Gebruiksaanwijzing /service van het product P23LINP van de fabrikant Smeg
Ga naar pagina of 15
INSTALLATION & USER INSTRUCTIONS All instructions must be handed to the user for safekeeping. M ODELS COVERED BY THESE INSTRUCTIONS P 2 3 L I N E A R - P 2 3 L I N P 2 3 C L A S S I C - P 2 3 C L L 2 3 L I N E A R - L 2 3 L I N L 2 3 C L A S S I C - L 2 3 C L L 3 0 F A B - L 3 0 F A B SMEG S.
• This applia nce is a high efficienc y, flueless catalytic flame effect gas fire. It provide s radiant and convecte d warmth both effi- cientl y and safel y utilising the latest type catalyti c converter and burner technol ogy.
Destination Country Cat Inlet Pressure (mbar) Max Energy Input (kW) Min Energy Input (kW) High Burner Pressure (±1.5 mbar) Low Burner Pressure (±0.75 mbar) G20 G25 Gross Net Gross Net Hot Cold Hot Cold AT, CH, CZ, HR, ES, FI, GB, GR, IE, IT, NO, SE, SK, TR I 2H 20 - 2.
Th is ap pl i a nc e ma y be i ns ta l l e d in an y ro o m in th e ho me ex c e p t ba t h r oo ms . If the appli- ance is to be fitted in a bedroom then an electronic carbon monoxide detector com- plying with the current edition of BSEN 50291 must be installed in the same room as the appliance .
R emove the outer packaging, remove any instructions or fixing kits. Read ALL these i nstructions before continuing to unpack or install this appliance. Lift off the remaining packaging components and remove the contents of the box. Check that the compo- nents suppl ied corr elate with the compon ent chec klist .
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then efforts should be made to fix in at least two positions vertically, into o ne of the wooden studs, or supporting wooden mem- bers of the wall using tw o of the fixing screws provid- ed.
Classic models : The control knob is located on the lower right hand side of the outer case. It is marked as s hown in figure 7; L inear models : The control knob is located on the lower right hand side of the outer case. It is marked as shown in figure 8; F ab models : The control knob is located on the lower right hand side of the outer case.
Please note that the Linear and Classic models are supplied with a tinted glass facia assembly, which dif- f er in appearance when viewed from the front, simi- larly the Fab model is supplied with a metal facia, however the method of attachment to the appliance, f or all frame designs, is the same.
Al l m o d el s : Fi r st l y, re mo v e th e dec o ra t iv e frame/glass facia assembly as described in section 8.3. Remove the inner glass panel, and disconnect the gas connection inside appliance. The gas con- nections to the gas valve can now be released.
It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures. The expect- ed life of the catalysts is in excess of 11,000 hours (10 years of normal use). After this time the catalysts should be replaced.
Fire sparks but pilot does not light No gas to fire, check isolators are open. Pipe work blockage, clean out. Air not fully purged, re purge supply or wait longer. Spark earthing to metal work, reset gap correctly. B locked pilot, clean out internally.
• The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes and/or Regulations, Building Regulations and the manufacturer's instructions.Failure to comply with the above could lead to prosecution and invalidate the appliance warranty.
Clearances to combustible materials Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any mate- rial, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible mate- r ial or surface.
Classic models : The control knob is located on the lower right hand side of the outer case. It is marked as shown in figure 2; Linear models : The control knob is located on the l ower right hand side of the outer case. It is marked as shown in figure 3; Fab models : The control knob is located on the lower right hand side of the outer case.
The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out b y a competent person.
Een belangrijk punt na aankoop van elk apparaat Smeg P23LINP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Smeg P23LINP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Smeg P23LINP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Smeg P23LINP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Smeg P23LINP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Smeg P23LINP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Smeg P23LINP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Smeg P23LINP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.