Gebruiksaanwijzing /service van het product 82S6XL020E van de fabrikant Solid State Logic
Ga naar pagina of 32
Super Analogue Mic Amp Owner ’ s Manual.
.
Solid State Logic Super -Analogue™ Outboar d Owner ’s Manual 82S6XL020E S U P E R A N A L O G U E M I C A M P.
XLogic Mic Amp Owner ’ s Manual As resear ch and development is a continual process, Solid State Logic r eserves the right to change the features and specifications described her ein without notice .
Page 1 Contents 1.0 Introduction 3 2.0 Safety Considerations 4 Safety W arnings 4 3.0 Installation 7 Setting the mains voltage selector 7 Mounting 7 Standalone Operation 7 Connecting to XL 9000 consoles 9 Connecting to XLogic Remote Control unit 1 1 Configuring the unit 13 4.
XLogic Mic Amp Remote (front) XLogic Mic Amp Remote (rear) XLogic Mic Amp (rear) XLogic Mic Amp (front) XLogic Mic Amp Owner ’ s Manual Page 2 XL SUPER ANALOGUE M I C A M P ogic MONITOR REMOTE SIGNA.
1.0 Introduction The XLogic Mic Amp is a 1U rack mounting unit containing four ultra high quality micr ophone amplifiers, utilising SSL ’s Super Analogue technology .
2.0 Safety considerations This section contains definitions and warnings, and practical information to ensure a safe working envir onment. Please take time to read this section befor e undertaking any installation work. 2.1 Definitions ‘Maintenance’ All maintenance must be carried out by fully trained personnel.
Mains Supply and Phases Solid State Logic equipment is designed for connection to single phase supplies with the Neutral conductor at earth potential - category TN - and is fitted with a protective fuse in the Live conductor only .
XLogic Mic Amp Owner ’ s Manual Page 6 240 120 100 240 230 120 100 240 230 120 100 240 230 100 100V 120V 23 0V 24 0V 100V Setting (Use for 90-105V) 120V Setting (Use for 105-125V) 230V Setting (Do n.
3.0 Installation 3.1 V oltage Selection Before connecting the mains supply ensur e that the voltage range selector next to the IEC socket on the r ear of the unit is correctly set. The input setting must be confirmed befor e applying power . The input module can be configured to be one of 4 voltage settings.
VIDEO 1 VIDEO 2 REMOTE MIC AMPS 1-4 REMOTE MIC AMPS 5-8 REMOTE MIC AMPS 9-12 REMOTE MIC AMPS 13-16 REMOTE MIC AMPS 17-20 REMOTE MIC AMPS 21-24 REMOTE MIC AMPS 25-28 REMOTE MIC AMPS 29-32 REMOTE MIC AM.
3.4 Connection to XL 9000 Consoles Remote mic amp prewiring has been fitted to many , but not all XL 9000 consoles. In many cases only a small number of channels have been wired. Check which (if any) bays of the console have been pr ewir ed for remote mic amps.
REMOTE 1/2 REMOTE 5/6 REMOTE 7/8 REMOTE 3/4 Solid St ate Logic OXFO RD • EN GLAN D RJ45-RJ45 (Cat 5) shielded pin to pin cable. SSL Pt.No. 66C673xx where xx is length in metres Channels 1-4 Channels 5-8 Console switched talkback output RJ11-RJ11 monitor bus link SSL Pt.
3.5 Connection to XLogic Mic Amp Remote The XLogic Mic Amp Remote (see drawing on page 2) is a 1U panel, appr oximately 100mm deep. Each unit will control one or two XLogic Mic Amp units (eight channels in total). It connects to each XLogic Mic Amp by two shielded RJ45 cables and is powered fr om the XLogic Mic Amp.
XLogic Mic Amp Owner ’ s Manual Page 12 Channel LK5 BCD Switch Front Panel Displays Address * Position Setting Display 1 Display 2 Display 3 Display 4 0 0 0 0 0 a 0 DP DP DP DP 0 0 0 0 1 a 1 1 2 3 4.
3.6 Configuring the XLogic Mic Amp There ar e a number of internal link settings, most of which should not normally r equire adjustment – see Appendix A for a full listing.
XLogic Mic Amp Owner ’ s Manual Page 14 +48V PHANTOM POWER +48V -20dB Hi-Z MIC TRIM +18 — +78dB MON Ø + - 25wD 25wD MON IN/MON OUT Headphone amp Stereo Jack DC Control from Console 25wD RJ45 -1 D.
4.0 Operation The XLogic Mic Amp is a 1U rack mounting unit containing four ultra high quality micr ophone amplifiers, utilising Solid State Logic’s Super Analogue technology .
XLogic Mic Amp Owner ’ s Manual Page 16 Channel LK5 (bit 5) BCD Switch Front Panel Displays Address * Position Setting Display 1 Display 2 Display 3 Display 4 x x x x x a 0 88 88 88 88 x x x x x a 1.
Appendix A – Internal links and fuses Fuses (Mains Inlet) The mains inlet contains a single 1 amp 1.25" time delay fuse (SSL Part No. 35FJJ310). T o change it disconnect the mains inlet, then using a small screwdriver prise open the mains selector cover .
XLogic Mic Amp Owner ’ s Manual Page 18 Appendix B: Connector Pinouts Mic Input Location: Front Panel Conn' Type: XLR Female P i n Description 1 Chassis 2 Audio +ve 3 Audio -ve Channel Outputs .
Appendix Page 19 Appendix B: Connector Pinouts ( continued ) Remote 1 - 2 Location: Rear Panel Conn' Type: 8-way RJ45 Socket Pin Description 1 Ch 2 Switch Control 2 Ch 2 Gain Control 3 Ch 1 Switc.
XLogic Mic Amp Owner ’ s Manual Page 20 Appendix B: Connector Pinouts ( continued ) T able 3a - XL 9000 DL to 25way ‘D’ W iring: Channels 1-8 / 25-32 / 49-56 / 73-80 Signal Cable # Colour DL Aud.
Appendix Page 21 Appendix B: Connector Pinouts ( continued ) T able 3b - XL 9000 DL to 25way ‘D’ W iring: Channels 9-16 / 33-40 / 57-64 / 81-88 Signal Cable # Colour DL Audio DL Control 25wD Male .
XLogic Mic Amp Owner ’ s Manual Page 22 Appendix B: Connector Pinouts (continued) T able 3c - XL 9000 DL to 25way ‘D’ W iring: Channels 17-24 / 41-48 / 65-72 / 89-96 Signal Cable # Colour DL Aud.
Appendix Page 23 Appendix B: Connector Pinouts ( continued ) T able 4 - Channel Address Bit Linking Channel Action Channel Action Channels 1-4 connect pin 11 Channels 49-52 connect pins 11, 12, 25 Cha.
Appendix C – Performance Specification Conditions: Source impedance 150Ω unless otherwise stated. All measurements ar e RMS and are made using a 22Hz to 22kHz filter unless otherwise stated.
THD + Noise In all cases THD is essentially unmeasurable, being less than the inherent noise of the amplifier until the output level exceeds +20dBu. Note: All THD+N measurements at gains above +30dB made using 40dB r esistive pad to minimise effect of generator noise at low signal levels.
Appendix D – Calibration Information The XLogic Mic Amp is factory calibrated and should only need calibration if a potentiometer or other component has been replaced or if it is suspected that ther e is a problem with calibration.
Appendix E – Physical Specification * Depth: 325mm/12.8 inches not including heatsink 365mm/14.3 inches including heatsink 400mm/15.75 inches including connectors Height: 44.5mm/1.75 inches (1 RU) W idth: 480mm/19 inches W eight: 4.1kg/9 pounds Power: 45 W atts/60 V A Max Boxed size: 520mm x 520mm x 182mm (20.
XLogic Mic Amp Owner ’ s Manual Page 28.
Een belangrijk punt na aankoop van elk apparaat Solid State Logic 82S6XL020E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Solid State Logic 82S6XL020E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Solid State Logic 82S6XL020E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Solid State Logic 82S6XL020E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Solid State Logic 82S6XL020E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Solid State Logic 82S6XL020E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Solid State Logic 82S6XL020E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Solid State Logic 82S6XL020E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.