G Reset double strike mode

G Set subscript/superscript mode

G Reset subscript/superscript mode

G Set expanded mode for one line

G Set/reset expanded mode

G Reset expanded mode

G Set character size and line spacing

G Set print quality and character pitch

G Set/reset underscore mode

G Set/reset overscore mode

Select IBM character set 1

ESC 7 1B 37 27 55

In the initial condition the printer uses the character set specified in the menu.

G Additional commands

Page 40 of the Siemens 9014 user manual — Set boldface mode
Pagina 40 · klik om te vergroten
Pagina 40

Font design IBM Proprinter emulation

Select IBM character set 2

ESC 6 1B 36 27 54

In the initial condition the printer uses the character set specified in the menu.

Set boldface mode

ESC E 1B 45 27 69

Reset boldface mode

ESC F 1B 46 27 70

Set double strike mode

ESC G 1B 47 27 71

Reset double strike mode

ESC H 1B 48 27 72

Page 41 of the Siemens 9014 user manual — Reset subscript/superscript mode
Pagina 41 · klik om te vergroten
Pagina 41

Font design IBM Proprinter emulation

Set subscript/superscript mode

ESC S p1 1B 53 p1 27 83 p1

This command causes reduced-size characters to be superscripted (exponents) or subscripted (indices).

Superscripted characters (exponents) are printed approx. 1/2 line up. Subscripted characters (indices) are only reduced in size and printed on the base line.

p1 defines subscript or superscript mode

Parameter values:

0 1 48 49

00 01 30 31

Set superscript mode Set subscript mode Set superscript mode Set subscript mode

The menu setting must be INDEX/EXPONENT (see [2]).

Reset subscript/superscript mode

ESC T 1B 54 27 84

Dec Hex Meaning

Page 42 of the Siemens 9014 user manual — Reset expanded mode
Pagina 42 · klik om te vergroten
Pagina 42

Font design IBM Proprinter emulation

Set expanded mode for one line

SO 0E 14

The characters in one line are printed with double width.

The function is terminated by LF, CR, VT, FF, DC4 and ESC W 0.

Set/reset expanded mode

ESC W p1 1B 57 p1 27 87 p1

Characters are printed with double width when the expanded mode is active.

p1 sets/resets the expanded mode

Parameter values:

0 1 48 49

00 01 30 31

Reset expanded mode Set expanded mode Reset expanded mode Set expanded mode

Reset expanded mode

DC4 14 20

This function only resets expanded mode set with the SO command.

Dec Hex Meaning

Page 43 of the Siemens 9014 user manual — Set character size and line spacing
Pagina 43 · klik om te vergroten
Pagina 43

Font design IBM Proprinter emulation

Set character size and line spacing

ESC [ @ EOT NUL NUL NUL p1 p2

1B 5B 40 04 00 00 00 p1 p2

27 91 64 04 00 00 00 p1 p2

This command defines the line spacing, the character height, and the character width.

p1 The left half-byte defines the line spacing and the right half-byte the character height. The left and right half-bytes must be added.

Valid parameter values for the left half-byte:

00 16 32 48 64

00 10 20 30 40

No change of line spacing Single character height line spacing Double character height line spacing Triple character height line spacing Quadruple character height line spacing

Valid parameter values for the right half-byte:

00 01 02 03 04

00 01 02 03 04

No change of character height Single character height Double character height Triple character height Quadruple character height

p2 defines the character width

Valid parameter values:

00 01 02 03 04

00 01 02 03 04

No change of character width Single character width Double character width Triple character width Quadruple character width

Dec Hex Meaning · Dec Hex Meaning · Dec Hex Meaning

Page 44 of the Siemens 9014 user manual — Set/reset underscore mode
Pagina 44 · klik om te vergroten
Pagina 44

Font design IBM Proprinter emulation

Set print quality and character pitch

ESC I p1 1B 49 p1 27 73 p1

This command defines the print quality and the character pitch.

p1 defines the print quality and the character pitch

Valid parameter values:

0 1 2 3 8 10 16 18

00 01 02 03 08 0A 10 12

DRAFT quality; DRAFT quality LQ/NLQ quality; LQ/NLQ quality; DRAFT quality; LQ/NLQ quality; DRAFT quality; LQ/NLQ quality;

10 cpi proportional spacing 10 cpi proportional spacing 12 cpi 12 cpi 17.1 cpi 17.1 cpi

Set/reset underscore mode

ESC - p1 1B 2D p1 27 45 p1

The characters are underscored.

p1 sets/resets the underscore mode

Valid parameter values:

0 1 48 49

00 01 30 31

Reset underscore mode Set underscore mode Reset underscore mode Set underscore mode

Dec Hex Meaning · Dec Hex Meaning

Page 45 of the Siemens 9014 user manual — Set/reset overscore mode
Pagina 45 · klik om te vergroten
Pagina 45

Font design IBM Proprinter emulation

Set/reset overscore mode

ESC _ p1 1B 5F p1 27 95 p1

The characters are overscored.

p1 sets/resets the overscore mode

Valid parameter values:

0 1 48 49

00 01 30 31

Reset overscore mode Set overscore mode Reset overscore mode Set overscore mode

Dec Hex Meaning

Page 46 of the Siemens 9014 user manual — Additional commands
Pagina 46 · klik om te vergroten
Pagina 46

Font design IBM Proprinter emulation

Additional commands

ESC [ p1 m 1B 5 B p1 6D 27 91 p1 109

Valid values:

p1 = 0 Normal presentation (all settings reset)

p1 = 1

p1 = 3

p1 = 4

p1 = 9

p1 = 20

p1 = 21

p1 = 22

p1 = 23

p1 = 24

p1 = 29

p1 = 30 to 36

p1 = 53

p1 = 55

Show 14 more labels / short text on this page
Set graphic settings · Bold · Italics · Underscored · Crossed out · Double character width · double underline · Reset bold mode · Reset italics mode · Reset underscored mode · Reset crossed-out mode · Ignored · Overscored · Reset overscored mode
Page 47 of the Siemens 9014 user manual — Additional commands
Pagina 47 · klik om te vergroten
Pagina 47

Font design IBM Proprinter emulation

ESC [ p1 b 1B 5B p1 62 27 91 p1 98

p1 can be a maximum of three digits.

Graphical change of sizes

ESC [ p1; p2 SP B 1B 5B p1 3B p2 20 42 27 91 p1 59 p2 32 66

Valid values:

p1 = 100 / p2 = 100

Normal height / normal width

p1 = 200 / p2 = 200

Double height / Double width

p1 = 300 / p2 = 300

Triple height / Triple width

p1 = 400 / p2 = 400

Quadruple height / Quadruple width

p1 and p2 max. = 800 (in steps of 100)

Graphical change of size for DATA LARGE:

p1 = 100 / p2 = 100

Normal height / normal width

p1 and p2 max. = 9900 (in steps of 100)

Character repetition

Page 48 of the Siemens 9014 user manual — Additional commands
Pagina 48 · klik om te vergroten
Pagina 48

Font design IBM Proprinter emulation

Set national version and code page

ESC [ p1; p2 w 1B 5B p1 3B p2 77 27 91 p1 59 p2 119

p1 = 1 to 15

For national versions or code pages

p1 für IBM SET 2:

p 1 = 1U.S.A
p 1 = 2France
p 1 = 3Germany

p1 = 4 : U.K.

p 1 = 5Denmark 1
p 1 = 6Sweden
p 1 = 7Italy
p 1 = 8Spain 1
p 1 = 9Japan
p 1 = 10Norway
p 1 = 11Denmark 2
p 1 = 12Spain 2
p 1 = 13Latin AM
p 1 = 14Turkey

p1 for IBM CODE PAGE:

p 1 = 1PAGE 437
p 1 = 2PAGE 850
p 1 = 3PAGE 860
p 1 = 4PAGE 863
p 1 = 5PAGE 865
p 1 = 6PAGE 858 (Euro-character)
Page 49 of the Siemens 9014 user manual — Additional commands
Pagina 49 · klik om te vergroten
Pagina 49

Font design IBM Proprinter emulation

p2 = d3 d2 d1 (three digits)

0 6 1 IBM set 1

0 6 2 IBM set 2

0 6 3 IBM code page

0 7 1 Epson EXT GCT

ESC [ p1 w 1B 5B p1 77 27 91 p1 119

See the command “Set/reset overscore mode” for the setting of p1.

ESC [ ; p2 w 1B 5B 3B p2 77 27 91 59 p2 119

See the command “Set/reset overscore mode” for the setting of p2.

Set character pitch and select font

ESC [ p1 ; p2 x 1B 5B p1 3B p2 78 27 91 p1 59 p2 120

p1 = 1

p1 = 2

p1 = 3

p1 = 4

p1 = 5

Show 7 more labels / short text on this page
Set national version · Set code page · Data · Roman · Sans Serif · Courier · Prestige
Page 50 of the Siemens 9014 user manual — OCR-A
Pagina 50 · klik om te vergroten
Pagina 50

Font design IBM Proprinter emulation

p1 = 6

p1 = 7

OCR-B

p1 = 8

OCR-A

p1 = 9

p1 = 10

p1 = 11

p1 = 12

p2 = 1

p2 = 2

p2 = 3

p2 = 4

p2 = 5

p2 = 6

14.4 cpi

p2 = 7

p2 = 8

17.1 cpi

p2 = 9

Show 12 more labels / short text on this page
Script · Orator-C · Orator · Data Block · Data Large · 10 cpi · 12 cpi · 15 cpi · Proportional · Proportional · 18 cpi · 20 cpi
Page 51 of the Siemens 9014 user manual — NLQ
Pagina 51 · klik om te vergroten
Pagina 51

Font design IBM Proprinter emulation

ESC [ p1 x 1B 5B p1 78 27 91 p1 120

See the command “Set character pitch and select font” for the setting of p1.

Set print quality (NLQ, LQ)

ESC [ p1 SP X 1B 5B p1 20 58 27 91 p1 32 88

p1 = 0

LQ

p1 = 1

NLQ

This is only valid if the NLQ type style is available.

Select font

Page 52 of the Siemens 9014 user manual — Select graphics mode
Pagina 52 · klik om te vergroten
Pagina 52

Bitmap graphics IBM Proprinter emulation

Bitmap graphics

The following commands are available:

G Select graphics mode

G Select single dot-density graphics mode

G Select double dot-density graphics mode

G Select double dot-density and double-speed graphics mode

G Select quadruple dot-density graphics mode

G Select graphics mode (expanded)

Select graphics mode

ESC * p1 p2 p3 data 1B 2A p1 p2 p3 data 27 42 p1 p2 p3 data

The graphics data is transferred in columns. A column contains either 8 or 24 individual vertical dots.

Each graphics line begins with this command, which defines the graphics mode (vertical and horizontal resolution). A defined number of pixel data items follows. The number of columns is defined by parameters p2 and p3.

Siemens 9014 — Select graphics mode diagram (page 52)
Afb. 5 · Select graphics mode
Figure 1Vertical dot density 72 dpi
Page 53 of the Siemens 9014 user manual — Bitmap graphics
Pagina 53 · klik om te vergroten
Pagina 53

Bitmap graphics IBM Proprinter emulation

Siemens 9014 — Bitmap graphics diagram (page 53)
Afb. 6 · Bitmap graphics
Figure 2Vertical dot density 180 dpi
Page 54 of the Siemens 9014 user manual — ESC Z
Pagina 54 · klik om te vergroten
Pagina 54

Bitmap graphics IBM Proprinter emulation

p1 defines the graphics mode

Valid parameter values:

Dec Hex Mode Number of needles

dpi Compatible commands hori- zontal

Single density Double density Double density and high speed1)

ESC K ESC L ESC Y

3 4 5 6 11

03 04 05 06 0B

8

240 80 72 90 144

72

ESC Z

CRT 1 Plotter CRT 2 Double density Plotter 1)

32 33 38 39 40

20 21 26 27 28

Single density Double density CRT 3 Triple density Sixfold density 1)

24

60 120 90 180 360

180

1. In this mode, printing in adjacent columns is not possible.

p2 p3 define the number of columns

Number of columns = p2 + (p3 * 256)

Data Data bytes containing the dot information

Show 5 more labels / short text on this page
verti- cal · 00 01 02 · 60 120 120 · 72 72 72 · Quadruple density 1)
Page 55 of the Siemens 9014 user manual — Select double dot-density graphics mode
Pagina 55 · klik om te vergroten
Pagina 55

Bitmap graphics IBM Proprinter emulation

Select single dot-density graphics mode

ESC K p1 p2 data 1B 4B p1 p2 data 27 75 p1 p2 data

The graphics data is transferred in columns. A column contains 8 individual vertical dots (see Select graphics mode).

This command causes a graphics line to be printed.

The horizontal resolution is 60 dpi and the vertical resolution is 72 dpi.

p1 p2 define the number of columns

Number of columns = p1 + (p2 * 256)

Data Data bytes containing the dot information

Select double dot-density graphics mode

ESC L p1 p2 data 1B 4C p1 p2 data 27 76 p1 p2 data

The graphics data is transferred in columns. A column contains 8 individual vertical dots (see Select graphics mode).

This command causes a graphics line to be printed.

The horizontal resolution is 120 dpi and the vertical resolution is 72 dpi.

p1 p2 define the number of columns

Number of columns = p1 + (p2 * 256)

Data Data bytes containing the dot information

Page 56 of the Siemens 9014 user manual — Select double dot-density and double-speed graphics mode
Pagina 56 · klik om te vergroten
Pagina 56

Bitmap graphics IBM Proprinter emulation

Select double dot-density and double-speed graphics mode

ESC Y p1 p2 data 1B 59 p1 p2 data 27 89 p1 p2 data

The graphics data is transferred in columns. A column contains 8 individual vertical dots (see Select graphics mode).

This command causes a graphics line to be printed with double speed.

The horizontal resolution is 120 dpi and the vertical resolution is 72 dpi.

p1 p2 define the number of columns

Number of columns = p1 + (p2 * 256)

Data Data bytes containing the dot information

In this mode, printing in adjacent columns is not possible.

Page 57 of the Siemens 9014 user manual — Select quadruple dot-density graphics mode
Pagina 57 · klik om te vergroten
Pagina 57

Bitmap graphics IBM Proprinter emulation

Select quadruple dot-density graphics mode

ESC Z p1 p2 data 1B 5A p1 p2 data 27 90 p1 p2 data

The graphics data is transferred in columns. A column contains 8 individual vertical dots (see Select graphics mode).

This command causes a graphics line to be printed.

The horizontal resolution is 240 dpi and the vertical resolution is 72 dpi.

p1 p2 define the number of columns

Number of columns = p1 + (p2 * 256)

Data Data bytes containing the dot information

In this mode, printing in adjacent columns is not possible.

Page 58 of the Siemens 9014 user manual — Select graphics mode (expanded)
Pagina 58 · klik om te vergroten
Pagina 58

Bitmap graphics IBM Proprinter emulation

Select graphics mode (expanded)

ESC [ g p1 p2 p3 data 1B 5B 67 p1 p2 p3 data 27 91 103 p1 p2 p3 data

The graphics data is transferred in columns. A column contains either 8 or 24 individual vertical dots.

Each graphics line begins with this command. p1 and p2 define the amount of graphics data. The definition of the graphics mode with p3 (vertical and horizontal resolution) follows.

Siemens 9014 — Select graphics mode (expanded) diagram (page 58)
Afb. 7 · Select graphics mode (expanded)
Figure 3Vertical dot density 72 dpi
Page 59 of the Siemens 9014 user manual — Select graphics mode (expanded)
Pagina 59 · klik om te vergroten
Pagina 59

Bitmap graphics IBM Proprinter emulation

Siemens 9014 — Select graphics mode (expanded) diagram (page 59)
Afb. 8 · Select graphics mode (expanded)
Figure 4Vertical dot density 180 dpi
Page 60 of the Siemens 9014 user manual — ESC Z
Pagina 60 · klik om te vergroten
Pagina 60

Bitmap graphics IBM Proprinter emulation

p1 p2 define the number of graphics data bytes + 1

Number of graphics data bytes = p1 + (p2 * 256) * number of bytes/column

p3 defines the graphics mode

Valid parameter values:

Dec Hex Mode Number of needles

dpi Compatible commands hori- zontal

Single density Double density Double density and high speed 1)

ESC K ESC L ESC Y

3 08 09 11 12

03 08 09 0B 0C

8 24

240 60 120 180 360

72 180

ESC Z

Single density Double density Triple density Sixfold density 1)

1. In this mode, printing in adjacent columns is not possible.

Data Data bytes containing the dot information

Show 5 more labels / short text on this page
verti- cal · 00 01 02 · 60 120 120 · 72 72 72 · Quadruple density 1)
Page 61 of the Siemens 9014 user manual — Transparent print data for one character
Pagina 61 · klik om te vergroten
Pagina 61

Miscellaneous commands IBM Proprinter emulation

Miscellaneous commands

G Set default tab stops

G Transparent print data for one character

G Transparent print data for several characters

G Automatic line feed

G Set printer online

G Set printer offline

G Clear line buffer

Set default tab stops

ESC R 1B 52 27 82

This command causes a horizontal tab stop to be set in every eighth column.

All set vertical tab stops are reset.

Transparent print data for one character

ESC ^ p1 1B 5E p1 27 94 p1

The character in the specified code location is printed. Characters defined as non-printing characters can also be printed (e.g. characters between X’00 and X’20).

Every transparent print data byte is interpreted as an individual character code. If no character is defined for a character code, a space is printed.

G Delete character · G NUL function · G Additional commands

Page 62 of the Siemens 9014 user manual — Automatic line feed
Pagina 62 · klik om te vergroten
Pagina 62

Miscellaneous commands IBM Proprinter emulation

Transparent print data for several characters

ESC \ p1 p2 1B 5C p1 p2 27 92 p1 p2

This command enables printing the characters in all code locations. Characters defined as non-printing characters can also be printed (e.g. characters between X’00 and X’20).

Every transparent print data byte is interpreted as an individual character code. If no character is defined for a character code, a space is printed.

p1 p2 define the number of transparent print data bytes

Number = (p1 + (p2 * 256))

Automatic line feed

ESC 5 p1 1B 35 p1 27 53 p1

This command sets/resets the automatic line feed function.

p1 Automatic line feed

Valid parameter values:

0 1 48 49

00 01 30 31

Reset Set Reset Set

(CR = CR) (CR = CR + LF) (CR = CR) (CR = CR + LF)

Dec Hex Meaning

Page 63 of the Siemens 9014 user manual — DEL 7F 127
Pagina 63 · klik om te vergroten
Pagina 63

Miscellaneous commands IBM Proprinter emulation

Set printer online

Control character Hexadecimal Decimal

DC1 11 17

Sets an offline printer online.

The command is ineffective if the printer was set offline with the ONLINE button.

Set printer offline

ESC Q # 1B 51 23 27 81 35

ESC Q $ 1B 51 24 27 81 36

Sets the printer offline. All following data is ignored except for the Set printer online command.

Clear line buffer

Control character Hexadecimal Decimal

CAN 18 24

Clears the whole contents of the line buffer.

Delete character

Control character Hexadecimal Decimal

DEL 7F 127

Deletes the character received last.

Page 64 of the Siemens 9014 user manual — $$/ 24 24 2F 36 36 47
Pagina 64 · klik om te vergroten
Pagina 64

Miscellaneous commands IBM Proprinter emulation

NUL function

Control character Hexadecimal Decimal

NUL 00 00

This control character has no effect.

Additional commands

$$ 24 24 36 36

This command replaces the control sequence ESC [, hexadecimal 1B 5B, decimal 27 91.

$$/ 24 24 2F 36 36 47

This command replaces the control sequence ESC, hexadecimal 1B, decimal 27.

ESC [ p1 ; p2 SP r 1B 5B p1 3B p2 20 72 27 91 p1 59 p2 32 114

p1 can have the values 1 to 4.

p2 selects the emulation.

p2 = 2

p2 = 3

p2 = 4

Show 6 more labels / short text on this page
Command replacement $$ · Command replacement $$/ · Macro selection · IBM Proprinter · IBM Proprinter, AGM · Epson LQ-2550
Page 65 of the Siemens 9014 user manual — Set n/216 or n/180 inch line spacing mode
Pagina 65 · klik om te vergroten
Pagina 65

Alternative graphics mode AGM IBM Proprinter emulation

Alternative graphics mode AGM

The alternative graphics mode can be selected in the menu (see [2]).

In the alternative graphics mode, the functions of the commands described below change:

G Set n/60 inch line spacing mode

G Set n/216 or n/180 inch line spacing mode

G Relative vertical tabulation forward

G Select graphics mode

Set n/60 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1

A line spacing of n/60 is set. The defined line spacing is activated directly in the AGM mode.

p1 sets the n/60 inch line spacing mode

RangeX’01 ≤ p 1 ≤ X’55

Set n/216 or n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1

A line spacing of n/216 or n/180 inch is set depending on the line spacing unit (see table “Set line spacing unit”).

The AGM mode default is n/180 inch.

p1 Line spacing in n/216 or n/180 inch increments

RangeX’01 ≤ p 1 ≤ X’FF
Page 66 of the Siemens 9014 user manual — Relative vertical tabulation forward
Pagina 66 · klik om te vergroten
Pagina 66

Alternative graphics mode AGM IBM Proprinter emulation

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1

The vertical print position is moved down n/216 or n/180 inch depending on the line spacing unit (see Set line spacing unit).

The AGM mode default is n/180 inch.

p1 Relative vertical shift in n/216 or n/180 inch increments

RangeX’00 ≤ p 1 ≤ X’FF
Page 67 of the Siemens 9014 user manual — Select graphics mode
Pagina 67 · klik om te vergroten
Pagina 67

Alternative graphics mode AGM IBM Proprinter emulation

Select graphics mode

ESC * p1 p2 p3 data 1B 2A p1 p2 p3 data 27 42 p1 p2 p3 data

The graphics data is transferred in columns. A column contains either 8 or 24 individual vertical dots.

Each graphics line begins with the command that defines the graphics mode (vertical and horizontal resolution). A defined number of pixel items follows. The number of columns is defined by parameters p2 and p3.

Siemens 9014 — Select graphics mode diagram (page 67)
Afb. 9 · Select graphics mode
Figure 5Vertical dot density 60 dpi
Page 68 of the Siemens 9014 user manual — Select graphics mode
Pagina 68 · klik om te vergroten
Pagina 68

Alternative graphics mode AGM IBM Proprinter emulation

Siemens 9014 — Select graphics mode diagram (page 68)
Afb. 10 · Select graphics mode
Figure 6Vertical dot density 180 dpi
Page 69 of the Siemens 9014 user manual — ESC Z
Pagina 69 · klik om te vergroten
Pagina 69

Alternative graphics mode AGM IBM Proprinter emulation

p1 defines the graphics mode

Valid parameter values:

Dec Hex Meaning Number of needles

dpi Compatible commands hori- zontal

Single density Double density Double density and high speed 1)

ESC K ESC L ESC Y

3 4 6 32 33 38 39 40

03 04 06 20 21 26 27 28

8 8 8 24

240 80 90 60 120 90 180 360

60 60 60 180

ESC Z

CRT 1 CRT 2 Single density Double density CRT 3 Triple density Sixfold density 1)

1. In this mode, printing in adjacent columns is not possible.

p2 p3 define the number of columns

Number of columns = p2 + (p3 * 256)

Data Data bytes containing the dot information

Show 5 more labels / short text on this page
verti- cal · 00 01 02 · 60 120 120 · 60 60 60 · Quadruple density 1)
Page 70 of the Siemens 9014 user manual — Description of the Epson LQ-2550 emulation
Pagina 70 · klik om te vergroten
Pagina 70

Description of the Epson LQ-2550 emulation

With the Epson LQ-2550 emulation, the 9014, 9015, 9015 E and 9016 printers behave like the Epson LQ-2550.

The commands are divided into the following command groups:

G Forms transport mechanism

G Print carriage movements

G ESC / P2 commands

Show 6 more labels / short text on this page
G Initial condition · G Forms layout · G Forms transport · G Font design · G Bitmap graphics · G Miscellaneous commands
Page 71 of the Siemens 9014 user manual — Initial condition
Pagina 71 · klik om te vergroten
Pagina 71

Initial condition Epson LQ-2550 emulation

Initial condition

After power-on, the printer is in the following initial condition:

– Printer buffer cleared

– Tab stops in all vertical tabulation channels reset

– Vertical tabulation channel 0 selected

– Proportional spacing mode reset

– Character spacing zero

– Horizontal tab stops set in every eighth column

– Print direction bidirectional

– User-defined character set inactive and cleared

– Normal character style

– Italics mode off

– Boldface mode off

– Double strike mode off

– Subscript/superscript mode off

– Condensed mode off

– Expanded mode off

– Normal character height

– Underscore mode off

– Line marking mode off

– Character enlargement mode off

– Reassign graphics mode off

– Delete MSB default

– Text left-justified

Page 72 of the Siemens 9014 user manual — Reset to initial condition
Pagina 72 · klik om te vergroten
Pagina 72

Initial condition Epson LQ-2550 emulation

The following functions depend on the menu setting:

– Perforation skip mode

– Font (type style)

– Print quality (DRAFT, LQ, NLQ)

Reset to initial condition

ESC @ 1B 40 27 64

This command sets the printer to the initial condition.

The user-defined character set is not reset by this command.

Show 8 more labels / short text on this page
– Form length · – Left margin · – Right margin · – Line spacing · – Character set · – National version · – Character pitch · – Paper source
Page 73 of the Siemens 9014 user manual — EM=19
Pagina 73 · klik om te vergroten
Pagina 73

Forms transport mechanism Epson LQ-2550 emulation

Forms transport mechanism

The printer is always equipped with two continuous forms tractors. The last sheet of a conti- nuous forms stack can be printed on up to the end of the form.

The capability of the printer to feed paper from different sources is optimally supplemented by the option that automatically adjusts the distance between the print head and the print platen.

Select single form feed

ESC EM p1 1B 19 p1 27 25 p1

This control character is only available for the 9014 and 9016 printers, because the other printers don’t have the equipment for single form feed.

G 9014 printer:

EM=19

p1= 1

ASF, bin 1 or 2

p1= 2

ASF, bin 2 or 3

p1= 3

ASF, bin 1 or 2 or 3

p1 = 82 or R(52)

EM=19

p1 = 82 or R(52)
Show 5 more labels / short text on this page
Form feed · eject sheet · G 9016 printer · Form feed · eject sheet
Page 74 of the Siemens 9014 user manual — Additional commands
Pagina 74 · klik om te vergroten
Pagina 74

Forms transport mechanism Epson LQ-2550 emulation

Additional commands

ESC [ < s 1B 5B 3C 73 27 91 60 115

This command causes a vertical form feed to the beginning of the next page.

Select paper source and ejection, number of copies, cut-off mode

ESC [ > p1 ; p2 ; p3 ; p4 s 1B 5B 3E p1 3B p2 3B p3 3B p4 73 27 91 62 p1 59 p2 59 p3 59 p4 115

The control character > should only be used if an indent or a form feed (FF) is to be performed.

p4= 0 to 1 is only available for the 9015 printer with cut-off feature.

p1= 0

Manual single form feed

p1=1 to 3

ASF, bin 1 to 3

p1= 6

p1= 7

p1= 8

ASF, bin 1 or 2

p1= 9

ASF, bin 2 or 3

Show 5 more labels / short text on this page
Eject sheet · (SPS or SPSIF) · G 9014 printer · Ignored · Tractor
Page 75 of the Siemens 9014 user manual — Additional commands
Pagina 75 · klik om te vergroten
Pagina 75

Forms transport mechanism Epson LQ-2550 emulation

p1= 10

ASF, bin 1 or 2 or 3

p2= 0

AGC = automatic gap control

p2= 1 to 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

Cut-off sheets in upper tray

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Batch output (rear side)

Page 76 of the Siemens 9014 user manual — Additional commands
Pagina 76 · klik om te vergroten
Pagina 76

Forms transport mechanism Epson LQ-2550 emulation

p1= 0 to 3

p1= 6

p1= 7

p1= 8 to 10

p1= 15

Selection of both tractors (upper and lower)

p2= 0

AGC (automatic gap control)

p2= 1 to 6

PCC (programmable copy control)

p3= 0

Cut-off sheets in upper tray

p3= 1

p3= 2

p3= 3

Sheets in stack (default)

p4= 0

Cut-off feature off (default)

p4= 1

Show 8 more labels / short text on this page
G 9015 printer · Ignored · Upper tractor · Lower tractor · Ignored · Ignored · Ignored · Cut-off feature on
Page 77 of the Siemens 9014 user manual — Additional commands
Pagina 77 · klik om te vergroten
Pagina 77

Forms transport mechanism Epson LQ-2550 emulation

G 9015 E printer

p1= 0

Manual single form feed

p1=1 to 3

p1= 6

p1= 7

p1= 8 to 10

p1= 15

Selection of both tractors (upper and lower)

p2= 0

AGC = automatic gap control

p2= 1 to 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Batch output (rear side)

Show 5 more labels / short text on this page
Ignored · Upper tractor · Lower tractor · Ignored · Ignored
Page 78 of the Siemens 9014 user manual — Additional commands
Pagina 78 · klik om te vergroten
Pagina 78

Forms transport mechanism Epson LQ-2550 emulation

p1= 0

Manual single form feed

p1= 1 bis 3

p1= 6

p1= 7

p1= 8 bis 10

p1= 15

p2= 0

AGC = automatic gap control

p2= 1 to 6

PCC = programmable copy control (Print gap for 1- to 6-ply copies)

p3= 0

p3= 1

Paper exit front side (confirmed by start/stop key)

p3= 2

Paper exit front side, (not confirmed by start/stop key, but controlled by application)

p3= 3

Show 8 more labels / short text on this page
G 9016 printer · Ignored · Ignored · Lower Tractor · Ignored · Ignored · Ignored · Ignored
Page 79 of the Siemens 9014 user manual — Set form length in lines
Pagina 79 · klik om te vergroten
Pagina 79

Forms layout Epson LQ-2550 emulation

Forms layout

The dimensions of a form can be selected freely. The following commands are available:

G Set form length in lines

G Set form length in inches

G Set perforation skip mode

G Reset perforation skip mode

G Set left margin

G Set right margin

Set form length in lines

ESC C p1 1B 43 p1 27 67 p1

This command specifies the physical form length in multiples of the current line spacing and sets the current vertical position as the first print line (top of form).

The set form length is not affected by later changes of the line spacing.

p1 Form length in multiples of the current line spacing

Range: X’01 ≤ p1 ≤ X’7F The minimum form length is 3 inches and the maximum form length is 22 inches.

Page 80 of the Siemens 9014 user manual — Set perforation skip mode
Pagina 80 · klik om te vergroten
Pagina 80

Forms layout Epson LQ-2550 emulation

Set form length in inches

ESC C NUL p1 1B 43 00 p1 27 67 00 p1

This command specifies the physical form length in inches and sets the current vertical position as the first print line (top of form).

p1 Form length in inches

Range: X’01 ≤ p1 ≤ X’16 The minimum form length is 3 inches and the maximum form length is 22 inches.

Set perforation skip mode

ESC N p1 1B 4E p1 27 78 p1

The perforation area is specified in number of lines at the current line spacing. The perforation area is not changed by later changes of the line spacing. It is skipped at the end of every page.

The perforation area must be selected so that at least 4/6 inch remain as print area.

The perforation skip mode is reset by changing the form length or by the Reset perforation skip mode command.

p1 Perforation area in lines at the current line spacing

RangeX’01 ≤ p 1 ≤ X’7F
Page 81 of the Siemens 9014 user manual — Set right margin
Pagina 81 · klik om te vergroten
Pagina 81

Forms layout Epson LQ-2550 emulation

Reset perforation skip mode

ESC O 1B 4F 27 79

The perforation skip mode is reset.

Set left margin

ESC l p1 1B 6C p1 27 108 p1

The left margin is set to the right edge of the specified column.

The first column of a line is column 1. The set left margin is not affected by later changes of the character pitch. The left margin must be selected so that at least 4/10 inch remain as print area between the left and right margins.

This command must be located at the beginning of the line.

p1 Left margin in columns at the current character pitch

RangeX’00 ≤ p 1 ≤ X’FC

Set right margin

ESC Q p1 1B 51 p1 27 81 p1

The right margin is set to the right edge of the specified column.

The first column of a line is column 1. The set right margin is not affected by later changes of the character pitch. The right margin must be selected so that at least 4/10 inch remain as print area between the left and right margins.

This command must be located at the beginning of the line.

p1 Right margin in columns at the current character pitch

RangeX’04 ≤ p 1 ≤ X’FF
Page 82 of the Siemens 9014 user manual — Set 6 lpi
Pagina 82 · klik om te vergroten
Pagina 82

Forms transport Epson LQ-2550 emulation

Forms transport

The following commands affect paper movements:

G Set 8 lpi

G Set 6 lpi

G Set n/60 inch line spacing mode

G Set n/180 inch line spacing mode

G Set n/360 inch line spacing mode

G Line feed (LF)

G Form feed (FF)

G Relative vertical tabulation forward

G Relative vertical tabulation reverse

G Select vertical tabulation channel

G Set vertical tab stops

G Set vertical tab stops in channel

Set 8 lpi

ESC 0 1B 30 27 48

The line spacing is set to 8 lines per inch.

Set 6 lpi

ESC 2 1B 32 27 50

The line spacing is set to 6 lines per inch.

G Vertical tabulation

Page 83 of the Siemens 9014 user manual — Set n/180 inch line spacing mode
Pagina 83 · klik om te vergroten
Pagina 83

Forms transport Epson LQ-2550 emulation

Set n/60 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1

The line spacing is set to n/60 inch.

p1 Line spacing in 1/60 inch increments

RangeX’00 ≤ p 1 ≤ X’7F

Set n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1

The line spacing is set to n/180 inch.

p1 Line spacing in 1/180 inch increments

RangeX’00 ≤ p 1 ≤ X’FF
Page 84 of the Siemens 9014 user manual — FF 0C 12
Pagina 84 · klik om te vergroten
Pagina 84

Forms transport Epson LQ-2550 emulation

Set n/360 inch line spacing mode

ESC + p1 1B 2B p1 27 43 p1

The line spacing is set to n/360 inch.

p1 Line spacing in 1/360 inch increments

RangeX’00 ≤ p 1 ≤ X’FF

Line feed (LF)

Control character Hexadecimal Decimal

LF 0A 10

The line feed is performed using the current line spacing. The contents of the line buffer are printed.

The expanded mode for one line is terminated by this control character.

A carriage return is also performed depending on the menu setting.

Form feed (FF)

Control character Hexadecimal Decimal

FF 0C 12

The paper is advanced to the next top of form position. The contents of the line buffer are printed.

The expanded mode for one line is terminated by this control character.

A carriage return is also performed depending on the menu setting.

Page 85 of the Siemens 9014 user manual — Select vertical tabulation channel
Pagina 85 · klik om te vergroten
Pagina 85

Forms transport Epson LQ-2550 emulation

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1

The vertical print position is moved down in n/180 inch increments.

p1 Relative vertical movement in n/180 inch increments

RangeX’00 ≤ p 1 ≤ X’FF

Relative vertical tabulation reverse

ESC j p1 1B 6A p1 27 106 p1

The vertical print position is moved up in n/180 inch increments.

p1 Relative vertical movement in n/180 inch increments

RangeX’00 ≤ p 1 ≤ X’FF

Select vertical tabulation channel

ESC / p1 1B 2F p1 27 47 p1

This command selects the vertical tabulation channel that contains the vertical tab stops used by the Vertical tabulation command.

p1 Number of the vertical tabulation channel

RangeX’00 ≤ p 1 ≤ X’07
Page 86 of the Siemens 9014 user manual — Set vertical tab stops
Pagina 86 · klik om te vergroten
Pagina 86

Forms transport Epson LQ-2550 emulation

Set vertical tab stops

ESC B p1 ... pk NUL 1B 42 p1 ... pk 00 27 66 p1 ... pk 00

This command sets vertical tab stops in channel 0 (see Select vertical tabulation channel and Set vertical tab stops in channel). Up to 16 vertical tab stops can be defined per channel. Vertical tab stops set previously are reset.

The vertical tab stops must be specified in ascending order in lines. The absolute vertical tab stop locations depend on the current line spacing.

The line count begins with 1 at the first print line.

The set vertical tab stops are not affected by later changes of the line spacing.

All vertical tab stops are reset if no parameter is specified (ESC B NUL).

p1 ... pk Vertical tab stops in lines (1 ≤ k ≤ 16)

RangeX’01 ≤ p k ≤ X’FF
Page 87 of the Siemens 9014 user manual — Set vertical tab stops in channel
Pagina 87 · klik om te vergroten
Pagina 87

Forms transport Epson LQ-2550 emulation

Set vertical tab stops in channel

ESC b p1 p2 ... pk NUL 1B 62 p1 p2 ... pk 00 27 98 p1 p2 ... pk 00

This command sets vertical tab stops in the specified channel (see table “Set vertical tab stops” on page 86).

Eight different vertical tabulation channels are available. Up to 16 vertical tab stops can be defined per channel. Vertical tab stops set previously in the specified channel are reset.

The vertical tab stops in the channel must be specified in ascending order in lines. The absolute vertical tab stop locations depend on the current line spacing.

The line count begins with 1 at the first print line.

The set vertical tab stops are not affected by later changes of the line spacing.

All vertical tab stops set in the specified channel are reset if parameters p2 to pk are missing (ESC b p1 NUL).

p1 Vertical tabulation channel

RangeX’00 ≤ p k ≤ X’07

p2 ... pk Vertical tab stops in lines (2 ≤ k ≤ 17)

RangeX’01 ≤ p k ≤ X’FF
Page 88 of the Siemens 9014 user manual — VT 0B 11
Pagina 88 · klik om te vergroten
Pagina 88

Forms transport Epson LQ-2550 emulation

Vertical tabulation

Control character Hexadecimal Decimal

VT 0B 11

This control character causes vertical tabulation to the next vertical tab stop in the current vertical tabulation channel. Vertical tabulation is possible anywhere within a line.

Repeating this control character causes tab stops to be skipped. VT VT VT, for example, positions the print head to the third vertical tab stop. If no tab stops are set, this control character performs a line feed.

A carriage return is also performed depending on the menu setting. The expanded mode for one line is terminated by this control character.

Page 89 of the Siemens 9014 user manual — CR 0D 13
Pagina 89 · klik om te vergroten
Pagina 89

Print carriage movements Epson LQ-2550 emulation

Print carriage movements

The following commands affect the print carriage movements:

G Set 10 cpi

G Set 12 cpi

G Set 15 cpi

G Set/reset proportional spacing mode

G Set character spacing mode

G Absolute horizontal tabulation

G Relative horizontal tabulation

G Set horizontal tab stops

G Set print direction (bidirectional or unidirectional)

G Set unidirectional print mode for one line

G Select text alignment

Carriage return

Control character Hexadecimal Decimal

CR 0D 13

The print carriage moves to the beginning of the line (left margin). The character following CR is printed as the first character of the line.

A line feed may be performed in addition to the carriage return depending on the menu setting. When writing new application programs, take care to terminate each line with LF and CR.

Show 4 more labels / short text on this page
G Carriage return · G Space · G Backspace · G Horizontal tabulation
Page 90 of the Siemens 9014 user manual — Set 12 cpi (Elite)
Pagina 90 · klik om te vergroten
Pagina 90

Print carriage movements Epson LQ-2550 emulation

Space

Control character Hexadecimal Decimal

SP 20 32

A space is printed using the set or programmed character pitch.

In the expanded and spaced modes the space width is increased accordingly.

Backspace

Control character Hexadecimal Decimal

BS 08 08

The print head is backsaced one space width.

Set 10 cpi (Pica)

ESC P 1B 50 27 80

The character pitch is set to 10 cpi.

Set 12 cpi (Elite)

ESC M 1B 4D 27 77

The character pitch is set to 12 cpi.

Page 91 of the Siemens 9014 user manual — Set/reset proportional spacing mode
Pagina 91 · klik om te vergroten
Pagina 91

Print carriage movements Epson LQ-2550 emulation

Set 15 cpi

ESC g 1B 67 27 103

The character pitch is set to 15 cpi.

Set/reset proportional spacing mode

ESC p p1 1B 70 p1 27 112 p1

In the proportional spacing mode, the character width differs. An i, for example, is narrower than an m.

Proportional spacing is possible with all fonts except the OCR fonts.

When the proportional mode is reset, the previously set character pitch becomes effective again.

p1 sets/resets the proportional spacing mode

Valid parameter values:

0 1 48 49

00 01 30 31

Reset proportional spacing mode Set proportional spacing mode Reset proportional spacing mode Set proportional spacing mode

Dec Hex Meaning

Page 92 of the Siemens 9014 user manual — Absolute horizontal tabulation
Pagina 92 · klik om te vergroten
Pagina 92

Print carriage movements Epson LQ-2550 emulation

Set character spacing mode

ESC SP p1 1B 20 p1 27 32 p1

This command sets the space between characters (spaced mode).

The space depends on the selected print quality.

p1 Space in 1/120 inch increments in DRAFT mode

Space in 1/180 inch increments in LQ/NLQ mode

RangeX’00 ≤ p 1 ≤ X’7F

Absolute horizontal tabulation

ESC $ p1 p2 1B 24 p1 p2 27 36 p1 p2

The print head is moved to the specified print position. The specified position is based on the set left margin and is defined in 1/60 inch increments.

p1 p2 define the absolute horizontal position

Horizontal position = (p1 + (p2 * 256)) * 1/60 inch

RangeX’00 ≤ p 1 ≤ X’FF
RangeX’00 ≤ p 2 ≤ X’03
Page 93 of the Siemens 9014 user manual — Relative horizontal tabulation
Pagina 93 · klik om te vergroten
Pagina 93

Print carriage movements Epson LQ-2550 emulation

Relative horizontal tabulation

ESC \ p1 p2 1B 5C p1 p2 27 92 p1 p2

The print head moves right or left the defined amount. The shift is based on the current print position and is defined in 1/120 (DRAFT) or 1/180 inch increments.

p1 p2 define the shift

p2 < X’80 causes a right shift.

Shift = (p1 + (p2 * 256)) * 1/120 inch (DRAFT mode)

Shift = (p1 + (p2 * 256)) * 1/180 inch (LQ/NLQ mode)

p2 ≥ X’80 causes a left shift.

Shift = 65536 - (p1 + (p2 * 256)) * 1/120 inch (DRAFT mode)

Shift = 65536 - (p1 + (p2 * 256)) * 1/180 inch (LQ/NLQ mode)

Range (Draft)X’00 ≤ p 1 ≤ X’FF^

X’00 ≤ p2 ≤ X’03

Range (NLQ/LQ)X’00 ≤ p 1 ≤ X’FF

X’00 ≤ p2 ≤ X’03

Page 94 of the Siemens 9014 user manual — HT 09 09
Pagina 94 · klik om te vergroten
Pagina 94

Print carriage movements Epson LQ-2550 emulation

Set horizontal tab stops

ESC D p1 ... pk NUL 1B 44 p1 ... pk 00 27 68 p1 ... pk 00

This command sets horizontal tab stops. Up to 32 horizontal tab stops can be defined. Previously set horizontal tab stops are reset.

The horizontal tab stops must be defined in ascending order in multiples of the current character pitch. The absolute horizontal tab stop locations depend on the current character pitch.

The set horizontal tab stops are not affected by later changes of the character pitch.

The default is every eighth column.

All horizontal tab stops are reset if no parameter is specified (ESC D NUL).

p1 ... pk Horizontal tab stops in multiples of the character pitch (1 ≤ k ≤ 32)

RangeX’01 ≤ p k ≤ X’FF

Horizontal tabulation

Control character Hexadecimal Decimal

HT 09 09

The control character may be located anywhere within a line and causes the next horizontal tab stop to be accessed. Repeating this control character causes horizontal tab stops to be skipped. HT, for example, causes the fourth horizontal tab stop to be accessed.

Conditions for horizontal tabulation:

G At least one horizontal tab stop must be set.

G The printer ignores the control character if no horizontal tab stops are set or if the end of the line would be exceeded.

G If the print head is on a set horizontal tab stop, the next horizontal tab stop is accessed.

Page 95 of the Siemens 9014 user manual — Set unidirectional print mode for one line
Pagina 95 · klik om te vergroten
Pagina 95

Print carriage movements Epson LQ-2550 emulation

Set print direction (bidirectional or unidirectional)

ESC U p1 1B 55 p1 27 85 p1

Unidirectional printing should be used if high positioning precision is required (e.g. in the graphics mode). The default is bidirectional printing.

p1 defines the print direction

Valid parameter values:

0 1 48 49

00 01 30 31

Bidirectional print direction Unidirectional print direction Bidirectional print direction Unidirectional print direction

The command is ignored if the menu setting does not permit unidirectional printing (see [2]).

Set unidirectional print mode for one line

ESC < 1B 3C 27 60

The unidirectional print mode should be used if high positioning precision is required (e.g. in the graphics mode). The default is bidirectional printing.

The command is ignored if the menu setting does not permit unidirectional printing (see [2]).

Dec Hex Meaning

Page 96 of the Siemens 9014 user manual — Select text alignment
Pagina 96 · klik om te vergroten
Pagina 96

Print carriage movements Epson LQ-2550 emulation

Select text alignment

ESC a p1 1B 61 p1 27 97 p1

The text alignment defines the horizontal position of a print line relative to the set margins (see Set left margin).

p1 defines the text alignment mode

Valid parameter values:

0 1 2 3

00 01 02 03

Left-justified text alignment Centered text alignment Right-justified text alignment Justification (left and right)

Horizontal tabulation and backspaces are ignored except for left-justified alignment.

Dec Hex Meaning

Page 97 of the Siemens 9014 user manual — Font design
Pagina 97 · klik om te vergroten
Pagina 97

Font design Epson LQ-2550 emulation

Font design

The following commands are available for font design:

G Select national version

G Select character set

G Set/reset user-defined character set

G Copy current character set into user-defined character set

G Define user-defined characters

G Select print quality

G Select character style

G Set italics mode

G Reset italics mode

G Set boldface mode

G Reset boldface mode

G Set double strike mode

G Reset double strike mode

G Set subscript/superscript mode

G Reset subscript/superscript mode

G Set condensed mode

G Reset condensed mode

G Set expanded mode for one line

G Set/reset expanded mode

G Reset expanded mode

G Set/reset double height mode

G Select print mode combination

G Set/reset underscore mode

G Set/reset line marking mode

G Select font · G Additional commands

Page 98 of the Siemens 9014 user manual — Select font
Pagina 98 · klik om te vergroten
Pagina 98

Font design Epson LQ-2550 emulation

Select font

ESC k p1 1B 6B p1 27 107 p1

The default character complement of the printer contains eleven fonts. Further fonts can be plugged in with a PROM on the PM (personality module).

p1 defines the font

Valid parameter values:

0 1 2 3 4 5 6 7 8

00 01 02 03 04 05 06 07 08

Roman Sans Serif Courier Prestige Script OCR-B OCR-A Orator-C Orator

The OCR-A and OCR-B fonts are machine-readable fonts. Machine readability is ensured only if the character pitch is 10 cpi.

Dec Hex Meaning

Page 99 of the Siemens 9014 user manual — Select national version
Pagina 99 · klik om te vergroten
Pagina 99

Font design Epson LQ-2550 emulation

Select national version

ESC R p1 1B 52 p1 27 82 p1

This command allows switching between national versions anywhere within the text.

In the initial condition, the printer uses the national version selected in the menu.

p1 defines the national version

Valid parameter values:

0 1 2 3 4 5 6 7 8 9 10 11 12 13 64

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 40

USA France Germany Great Britain Denmark 1 Sweden Italy Spain 1 Japan Norway Denmark 2 Spain 2 Latin America Turkey Legal

Dec Hex Meaning

Page 100 of the Siemens 9014 user manual — Set/reset user-defined character set
Pagina 100 · klik om te vergroten
Pagina 100

Font design Epson LQ-2550 emulation

Select character set

ESC t p1 1B 74 p1 27 116 p1

This command allows switching between character sets anywhere within the text.

In the initial condition, the printer uses the character set selected in the menu.

p1 defines the character set

Valid parameter values:

Epson ITALIC Epson EXT GCT User-defined character set

Set/reset user-defined character set

ESC % p1 1B 25 p1 27 37 p1

This command allows switching between the current character set and the user-defined character set anywhere within the text.

p1 defines the character set

Valid parameter values:

0 1 00 01 Current character set User-defined character set

Dec Hex Meaning · 00 01 02 · Dec Hex Meaning

Page 101 of the Siemens 9014 user manual — Copy current character set into user-defined character set
Pagina 101 · klik om te vergroten
Pagina 101

Font design Epson LQ-2550 emulation

Copy current character set into user-defined character set

ESC : NUL p1 NUL 1B 3A 00 p1 00 27 58 00 p1 00

This command copies the current character set into the user-defined character set.

p1 defines the font of the current character set

Valid parameter values:

0 1 2 3 4 5 6 7 8

00 01 02 03 04 05 06 07 08

Roman San Serif Courier Prestige Script OCR-B OCR-A Orator-C Orator

There must be sufficient memory space for the user-defined character set (see menu settings [2]). This can be done by setting the buffer size in the menu (see [2]) to a value < 32 Kbytes.

Dec Hex Meaning

Page 102 of the Siemens 9014 user manual — Define user-defined characters
Pagina 102 · klik om te vergroten
Pagina 102

Font design Epson LQ-2550 emulation

Define user-defined characters

ESC & NUL p1 p2 p3 p4 p5 data

1B 26 00 p1 p2 p3 p4 p5 data

27 38 00 p1 p2 p3 p4 p5 data

One or several characters can be defined. If the current character set was loaded in the user-defined character set beforehand, the characters defined by this command are replaced.

p1 specifies the code location of the first character to be defined

RangeX’00 to X’7F

p2 specifies the code location of the last character to be defined

Rangep 1 to X’7F

p3 specifies the number of leading blank columns of the character to be defined

RangeX’00 to X’2A (1 to 42 columns)

p4 specifies the number of dot columns of the character to be defined

RangeX’00 to X’25 (1 to 37 columns)

p5 specifies the number of trailing blank columns of the character to be defined

RangeX’00 to X’2A (1 to 42 columns)

Data Data bytes containing the dot information

Range: X’00 to X’FF (any bit of a byte may be 1 (dot) or 0 (no dot))

Page 103 of the Siemens 9014 user manual — DRAFT
Pagina 103 · klik om te vergroten
Pagina 103

Font design Epson LQ-2550 emulation

Meaning of parameters p3, p4 and p5:

Print mode Spacing p3+p4+ p5 max.

p4 max.

1/120 inch

DRAFT

LQ

1/360 inch

Proportional 42 37 1/360 inch

The character information is transferred in 3 bytes per column. The number of data bytes to be transferred is thus 3 x p4 bytes. If you define more than one character, parameters p3, p4 and p5 must be defined before the dot information of the characters.

There must be sufficient memory space for the user-defined character set (see menu settings [2]).

The function is only valid with 8-bit data transfer (for the menu setting see [2]).

Show 5 more labels / short text on this page
Horizontal resolution · 10 cpi · 12 cpi · 10 cpi · 12 cpi
Page 104 of the Siemens 9014 user manual — – ESC & NUL X’33 X’33
Pagina 104 · klik om te vergroten
Pagina 104

Font design Epson LQ-2550 emulation

Leading Dot columns Trailing blank columns of the character blank columns P3 P4 P5

1 1 2 3 4 5 6 7 8 9 1 2

20 21 22 23 24 25 26 27

o . o . o . o . o . . o . . . o o . o . o o . . . o . o . o . o . o

20 21 22 23 24 25 26 27 20 21 22 23 24 25 26 27

Byte values FF 00 01 00 01 00 01 00 01 First byte for dot columns FF 00 02 00 07 00 Second byte (Hex.) 07 00 04 00 04 00 04 00 04 Third byte

To load this character (in DRAFT and 10 cpi) in code location X’21 (decimal 33), the following control characters have to be sent to the printer:

– ESC x 0 Set draft mode.

– ESC P Set 10 cpi.

Define character (from code location 33 (X’21) to code location 33 (X’21), i.e. one character in this code location. 1 leading blank column, 9 dot columns and 2 trailing blank columns. Data containing the dot information. (Hex.) In this representation, three bytes of a dot column are combined for clarity.

– ESC & NUL X’33 X’33

X’01 X’09 X’02

X’FFFF07 X’000000 X’010204 X’000000 X’010704 X’000000 X’010004 X’000000 X’010004

Show 4 more labels / short text on this page
Example · First byte · Second byte · Third byte
Page 105 of the Siemens 9014 user manual — Select character style
Pagina 105 · klik om te vergroten
Pagina 105

Font design Epson LQ-2550 emulation

Select print quality

ESC x p1 1B 78 p1 27 120 p1

DRAFT or LQ/NLQ is selected.

In the initial condition, the print quality is defined by the menu setting (see [2]).

p1 defines the print quality

Valid parameter values:

0 1 48 49

00 01 30 31

DRAFT mode NLQ or LQ mode DRAFT mode NLQ or LQ mode

Select character style

ESC q p1 1B 71 p1 27 113 p1

The character style can be selected with this command.

p1 defines the character style

Valid parameter values:

0 1 2 3

00 01 02 03

Normal character style Outline Shadow Outline + shadow

Dec Hex Meaning · Dec Hex Meaning

Page 106 of the Siemens 9014 user manual — Set italics mode
Pagina 106 · klik om te vergroten
Pagina 106

Font design Epson LQ-2550 emulation

Set italics mode

ESC 4 1B 34 27 52

Reset italics mode

ESC 5 1B 35 27 53

Set boldface mode

ESC E 1B 45 27 69

Reset boldface mode

ESC F 1B 46 27 70

Set double strike mode

ESC G 1B 47 27 71

Reset double strike mode

ESC H 1B 48 27 72

Page 107 of the Siemens 9014 user manual — Reset subscript/superscript mode
Pagina 107 · klik om te vergroten
Pagina 107

Font design Epson LQ-2550 emulation

Set subscript/superscript mode

ESC S p1 1B 53 p1 27 83 p1

This command causes reduced-size characters to be superscripted, i.e. printed as exponents, or subscripted, i.e. printed as indices.

Superscripted characters (exponents) are printed approx. 1/2 line up. Subscripted characters (indices) are only reduced in size and printed on the base line.

p1 defines the subscript or superscript mode

Parameter values:

0 1 48 49

00 01 30 31

Set superscript mode Set subscript mode Set superscript mode Set subscript mode

The menu setting must be INDEX/EXPONENT (see [2]).

Reset subscript/superscript mode

ESC T 1B 54 27 84

Resets the subscript/superscript function.

Dec Hex Meaning

Page 108 of the Siemens 9014 user manual — DC2 12 18
Pagina 108 · klik om te vergroten
Pagina 108

Font design Epson LQ-2550 emulation

Set condensed mode

SI 0F 15

ESC SI 1B 0F 27 15

The two commands are identical in function. The characters are printed in compressed form.

The resulting character pitch depends on the current character pitch.

Current character pitch in cpi

Compressed character pitch in cpi

10 12 15 Proportional

17 20 Unchanged Proportional compressed

Reset condensed mode

Control character Hexadecimal Decimal

DC2 12 18

Set expanded mode for one line

SO 0E 14

ESC SO 1B 0E 27 14

The two commands are identical in function. The characters are printed with double width in one line.

The function is terminated by the LF, CR, VT, FF, DC4 and ESC W 0 commands.

Page 109 of the Siemens 9014 user manual — DC4 14 20
Pagina 109 · klik om te vergroten
Pagina 109

Font design Epson LQ-2550 emulation

Set/reset expanded mode

ESC W p1 1B 57 p1 27 87 p1

In the expanded mode, the characters are printed with double width.

p1 sets/resets the expanded mode

Valid parameter values:

0 1 48 49

00 01 30 31

Reset expanded mode Set expanded mode Reset expanded mode Set expanded mode

Reset expanded mode

Control character Hexadecimal Decimal

DC4 14 20

Set/reset double height mode

ESC w p1 1B 77 p1 27 119 p1

The characters are printed with double height.

p1 sets/resets the double height mode

Valid parameter values:

0 1 48 49

00 01 30 31

Reset double height mode Set double height mode Reset double height mode Set double height mode

Dec Hex Meaning · Dec Hex Meaning

Page 110 of the Siemens 9014 user manual — Set/reset underscore mode
Pagina 110 · klik om te vergroten
Pagina 110

Font design Epson LQ-2550 emulation

Select print mode combinations

ESC ! p1 1B 21 p1 27 33 p1

The following characters are printed using the print mode combinations defined by parameter p1.

The command can be used with all fonts and font sizes.

p1 Print mode combinations; interpreted bitwise

Bit position Bit set (bit = 1) Bit reset (bit = 0)

0 1 2 3 4 5 6 7

12 cpi Set proportional mode Set condensed mode Set boldface mode Set double strike mode Set expanded mode Set italics mode Set underscore mode

10 cpi Reset proportional mode Reset condensed mode Reset boldface mode Reset double strike mode Reset expanded mode Reset italics mode Reset underscore mode

Set/reset underscore mode

ESC - p1 1B 2D p1 27 45 p1

The characters are underscored.

p1 sets/resets the underscore mode

Valid parameter values:

00 01 Reset underscore mode Set underscore mode

Dec Hex Meaning

Page 111 of the Siemens 9014 user manual — Set/reset line marking mode
Pagina 111 · klik om te vergroten
Pagina 111

Font design Epson LQ-2550 emulation

Set/reset line marking mode

ESC ( - p1 p2 p3 p4 p5 1B 28 2D p1 p2 p3 p4 p5 27 40 45 p1 p2 p3 p4 p5

The following characters are printed with an additional line mark.

p1 = X’03 fixed value

p2 = X’00 fixed value

p3 = X’01 fixed value

p4 defines the position of the line mark

Valid parameter values:

Underscore Cross out Overscore

p5 defines the type of line mark

Valid parameter values:

0 1 2 5 6

00 01 02 05 06

Deactivates the line mark selected with p1 Single solid line Double solid line Single dashed line Double dashed line

Dec Hex Meaning · 01 02 03 · Dec Hex Meaning

Page 112 of the Siemens 9014 user manual — Additional commands
Pagina 112 · klik om te vergroten
Pagina 112

Font design Epson LQ-2550 emulation

Additional commands

Graphical change of sizes

ESC [ p1; p2 SP B 1B 5B p1 3B p2 20 42 27 91 p1 59 p2 32 66

Valid values:

p1 = 100 / p2 = 100

Normal height / normal width

p1 = 200 / p2 = 200

Double height / Double width

p1 = 300 / p2 = 300

Triple height / Triple width

p1 = 400 / p2 = 400

Quadruple height / Quadruple width

p1 and p2 max. = 800 (in steps of 100)

Graphical change of size for DATA LARGE:

p1 = 100 / p2 = 100

Normal height / normal width

p1 and p2 max. = 9900 (in steps of 100)

Page 113 of the Siemens 9014 user manual — Additional commands
Pagina 113 · klik om te vergroten
Pagina 113

Font design Epson LQ-2550 emulation

Set national version and code page

ESC [ p1; p2 w 1B 5B p1 3B p2 77 27 91 p1 59 p2 119

p1 = 1 to 15

For national version EPSON EXT.GCT:

p 1 = 1U.S.A
p 1 = 2France
p 1 = 3Germany

p1 = 4 : U.K.

p 1 = 5Denmark 1
p 1 = 6Sweden
p 1 = 7Italy
p 1 = 8Spain 1
p 1 = 9Japan
p 1 = 10Norway
p 1 = 11Denmark 2
p 1 = 12Spain 2
p 1 = 13Latin AM
p 1 = 14Turkey
p 1 = 15Legal

p2 = 3 digit code of the code table

p2 = d3 d2 d1 (three digits)

0 6 1 IBM set 1

0 6 2 IBM set 2

0 6 3 IBM code page

0 7 1 Epson EXT GCT

Page 114 of the Siemens 9014 user manual — Additional commands
Pagina 114 · klik om te vergroten
Pagina 114

Font design Epson LQ-2550 emulation

ESC [ p1 w 1B 5B p1 77 27 91 p1 119

See the command “Set national version and code page” for the setting of p1.

ESC [ ; p2 w 1B 5B 3B p2 77 27 91 59 p2 119

See the command “Set national version and code page” for the setting of p2.

Set national version · Set code page

Page 115 of the Siemens 9014 user manual — OCR-A
Pagina 115 · klik om te vergroten
Pagina 115

Font design Epson LQ-2550 emulation

Set character pitch and select font

ESC [ p1 ; p2 x 1B 5B p1 3B p2 78 27 91 p1 59 p2 120

p1 = 1

p1 = 2

p1 = 3

p1 = 4

p1 = 5

p1 = 6

p1 = 7

OCR-B

p1 = 8

OCR-A

p1 = 9

p1 = 10

p1 = 11

p2 = 1

p2 = 2

p2 = 3

Show 14 more labels / short text on this page
Data · Roman · Sans Serif · Courier · Prestige · Script · Orator-C · Orator · Data-Block · p1 = 12 · Data Large · 10 cpi · 12 cpi · 15 cpi
Page 116 of the Siemens 9014 user manual — NLQ
Pagina 116 · klik om te vergroten
Pagina 116

Font design Epson LQ-2550 emulation

p2 = 4

p2 = 5

p2 = 6

14.4 cpi

p2 = 7

p2 = 8

17.1 cpi

p2 = 9

ESC [ p1 x 1B 5B p1 78 27 91 p1 120

See the command “Set character pitch and select font” for the setting of p1.

Set print quality (NLQ, LQ)

ESC [ p1 SP X 1B 5B p1 20 58 27 91 p1 32 88

p1 = 0

LQ

p1 = 1

NLQ

This is only valid if the NLQ type style is available.

Show 5 more labels / short text on this page
Proportional · Proportional · 18 cpi · 20 cpi · Select font
Page 117 of the Siemens 9014 user manual — Select graphics mode
Pagina 117 · klik om te vergroten
Pagina 117

Bitmap graphics Epson LQ-2550 emulation

Bitmap graphics

The following commands are available:

G Select graphics mode

G Reassign graphics mode

Select graphics mode

ESC * p1 p2 p3 data 1B 2A p1 p2 p3 data 27 42 p1 p2 p3 data

The graphics data is transferred in columns. A column contains either 8 or 24 individual vertical dots.

Each graphics line begins with this command, which defines the graphics mode (vertical and horizontal resolution). A defined number of pixel data items follows. The number of columns is defined by parameters p2 and p3.

Siemens 9014 — Select graphics mode diagram (page 117)
Afb. 11 · Select graphics mode
Figure 7Vertical dot density 60 dpi
Page 118 of the Siemens 9014 user manual — Bitmap graphics
Pagina 118 · klik om te vergroten
Pagina 118

Bitmap graphics Epson LQ-2550 emulation

Siemens 9014 — Bitmap graphics diagram (page 118)
Afb. 12 · Bitmap graphics
Figure 8Vertical dot density 180 dpi
Page 119 of the Siemens 9014 user manual — ESC Z
Pagina 119 · klik om te vergroten
Pagina 119

Bitmap graphics Epson LQ-2550 emulation

p1 defines the graphics mode

Valid parameter values:

Dec Hex Meaning Number of needles

dpi Compatible commands hori- zontal

Single density Double density Double density and high speed 1)

ESC K ESC L ESC Y

3 4 6 32 33 38 39 40

03 04 06 20 21 26 27 28

8 8 8 24

240 80 90 60 120 90 180 360

60 60 60 180

ESC Z

CRT 1 CRT 2 Single density Double density CRT 3 Triple density Sixfold density1)

1. In this mode, printing in adjacent columns is not possible.

p2 p3 define the number of columns

Number of columns = p2 + (p3 * 256)

Data Data bytes containing the dot information

Show 5 more labels / short text on this page
verti- cal · 00 01 02 · 60 120 120 · 60 60 60 · Quadruple density 1)
Page 120 of the Siemens 9014 user manual — 4B 4C 59 5A
Pagina 120 · klik om te vergroten
Pagina 120

Bitmap graphics Epson LQ-2550 emulation

Reassign graphics mode

ESC ? p1 p2 1B 3F p1 p2 27 63 p1 p2

This command assigns new graphics modes to the commands:

ESC K p1 p2 data ESC L p1 p2 data ESC Y p1 p2 data ESC Z p1 p2 data

p1 defines the graphics command

Valid parameter values:

Dec Hex Graphics command

75 76 89 90

4B 4C 59 5A

ESC K ESC L ESC Y ESC Z

p2 defines the graphics mode

Valid parameter values:

Dec Hex Mode Number of needles

Single density Double density Double density and high speed 1)

3 4 6 32 33 38 39 40

03 04 06 20 21 26 27 28

8 8 8 24

240 80 90 60 120 90 180 360

60 60 60 180

CRT 1 CRT 2 Single density Double density CRT 3 Triple density Sixfold density 1)

1. In this mode, printing in adjacent columns is not possible.
Show 7 more labels / short text on this page
dpi · hori- zontal · verti- cal · 00 01 02 · 60 120 120 · 60 60 60 · Quadruple density1)
Page 121 of the Siemens 9014 user manual — Printing characters between X’80 and X’9F
Pagina 121 · klik om te vergroten
Pagina 121

Miscellaneous commands

G Control characters between X’80 and X’9F

G Printing characters between X’80 and X’9F

G Reset most significant bit (MSB) to zero

G Set most significant bit (MSB) to one

G Delete most significant bit (MSB) default

G Set printer online

G Set printer offline

G Clear line buffer

Control characters between X’80 and X’9F

ESC 7 1B 37 27 55

Codes X’80 to X’9F are replaced by control codes X’00 to X’1F.

Printing characters between X’80 and X’9F

ESC 6 1B 36 27 54

The characters in this code table area are printing characters.

This command is ignored if the Epson ITALIC character set was selected (see Select character set).

Show 4 more labels / short text on this page
G Delete character · G Audible signal · G NUL function · G Additional commands
Page 122 of the Siemens 9014 user manual — Delete most significant bit (MSB) default
Pagina 122 · klik om te vergroten
Pagina 122

Miscellaneous commands Epson LQ-2550 emulation

Reset most significant bit (MSB) to zero

ESC = 1B 3D 27 61

Resets the most significant bit of all incoming data to zero.

This command restricts parameters to the range from 0 to 127.

Set most significant bit (MSB) to one

ESC > 1B 3E 27 62

Sets the most significant bit of all incoming data to one.

This command restricts parameters to the range from 128 to 255.

Delete most significant bit (MSB) default

ESC # 1B 23 27 35

This command deletes the default MSB specification.

Page 123 of the Siemens 9014 user manual — DEL 7F 127
Pagina 123 · klik om te vergroten
Pagina 123

Miscellaneous commands Epson LQ-2550 emulation

Set printer online

Control character Hexadecimal Decimal

DC1 11 17

Returns the printer to the online mode after the Set printer offline command.

The command is ineffective if the printer was set offline with the online button.

Set printer offline

Control character Hexadecimal Decimal

DC3 13 19

Sets the printer offline. All following data is ignored except for the Set printer online command.

The printer cannot be set online with the online button.

Clear line buffer

Control character Hexadecimal Decimal

CAN 18 24

Deletes the contents of the line buffer to the next control character.

Delete character

Control character Hexadecimal Decimal

DEL 7F 127

Deletes the character received last.

Page 124 of the Siemens 9014 user manual — $$/ 24 24 2F 36 36 47
Pagina 124 · klik om te vergroten
Pagina 124

Miscellaneous commands Epson LQ-2550 emulation

Audible signal

Control character Hexadecimal Decimal

BEL 07 07

This control character has no effect.

NUL function

Control character Hexadecimal Decimal

NUL 00 00

This control character has no effect.

Additional commands

$$ 24 24 36 36

This command replaces the control character sequence ESC [, hexadecimal 1B 5B, decimal 27 91.

$$/ 24 24 2F 36 36 47

This command replaces the control character sequence ESC, hexadecimal 1B, decimal 27.

Command replacement $$ · Command replacement $$/

Page 125 of the Siemens 9014 user manual — Audible signal
Pagina 125 · klik om te vergroten
Pagina 125

Miscellaneous commands Epson LQ-2550 emulation

ESC [ p1 ; p2 SP r 1B 5B p1 3B p2 20 72 27 91 p1 59 p2 32 114

p1 can have the values 1 to 4.

p2 selects the emulation

p2 = 2

p2 = 3

p2 = 4

Show 4 more labels / short text on this page
Macro selection · IBM Proprinter · IBM Proprinter, AGM · Epson LQ-2550
Page 126 of the Siemens 9014 user manual — Set page format
Pagina 126 · klik om te vergroten
Pagina 126

ESC / P2 Commands Epson LQ-2550 emulation

ESC / P2 Commands

G Set page format

G Set page length in defined units

G Set absolute vertical print position

G Set relative vertical print position

G Select font by pitch and point

G Set horizontal motion index (HMI)

G Assign character table

G Select character table

G Print data as characters

G Select graphics mode

G Print raster graphics

Set page format

ESC ( c p1 p2 p3 p4 p5 1B 28 63 p1 p2 p3 p4 p5 27 40 99 p1 p2 p3 p4 p5

This command sets top and bottom margins in defined units.

p1 = 04 00

tm = p2 + p3 * 256

tmtop margin in defined units

bm = p4 + p5 * 256

bmbottom margin in defined units

G Set unit

Page 127 of the Siemens 9014 user manual — Set absolute vertical print position
Pagina 127 · klik om te vergroten
Pagina 127

ESC / P2 Commands Epson LQ-2550 emulation

Set page length in defined units

ESC ( C p1 p2 p3 1B 28 43 p1 p2 p3 27 40 67 p1 p2 p3

p1 = 02 00

pl = p2 + p3 * 256

plnumber of defined units

Set absolute vertical print position

ESC ( V p1 p2 p3 1B 28 56 p1 p2 p3 27 40 86 p1 p2 p3

p1 = 02 00

p = p2 + p3 * 256

p: defines print position from top margin in defined units

Page 128 of the Siemens 9014 user manual — Select font by pitch and point
Pagina 128 · klik om te vergroten
Pagina 128

ESC / P2 Commands Epson LQ-2550 emulation

Set relative vertical print position

ESC ( v p1 p2 p3 1B 28 76 p1 p2 p3 27 40 118 p1 p2 p3

p1 = 02 00

p = p2 + p3 * 256

p: moves the print position from top margin in defined units

Select font by pitch and point

ESC X p1 p2 p3 1B 58 p1 p2 p3 27 88 p1 p2 p3

p1= 0

No change in pitch

p1 = 1

p1 = 18, 24, 30, 36, 42, 48, 60 oder 72

Selects fixed pitch equal to 360/p1 cpi

p = p2 +p3 * 256

p: Point size in 0,5 points = p2 + p3 * 256

1 point = 1/72 Zoll

No change in point size

p = 16, 21, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Selects proportional spacing · p = 0

Page 129 of the Siemens 9014 user manual — Set horizontal motion index (HMI)
Pagina 129 · klik om te vergroten
Pagina 129

ESC / P2 Commands Epson LQ-2550 emulation

Set unit

ESC ( U p1 p2 1B 28 55 p1 p2 27 40 85 p1 p2

This command defines the unit used for positioning in n/3600 inches. This definition is valid for the following commands:

Set page format ESC ( c p1 p2 p3 p4 p5 Set page length in defined units ESC ( C p1 p2 p3 Set absolute vertical print position ESC ( V p1 p2 p3 Set relative vertical print position ESC ( v p1 p2 p3

p1 = 01 00

p2 = 10, 20, 30, 40, 50, 60 /3600”

Standardp 2 = 10

Set horizontal motion index (HMI)

ESC c p1 p2 1B 63 p1 p2 27 99 p1 p2

Selects pitch in steps of n/360”.

HMI = p1 + p2 * 256

HMI max. 3 Zoll.

Page 130 of the Siemens 9014 user manual — Select character table
Pagina 130 · klik om te vergroten
Pagina 130

ESC / P2 Commands Epson LQ-2550 emulation

Assign character table

ESC ( t p1 p2 p3 p4 p5 1B 28 74 p1 p2 p3 p4 p5 27 40 116 p1 p2 p3 p4

p2 = 0

p3 Character table, selected via p4 and p5

range0, 1, 2, 3, “0”, “1”, “2” oder “3”

p4 p5 character table

0 0 : Kursiv 1 0: PC 437 (USA) 3 0: PC 850 (Multilingual) 7 0: PC 860 (Portugal) 8 0 PC 863 (French-Canada) 9 0 PC 865 (Norway) 44 0 PC 858

p4 and p5 are Decimal-characters

Four character tables can be assigned:

0 ≤ p3 ≤ 3 or 48 ≤ p3 ≤ 51

The command select character table will activate the assigned character table.

Select character table

ESC t p1 1B 74 p1 27 116 p1

p1 = 0, 1, 2, 3, “0”, “1”, “2” oder “3”

This command selects one of the four character tables which are assigned by the command assign character table.

p1 = 3

Page 131 of the Siemens 9014 user manual — Select graphics mode
Pagina 131 · klik om te vergroten
Pagina 131

ESC / P2 Commands Epson LQ-2550 emulation

Print data as characters

ESC ( ^ p1 p2 data 1B 28 5E p1 p2 27 40 94 p1, p2

This command prints data as characters.

p1 + p2 * 256 p = sum of data (number of bytes, which are to be printed as characters, not control codes)

Data:

p bytes of data to be printed as characters

Select graphics mode

ESC ( G p1 p2 1B 28 47 p1 p2 27 40 71 p1, p2

p1= 01 00

p2 = 1 or 49

Graphics mode may be reset by ESC @.

p = · selects graphics mode

Page 132 of the Siemens 9014 user manual — Print raster graphics
Pagina 132 · klik om te vergroten
Pagina 132

ESC / P2 Commands Epson LQ-2550 emulation

Print raster graphics

ESC . p1 p2 p3 p4 p5 p6 1B 2E p1 p2 p3 p4p5 p6 27 46 p1 p2 p3 p4p5 p6

graphics mode (not compressed)

p2 = 5, 10, 20

vertical resolution in 3600/p2 dpi

p3 = 5, 10, 20

horizontal resolution in 3600/p2 dpi

p4 = vertical dot count

range1 ≤ p 1 ≤ 24

p = p5 + p6 * 256

p: horizontal dot count

The following combination is not possible:

p2 = 10, p3 = 20

p1 = 0 · p1 = 1 · graphics mode, compressed

Page 133 of the Siemens 9014 user manual — G POSTNET
Pagina 133 · klik om te vergroten
Pagina 133

Barcodes

You can print the following barcodes with the 901x printer:

G 2 out of 5 Industrial

G 2 out of 5 Interleaved

G EAN-8 and EAN-13

– EAN-8 and EAN-13 Add-on (EAN Add-On 2 and EAN Add-On 5)

G MSI Mod 10/10

G UPC-A and UPC-E

– Code UPC-A and UPC-E Add-on (EAN Add-On 2 and EAN Add-On 5)

G Code 128 (EAN 128)

G POSTNET

Programming examples for the different barcode types are given on page 150 and up.

G Code 39 · G Codabar (Monarch) · G Code 93

Page 134 of the Siemens 9014 user manual — Code 39
Pagina 134 · klik om te vergroten
Pagina 134

General information

The print tolerance is smaller for horizontal barcodes than it is for vertical barcodes. Horizontal barcodes are automatically printed in unidirectional mode to ensure maximum accuracy. Vertically printed barcodes may be adversely affected by paper feed tolerances especially in the lower third of the last page of continuous form or on single sheets. This is why barcodes with small elements widths should be avoided.

The barcode symbol must fully fit on the logical page and must not exceed the page bound- aries.

The number of characters including control, start and stop characters for a barcode symbol is limited to 50. Most barcode specifications and barcode reading systems accept far fewer characters per symbol.

It is recommended to check barcode applications and reading systems for compatibility.

The original printouts of all barcode symbols in the programming examples have been checked with commercially available barcode readers.

Code 39

The character complement of the Code 39 comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9

– 26 letters: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

– 7 special charactersSpace $ % + - . /
– 1 start/stop character*

The extended Code 39 allows the entire ASCII character set to be represented by combining one of the special characters with a letter.

The number of characters is variable. The start/stop characters are programmed with the special character *. In the plain text line, the character * is printed for start/stop.

The symbol layout is self-checking. A check digit is not required. If a check digit is to be used, it must be programmed in the application (and must be modulo 43). The Code 39 has the safest and most reliable structure among the industrial barcodes.

The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom- mended for applications.

The barcode height should be 25% of the barcode length or 20 mm, whichever is greater. A barcode should consist of no more than 20 characters.

Code 39 Barcodes

Page 135 of the Siemens 9014 user manual — 2 out of 5 Industrial
Pagina 135 · klik om te vergroten
Pagina 135

2 out of 5 Industrial Barcodes

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

Reference table for check digit calculation:

0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A 10 B 11 C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21 M 22

N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31 W 32 X 33 Y 34 Z 35 - 36 . 37 Sp 38 $ 39 / 40 + 41 % 42

Example of check digit calculation modulo 43:

Information charactersCODE 39
Sum of reference digits12+24+13+14+38+3+9=113
Modulo 43113 mod 43 = 27 (113/43 = rem. 27)
Check digit27
Printable characterR (= 27)

2 out of 5 Industrial

The character complement of the 2 out of 5 Industrial code comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9
– Start/stop characters:/; </=

The number of characters is variable.

The start/stop characters are programmed with the characters : and ;. Alternatively, the characters < and = can be used as start/stop characters.

In the plain text line, the characters . and ; or < and = are printed for start/stop.

The symbol layout is self-checking. A check digit is not required but should be used (modulo 10 with a weighting of 3). The check digit must be programmed in the application.

The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom- mended for applications.

The code permits large tolerances between ±15% and 20%.

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

Page 136 of the Siemens 9014 user manual — 2 out of 5 Interleaved
Pagina 136 · klik om te vergroten
Pagina 136

2 out of 5 Interleaved Barcodes

2 out of 5 Interleaved

The character complement of the 2 out of 5 Interleaved code comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9
– Start/stop characters:/; </=

The number of characters is variable but must be even. If the number of characters is odd, a 0 is prefixed to make it even.

The start/stop characters are programmed with the characters : and ;. Alternatively, the characters < and = can be used as start/stop characters.

In the plain text line, the characters : and ; or < and = are printed for start/stop.

The symbol layout is self-checking. A check digit is not required. If a check digit is to be used, it must be programmed in the application (and must be modulo 10 with a weighting of 3).

The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom- mended for applications.

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

Page 137 of the Siemens 9014 user manual — EAN-8 and EAN-13
Pagina 137 · klik om te vergroten
Pagina 137

EAN-8 and EAN-13 Barcodes

Codabar

The character complement of the Codabar (Monarch) code comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9
– 6 special characters- $ : / . +
– Start/stop charactersa/t, b/n, c/*, d/e

The number of characters is variable. The start/stop characters are programmed with the characters a/t, b/n, c/*, d/e. In the plain text line these characters are printed for start/stop.

The symbol layout is self-checking. A check digit is not required and is rarely used. The check digit must be programmed in the application.

The check digit method is modulo 16. In practice, modulo 10 with a weighting of 3 or modulo 11 are also used.

The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom- mended for applications.

The barcode height should be 25% of the barcode length or 20 mm, whichever is greater.

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

EAN-8 and EAN-13

The EAN-8 and EAN-13 codes have a character set of 10 digits. The number of characters is fixed and is 8 for EAN-8 and 13 for EAN-13.

Layout of EAN-8:

– Two digits for the manufacturer’s country

– Five digits for small-sized products

– One check digit

Page 138 of the Siemens 9014 user manual — EAN-8 EAN-13
Pagina 138 · klik om te vergroten
Pagina 138

EAN-8 and EAN-13 Barcodes

Layout of EAN-13:

– Two digits for the manufacturer’s country

– Five digits for the manufacturer

– Five digits for the product

– One check digit

The border and separator characters are automatically generated by the printer. All characters are also printed as plain text.

The symbol layout is self-checking. A check digit is required. The check digit must be programmed in the application (and must be modulo 10 with a weighting of 3).

The code can be printed in the three sizes SC3, SC6 and SC9. The height of the symbol is variable but should be programmed to approximately match the width of the symbol.

The following minimum blank zones should be observed:

Size Blank zones in mm

Left of symbol Right of symbol

EAN-8 EAN-13

SC3 2.6 4.0 2.6

SC6 3.6 5.5 3.6

SC9 4.7 7.3 4.7

Page 139 of the Siemens 9014 user manual — Code 93
Pagina 139 · klik om te vergroten
Pagina 139

EAN-8 and EAN-13 Add-on

The EAN-8 and EAN-13 codes with a two or five-digit add-on are printed automatically if two or five additional digits are programmed in the application.

The check digit calculation ignores the add-on digits.

Example of check digit calculation modulo 10 with a weighting of 3:

Plain text4 1 2 3 4 5 6 7 8 9 0 1 8
Check digit8
Information digit sequence4 1 2 3 4 5 6 7 8 9 0 1
Weighting factors1 3 1 3 1 3 1 3 1 3 1 3
Products4 3 2 9 4 15 6 21 8 27 0 3
Sum of products4+3+2+9+4+15+6+21+8+27+0+3=102
Modulo 10102 mod 10 = 2 (102/10 = remndr. 2)

Difference from 10 is check digit : 10-2=8

Check digit8

Code 93

The character complement of the Code 93 code comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9

– 26 letters: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

– 7 special charactersSpace $ % + - . /

– 4 control characters: (X’67 in ISO 7-bit or X’87 in EBCDIC) (X’68 in ISO 7-bit or X’88 in EBCDIC) (X’69 in ISO 7-bit or X’89 in EBCDIC) (X’6A in ISO 7-bit or X’91 in EBCDIC)

– 1 start character(X’61 in ISO 7-bit or X’81 in EBCDIC)
– 1 stop character(X’65 in ISO 7-bit or X’85 in EBCDIC)

The number of characters is variable. The start/stop characters are programmed with the characters, e.g. a/e.

Code 93 Barcodes · $ · %

Page 140 of the Siemens 9014 user manual — EAN-8 and EAN-13 Add-on
Pagina 140 · klik om te vergroten
Pagina 140

In the plain text line, the special characters [ ] are printed for start/stop. All characters including the start, stop, control and check characters are also printed in the plain text line.

The symbol layout is not self-checking. Two check digits, C and K, are required and must be programmed in the application. The modulo 47 check digit layout is for the check digit C with a weighting of 1 to 10, for the check digit K with a weighting of 1 to 15.

The barcode height should be 15% of the barcode length or 0.25 inch, whichever is greater.

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

Reference table for check digit calculation:

0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A 10 B 11 C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21

M 22 N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31 W 32 X 33 Y 34 Z 35 - 36 . 37 Sp 38 $ 39 / 40 + 41 % 42 ($) 43

(%) 44 (/) 45 (+) 46

Code 93 Barcodes

Page 141 of the Siemens 9014 user manual — EAN-8 and EAN-13 Add-on
Pagina 141 · klik om te vergroten
Pagina 141

Example of check digit calculation:

Plain textC + O + D + E SP 9 3 W I
Check digit CW (weighting of 1, 2, ... 10, 1, 2, ... from right to left)
Check digit KI (weighting of 1, 2, ... 15, 1, 2, ... from right to left)

Information char seq. : C + O + D + E SP 9 3

Reference values12 41 24 41 13 41 14 38 9 3

Weighting factors for check digit C : 10 9 8 7 6 5 4 3 2 1

Weighting factors for check digit K : 11 10 9 8 7 6 5 4 3 2 1

Sum of products for check digit C :

(12*10) + (41*9) + (24*8) + (41*7) + (13*6) + (41*5) + (14*4) + (38*3) + (9*2) + (3*1) = 1442

Modulo 471442 mod 47 = 32 (1442/47 = 30, remainder 32)
Check digit CW (W corresponds to the reference number 32)

Sum of products for check digit K

: (12*11) + (41*10) + (24*9) + (41*8) + (13*7) + (41*6)

+ (14*5) + (38*4) + (9*3) + (3*2) + (32*1) = 1710

Modulo 471710 mod 47 = 18 (1770/47 = 36, remainder 18)
Check digit KI (I corresponds to the reference number 18)

The following characters are provided for coding the start and stop characters:

– Start charactera, b, c, d or s (hexadecimal: 61, 62, 63, 64 or 73)
– Stop charactere or f (hexadecimal: 65 or 66)

Code 93 Barcodes · Check character

Page 142 of the Siemens 9014 user manual — MSI Mod 10/10
Pagina 142 · klik om te vergroten
Pagina 142

MSI Mod 10/10 Barcodes

The control characters are coded as follows:

– ($) hexadecimal67
– (%) hexadecimal68
– (/) hexadecimal69
– (*) hexadecimal6A

The control characters are printed in plain text within a closed circle.

MSI Mod 10/10

The character complement of the MSI Mod 10/10 code comprises:

– 10 digits0 1 2 3 4 5 6 7 8 9
– 1 start character: (X’3A in ISO 7-bit or X’7A in EBCDIC)
– 1 stop character; (X’3B in ISO 7-bit or X’5E in EBCDIC)

The number of characters is variable. The start/stop characters are programmed with the characters : and ;.

In the plain text line, these characters are printed for start/stop.

A check digit is required and must be programmed in the application (and must be modulo 10 from a checksum generated in several stages).

The ratio of wide to narrow elements is fixed and is always 2 : 1.

The blank zone before and after the barcode symbol should be at least 10 times the width of a narrow element.

Page 143 of the Siemens 9014 user manual — UPC-A
Pagina 143 · klik om te vergroten
Pagina 143

UPC-A and UPC-E Barcodes

Example of check digit calculation

Plain text1 2 3 4 5 6 7 4 1
Plain text w/o check digit1 2 3 4 5 6 7 4
Check digit1

New number generated from odd positions : 2 4 6 4

Multiplied by 22464 x 2 = 4928
Sum of digits4 + 9 + 2 + 8 = 23

Sum of the even positions of the original number and sum from the last step : 1 + 3 + 5 + 7 + 23 = 39

Modulo 1039 mod 10 = 9 (39/1110 = 3, rem. 9)

Difference from 10 is the check digit : 10 - 9 = 1

Check digit1

UPC-A and UPC-E

The number of characters in the UPC-A and UPC-E codes is fixed and is eight digits for UPC-E and twelve digits for UPC-A. The border and separator characters are automatically generated by the printer.

UPC-A

The UPC-A code has the following layout:

– One digit as the system identifier

0 = Standard consumer goods

2 = Goods marked in-store

3 = Pharmaceutical and medical supplies

– Five digits for the manufacturer number

– Five digits for the product number

5 = Coupons · One check digit

Page 144 of the Siemens 9014 user manual — Code 128 (EAN 128)
Pagina 144 · klik om te vergroten
Pagina 144

Code 128 (EAN 128) Barcodes

UPC-E

The UPC-E code is a compressed version of UPC-A with zero suppression in specific digit sequences. Suppression of four consecutive zeros begins from the sixth digit from the left. Zero suppression must be performed by the application.

012345000065 without zero suppression

01234565 with zero suppression

All digits except the system identifier and check character are printed in plain text.The symbol layout is self-checking.

A check digit is required. (Check digit calculation is performed modulo 10, with a weighting of 3, as in UPC-A, because UPC-E is a compressed form of UPC-A). The check digit must be programmed in the application. The check digit of the UPC-E symbol is calculated on the non-zero-suppressed digit sequence. The principle of check digit calculation is described in the section “EAN-8 and EAN-13”.

The code can be printed in the three sizes SC3, SC6 and SC9. The height of the symbol is variable but should be programmed to approximately match the width of the symbol.

The blank zone before and after the barcode symbol should be at least 0.1287 inch for SC3, at least 0.1755 inch for SC6, and at least 0.234 for SC9.

UPC-A and UPC-E Add-on

UPC-A and UPC-E with a two or five-digit add-on are printed automatically if two or five additional digits are programmed in the application.

The check digit calculation ignores the add-on digits.

Code 128 (EAN 128)

The Code 128 has a character set of 128 ASCII characters, four control characters (FNC1, FNC2, FNC3, FNC4) and four special characters (CODE A, CODE B, CODE C, SHIFT). The number of characters is variable. The three start characters, the stop character and the special characters are automatically generated by the printer to optimize the information density.

Example

Page 145 of the Siemens 9014 user manual — POSTNET
Pagina 145 · klik om te vergroten
Pagina 145

All printable ASCII characters are printed in the plain text line. All other characters, start, stop, control and special characters and the check digit are replaced by a space. The required check character is automatically generated by the printer. The symbol layout is self-checking.

If the barcode begins with FNC1 (hexadecimal 5D 43 31), this identifies EAN 128.

FNC2 (hexadecimal 5D 43 32) controls the reader for multiple reads.

FNC3 (hexadecimal 5D 43 33) is reserved for special reader functions.

FNC4 (hexadecimal 5D 43 34) is reserved for special future applications.

The barcode height should be 15% of the barcode length or 0.25 inch, whichever is greater.

Example of check digit calculation:

Plain text with check digit : 0 0 3 4 0 1 2 3 4 5 1 2 3 4 5 6 7 8 9 5

Plain text w/o check digit : 0 0 3 4 0 1 2 3 4 5 1 2 3 4 5 6 7 8 9

Weighting factors : 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3

Products0 0 9 4 0 1 6 3 1

2 5 3 2 9 4 1 5 6 2 1 8 2 7

Sum of products135
Modulo 10135 modulo 10 = 13, remainder 5
Check digit10 - 5 = 5
Check digit5

POSTNET

The POSTNET code has a character set of ten digits.

The number of characters is fixed and depends on the application:

5-Digit Zip Code (A Field) 5 digits plus check digit

Zip + 4 Code (C Field) 9 digits plus check digit

Delivery Point Barcode (C Prime Field) 11 digits plus check digit

The start/stop characters and the check digit are automatically generated by the printer (modulo 10 with a weighting of 1). This barcode has no plain text line.

POSTNET Barcodes

Page 146 of the Siemens 9014 user manual — Select barcode
Pagina 146 · klik om te vergroten
Pagina 146

The barcode is a fixed size. The length varies with the number of digits. The barcode pitch is 21.18 bars/inch, the bar is 0.021 inch nominal, and the gap is 0.0255 inch.

The print quality (LQ/NLQ/draft), which determines the print speed, can be programmed in the application using specific control characters.

Select barcode

The following specifications are required before barcode symbols can be printed:

– Barcode set selection

– Height and width of the bars and spaces

– Ratio of wide to narrow bars and spaces

– Barcode alignment (horizontal/vertical)

– Current print position after printing

– Plain text line (yes/no)

These specifications can be made at ay time. The information is retained until the printer is reset.

Normal text is not affected by these specifications. The line pitch set for normal text remains unchanged.

The line pitch is set to 1/12 inch for the barcode to be printed.

Control char. sequence Hexadecimal Decimal

ESC [ ; p2; p3 ; p4 ; p5 ; p6 ; p7 SP z

1B 5B 3B p2 3B p3 3B p4 3B p5 3B p6 3B p7 20 7A 27 91 59 p2 59 p3 59 p4 59 p5 59 p6 59 p7 32 122

Select barcode Barcodes

Page 147 of the Siemens 9014 user manual — 112 --- --- --- POSTNET
Pagina 147 · klik om te vergroten
Pagina 147

p2 Specification of the barcode set whose characters are to be printed.

Values:

Vertical barcode without plain

Vertical barcode with plain text

barcode with plain text

101 201 301 401 Code 39

102 202 302 402 2 out of 5 Industrial

103 203 303 403 2 out of 5 Inter- leaved

104 204 304 404 Codabar

105 205 --- --- EAN 8

106 206 --- --- EAN 13

107 207 307 407 Code 93

108 208 308 408 MSI Mod 10/10

109 209 --- --- UPC E

110 210 --- --- UPC A

111 211 311 411 Code 128

112 --- --- --- POSTNET

Show 7 more labels / short text on this page
Select barcode Barcodes · Horizontal · Horizontal · Barcode set · barcode without plain · text · text
Page 148 of the Siemens 9014 user manual — !
Pagina 148 · klik om te vergroten
Pagina 148

p3 Specification of bar height; bar height = p3 x 1/12 inch. A decimal whole number with one or two digits (from 1 to 99) can be specified.

EAN and UPC codes with add-on code (EAN Add-On 2 or EAN Add-On 5) require a minimum height of 3/12 inch.

!

Value of decimal place

p4 Width of bar

p5 Width of space

p6 Ratio of wide to narrow

Code direction horizontal vertical

Code direction horizontal vertical

0 0.35 mm 0.28 mm 0.35 mm 0.28 mm 2.0 to 1

1 0.53 mm 0.42 mm 0.53 mm 0.42 mm 2.5 to 1

2 0.70 mm 0.56 mm 0.70 mm 0.56 mm 3.0 to 1

3 0.88 mm 0.70 mm 0.88 mm 0.70 mm 3.5 to 1

4 1.05 mm 0.85 mm 1.05 mm 0.85 mm ---

5 1.23 mm 0.99 mm 1.23 mm 0.99 mm ---

6 1.41 mm 1.12 mm 1.41 mm 1.12 mm ---

7 1.58 mm 1.27 mm 1.58 mm 1.27 mm ---

These values change with the degree of saturation of the ribbon. They are thus only valid for a new ribbon.

The module width is standardized with the EAN and UPC codes. The following values are valid for p6 when setting the barcode:

p6 = 0 p6 = 1 p6 = 2 p6 = 3

SizeSC 3 1)
SizeSC 6 1)
SizeSC 9 1)
SizeSC 3 1)
1. SC 3, SC 6 and SC 9 refer to the DIN standard.

The ratio of wide to narrow is fixed with Code 93, MSI Mod 10/10 and Code 128. p6 is thus not required and is ignored. POSTNET does not require the parameters p4, p5 and p6.

Select barcode Barcodes

Page 149 of the Siemens 9014 user manual — !
Pagina 149 · klik om te vergroten
Pagina 149

p7 Define the print direction (uni- or bi-directional)

p7 = 0 p7 = 1 p7 = 2 p7 = 3 p7 = 4

uni-directional printing (standard) uni-directional printing in LQ bi-directional printing in LQ uni-directional printing in NLQ bi-directional printing in NLQ

!

If p7 is not defined, the standard value (uni-directional) is valid.

The parameter UNI-DIRECT.CMD needs to be set via operator panel or ESC-sequence whenever a switch between uni-directional and bi-directio- nal printing is intended.

In the following examples the parameter p7 is not used. So the printing direction is uni-direc- tional.

Barcodes

Page 150 of the Siemens 9014 user manual — Programming examples
Pagina 150 · klik om te vergroten
Pagina 150

Set/reset barcode mode Barcodes

Set/reset barcode mode

Siemens 9014 — Set/reset barcode mode diagram (page 150)
Afb. 13 · Set/reset barcode mode

Set ESC [ ? 0 h 1B 5B 3F 30 68 27 91 63 48 104

Reset ESC [ ? 0 l1) 1B 5B 3F 30 6C 27 91 63 48 108

1. This letter is a small „L“!

The printing of barcode symbols is set or reset with this control character.

The barcode must be selected before the barcode mode is activated. While the barcode mode is on, no other escape sequences are permitted. No page break is allowed within a barcode symbol!

Programming examples

Programming:

: ESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z

ExampleESC [ ; 201 ; 8 ; 1 ; 1 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Programming examples diagram (page 150)
Afb. 14 · Programming examples

Code 39 · Barcode header header

Page 151 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 151 · klik om te vergroten
Pagina 151

2 out of 5 Industrial

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 202 ; 8 ; 1 ; 1 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data: 1 2 3 4 5 6 7 8 9 0 ;
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 151)
Afb. 15 · Set/reset barcode mode

: 1 2 3 4 5 6 6 7 8 9 0 ;

2 out of 5 Interleaved

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 203 ; 8 ; 1 ; 1 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data: 1 2 3 4 5 6 7 8 9 0 ;
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 151)
Afb. 16 · Set/reset barcode mode

: 1 2 3 4 5 6 7 8 9 0 ;

Programming examples Barcodes

Page 152 of the Siemens 9014 user manual — EAN-8
Pagina 152 · klik om te vergroten
Pagina 152

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 204 ; 8 ; 1 ; 1 ; 1 SP z
Set barcode modeESC [ ? 0 h
Dataa 0 1 2 3 4 5 6 7 8 9 0 t
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 152)
Afb. 17 · Set/reset barcode mode

a 0 1 2 3 4 5 6 6 7 8 9 t

EAN-8

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 205 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data4 0 1 2 3 4 5 5
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — EAN-8 diagram (page 152)
Afb. 18

Programming examples Barcodes · Codabar (Monarch)

Page 153 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 153 · klik om te vergroten
Pagina 153

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 205 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data4 0 1 2 3 4 5 5 1 2
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 153)
Afb. 19 · Set/reset barcode mode

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 205 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data4 0 1 2 3 4 5 5 8 6 1 0 4
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 153)
Afb. 20 · Set/reset barcode mode

Programming examples Barcodes · EAN-8 Add-on 2 · EAN-8 Add-on 5

Page 154 of the Siemens 9014 user manual — EAN-13
Pagina 154 · klik om te vergroten
Pagina 154

EAN-13

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 206 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data4 1 2 3 4 5 6 7 8 9 0 1 8
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — EAN-13 diagram (page 154)
Afb. 21

4 1 2 3 4 5 6 7 8 9 0 1 8

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 206 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h

Data : 4 1 2 3 4 5 6 7 8 9 0 1 8 1 2

Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — EAN-13 diagram (page 154)
Afb. 22

4 1 2 3 4 5 6 7 8 9 0 1 8

Programming examples Barcodes · EAN-13 Add-on 2

Page 155 of the Siemens 9014 user manual — C + 0 + D + E 9 3 W I
Pagina 155 · klik om te vergroten
Pagina 155

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 206 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h

Data : 4 1 2 3 4 5 6 7 8 9 0 1 8 8 6 1 0 4

Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!
Siemens 9014 — Set/reset barcode mode diagram (page 155)
Afb. 23 · Set/reset barcode mode

4 1 2 3 4 5 6 7 8 9 0 1 8

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 207 ; 8 ; 1 ; 1 ; SP z
Set barcode modeESC [ ? 0 h
Dataa C + O + D + E 9 3 W I e
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 155)
Afb. 24 · Set/reset barcode mode

C + 0 + D + E 9 3 W I

Programming examples Barcodes · EAN-13 Add-on 5 · Code 93

Page 156 of the Siemens 9014 user manual — UPC-E
Pagina 156 · klik om te vergroten
Pagina 156

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 208 ; 8 ; 1 ; 1 ; SP z
Set barcode modeESC [ ? 0 h
Data: 1 2 3 4 5 6 7 4 1 ;
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 156)
Afb. 25 · Set/reset barcode mode

: 1 2 3 4 5 6 7 4 1 ;

UPC-E

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 209 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data0 1 2 3 4 5 6 5
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — UPC-E diagram (page 156)
Afb. 26

Programming examples Barcodes · MSI Mod 10/10

Page 157 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 157 · klik om te vergroten
Pagina 157

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 209 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data0 1 2 3 4 5 6 5 1 2
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 157)
Afb. 27 · Set/reset barcode mode

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 209 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data0 1 2 3 4 5 6 5 8 6 1 0 4
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 157)
Afb. 28 · Set/reset barcode mode

Programming examples Barcodes · UPC-E Add-on 2 · UPC-E Add-on 5

Page 158 of the Siemens 9014 user manual — UPC-A
Pagina 158 · klik om te vergroten
Pagina 158

UPC-A

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 210 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data0 1 2 3 4 5 6 7 8 9 0 5
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — UPC-A diagram (page 158)
Afb. 29

1 2 3 4 5 6 7 8 9 0

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 210 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h
Data0 1 2 3 4 5 6 7 8 9 0 5 1 2
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — UPC-A diagram (page 158)
Afb. 30

1 2 3 4 5 6 7 8 9 0

Programming examples Barcodes · UPC-A Add-on 2

Page 159 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 159 · klik om te vergroten
Pagina 159

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 210 ; 8 ; ; ; 1 SP z
Set barcode modeESC [ ? 0 h

Data : 0 1 2 3 4 5 6 7 8 9 0 5 8 6 1 0 4

Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 159)
Afb. 31 · Set/reset barcode mode

1 2 3 4 5 6 7 8 9 0

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 211 ; 8 ; 1 ; 1 ; SP z
Set barcode modeESC [ ? 0 h
DataCode 128
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 159)
Afb. 32 · Set/reset barcode mode

Programming examples Barcodes · UPC-A Add-on 5 · Code 128

Page 160 of the Siemens 9014 user manual — POSTNET
Pagina 160 · klik om te vergroten
Pagina 160

EAN 128

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 211 ; 8 ; 1 ; 1 ; SP z
Set barcode modeESC [ ? 0 h
Data]C100340123451234567895 (FNC = ]C1)
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — EAN 128 diagram (page 160)
Afb. 33

0 0 3 4 0 1 2 3 4 5 1 2 3 4 5 6 7 8 9 5

POSTNET

Programming with DPBC (delivery point barcode):

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 112 ; ; ; ; SP z
Set barcode modeESC [ ? 0 h
Data1 2 3 4 5 6 7 8 9 0 1
Reset barcode modeESC [ ? 0 l 1)
DataCR LF LF

Mark Pollan CR LF 101 Main St CR LF Anytown US 12345-6789

1. This letter is a small “L”!

Printout:

Programming examples Barcodes

Page 161 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 161 · klik om te vergroten
Pagina 161

The following examples use blank zones before and after the barcode symbol. The size of the blank zones is barcode-specific. The minimum sizes must be observed and must be provided by the application by positioning control functions before and after the barcode symbol.

Two horizontal barcode symbols side by side

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 201 ; 7 ; 0 ; 0 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
Blank zoneSP SP SP
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 161)
Afb. 34 · Set/reset barcode mode

* C O D E 3 9 * * C O D E 3 9 *

Programming examples Barcodes

Page 162 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 162 · klik om te vergroten
Pagina 162

Two horizontal barcode symbols one beneath the other

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 201 ; 7 ; 0 ; 0 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
Specify spacingCR LF LF LF LF LF LF LF
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 162)
Afb. 35 · Set/reset barcode mode

Programming examples Barcodes

Page 163 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 163 · klik om te vergroten
Pagina 163

Two vertical barcode symbols side by side

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 401 ; 7 ; 0 ; 0 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [? 0 l 1)
Horizontal positionSP SP SP
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 163)
Afb. 36 · Set/reset barcode mode

Programming examples Barcodes

Page 164 of the Siemens 9014 user manual — Set/reset barcode mode
Pagina 164 · klik om te vergroten
Pagina 164

Two vertical barcode symbols one beneath the other

Programming:

Barcode headerESC [ ; n2 ; n3 ; n4 ; n5 ; n6 SP z
ExampleESC [ ; 401 ; 7 ; 0 ; 0 ; 1 SP z
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
Specify spacingCR LF LF LF LF LF LF LF LF LF LF LF LF
Set barcode modeESC [ ? 0 h
Data* CODE 39 *
Reset barcode modeESC [ ? 0 l 1)
1. This letter is a small “L”!

Printout:

Siemens 9014 — Set/reset barcode mode diagram (page 164)
Afb. 37 · Set/reset barcode mode

* C O D E 3 9 * * C O D E 3 9 *

Programming examples Barcodes

Page 165 of the Siemens 9014 user manual — Format of the 13-digit standard EAN number
Pagina 165 · klik om te vergroten
Pagina 165

Format of EAN number Barcodes

Format of the 13-digit standard EAN number

Example of the format of an EAN number (European Article Numbering)

4 0 1 2 3 4 5 2 0 3 7 5 2

Item and packing unit

Check digit generation in the above example:

1. Addition of the numbers in the odd positions 4 + 1 + 3 + 5 + 0 + 7 = 20
2. Addition of the numbers in the even positions 0 + 2 + 4 + 2 + 3 + 5 = 16
3. Multiplication by 3 of the sum in 2) 16 x 3 = 48
4. Addition of the results of 1) and 3) 48 + 20 = 68
5. Modulo 10 check digit (difference from the nearest multiple of 10) 70 - 68 = 2
Show 12 more labels / short text on this page
Country · Standard company · Manufacturer’s · Check digit · code · number (bbn) · article number · FRG coorganization · Company name · 99% reliability · center · and address
Page 166 of the Siemens 9014 user manual — Forms transport mechanisms
Pagina 166 · klik om te vergroten
Pagina 166

Command overview of the IBM Proprinter emulation

Forms transport mechanisms

Decimal Remark See page

Eject sheet ESC [ < s 1B 5B 3C 73 27 91 60 115 17

Select paper source and ejection, number of copies, cut- off mode

ESC [ > p1 ; p2 ; p3 ; p4 s

1B 5B 3E p1 3B p2 3B p3 3B p4 73

27 91 62 p1 59 p2 59 p3 59 p4 115

Command Control sequence · Hexa- decimal

Page 167 of the Siemens 9014 user manual — ESC ; 1B 3B 27 59 24
Pagina 167 · klik om te vergroten
Pagina 167

Forms layout IBM Proprinter emulation

Forms layout

Decimal Remark See page

Set form length in lines

ESC C p1 1B 43 p1 27 67 p1 X’ 01 ≤ p1 ≤ X’ 7F 22

Set form length in inches

ESC C NUL p1

1B 00 43 p1

27 00 67 p1

X’ 01 ≤ p1 ≤ X’ 16 23

Set perfo- ration skip mode

ESC N p1 1B 4E p1 27 78 p1 X’ 00 ≤ p1 ≤ X’ FF in lines

Reset perfo- ration skip mode

ESC O 1B 4F 27 79 24

Set first print line

ESC 4 1B 34 27 52 First print line corresponds to top of form

ESC ; 1B 3B 27 59 24

Set left and right margins

ESC X p1 p2

1B 58 p1 p2

27 88 p1 p2

p1 p2

Left margin Right margin

Show 4 more labels / short text on this page
Command Control sequence · Hexa- decimal · Set left margin · in columns
Page 168 of the Siemens 9014 user manual — VT 0B 11 30
Pagina 168 · klik om te vergroten
Pagina 168

Forms transport IBM Proprinter emulation

Forms transport

Decimal Remark See page

Set 8 lpi ESC 0 1B 30 27 48 26

Set 7/72 inch line spacing mode

ESC 1 1B 31 27 49 26

Preset n/72 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1 X’ 01 ≤ p1 ≤ X’ 55 27

Set preset line spacing

ESC 2 1B 32 27 50 27

Set n/216 or n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1 X’ 01 ≤ p1 ≤ X’ FF 27

Set line spacing unit

ESC [ \ EOT NUL NUL NUL p1 NUL

1B 5B 5C 04 00 00 00 p1 00

27 91 92 04 00 00 00 p1 00

p1 Line spacing unit

Line feed (LF) LF 0A 10 28

ESC M 1B 4D 27 77 29

FF 0C 12 29

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1 X’ 00 ≤ p1 ≤ X’ FF in 1/216 inch or in 1/180 inch increments

Set vertical tab stops

ESC B p1 ... pk NUL

1B 42 p1 ... pk 00

27 66 p1 ... pk 00

VT 0B 11 30

Show 5 more labels / short text on this page
Command Control sequence · Hexa- decimal · Reverse line feed · Form feed (FF) · Vertical tabulation
Page 169 of the Siemens 9014 user manual — Forms transport
Pagina 169 · klik om te vergroten
Pagina 169

Forms transport IBM Proprinter emulation

Decimal Remark See page

Additional commands:

ESC [ p1 { 1B 5B p1 7B 27 91 p1 123

Reset tab stop ESC [ p1g 1B 5B p1 67 27 91 p1 103 31

Command Control sequence · Hexa- decimal · Load line spacing

Page 170 of the Siemens 9014 user manual — HT 09 09 37
Pagina 170 · klik om te vergroten
Pagina 170

Print carriage movements IBM Proprinter emulation

Print carriage movements

Command Control character sequence

Decimal Remark See page

CR 0D 13 32

Print head to left margin

ESC < 1B 3C 27 60 33

Space SP 20 32 33

Backspace BS 08 08 33

Set 10 cpi (Pica)

DC2 12 18 33

Set 12 cpi (Elite)

ESC : 1B 3A 27 58 34

Set 17.1 cpi SI 0F 16 34

Set/reset proportional spacing mode

ESC P p1 1B 50 p1 27 80 p1 p1 = p1 =

X’ 00, X’ 30 Fixed X’ 01, X’ 31 Proportional

ESC d p1 p2

1B 64 p1 p2

27 100 p1 p2

1/120inch increments 35

Set horizontal tab stops

ESC D p1 ... pk NUL

1B 44 p1 ... pk 00

27 68 p1 ... pk 00

HT 09 09 37

Set print direction (bidirectional or unidirec- tional)

ESC U p1 1B 55 p1 27 85 p1 p1 =

X’ 00, X’ 30 Bidirectional X’ 01, X’ 31 Unidirectional

Show 5 more labels / short text on this page
Hexa- decimal · Carriage return · Relative horizontal tabulation · Horizontal tabulation · p1 =
Page 171 of the Siemens 9014 user manual — Print carriage movements
Pagina 171 · klik om te vergroten
Pagina 171

Print carriage movements IBM Proprinter emulation

Command Control character sequence

Decimal Remark See page

Additional commands:

ESC [ p1 ‘ 1B 5B p1 60 27 91 p1 96

ESC [ p1 a 1B 5B p1 61 27 91 p1 97 38

ESC [ p1 d 1B 5B p1 64 27 91 p1 100 38

ESC [ p1 e 1B 5B p1 65 27 91 p1 101 38

Show 5 more labels / short text on this page
Hexa- decimal · Absolute horizontal positioning · Relative horizontal positioning · Absolute vertical positioning · Relative vertical positioning
Page 172 of the Siemens 9014 user manual — DC4 14 20 42
Pagina 172 · klik om te vergroten
Pagina 172

Font design IBM Proprinter emulation

Font design

Command Control character sequence

Decimal Remark See page

Select IBM character set 1

ESC 7 1B 37 27 55 39

Select IBM character set 2

ESC 6 1B 36 27 54 40

ESC E 1B 45 27 69 40

ESC F 1B 46 27 70 40

Set double strike mode

ESC G 1B 47 27 71 40

Reset double strike mode

ESC H 1B 48 27 72 40

Set subscript/ superscript mode

ESC S p1 1B 53 p1 27 83 p1 p1 =

X’ 00, X’ 30 Superscript X’ 01, X’ 31 Subscript

Reset subscript/ superscript mode

ESC T 1B 54 27 84 41

Set expanded mode for one line

SO 0E 14 42

ESC SO 1B 0E 27 14

ESC W p1 1B 57 p1 27 87 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

DC4 14 20 42

Set character size and line spacing

ESC [ @ EOT NUL NUL NUL p1 p2

1B 5B 40 04 00 00 00 p1 p2

27 91 64 04 00 00 00 p1 p2

Line spacing and character width Character height

Show 9 more labels / short text on this page
Hexa- decimal · Set boldface mode · Reset boldface mode · p1 = · Set/reset expanded mode · p1 = · Reset expanded mode · p1 · p2
Page 173 of the Siemens 9014 user manual — DRAFT LQ/NLQ LQ/NLQ DRAFT LQ/NLQ DRAFT LQ/NLQ
Pagina 173 · klik om te vergroten
Pagina 173

Font design IBM Proprinter emulation

Command Control character sequence

Decimal Remark See page

Set print quality and character pitch

ESC I p1 1B 49 p1 27 73 p1 Valid values p1: 44

X’ 00 X’ 02 X’ 03 X’ 08 X’ 0A X’ 10 X’ 12

DRAFT LQ/NLQ LQ/NLQ DRAFT LQ/NLQ DRAFT LQ/NLQ

10 cpi 10 cpi prop. 12 cpi 12 cpi 17 cpi 17 cpi

ESC - p1 1B 2D p1 27 45 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

ESC _ p1 1B 5F p1 27 95 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

Additional commands:

ESC [ p1 m

1B 5 B p1 6D 27 91 p1 109

ESC [ p1 b 1B 5 B p1

62 27 91 p1 98 45

Graphical change of size

ESC [ p1; p2 SP B

1B 5 B p1 3B p2 20 42

27 91 p1 59 p2 32 66

Set national version and code page

ESC [ p1; p2 w

1B 5B p1 3B p2 77 27 91 p1 59 p2 119

ESC [ p1 w

1B 5B p1 77 27 91 p1 119 45

Set code page ESC [ ; p2 w

1B 5B 3B p2 77

27 91 59 p2 119

Set character pitch and select font

ESC [ p1 ; p2 x

1B 5B p1 3B p2 78 27 91 p1 59 p2 120

Show 8 more labels / short text on this page
Hexa- decimal · Set/reset underscore mode · p1 = · Set/reset overscore mode · p1 = · Set graphic settings · Character repetition · Set national version
Page 174 of the Siemens 9014 user manual — Font design
Pagina 174 · klik om te vergroten
Pagina 174

Font design IBM Proprinter emulation

Command Control character sequence

Decimal Remark See page

Select font ESC [ p1 x 1B 5B p1

78 1B 5B p1 78 51

Set print quality (NLQ, LQ)

ESC [ p1 SP X

1B 5B p1 20 58 27 91 p1 32 88 51

Hexa- decimal

Page 175 of the Siemens 9014 user manual — Bitmap graphics
Pagina 175 · klik om te vergroten
Pagina 175

Bitmap graphics IBM Proprinter emulation

Bitmap graphics

Decimal Remark See page

ESC * p1 p2 p3 data

1B 2A p1 p2 p3 data

27 42 p1 p2 p3 data

p1 p2 p3

Graphics mode Number of columns

Select single dot-density graphics mode

ESC K p1 p2 data

1B 4B p1 p2 data

27 75 p1 p2 data

p1 p2 Number of

Select double dot-density graphics mode

ESC L p1 p2 data

1B 4C p1 p2 data

27 76 p1 p2 data

p1 p2 Number of

Select double dot-density and double- speed graphics mode

ESC Y p1 p2 data

1B 59 p1 p2 data

27 89 p1 p2 data

p1 p2 Number of

Select quadruple dot-density graphics mode

ESC Z p1 p2 data

1B 5A p1 p2 data

27 90 p1 p2 data

p1 p2 Number of

Select graphics mode (expanded)

ESC [ g p1 p2 p3 data

1B 5B 67 p1 p2 p3 data

27 91 103 p1 p2 p3 data

p1 p2

Number of graphics data bytes + 1 Graphics mode

Show 8 more labels / short text on this page
Command Control sequence · Hexa- decimal · Select graphics mode · columns · columns · columns · columns · p3
Page 176 of the Siemens 9014 user manual — $$/ 24 24 2F 36 36 47 64
Pagina 176 · klik om te vergroten
Pagina 176

Miscellaneous commands IBM Proprinter emulation

Miscellaneous commands

Decimal Remark See page

Set default tab stops

ESC R 1B 52 27 82 61

Transparent print data for one character

ESC ^ p1 1B 5E p1 27 94 p1 p1 Character code

Transparent print data for several characters

ESC \ p1 p2

1B 5C p1 p2

27 92 p1 p2

No. = (p1+(p2*256) 62

ESC 5 p1 1B 35 p1 27 53 p1 p1 =

X’ 00, X’ 30 CR = CR X’ 01, X’ 31 CR = CR + LF

DC1 11 17 63

ESC Q # 1B 51 23 27 81 35 63

ESC Q $ 1B 51 24 27 81 36 63

CAN 18 24 63

DEL 7F 127 63

NUL function NUL 00 00 64

Additional commands:

$$ 24 24 36 36

$$/ 24 24 2F 36 36 47 64

Show 11 more labels / short text on this page
Command Control sequence · Hexa- decimal · Automatic line feed · p1 = · Set printer online · Set printer offline · Set printer offline · Clear line buffer · Delete character · Command replacement $$ · Command replacement $$/
Page 177 of the Siemens 9014 user manual — 1B 5B 3F 30 6C
Pagina 177 · klik om te vergroten
Pagina 177

Miscellaneous commands IBM Proprinter emulation

Decimal Remark See page

ESC [ p1 ; p2 SP r

1B 5B p1 3B p2 20 72

27 91 p1 59 p2 32 114

Set barcode ESC [ ; p2; p3 ; p4 ; p5 ; p6 SP z

1B 5B 3B p2 3B p3 3B p4 3B p5 3B p6 20 7A

27 91 59 p2 59 p3 59 p4 59 p5 59 p6 32 122

OnESC [ ? 0 h

1B 5B 3F 30 68

27 91 63 48 104

OffESC [ ? 0 l

1B 5B 3F 30 6C

27 91 63 48 108

Show 4 more labels / short text on this page
Command Control sequence · Hexa- decimal · Macro selection · Set/reset barcode
Page 178 of the Siemens 9014 user manual — Alternative graphics mode AGM
Pagina 178 · klik om te vergroten
Pagina 178

Alternative graphics mode AGM IBM Proprinter emulation

Alternative graphics mode AGM

Decimal Remark See page

Set n/60 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1 X’ 01 ≤ p1 ≤ X’ 55 65

Set n/216 or n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1 X’ 01 ≤ p1 ≤ X’ FF 65

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1 X’ 00 ≤ p1 ≤ X’ FF in 1/180 inch or in 1/216 inch increments

ESC * p1 p2 p3 data

1B 2A p1 p2 p3 data

27 42 p1 p2 p3 data

Graphics mode Number of columns

p2 p3

Show 4 more labels / short text on this page
Command Control sequence · Hexa- decimal · Select graphics mode · p1
Page 179 of the Siemens 9014 user manual — ESC @ 1B 40 27 64 72
Pagina 179 · klik om te vergroten
Pagina 179

Command overview of the Epson LQ-2550 emulation

Initial condition

Decimal Remark See page

Reset to initial condition

ESC @ 1B 40 27 64 72

Forms transport mechanism

Decimal Remark See page

Select single form feed

ESC EM p1 1B 19 p1 27 25 p1 Ignored 73

Eject sheet ESC [ < s 1B 5B 3C 73 27 91 60 115 74

Select paper source and ejection, number of copies, cut- off mode

ESC [ > p1 ; p2 ; p3 ; p4 s

1B 5B 3E p1 3B p2 3B p3 3B p4 73

27 91 62 p1 59 p2 59 p3 59 p4 115

Show 4 more labels / short text on this page
Command Control sequence · Hexa- decimal · Command Control sequence · Hexa- decimal
Page 180 of the Siemens 9014 user manual — ESC O 1B 4F 27 79 81
Pagina 180 · klik om te vergroten
Pagina 180

Forms layout Epson LQ-2550 emulation

Forms layout

Decimal Remark See page

Set form length in lines

ESC C p1 1B 43 p1 27 67 p1 X’ 01 ≤ p1 ≤ X’ 7F 79

Set form length in inches

ESC C NUL p1

1B 43 00 p1

27 67 00 p1

X’ 01 ≤ p1 ≤ X’ 16 80

Set perforation skip mode

ESC N p1 1B 4E p1 27 78 p1 X’ 01 ≤ p1 ≤ X’ 7F in lines

Reset perfo- ration skip mode

ESC O 1B 4F 27 79 81

Set left margin ESC l p1 1B 6C p1 27 108 p1 X’ 00 ≤ p1 ≤ X’ FC in columns

ESC Q p1 1B 51 p1 27 81 p1 X’ 04 ≤ p1 ≤ X’ FF in columns

Command Control sequence · Hexa- decimal · Set right margin

Page 181 of the Siemens 9014 user manual — Forms transport
Pagina 181 · klik om te vergroten
Pagina 181

Forms transport Epson LQ-2550 emulation

Forms transport

Decimal Remark See page

Set 8 lpi ESC 0 1B 30 27 48 82

Set 6 lpi ESC 2 1B 32 27 50 82

Set n/60 inch line spacing mode

ESC A p1 1B 41 p1 27 65 p1 X’ 00 ≤ p1 ≤ X’ 7F 83

Set n/180 inch line spacing mode

ESC 3 p1 1B 33 p1 27 51 p1 X’ 00 ≤ p1 ≤ X’ FF 83

Set n/360 inch line spacing mode

ESC + p1 1B 2B p1 27 43 p1 X’ 00 ≤ p1 ≤ X’ FF 84

Line feed LF 0A 10 84

Form feed FF 0C 12 84

Relative vertical tabulation forward

ESC J p1 1B 4A p1 27 74 p1 X’ 00 ≤ p1 ≤ X’ FF in 1/180 inch increments

Relative vertical tabulation reverse

ESC j p1 1B 6A p1 27 106 p1 X’ 00 ≤ p1 ≤ X’ FF in 1/180 inch increments

Select vertical tabulation channel

ESC / p1 1B 2F p1 27 47 p1 X’ 00 ≤ p1 ≤ X’ 07 85

Set vertical tab stops

ESC B p1 ... pk NUL

1B 42 p1 ... pk 00

27 66 p1 ... pk 00

Set vertical tab stops in channel

ESC b p1 p2 ... pk NUL

1B 62 p1 p2 ... pk 00

27 98 p1 p2 ... pk 00

Command Control sequence · Hexa- decimal

Page 182 of the Siemens 9014 user manual — VT 0B 11 88
Pagina 182 · klik om te vergroten
Pagina 182

Forms transport Epson LQ-2550 emulation

Decimal Remark See page

VT 0B 11 88

Command Control sequence · Hexa- decimal · Vertical tabulation

Page 183 of the Siemens 9014 user manual — HT 09 09 94
Pagina 183 · klik om te vergroten
Pagina 183

Print carriage movements Epson LQ-2550 emulation

Print carriage movements

Decimal Remark See page

CR 0D 13 89

Space SP 20 32 90

Backspace BS 08 08 90

Set 10 cpi (Pica)

ESC P 1B 50 27 80 90

Set 12 cpi (Elite)

ESC M 1B 4D 27 77 90

Set 15 cpi ESC g 1B 67 27 103 91

Set/reset proportional spacing mode

ESC p p1 1B 70 p1 27 112 p1 p1

X’ 00, X’ 30 Fixed X’ 01, X’ 30 Proportional

Set character spacing mode

ESC SP p1 1B 20 p1 27 32 p1 1/120

Inch incs. (DRAFT) Inch incs. (LQ/NLQ)

ESC $ p1 p2

1B 24 p1 p2

27 36 p1 p2

1/60 Inch increments

ESC \ p1 p2

1B 5C p1 p2

27 92 p1 p2

Inch incs. (DRAFT) Inch incs. (LQ/NLQ)

Set horizontal tab stops

ESC D p1 ... pk NUL

1B 44 p1 ... pk 00

27 68 p1 ... pk 00

HT 09 09 94

Set print direction (bidirectional or unidirec- tional

ESC U p1 1B 55 p1 27 85 p1 p1 =

X’ 00, X’ 30 Bidirectional X’ 01, X’ 31 Unidirectional

Show 11 more labels / short text on this page
Command Control sequence · Hexa- decimal · Carriage return · p1 · 1/180 · Absolute horizontal tabulation · 1/120 · Relative horizontal tabulation · 1/180 · Horizontal tabulation · p1 =
Page 184 of the Siemens 9014 user manual — X’ 00 X’ 01 X’ 02 X’ 03
Pagina 184 · klik om te vergroten
Pagina 184

Print carriage movements Epson LQ-2550 emulation

Decimal Remark See page

Set unidirec- tional print mode for one line

ESC < 1B 3C 27 60 95

ESC a p1 1B 61 p1 27 97 p1 Valid values p1: 96

X’ 00 X’ 01 X’ 02 X’ 03

Left-justif. Centered Right-justif. Justified

Command Control sequence · Hexa- decimal · Select text alignment

Page 185 of the Siemens 9014 user manual — X' 00 X' 01 X' 02
Pagina 185 · klik om te vergroten
Pagina 185

Font design Epson LQ-2550 emulation

Font design

Decimal Remark See page

ESC k p1 1B 6B p1 27 107 p1 Valid values p1: 98

X’ 00 X’ 01 X’ 02 X’ 03 X’ 04 X’ 05 X’ 06 X’ 07 X’ 08 X’ 10

Roman Sans Serif Courier Prestige Script OCR-B OCR-A Orator-C Orator Data-Block

ESC R p1 1B 52 p1 27 82 p1 99

ESC t p1 1B 74 p1 27 116 p1 Valid values p1: 100

X' 00 X' 01 X' 02

Epson ITALIC Epson EXT GCT User-def. character set

Set/reset user-defined character set

ESC % p1 1B 25 p1 27 37 p1 p1 =

X' 01 Set X' 00 Reset

Copy current character set into user- defined character set

ESCNUL p 1 NUL

1B 3A 00 p1 00

27 58 00 p1 00

Valid values p 1101

X' 00 X' 01 X' 02 X' 03 X' 04 X' 05 X' 06 X' 07 X' 08 X’ 10

Roman Sans Serif Courier Prestige Script OCR-B OCR-A Orator-C Orator Data-Block

Show 6 more labels / short text on this page
Command Control sequence · Hexa- decimal · Select font · Select national version · Select character set · p1 =
Page 186 of the Siemens 9014 user manual — ESC H 1B 48 27 72 106
Pagina 186 · klik om te vergroten
Pagina 186

Font design Epson LQ-2550 emulation

Decimal Remark See page

ESC & NUL p1 p2 p3 p4 p5 data

1B 26 00 p1 p2 p3 p4 p5 data

27 38 00 p1 p2 p3 p4 p5 data

Code location First character Code location Last character Leading blank columns Number of dot columns Trailing blank columns Dot information

ESC x p1 1B 78 p1 27 120 p1 p1 =

X’ 00, X’ 30 DRAFT X’ 01, X’ 31 LQ/NLQ

ESC q p1 1B 71 p1 27 113 p1 Valid values p1: 105

X’ 00 X’ 01 X’ 02 X’ 03

Normal Outline Shadow Outline + shadow

ESC 4 1B 34 27 52 106

ESC 5 1B 35 27 53 106

ESC E 1B 45 27 69 106

ESC F 1B 46 27 70 106

Set double strike mode

ESC G 1B 47 27 71 106

Reset double strike mode

ESC H 1B 48 27 72 106

Show 16 more labels / short text on this page
Command Control sequence · Hexa- decimal · Define user- defined characters · p1 · p2 · p3 · p4 · p5 · data · Select print quality · p1 = · Select character style · Set italics mode · Reset italics mode · Set boldface mode · Reset boldface mode
Page 187 of the Siemens 9014 user manual — DC4 14 20 109
Pagina 187 · klik om te vergroten
Pagina 187

Font design Epson LQ-2550 emulation

Decimal Remark See page

Set subscript/ superscript mode

ESC S p1 1B 53 p1 27 83 p1 p1 =

X’ 00, X’ 30 Superscript X’ 01, X’ 31 Subscript

Reset subscript/ superscript mode

ESC T 1B 54 27 84 107

SI 0F 15 108

ESC SI 1B 0F 27 15

DC2 12 18 108

Set expanded mode for one line

SO 0E 14 108

ESC SO 1B 0E 27 14

ESC W p1 1B 57 p1 27 87 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

DC4 14 20 109

Set/reset double height mode

ESC w p1 1B 77 p1 27 119 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

Select print mode combi- nation

ESC ! p1 1B 21 p1 27 33 p1 110

ESC - p1 1B 2D p1 27 45 p1 p1 =

X’ 00, X’ 30 Reset X’ 01, X’ 31 Set

Show 11 more labels / short text on this page
Command Control sequence · Hexa- decimal · p1 = · Set condensed mode · Reset condensed mode · Set/reset expanded mode · p1 = · Reset expanded mode · p1 = · Set/reset underscore mode · p1 =
Page 188 of the Siemens 9014 user manual — Font design
Pagina 188 · klik om te vergroten
Pagina 188

Font design Epson LQ-2550 emulation

Decimal Remark See page

Set/reset line marking mode

ESC ( - ETX NUL SOH p1 p2

1B 28 2D 03 00 01 p1 p2

27 40 45 03 00 01 p1 p2

Additional commands:

Graphical change of sizes

ESC [ p1; p2 SP B

1B 5 B p1 3B p2 20 42

27 91 p1 59 p2 32 66

Set national version and code page

ESC [ p1; p2 w

1B 5B p1 3B p2 77 27 91 p1 59 p2 119 113

ESC [ p1 w 1B 5B p1

77 27 91 p1 119 113

ESC [ ; p2 w

1B 5B 3B p2 77

27 91 59 p2 119

Set character pitch and select font

ESC [ p1 ; p2 x

1B 5B p1 3B p2 78 27 91 p1 59 p2 120 115

Select font ESC [ p1 x 1B 5B p1 78 1B 5B p1 78 116

Set print quality (NLQ, LQ)

ESC [ p1 SP X

1B 5B p1 20 58 27 91 p1 32 88 116

Show 8 more labels / short text on this page
Command Control sequence · Hexa- decimal · p1 · Line position · p2 · Line type · Set national version · Set code page
Page 189 of the Siemens 9014 user manual — ESC > 1B 3E 27 62 122
Pagina 189 · klik om te vergroten
Pagina 189

Bitmap graphics Epson LQ-2550 emulation

Bitmap graphics

Decimal Remark See page

ESC * p1 p2 p3 data

1B 2A p1 p2 p3 data

27 42 p1 p2 p3 data

p1 p2 p3

Graphics mode Number of columns

ESC ? p1

1B 3F p1

27 63 p1

Graphics command Graphics mode

Miscellaneous commands

Decimal Remark See page

Control characters between X’ 80 and X’ 9F

ESC 7 1B 37 27 55 121

Printing characters between X’ 80 and X’ 9F

ESC 6 1B 36 27 54 121

Reset MSB to zero

ESC = 1B 3D 27 61 122

Set MSB to one

ESC > 1B 3E 27 62 122

ESC # 1B 23 27 35 122

DC1 11 17 123

Show 13 more labels / short text on this page
Command Control sequence · Hexa- decimal · Select graphics mode · Reassign graphics mode · p1 · p2 · p2 · p2 · p2 · Command Control sequence · Hexa- decimal · Delete MSB default · Set printer online
Page 190 of the Siemens 9014 user manual — 1B 5B 3F 30 6C
Pagina 190 · klik om te vergroten
Pagina 190

Miscellaneous commands Epson LQ-2550 emulation

Decimal Remark See page

DC3 13 19 123

CAN 18 24 123

DEL 7F 127 123

Audible signal BEL 07 07 124

NUL function NUL 00 00 124

Additional commands:

$$ 24 24 36 36

$$/ 24 24 2F 36 36 47 124

ESC [ p1 ; p2 SP r

1B 5B p1 3B p2 20 72 27 91 p1 59 p2 32 114

Set barcode ESC [ ; p2; p3 ; p4 ; p5 ; p6 SP z

1B 5B 3B p2 3B p3 3B p4 3B p5 3B p6 20 7A

27 91 59 p2 59 p3 59 p4 59 p5 59 p6 32 122

SetESC [ ? 0 h

1B 5B 3F 30 68

27 91 63 48 104

ResetESC [ ? 0 l

1B 5B 3F 30 6C

27 91 63 48 108

Show 9 more labels / short text on this page
Command Control sequence · Hexa- decimal · Set printer offline · Clear line buffer · Delete character · Command replacement $$ · Command replacement $$/ · Macro selection · Set/reset barcode
Page 191 of the Siemens 9014 user manual — ESC / P2 commands
Pagina 191 · klik om te vergroten
Pagina 191

Miscellaneous commands Epson LQ-2550 emulation

ESC / P2 commands

Dezimal Bemerkung Beschrei- bung Seite

ESC ( c p1 p2 p3 p4 p5

1B 28 63 p1 p2 p3 p4 p5

27 40 99 p1 p2 p3 p4 p5

Set page length in defi- ned units

ESC ( C p1 p2 p3

1B 28 43 p1 p2 p3

27 40 67 p1 p2 p3

Set absolute vertical print position

ESC ( V p1 p2 p3

1B 28 56 p1 p2 p3

27 40 86 p1 p2 p3

Relative verti- kale Druckpo- sition festlegen

ESC ( v p1 p2 p3

1B 28 76 p1 p2 p3

27 40 118 p1 p2 p3

Select font by pitch and point.

ESC X p1 p2 p3

1B 58 p1 p2 p3

27 88 p1 p2 p3

Set unit ESC ( U p1 p2

1B 28 55 p1 p2

27 40 85 p1 p2

Set horizontal Motion index(HMI)

ESC c p1 p2

1B 63 p1 p2 27 99 p1 p2 page 130

ESC ( t p1 p2 p3 p4

1B 28 74 p1 p2 p3 p4

27 40 116 p1 p2 p3 p4

ESC t p1 1B 74 p1 27 116 p1 page 131

Print data as characters

ESC ( ^ p1 p2 Daten

1B 28 5E p1 p2

27 40 94 p1, p2

ESC ( G p1 p2

1B 28 47 p1 p2

27 40 71 p1, p2

ESC . p1 p2 p3 p4 p5 p6

1B 2E p1 p2 p3 p4p5 p6

27 46 p1 p2 p3 p4p5 p6

Show 17 more labels / short text on this page
Befehl Steuer- zeichen- folge · Hexa- dezimal · Set page for- mat · page 127 · page 128 · page 128 · page 129 · page 129 · page 130 · Assign charac- ter table · page 131 · Select charac- ter table · page 132 · Select graphics mode · page 132 · Print raster graphics · page 133
Page 192 of the Siemens 9014 user manual — Ê
Pagina 192 · klik om te vergroten
Pagina 192

Character set tables

IBM all character set

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É á ░ ৒ ਈ α ≡

Ê

1 J ! 1 A Q a q ü æ í ▒ ০ ਄ ß ±

2 l ¤ " 2 B R b r é Æ ó ▓ Â ਅ Γ ≥

3 ♥ !! # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 ♠ _ & 6 F V f v å û ª Æ ৹ µ ÷

7 • ¤ ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 n ( 8 H X h x ê ÿ ¿ ৻ È Ø Φ ˚

9 † ) 9 I Y i y ë Ö ⌐ ਃ ৺ ৖ Θ •

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B F + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C C ’ < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D £ - = M ] m } ì ¥ ¡ ½ ৶ ▌ ø ²

E . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

Ê

F - / ? O _ o Å ƒ » ৎ ਇ ▀ ∩ SP

Ê

Show 4 more labels / short text on this page
¡ · ¡ · ¡ · ¬
Page 193 of the Siemens 9014 user manual — IBM set 1
Pagina 193 · klik om te vergroten
Pagina 193

IBM set 1 Character set tables

IBM set 1

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 NUL SP 0 @ P ‘ p NUL á ░ ৒ ਈ α ≡

1 DC1 ! 1 A Q a q DC1 í ▒ ০ ਄ ß ±

2 DC2 " 2 B R b r DC2 ó ▓ Â ਅ Γ ≥

3 DC3 # 3 C S c s DC3 ú ৆ Ã ৿ π ≤

4 DC4 $ 4 D T d t DC4 ñ ড়ৄ৾ ∑ ⌠

5 % 5 E U e u Ñ Å ৸ σ ⌡

6 & 6 F V f v ª Æ ৹ µ ÷

7 BEL ’ 7 G W g w BEL º ৼ Ç × τ ≈

8 BS CAN ( 8 H X h x BS CAN ¿ ৻ È Ø Φ ˚

9 HT ) 9 I Y i y HT ⌐ ਃ ৺ ৖ Θ •

A LF *J Z j z LF ¬ ৷ ਉ Ú Ω ·

B VT ESC + ; K [ k { VT ESC ½ ৽ ਆ █ δ √

C FF ' < L \ l | FF ¼ ¼ ਀ ▄ ∞ ⁿ

D CR - = M ] m } CR ¡ ½ ৶ ▌ ø ²

E SO . > N ^ n ~ SO « ¾ Î ▐ ε ■

F SI / ? O _ o SI » ৎ ਇ ▀ ∩ SP

Page 194 of the Siemens 9014 user manual — National versions of IBM set 1
Pagina 194 · klik om te vergroten
Pagina 194

IBM set 1 Character set tables

National versions of IBM set 1

23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E

1. USA # $ @ [ \ ] ^ ‘ { | } ~
2. FRANCE # $ à ° ç § ^ ‘ é ù è ¨
3. GERMANY # $ § Ä Ö Ü ^ ‘ ä ö ü ß
4. U.K. £ $ @ [ \ ] ^ ‘ { | } ~
5. DENMARK # $ @ Æ Ø Å ^ ‘ æ ø å ~
6. SWEDEN # ¤ É Ä Ö Å Ü é ä ö å ü
7. ITALY # $ @ ° \ é ^ ù à ò è ì
8. SPAIN P t $ @ ¡ Ñ ¿ ^ ` ¨ ñ } ~
9. JAPAN # $ @ [ ¥ ] ^ ` { | } ~
10. NORWAY # ¤ É Æ Ø Å Ü é æ ø å ü
11. DENMARK 2 # $ É Æ Ø Å Ü é æ ø å ü
12. SPAIN 2 # $ á ¡ Ñ ¿ é ` í ñ ó ú
13. LATIN AM. # $ á ¡ Ñ ¿ é Ü í ñ ó ú
14. TURKEY # i Ï Ç Ö Ü g ç ö ü

Character Code (Hex)

Page 195 of the Siemens 9014 user manual — IBM set 2
Pagina 195 · klik om te vergroten
Pagina 195

IBM set 2 Character set tables

IBM set 2

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 NUL SP 0 @ P ‘ p Ç É á ░ ৒ ਈ α ≡

1 DC1 ! 1 A Q a q ü æ í ▒ ০ ਄ ß ±

2 DC2 " 2 B R b r é Æ ó ▓ Â ਅ Γ ≥

3 ♥ DC3 # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ DC4 $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 ♠ & 6 F V f v å û ª Æ ৹ µ ÷

7 BEL ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 BS CAN ( 8 H X h x ê ÿ ¿ ৻ È Ø Φ ˚

9 HT ) 9 I Y i y ë Ö ⌐ ਃ ৺ ৖ Θ •

A LF *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B VT ESC + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C FF ’ < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D CR - = M ] m } ì ¥ ¡ ½ ৶ ▌ ø ²

E SO . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

F SI / ? O _ o Å ƒ » ৎ ਇ ▀ ∩ SP

Page 196 of the Siemens 9014 user manual — National versions of IBM set 2
Pagina 196 · klik om te vergroten
Pagina 196

IBM set 2 Character set tables

National versions of IBM set 2

Character Set Code (Hex)

23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E 9B 9D

1. USA # $ @ [ \ ] ^ ‘ { | } ~ ¢ ¥
2. FRANCE # $ à ° ç § ^ ‘ é ù è ¨ ¢ ¥
3. GERMANY # $ § Ä Ö Ü ^ ‘ ä ö ü ß ¢ ¥
4. U.K. £ $ @ [ \ ] ^ ‘ { | } ~ ¢ ¥
5. DENMARK # $ @ [ \ ] ^ ‘ { | } ~ ø Ø
6. SWEDEN # ¤ É Ä Ö Å Ü é ä ö å ü ¢ ¥
7. ITALY # $ @ ° \ é ^ ù à ò è ì ¢ ¥
8. SPAIN P t $ @ ¡ Ñ ¿ ^ ‘ ¨ ñ } ~ ¢ ¥
9. JAPAN # $ @ [ ¥ ] ^ ‘ { | } ~ ¢ ¥
10. NORWAY # $ @ [ \ ] ^ ‘‘ { | } ~ ø Ø
11. DEMARK 2 # $ @ [ \ ] ^ ‘ { | } ~ ø Ø
12. SPAIN 2 # $ á ¡ Ñ ¿ é ‘ í ñ ó ú ¢ ¥
13. LATIN AM. # $ á ¡ Ñ ¿ é Ü í ñ ó ú ¢ ¥
14. TURKEY # i Ï Ç Ö Ü g ç ö ü ¢ ¥
Page 197 of the Siemens 9014 user manual — Ê
Pagina 197 · klik om te vergroten
Pagina 197

IBM code pages Character set tables

IBM code pages

Page 437

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É á ░ ৒ ਈ α ≡

Ê

1 J ! 1 A Q a q ü æ í ▒ ০ ਄ ß ±

2 l ¤ " 2 B R b r é Æ ó ▓ Â ਅ Γ ≥

3 ♥ !! # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 ♠ _ & 6 F V f v å û ª Æ ৹ µ ÷

7 • ¤ ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 n ( 8 H X h x ê ÿ ¿ ৻ È Ø Φ ˚

9 † ) 9 I Y i y ë Ö ⌐ ਃ ৺ ৖ Θ •

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B F + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C C ' < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D £ - = M ] m } ì ¥ ¡ ½ ৶ ▌ ø ²

E . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

Ê

F - / ? O _ o Å ƒ » ৎ ਇ ▀ ∩ SP

Ê

¡ · ¡ · ¡ ¬

Page 198 of the Siemens 9014 user manual — Ê
Pagina 198 · klik om te vergroten
Pagina 198

IBM code pages Character set tables

Page 850

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É á ░ ৒ ð Ó -

Ê

1 J ! 1 A Q a q ü æ í ▒ ০ Ð ß ±

2 l ¤ " 2 B R b r é Æ ó ▓ Â Ê Ô =

3 ♥ !! # 3 C S c s â ô ú ৆ Ã Ë Ò ¾

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ È õ ¶

5 p § % 5 E U e u à ò Ñ Á Å ï Õ §

6 ♠ _ & 6 F V f v å û ª Â ã Ï µ ÷

7 • ¤ ’ 7 G W g w ç ù º À Ã Î þ ¸

8 n ( 8 H X h x ê ÿ ¿ © È Ï Þ

9 † ) 9 I Y i y ë Ö ® ਃ ৺ ৖ Ú ¨

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Û °

B F + ; K [ k { ï ø ½ ৽ ਆ █ Ù ¹

C C ' < L \ l | î £ ¼ ¼ ਀ ▄ ý ³

D £ - = M ] m } ì ∅ ¡ ¢ ৶ | Ý ²

E . > N ^ n ~ Ä x « ¥ Î ì ¯ ■

Ê

F - / ? O _ o Å ƒ » ৎ ¤ ▀ ' SP

Ê

Show 5 more labels / short text on this page
^ · ¡ · ¡ · ¡ · ¬
Page 199 of the Siemens 9014 user manual — Ê
Pagina 199 · klik om te vergroten
Pagina 199

IBM code pages Character set tables

Page 858

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É á ░ ৒ ð Ó -

Ê

1 J ! 1 A Q a q ü æ í ▒ ০ Ð ß ±

2 l ¤ " 2 B R b r é Æ ó ▓ Â Ê Ô =

3 ♥ !! # 3 C S c s â ô ú ৆ Ã Ë Ò ¾

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ È õ ¶

5 p § % 5 E U e u à ò Ñ Á Å Õ §

6 ♠ _ & 6 F V f v å û ª Â ã Ï µ ÷

7 • ¤ ’ 7 G W g w ç ù º À Ã Î þ ¸

8 n ( 8 H X h x ê ÿ ¿ © È Ï Þ

9 † ) 9 I Y i y ë Ö ® ਃ ৺ ৖ Ú ¨

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Û °

B F + ; K [ k { ï ø ½ ৽ ਆ █ Ù ¹

C C ' < L \ l | î £ ¼ ¼ ਀ ▄ ý ³

D £ - = M ] m } ì ∅ ¡ ¢ ৶ Ý ²

E . > N ^ n ~ Ä x « ¥ Î ì ¯ ■

Ê

F - / ? O _ o Å ƒ » ৎ ¤ ▀ ' SP

Ê

Show 5 more labels / short text on this page
^ · ¡ · ¡ · ¡ · ¬
Page 200 of the Siemens 9014 user manual — Ê
Pagina 200 · klik om te vergroten
Pagina 200

IBM code pages Character set tables

Page 860

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É á ░ ৒ ਈ α ≡

Ê

1 J ! 1 A Q a q ü À í ▒ ০ ਄ ß ±

2 l ¤ " 2 B R b r é È ó ▓ Â ਅ Γ ≥

3 ♥ !! # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 ♠ _ & 6 F V f v Á Ú ª Æ ৹ µ ÷

7 • ¤ ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 n ( 8 H X h x ê Ì ¿ ৻ È Ø Φ ˚

9 † ) 9 I Y i y Ê Õ Ò ਃ ৺ ৖ Θ •

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B F + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C C ' < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D £ - = M ] m } ì Ù ¡ ½ ৶ ▌ ø ²

E . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

Ê

F - / ? O _ o Å ó » ৎ ਇ ▀ ∩ SP

Ê

Show 4 more labels / short text on this page
¡ · ¡ · ¡ · ¬
Page 201 of the Siemens 9014 user manual — Ê
Pagina 201 · klik om te vergroten
Pagina 201

IBM code pages Character set tables

Page 863

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ‘ p Ç É ░ ৒ ਈ α ≡

Ê

1 J ! 1 A Q a q ü È ’ ▒ ০ ਄ ß ±

2 l ¤ " 2 B R b r é Ê ó ▓ Â ਅ Γ ≥

3 ♥ !! # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ ¶ $ 4 D T d t Â Ë ¨ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à Ï ¸ Å ৸ σ ⌡

6 ♠ _ & 6 F V f v ¶ û ³ Æ ৹ µ ÷

7 • ¤ ’ 7 G W g w ç ù ¯ ৼ Ç × τ ≈

8 n ( 8 H X h x ê ¤ Î ৻ È Ø Φ ˚

9 † ) 9 I Y i y ë Ô ⌐ ਃ ৺ ৖ Θ •

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B F + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C C ´ < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D £ - = M ] m } = Ù ¾ ½ ৶ ▌ ø ²

E . > N ^ n ~ À Û « ¾ Î ▐ ε ■

Ê

F - / ? O _ o § ƒ » ৎ ਇ ▀ ∩ SP

Ê

Show 4 more labels / short text on this page
¡ · ¡ · ¡ · ¬
Page 202 of the Siemens 9014 user manual — Ê
Pagina 202 · klik om te vergroten
Pagina 202

IBM code pages Character set tables

Page 865

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 Ø SP 0 @ P ` p Ç É á ░ ৒ ਈ α ≡

Ê

1 J ! 1 A Q a q ü æ í ▒ ০ ਄ ß ±

2 l ¤ " 2 B R b r é Æ ó ▓ Â ਅ Γ ≥

3 ♥ !! # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 ♦ ¶ $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 p § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 ♠ _ & 6 F V f v å û ª Æ ৹ µ ÷

7 • ¤ ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 n ( 8 H X h x ê ÿ ¿ ৻ È Ø Φ ˚

9 † ) 9 I Y i y ë Ö ⌐ ਃ ৺ ৖ Θ •

A I ¡ *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B F + ; K [ k { ï ø ½ ৽ ਆ █ δ √

C C ' < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D £ - = M ] m } ì ∅ ¡ ½ ৶ ▌ ø ²

E . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

Ê

F - / ? O _ o Å ƒ ¤ ৎ ਇ ▀ ∩ SP

Ê

Show 5 more labels / short text on this page
¡ · ¡ · ¡ · ¡ · ¬
Page 203 of the Siemens 9014 user manual — Epson EXT GCT
Pagina 203 · klik om te vergroten
Pagina 203

Epson EXT GCT

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 SP 0 @ P ‘ p Ç É á ░ ৒ ਈ α ≡

1 ! 1 A Q a q ü æ í ▒ ০ ਄ ß ±

2 " 2 B R b r é Æ ó ▓ Â ਅ Γ ≥

3 # 3 C S c s â ô ú ৆ Ã ৿ π ≤

4 $ 4 D T d t ä ö ñ ড়ৄ৾ ∑ ⌠

5 § % 5 E U e u à ò Ñ Å ৸ σ ⌡

6 & 6 F V f v å û ª Æ ৹ µ ÷

7 ’ 7 G W g w ç ù º ৼ Ç × τ ≈

8 ( 8 H X h x ê ÿ ¿ ৻ È Ø Φ ˚

9. 9 I Y i y ë Ö ⌐ ਃ ৺ ৖ Θ •
A *J Z j z è Ü ¬ ৷ ਉ Ú Ω ·

B + ; K [ k { ï ¢ ½ ৽ ਆ █ δ √

C ' < L \ l | î £ ¼ ¼ ਀ ▄ ∞ ⁿ

D - = M ] m } ì ¥ ¡ ½ ৶ ▌ ø ²

E . > N ^ n ~ Ä Pt « ¾ Î ▐ ε ■

F / ? O _ o Å ƒ » ৎ ਇ ▀ ∩ SP

Character set tables

Page 204 of the Siemens 9014 user manual — National versions of Epson EXT GCT
Pagina 204 · klik om te vergroten
Pagina 204

Epson EXT GCT Character set tables

National versions of Epson EXT GCT

23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E

1. USA # $ @ [ \ ] ^ ‘ { | } ~
2. FRANCE # $ à ° ç § ^ ‘ é ù è ¨
3. GERMANY # $ § Ä Ö Ü ^ ‘ ä ö ü ß
4. U.K. £ $ @ [ \ ] ^ ‘ { | } ~
5. DENMARK # $ @ Æ Ø Å ^ ‘ æ ø å ~
6. SWEDEN # ¤ É Ä Ö Å Ü é ä ö å ü
7. ITALY # $ @ ° \ é ^ ù à ò è ì
8. SPAIN P t $ @ ¡ Ñ ¿ ^ ‘ ¨ ñ } ~
9. JAPAN # $ @ [ ¥ ] ^ ‘ { | } ~
10. NORWAY # ¤ É Æ Ø Å Ü é æ ø å ü
11. DENMARK 2 # $ É Æ Ø Å Ü é æ ø å ü
12. SPAIN 2 # $ á ¡ Ñ ¿ é ‘ í ñ ó ú
13. LATIN AM. # $ á ¡ Ñ ¿ é Ü í ñ ó ú
14. TURKEY # i Ï Ç Ö Ü g ç ö ü
15. LEGAL # $ § ° ' " ¶ ‘ © ® † ™

Character Code (Hex)

Page 205 of the Siemens 9014 user manual — Epson ITALIC
Pagina 205 · klik om te vergroten
Pagina 205

Epson ITALIC

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 SP 0 @ P ‘ p SP 0 @ P ‘ p

1 ! 1 A Q a q ! 1 A Q a q

2 " 2 B R b r " 2 B R b r

3 # 3 C S c s # 3 C S c s

4 $ 4 D T d t $ 4 D T d t

5 % 5 E U e u % 5 E U e u

6 & 6 F V f v & 6 F V f v

7 ’ 7 G W g w ’ 7 G W g w

8 ( 8 H X h x ( 8 H X h x

9. 9 I Y i y ) 9 I Y i y
A *J Z j z * : J Z j z

B + ; K [ k { + ; K [ k {

C ’ < L \ l | ' < L \ l |

D - = M ] m } - = M ] m }

E . > N ^ n ~ . > N ^ n ~

F / ? O _ o / ? O _ o

Character set tables

Page 206 of the Siemens 9014 user manual — National versions of Epson ITALIC (1)
Pagina 206 · klik om te vergroten
Pagina 206

Epson ITALIC Character set tables

National versions of Epson ITALIC (1)

23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E

1. USA # $ @ [ \ ] ^ ‘ { | } ~
2. FRANCE # $ à ° ç § ^ ‘ é ù è ¨
3. GERMANY # $ § Ä Ö Ü ^ ‘ ä ö ü ß
4. U.K. £ $ @ [ \ ] ^ ‘ { | } ~
5. DENMARK # $ @ Æ Ø Å ^ ‘ æ ø å ~
6. SWEDEN # ¤ É Ä Ö Å Ü é ä ö å ü
7. ITALY # $ @ ° \ é ^ ù à ò è ì
8. SPAIN P t $ @ ¡ Ñ ¿ ^ ‘ ¨ ñ } ~
9. JAPAN # $ @ [ Ø ] ^ ‘ { | } ~
10. NORWAY # ¤ É Æ Ø Å Ü é æ È å ü
11. DENMARK 2 # $ É Æ Ø Å Ü é æ È å ü
12. SPAIN 2 # $ á ¡ Ñ ¿ é ‘ í ñ ó ú
13. LATIN AM. # $ á ¡ Ñ ¿ é Ü í ñ ó ú
14. TURKEY # i Ï Ç Ö Ü g ç ö ü
15. LEGAL # $ § ° ' " ¶ ` © ® † ™

Character Code (Hex)

Page 207 of the Siemens 9014 user manual — National versions of Epson ITALIC (2)
Pagina 207 · klik om te vergroten
Pagina 207

Epson ITALIC Character set tables

National versions of Epson ITALIC (2)

A3 A4 C0 DB DC DD DE E0 FB FC FD FE

1. USA # $ @ [ \ ] ^ ‘ { | } ~
2. FRANCE # $ à ° ç § ^ ‘ é ù è ¨
3. GERMANY # $ § Ä Ö Ü ^ ‘ ä ö ü ß
4. U.K. £ $ @ [ \ ] ^ ‘ { | } ~
5. DENMARK # $ @ Æ Ø Å ^ ‘ æ Ý å ~
6. SWEDEN # ¤ É Ä Ö Å Ü é ä ö å ü
7. ITALY # $ @ ° \ é ^ ù à ò è ì
8. SPAIN P t $ @ ¡ Ñ ¿ ^ ‘ ¨ ñ } ~
9. JAPAN # $ @ [ Ø ] ^ ‘ { | } ~
10. NORWAY # ¤ É Æ Ø Å Ü é æ ø å ü
11. DENMARK 2 # $ É Æ Ø Å Ü é æ ø å ü
12. SPAIN 2 # $ á ¡ Ñ ¿ é ‘ í ñ ó ú
13. LATIN AM. # $ á ¡ Ñ ¿ é Ü í ñ ó ú
14. TURKEY # i Ï Ç Ö Ü g ç ö ü
15. LEGAL # $ § ° ’ " ¶ ‘ © ® † ™

Character Code (Hex)

Page 208 of the Siemens 9014 user manual — OCR-A
Pagina 208 · klik om te vergroten
Pagina 208

OCR-A Character set tables

OCR-A

0 1 2 3 4 5 6 7

0 NUL DLE SP 0 @ P p

1 SOH DC1 ! 1 A Q a q

2 STX DC2 " 2 B R b r

3 ETX DC3 # 3 C S c s

4 EOT DC4 $ 4 D T d t

5 ENQ NAK % 5 E U e u

6 ACK SYN & 6 F V f v

7 BEL ETB ’ 7 G W g w

8 BS CAN ( 8 H X h x

9 HT EM ) 9 I Y i y

A LF SUB *J Z j z

B VT ESC + ; K [ k {

C FF FS ¬ < L \ l |

D CR GR - = M ] m }

E SO RS . > N ^ n °

F SI US / ? O o █

Page 209 of the Siemens 9014 user manual — ISO 8859-1
Pagina 209 · klik om te vergroten
Pagina 209

ISO 8859-1 Character set tables

ISO 8859-1

Siemens 9014 — ISO 8859-1 diagram (page 209)
Afb. 38

0 1 2 3 4 5 6 7 8 9 A B C D E F

1 ! 1 A Q a q ¡ ± Á Ñ á ñ

2 " 2 B R b r ¢ ² Â Ò â ò

3 # 3 C S c s £ ³ Ã Ó ã ó

4 $ 4 D T d t Z Ä Ô ä ô

5 % 5 E U e u ¥ µ Å Õ å õ

6 ε 6 F V f v Š ¶ Æ Ö æ ö

7 ’ 7 G W g w § · Ç × ç ÷

8 ( 8 H X h x š z È Ø è ø

9. 9 I Y i y © ¹ É Ù é ù
A *J Z j z ª º Ê Ú ê ú

B + ; K [ k { « » Ë Û ë û

C , < L \ l | ¬ Œ Ì Ü ì ü

D - = M ] m } SHY œ Í Ý í ý

E . > N ^ n ~ ® Ÿ Î Þ î þ

F / ? O _ o ¯ ¿ Ï ß ï ÿ

Page 210 of the Siemens 9014 user manual — ISO 7-bit code (international version)
Pagina 210 · klik om te vergroten
Pagina 210

Code tables

ISO 7-bit code (international version)

0 1 2 3 4 5 6 7

0 NUL DLE SP 0 @ P ‘ p 0

1 SOH DC1 ! 1 A Q a q 1

2 STX DC2 " 2 B R b r 2

3 ETX DC3 # 3 C S c s 3

4 EOT DC4 $ 4 D T d t 4

5 ENQ NAK % 5 E U e u 5

6 ACK SYN & 6 F V f V 6

7 BEL ETB ’ 7 G W g w 7

8 BS CAN ( 8 H X h x 8

9 HT EM ) 9 I Y i y 9

A LF SUB *J Z j z A

B VT ESC + ; K [ k { B

C FF IS4 , < L \ l | C

D CR IS3 - = M ] m } D

E SO IS2 . > N ^ n ? E

F SI IS1 / ? O _ o DEL F

0 1 2 3 4 5 6 7

The letter A has the code 41 (ISO 7-bit code).

Example

Page 211 of the Siemens 9014 user manual — ISO 7-bit code (German national version)
Pagina 211 · klik om te vergroten
Pagina 211

ISO 7-bit code (German national version)

0 1 2 3 4 5 6 7

0 NUL DLE SP 0 $ P ‘ p 0

1 SOH DC1 ! 1 A Q a q 1

2 STX DC2 " 2 B R b r 2

3 ETX DC3 # 3 C S c s 3

4 EOT DC4 $ 4 D T d t 4

5 ENQ NAK % 5 E U e u 5

6 ACK SYN & 6 F V f V 6

7 BEL ETB ’ 7 G W g w 7

8 BS CAN ( 8 H X h x 8

9 HT EM ) 9 I Y i y 9

A LF SUB *J Z j z A

B VT ESC + ; K Ä k ä B

C FF IS4 , < L Ö l ö C

D CR IS3 - = M Ü m ü D

E SO IS2 . > N ^ n ß E

F SI IS1 / ? O _ o DEL F

0 1 2 3 4 5 6 7

The letter A has the code 41 (ISO 7-bit code).

Code tables · Example

Page 212 of the Siemens 9014 user manual — Meaning of the control characters in the code tables
Pagina 212 · klik om te vergroten
Pagina 212

Meaning of the control characters in the code tables

NUL Filler SOH Start of header STX Start of text ETX End of text EOT End of transmission ENQ Enquiry ACK Positive acknowledgment BEL Audible alarm BS Backspace HT Horizontal tabulation LF Line feed VT Vertical tabulation FF Form feed CR Carriage return SO Shift out SI Shift in SP Space DLE Data link escape DC1 Device control character 1 DC2 Device control character 2 DC3 Device control character 3 DC4 Device control character 4 NAK Negative acknowledgment SYN Synchronize ETB End of transmission block CAN Cancel EM End of message (end mark) SUB Substitute ESC Escape IS4 Information separator 4 IS3 Information separator 3 IS2 Information separator 2 IS1 Information separator 1 DEL Delete

Code tables

Page 213 of the Siemens 9014 user manual — Hexadecimal -> decimal conversion and vice versa
Pagina 213 · klik om te vergroten
Pagina 213

Hexadecimal -> decimal conversion and vice versa

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 00 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 0

1 01 17 33 49 65 81 97 113 129 145 161 177 193 209 225 241 1

2 02 18 34 50 66 82 98 114 130 146 162 178 194 210 226 242 2

3 03 19 35 51 67 83 99 115 131 147 163 179 195 211 227 243 3

4 04 20 36 52 68 84 100 116 132 148 164 180 196 212 228 244 4

5 05 21 37 53 69 85 101 117 133 149 165 181 197 213 229 245 5

6 06 22 38 54 70 86 102 118 134 150 166 182 198 214 230 246 6

7 07 23 39 55 71 87 103 119 135 151 167 183 199 215 231 247 7

8 08 24 40 56 72 88 104 120 136 152 168 184 200 216 232 248 8

9 09 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249 9

A 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 250 A

B 11 27 43 59 75 91 107 123 139 155 171 187 203 219 235 251 B

C 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 252 C

D 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 253 D

E 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 254 E

F 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 255 F

0 1 2 3 4 5 6 7 8 9 A B C D E F

Code tables

Page 214 of the Siemens 9014 user manual — Serial V.24/RS-232 C interface
Pagina 214 · klik om te vergroten
Pagina 214

Interfaces

The following describes the two interfaces provided on the 90152-12 interface module.

Serial V.24/RS-232 C interface

General data:

– ProtocolsDTR, X-ON/X-OFF
– Transfer rate600, 1200, 2400, 4800, 9600, 19200 baud
– Parityeven, odd, none, ignored
– Character length7 bits, 8 bits
– Stop bitssend = 2 stop bits, receive = 1 stop bit
Page 215 of the Siemens 9014 user manual — AA BA BB CA CB CC AB CD
Pagina 215 · klik om te vergroten
Pagina 215

V.24/RS-232 C Interfaces

Designation Explanation Direction from/to printer Pin EIA DIN CCITT

1 2 3 4 5 6 7 20

AA BA BB CA CB CC AB CD

E1 D1 D2 S2 M2 M1 E2 S1.2

101 103 104 105 106 107 102 108.2

PG: Protective Ground TXD: Transmit Data RXD: Receive Data RTS: Request to Send CTS: Clear to Send DSR: Data Set Ready SG: Signal Ground DTR: Data Terminal Ready

Pin assignment

Page 216 of the Siemens 9014 user manual — AA BB AB CD
Pagina 216 · klik om te vergroten
Pagina 216

V.24/RS-232 C Interfaces

The following signal lines are used:

Designation Explanation Direction from/to printer Pin EIA DIN CCITT

1 3 7 20

AA BB AB CD

E1 D2 E2 S1.2

101 104 102 108.2

PGProtective Ground RXD: Receive Data SG: Signal Ground DTR: Data Terminal Ready x

The printer sets the DTR signal to ON (positive level) as soon as it is ready to receive data after power-on.

The printer sets the DTR signal to OFF when less than 256 bytes are free in the buffer or when the printer enters the Stop mode. Further data is stored until the printer buffer is completely full; any additional data is lost.

The DTR signal returns to ON when the printer exits from the Stop mode and at least 512 bytes are free in the printer buffer.

DTR protocol

Page 217 of the Siemens 9014 user manual — AA BA BB CB CC AB CD
Pagina 217 · klik om te vergroten
Pagina 217

V.24/RS-232 C Interfaces

The following signal lines are used:

Designation Explanation Direction from/to printer Pin EIA DIN CCITT

1 2 3 5 6 7 20

AA BA BB CB CC AB CD

E1 D1 D2 M2 M1 E2 S1.2

101 103 104 106 107 102 108.2

PG: Protective Ground TXD: Transmit Data RXD: Receive Data CTS: Clear to Send DSR: Data Set Ready SG: Signal Ground DTR: Data Terminal Ready

After power-on, the DTR signal and the RTS signal are set to ON (positive level). When the host sets the DSR and CTS signals to ON, the printer sends an X-ON signal to the host. The printer is then ready to receive.

The data flow is controlled with the control characters DC1 (X-ON) and DC3 (X-OFF). The printer sends the control character DC1 to the host when it is ready to receive.

Ready to receive means:

– 512 bytes free in the printer buffer

The printer sends the control character DC3 to the output system 255 bytes before “Printer buffer full”. If further data is sent to the printer after the control character, it sends a second DC3 to the printer 128 bytes before buffer overflow. The control characters are sent in the sequence DC1, DC3, DC1, DC3 etc. The only exception in the sequence is the second DC3 before buffer overflow.

X-ON/X-OFF protocol · – Power-on

Page 218 of the Siemens 9014 user manual — Parallel Centronics interface
Pagina 218 · klik om te vergroten
Pagina 218

Parallel Centronics interface

Explanation Direction from/to printer

1 STROBE When the signal is set to logical zero, the data byte DATA 1 - DATA 8 is stored in the printer buffer.

2 3 4 5 6 7 8 9

DATA 1 DATA 2 DATA 3 DATA 4 DATA 5 DATA 6 DATA 7 DATA 8

Data line LSB Data line Data line Data line Data line Data line Data line Data line MSB

x

10 ACKN The printer indicates that it has received a character or a control character and that it is ready to receive another character by setting this signal to zero.

11 BUSY The printer cannot accept further data when this signal is 1.

12 PE Is set to 1 under the following conditions: – No paper – Paper out – Paper jam

13 SELECT This signal is always one. It indicates that the printer is always online and ready.

31 INIT When this signal goes to zero, the ACKN signal of the printer is set to one.

32 FAULT This signal is always one. It only goes to zero when the printer is turned off.

Centronics Interfaces · Pin assignment · Pin Signal name

Page 219 of the Siemens 9014 user manual — Parallel Centronics interface
Pagina 219 · klik om te vergroten
Pagina 219

After power-on, the PE signal goes to zero. The SELECT signal and the FAULT signal become one.

The host sets the data lines (DATA 1 - DATA 8) according to the character to be transferred.

After a timeout of 0.5 microseconds the host sends a STROBE pulse with a length of at least 0.5 microseconds. The character is stored in the printer buffer and the printer sends a BUSY signal to the host. When the data byte is stored completely in the printer buffer, the printer sends a BUSY and an ACKN signal to the host.

The ACKN signal informs the host that a data byte has been received and that the printer is ready to receive another character.

When the printer buffer is full, the BUSY signal is not reset to stop the data stream from the host. The BUSY signal is reset only when at least 256 bytes are free in the printer buffer.

When the Stop button is pressed, the BUSY signal remains one and the ACKN signal is not sent.

If at least 256 bytes are free in the printer buffer, pressing the Start button causes the BUSY signal to be reset and an ACKN signal to be sent to the host.

Centronics Interfaces · Protocol description · Timing

Page 220 of the Siemens 9014 user manual — Parallel Centronics interface
Pagina 220 · klik om te vergroten
Pagina 220
Siemens 9014 — Parallel Centronics interface diagram (page 220)
Afb. 39 · Parallel Centronics interface
Figure 9Timing of the Centronics interface

Centronics Interfaces

Page 221 of the Siemens 9014 user manual — Use with two interfaces
Pagina 221 · klik om te vergroten
Pagina 221

Use with two interfaces Interfaces

Use with two interfaces

The “Both interfaces active” mode can be selected in the menu (see [2]).

In this mode the printer buffer is subdivided into two parts with 256 bytes each.

After power-on, both interfaces are ready to receive data.

If a byte is received first at the serial interface, the parallel interface is blocked by the BUSY signal. The serial interface is active and uses the set protocol.

If a byte is received first at the parallel interface, the serial interface is blocked by the DTR signal (DTR = OFF) or, depending on the protocol, by transmission of XOFF.

A maximum of 256 bytes can be received at the serial interface even though the parallel interface is active. All further bytes are lost except for the byte received last.

If the printer buffer of the serial interface is completely free and if no further data is received within 60 seconds, both interfaces are again available.

If the printer buffer of the parallel interface is completely free and if no further data is received within 60 seconds, the data of the printer buffer of the serial interface is processed and the serial interface is activated.

Page 222 of the Siemens 9014 user manual — Ordering manuals
Pagina 222 · klik om te vergroten
Pagina 222

Related publications

Ordering manuals

[1] 9015 Printer ECMA Emulation Programmer Reference Guide

Contents Description of the control characters of the ECMA emulation. Information on the operation of the printer with BS2000, SINIX and at workstations.

[2] 9015 Printer Operating Manual

Target group Users putting the printer in service

Contents Putting in service, error information, upkeep

Applications Placing in service

[3] 9016 Printer Operating Manual

Target group Users putting the printer in service

Contents Putting in service, error information, upkeep

Applications Placing in service

Target group Programmers

Page 223 of the Siemens 9014 user manual — Ordering manuals
Pagina 223 · klik om te vergroten
Pagina 223

[4] 9014 Printer ECMA-Emulation Programmer Reference Guide

Contents Description of the control characters of the ECMA emulation. Information on the operation of the printer with BS2000, SINIX and at workstations.Zielgruppe Programmierer

Ordering manuals

The manuals listed above can be ordered from your local Siemens branch.

Please apply to your local office for ordering the manuals.

Related publications · Target group Programmers

Page 224 of the Siemens 9014 user manual — Environmental protection
Pagina 224 · klik om te vergroten
Pagina 224

Environmental protection

Environmentally friendly product design and development

This product has been designed in accordance with the Siemens standard “environmentally friendly product design and development”.

This means that the designers have taken into account decisive criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.

This saves resources and thus reduces the harm done to the environment.

Devices that do not have to be switched on permanently should not be switched on until they are used and should be switched off during long breaks and on completion of work.

Please dispose of printer consumables and batteries in accordance with local government regulations.

Please avoid sticking your own labels on plastic housing parts wherever possible, since this makes it difficult to recycle them.

Take-back, recycling and disposal

For details on take-back and reuse of devices and consumables within Europe, contact your Siemens branch office/subsidiary or our recycling center in Paderborn:

Tel. +49 5251 8180-10 Fax. +49 5251 8180-15

Further information on environmental protection

The Siemens AG representative for environmental protection will be pleased to answer any further questions you may have concerning environmental protection.

Siemens AG Environmental Protection Werner von Siemens Straße 6 86159 Augsburg

Tel. +49 821 599-2999 Fax. +49 821 599-3440

Page 225 of the Siemens 9014 user manual — Inhoudsopgave
Pagina 225 · Inhoud
Inhoud

Inhoud

Titlep.1Prefacep.3Brief description of the printerp.39014 Needle Printerp.49015 Needle Printerp.59015 E Needle Printerp.69016 Needle Printerp.7Target groupp.8Summary of contentsp.8Notational conventionsp.9Technical data and printer optionsp.10Technical datap.12Character complementp.13Optionsp.13Connection options of the 901x-12 printersp.14Serial interface V.24 (RS-232 C)p.14Parallel Centronics interfacep.14Description of the IBM Proprinter emulationp.15Initial conditionp.16Forms transport mechanismp.17Additional commandsp.17Forms layoutp.22Set form length in linesp.22Set form length in inchesp.23Set perforation skip modep.23Reset perforation skip modep.24Set first print linep.24Set left marginp.24Set left and right marginsp.25Forms transportp.26Set 8 lpip.26Set 7/72 inch line spacing modep.26Preset n/72 inch line spacing modep.27Set preset line spacingp.27Set n/216 or n/180 inch line spacing modep.27Set line spacing unitp.28Line feed (LF)p.28Reverse line feedp.29Form feed (FF)p.29Relative vertical tabulation forwardp.29Set vertical tab stopsp.30Vertical tabulationp.30Additional commandsp.31Print carriage movementsp.32Carriage returnp.32Print head to left marginp.33Spacep.33Backspacep.33Set 10 cpip.33Set 12 cpip.34Set 17.1 cpip.34Set/reset proportional spacing modep.34Relative horizontal tabulationp.35Set horizontal tab stopsp.36Horizontal tabulationp.37Set print direction (bidirectional or unidirectional)p.37Additional commandsp.38Font designp.39Select IBM character set 1p.39Select IBM character set 2p.40Set boldface modep.40Reset boldface modep.40Set double strike modep.40Reset double strike modep.40Set subscript/superscript modep.41Reset subscript/superscript modep.41Set expanded mode for one linep.42Set/reset expanded modep.42Reset expanded modep.42Set character size and line spacingp.43Set print quality and character pitchp.44Set/reset underscore modep.44Set/reset overscore modep.45Additional commandsp.46Bitmap graphicsp.52Select graphics modep.52Select single dot-density graphics modep.55Select double dot-density graphics modep.55Select double dot-density and double-speed graphics modep.56Select quadruple dot-density graphics modep.57Select graphics mode (expanded)p.58Miscellaneous commandsp.61Set default tab stopsp.61Transparent print data for one characterp.61Transparent print data for several charactersp.62Automatic line feedp.62Set printer onlinep.63Set printer offlinep.63Clear line bufferp.63Delete characterp.63NUL functionp.64Additional commandsp.64Alternative graphics mode AGMp.65Set n/60 inch line spacing modep.65Set n/216 or n/180 inch line spacing modep.65Relative vertical tabulation forwardp.66Select graphics modep.67Description of the Epson LQ-2550 emulationp.70Initial conditionp.71Reset to initial conditionp.72Forms transport mechanismp.73Select single form feedp.73Additional commandsp.74Forms layoutp.79Set form length in linesp.79Set form length in inchesp.80Set perforation skip modep.80Reset perforation skip modep.81Set left marginp.81Set right marginp.81Forms transportp.82Set 8 lpip.82Set 6 lpip.82Set n/60 inch line spacing modep.83Set n/180 inch line spacing modep.83Set n/360 inch line spacing modep.84Line feed (LF)p.84Form feed (FF)p.84Relative vertical tabulation forwardp.85Relative vertical tabulation reversep.85Select vertical tabulation channelp.85Set vertical tab stopsp.86Set vertical tab stops in channelp.87Vertical tabulationp.88Print carriage movementsp.89Carriage returnp.89Spacep.90Backspacep.90Set 10 cpi (Pica)p.90Set 12 cpi (Elite)p.90Set 15 cpip.91Set/reset proportional spacing modep.91Set character spacing modep.92Absolute horizontal tabulationp.92Relative horizontal tabulationp.93Set horizontal tab stopsp.94Horizontal tabulationp.94Set print direction (bidirectional or unidirectional)p.95Set unidirectional print mode for one linep.95Select text alignmentp.96Font designp.97Select fontp.98Select national versionp.99Select character setp.100Set/reset user-defined character setp.100Copy current character set into user-defined character setp.101Define user-defined charactersp.102Select print qualityp.105Select character stylep.105Set italics modep.106Reset italics modep.106Set boldface modep.106Reset boldface modep.106Set double strike modep.106Reset double strike modep.106Set subscript/superscript modep.107Reset subscript/superscript modep.107Set condensed modep.108Reset condensed modep.108Set expanded mode for one linep.108Set/reset expanded modep.109Reset expanded modep.109Set/reset double height modep.109Select print mode combinationsp.110Set/reset underscore modep.110Set/reset line marking modep.111Additional commandsp.112Bitmap graphicsp.117Select graphics modep.117Reassign graphics modep.120Miscellaneous commandsp.121Control characters between X’80 and X’9Fp.121Printing characters between X’80 and X’9Fp.121Reset most significant bit (MSB) to zerop.122Set most significant bit (MSB) to onep.122Delete most significant bit (MSB) defaultp.122Set printer onlinep.123Set printer offlinep.123Clear line bufferp.123Delete characterp.123Audible signalp.124NUL functionp.124Additional commandsp.124ESC / P2 Commandsp.126Set page formatp.126Set page length in defined unitsp.127Set absolute vertical print positionp.127Set relative vertical print positionp.128Select font by pitch and pointp.128Set unitp.129Set horizontal motion index (HMI)p.129Assign character tablep.130Select character tablep.130Print data as charactersp.131Select graphics modep.131Print raster graphicsp.132Barcodesp.133General informationp.134Code 39p.1342 out of 5 Industrialp.1352 out of 5 Interleavedp.136Codabarp.137EAN-8 and EAN-13p.137EAN-8 and EAN-13 Add-onp.139Code 93p.139MSI Mod 10/10p.142UPC-A and UPC-Ep.143UPC-A and UPC-E Add-onp.144Code 128 (EAN 128)p.144POSTNETp.145Select barcodep.146Set/reset barcode modep.150Programming examplesp.150Format of the 13-digit standard EAN numberp.165Command overview of the IBM Proprinter emulationp.166Forms transport mechanismsp.166Forms layoutp.167Forms transportp.168Print carriage movementsp.170Font designp.172Bitmap graphicsp.175Miscellaneous commandsp.176Alternative graphics mode AGMp.178Command overview of the Epson LQ-2550 emulationp.179Initial conditionp.179Forms transport mechanismp.179Forms layoutp.180Forms transportp.181Print carriage movementsp.183Font designp.185Bitmap graphicsp.189Miscellaneous commandsp.189ESC / P2 commandsp.191Character set tablesp.192IBM all character setp.192IBM set 1p.193National versions of IBM set 1p.194IBM set 2p.195National versions of IBM set 2p.196IBM code pagesp.197Page 437p.197Page 850p.198Page 858p.199Page 860p.200Page 863p.201Page 865p.202Epson EXT GCTp.203National versions of Epson EXT GCTp.204Epson ITALICp.205National versions of Epson ITALIC (1)p.206National versions of Epson ITALIC (2)p.207OCR-Ap.208ISO 8859-1p.209Code tablesp.210ISO 7-bit code (international version)p.210ISO 7-bit code (German national version)p.211Meaning of the control characters in the code tablesp.212Hexadecimal -> decimal conversion and vice versap.213Interfacesp.214Serial V.24/RS-232 C interfacep.214Parallel Centronics interfacep.218Use with two interfacesp.221Related publicationsp.222Environmental protectionp.224Indexp.225
Page 226 of the Siemens 9014 user manual — Index
Pagina 226 · klik om te vergroten
Pagina 226

condensed mode (Epson LQ-2550) 108

transport mechanism (IBM Proprinter) 17

D define user-defined characters 102 delete character

G graphical change of sizes 47 graphics mode

Epson LQ-2550 123 IBM Proprinter 63 double height mode

double dot-density (IBM Proprinter) 55 double dot-density and double speed (IBM

Proprinter) 56 quadruple density (IBM Proprinter) 57 reassign (Epson LQ-2550) 120 select (Epson LQ-2550) 117 select (expanded) (IBM Proprinter) 58 select (IBM Proprinter) 52 single dot-density (IBM Proprinter) 55 single-dot density (IBM Proprinter) 55

reset (Epson LQ-2550) 109 set (Epson LQ-2550) 109 double strike

Epson LQ-2550 106 IBM Proprinter 40 DTR protocol 214

E eject sheet 74 Epson LQ-2550 emulation 70 ESC / P2-Befehle 126 expanded mode

H horizontal tab stops

Epson LQ-2550 94 horizontal tabulation

for one line (Epson LQ-2550) 108 for one line (IBM Proprinter) 42 reset (Epson LQ-2550) 109 reset (IBM Proprinter) 42, 43 set (Epson LQ-2550) 109 set (IBM Proprinter) 42

absolute (Epson LQ-2550) 92 cause (Epson LQ-2550) 94 cause (IBM Proprinter) 37 IBM Proprinter 36 relative (Epson LQ-2550) 93 relative (IBM Proprinter) 35

F first print line (IBM Proprinter) 24 font 13, 98 select (Epson LQ-2550) 98 font design

I IBM Proprinter emulation 15 initial condition

Epson LQ-2550 71 IBM Proprinter 16 interface 212 Centronics 216 module 10, 11 V.24/RS-232 C 212 ISO 7-bit code

Epson LQ-2550 97 IBM Proprinter 39 forms

layout (Epson LQ-2550) 79 layout (IBM Proprinter) 22 length in inches (Epson LQ-2550) 80 length in inches (IBM Proprinter) 23 length in lines (Epson LQ-2550) 79 length in lines (IBM Proprinter) 22 transport (Epson LQ-2550) 82 transport (IBM Proprinter) 26 transport mechanism (Epson LQ-2550) 73

international version 208 national version 209 italics (Epson LQ-2550) 106

Index

Page 227 of the Siemens 9014 user manual — Index
Pagina 227 · klik om te vergroten
Pagina 227

Epson LQ-2550 124 IBM Proprinter 64

Epson LQ-2550 81 IBM Proprinter 24, 25 line feed

automatic (IBM Proprinter) 62 Epson LQ-2550 84 IBM Proprinter 28 reverse (IBM Proprinter) 29 line marking mode (Epson LQ-2550) 111 line spacing

Epson LQ-2550 123 IBM Proprinter 63 online

Epson LQ-2550 123 IBM Proprinter 63 overscore (IBM Proprinter) 45

1/6 inch (Epson LQ-2550) 82 1/8 inch (Epson LQ-2550) 82 1/8 inch (IBM Proprinter) 26 7/72 inch (IBM Proprinter) 26 n/180 inch (Epson LQ-2550) 83 n/180 inch (IBM Proprinter AGM mode) 65 n/180 inch (IBM Proprinter) 27 n/216 inch (IBM Proprinter AGM mode) 65 n/216 inch (IBM Proprinter) 27 n/360 inch (Epson LQ-2550) 84 n/60 inch (Epson LQ-2550) 83 n/60 inch (IBM Proprinter AGM mode) 65 n/72 inch (IBM Proprinter) 27 line spacing unit (IBM Proprinter) 28 load line spacing 31

select source 17, 74 perforation

Epson LQ-2550 80 IBM Proprinter 23 reset skip mode 81 perforation area

Epson LQ-2550 80 IBM Proprinter 23 print carriage movements

Epson LQ-2550 89 IBM Proprinter 32 print direction

bidirectional (Epson LQ-2550) 95 bidirectional (IBM Proprinter) 37 unidirectional (Epson LQ-2550) 95 unidirectional (IBM Proprinter) 37 unidirectional for one line (Epson LQ-

M macro selection 64, 125 margin

Epson LQ-2550 81 IBM Proprinter 24, 25 micro-column

2550) 95 print head to left margin (IBM Proprinter) 33 print modes combination (Epson LQ-2550) 110 print quality

IBM Proprinter 44 select (Epson LQ-2550) 105 set 51, 116 printer buffer 12 printer options 13 printing rate 12 proportional spacing

delete default (Epson LQ-2550) 122 set to one (Epson LQ-2550) 122 set to zero (Epson LQ-2550) 122

N national version (Epson LQ-2550) 99 NUL function

Epson LQ-2550 91 IBM Proprinter 34

Show 6 more labels / short text on this page
Index · L left margin · O offline · P paper · width 12 micro-line · spacing 12 MSB
Page 228 of the Siemens 9014 user manual — X-ON/X-OFF 215
Pagina 228 · klik om te vergroten
Pagina 228

Epson LQ-2550 107 IBM Proprinter 41

X-ON/X-OFF 215

R relative horizontal positioning 38 relative horizontal tabulation

T technical data 12 text alignment

Epson LQ-2550 93 IBM Proprinter 35 relative vertical positioning 38 relative vertical tabulation

centered (Epson LQ-2550) 96 left-justified (Epson LQ-2550) 96 right-justified (Epson LQ-2550) 96 top of form

forward (Epson LQ-2550) 85 forward (IBM Proprinter AGM mode) 66 forward (IBM Proprinter) 29 reverse (Epson LQ-2550) 85 reset tab stop 31 reset tab stop (IBM Proprinter) 61 reset to initial condition (Epson LQ-2550) 72 right margin

Epson LQ-2550 79, 80 IBM Proprinter 22, 23, 24 transparent print data

one character (IBM Proprinter) 61 several characters (IBM Proprinter) 62

Epson LQ-2550 81 IBM Proprinter 25

Epson LQ-2550 110 IBM Proprinter 44

S select cut-off mode 17, 74 select font 49, 51, 115, 116 select number of copies 17, 74 set character pitch 49, 115 set code page 113 set graphic settings 46 set national version 48, 113 set user-defined character set (Epson LQ-

V vertical tab stops

Epson LQ-2550 86 IBM Proprinter 30 in channel (Epson LQ-2550) 87 vertical tabulation

cause (Epson LQ-2550) 88 cause (IBM Proprinter) 30 relative forward (Epson LQ-2550) 85 relative forward (IBM Proprinter AGM

mode) 66 relative forward (IBM Proprinter) 29 relative reverse (Epson LQ-2550) 85 vertical tabulation channel (Epson LQ-2550) 85

Epson LQ-2550 90 IBM Proprinter 33 spaced mode (Epson LQ-2550) 92 spacing

10 cpi (IBM Proprinter) 33 12 cpi (IBM Proprinter) 34 17.1 cpi (IBM Proprinter) 34 proportional (IBM Proprinter) 34 subscript

Epson LQ-2550 107 IBM Proprinter 41 superscript

Show 4 more labels / short text on this page
Index · protocol · U underscore · 2550) 100 space
Page 229 of the Siemens 9014 user manual — U26169-J-Z716-1-7600
Pagina 229 · klik om te vergroten
Pagina 229

Siemens AG User Documentation OEC XS QM 4 33094 Paderborn Germany

Siemens 9014 — Index diagram (page 229)
Afb. 40 · Index

Comments on 9014, 9015, 9015 E, 9016 Printer

Epson and IBM Proprinter Emulation

U26169-J-Z716-1-7600

!

Page 230 of the Siemens 9014 user manual — U26169-J-Z716-1-7600
Pagina 230 · klik om te vergroten
Pagina 230

Siemens AG Training Center, Consulting Service 81730 Munich Germany

Siemens 9014 — Index diagram (page 230)
Afb. 41 · Index

The Siemens Training Center offers consulting for in-service training, courses and self-tuition media on almost all aspects of information technology, either on your premises or at a Training Center near you. Write to us for information and course programs.

Please send me information/course programs on the following topics

U26169-J-Z716-1-7600

!

Vraag stellen over de Siemens 9014

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Siemens 9014

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Siemens 9014 handleiding-pdf

230 pagina's·2.3 MB·Printer·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…