Gebruiksaanwijzing /service van het product DP van de fabrikant Siemens
Ga naar pagina of 65
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Training M.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C This m anual was prepared for training purposes by Siemens AG for the project Siemens Automation Cooperates with Education (SCE).
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C PA GE 1 PREFA CE ...................................... .....
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C The fo llo.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 1 PREFA CE Regarding its content, Module E 11 is part of the instruction unit 'IT Co mmunication w ith SIM ATIC S7’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Hardware a.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 2 NOTES REGARDING THE USA GE OF CPU 315F-2 PN/DP The CPU 315F-2 PN/DP is a CPU that is shipped wit h 2 integrated interfaces.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 3 NOTES RE.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 4 RFID FUN.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5 STARTING UP A N RFID PROJECT W ITH CPU 315F-2 PN/DP AND RF180C Below, th e startup of an RF ID project is descr ibed.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.1 Setting Up a New Project 1. The c entral tool in S T EP 7 is the ’SIMA T IC Manag er’ , which w e call here with a doub le click .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 4. Highlight y our project and insert an ’Industrial Ethernet Subnet’ ( → RFID_RF180C → Insert → Subnet → Industrial Ethernet).
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.2 Configuring t he Hardware 6. W ith a doubl e click , open the configuration tool for the ’Hardware’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 8. From the hardware catalog, w e can now select all modules that are present in the actual rack and insert them in the configuration table.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 9. Next, we drag the ’CPU 315F-2 PN/DP’ to t he second slot.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Notes re.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 11. Next, we are dragging the i nput m odule for 16 inputs to the 4th slot.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 12. Now we d rag the output module for 16 outputs to the 5th slot.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 14.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C This is w hat the comp leted hardw are configuration w ith th e associated addresses looks like 19.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.4 Inserting UDT Blocks and FB45 De-archive the library " RFID_FB45_UDT_Blocks “ f rom the template directory and open i t.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C DB49 MDS Statu s Information In DB49, the MDS status Information is entered.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Save and.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C DB50 Reader Status Information The reader status inf orm ation is entered in DB50.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Data vie.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C DB47 Request Data Block The DB47 is set by means of the UDT 11 in DB45.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Data Vie.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C DB45 Reader Parameter Block Each MOBY channel (reader) needs its own param eters.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Entries in DB45 The base address f or the RF180C is 256 (refer to hardware), here to be entered at add ress 0.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Data view of DB45 starting with by te 34 (SLG = Reader) Save and close DB45 Note The inputs in the data block are entered as actual value.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.6 Programming a Restart or Warm Restart A restart of the MOBYIM (interface m odule) is carried out by setting the variable " init_run ".
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.7 FC11 Function f or a Command or Request Before starting a MOBY comm and with "command_start“ , we have to define it .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Enter Ne.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.8 Basics of Entries at Command Block FC11 The values for DB47 are specif ied by means of the input variables of FC11.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C was read.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C pause wi.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.9 Command String The user c onfigures the com m and string by storing a corres ponding number of UDT 21 one after the other in a DB.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.10 Basics of FB45 and DB45 FB45 accesses DB45. In DB45, a UDT11 is em bedded for each r eader.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Input Parameters of the UDT 11 The user has to enter these variables during configuration (exception: com m and_DB_number/ com m and_DB_address).
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Paramete.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Notes __.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Notes Pa.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Variable Description multitag MOBY U/D or RF300; maximum number of MDS processed in parallel in the field.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Command and Stat us Word "BEST" The control bits of FB45 are def ined in the comm and and status word.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Control bits from Bit0 to Bit7 Variable Description cancel True =interruption of a current comm and or a comm and string.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Control bits from Bit8 to Bit15 Variable Description ANZ_MDS_present Indicates the presence of an MDS in the transmis sion window of the Read/W rit e MDS.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C A dditional ind ications The display s indicate to the user the progress of a com m and.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Then, se.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Netwo rks 4 to 8 Note regarding netw orks 7and 8: The switch-on delay TO N (SFB4) in Network 7 and the FB45 call in Network 8 are added as multi- instance.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Save and.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.12 FB1 Control Program It is now possible to ge nerate the control program with the completed blocks.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 6 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 7 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Setting up T EM P Variables Netwo rk 1 to 2 FB10 is inserted as a multi-instance block .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 8 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Netwo rk.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 9 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Netwo rk.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 0 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C Netwo rk.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 1 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.13 OB1 Program Call Double click on OB1 in the project window, or open the object properties of O B1 and enter the symbolic name and the symbol comm ent.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 2 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 3 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 4 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 5 of 65 Module E11 Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and RF180C 5.
Een belangrijk punt na aankoop van elk apparaat Siemens DP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Siemens DP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Siemens DP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Siemens DP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Siemens DP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Siemens DP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Siemens DP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Siemens DP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.