Gebruiksaanwijzing /service van het product ICD-UX70 van de fabrikant Sony
Ga naar pagina of 64
ICD-UX70/UX80 GB 3-274-295-13(1) IC R ecorder Operating Instructions © 2007 Sony Corporation ICD-UX70/UX80 3-274-295- 13 (1) Getting Started Basic Operations V arious Recor ding Modes Playback/Erasin.
ICD-UX70/UX80 GB 3-274-295-12(1) 2 GB For the customers in the United States The following FC C statement applies only to the version of this model manufactured for sale in the USA.
ICD-UX70/UX80 GB 3-274-295-12(1) 3 GB T ab le of C on ten ts Checking the contents of the package ............................................................... 5 Index to Parts and Controls ..................... 6 Getting Started Step 1: Pr eparing a Power Sour ce .
ICD-UX70/UX80 GB 3-274-295-12(1) 4 GB Utilizing Y our C omputer Using the IC Recorder with Y our Computer ........................................................... 41 System requir ements ......................... 41 Connecting the IC recorder to your computer .
ICD-UX70/UX80 GB 3-274-295-12(1) 5 GB Ch eck ing th e c on te nt s of th e p ack age IC Recorder (1) LR03 (size AAA) alkaline battery (1) Stereo headphones (1) USB connection support cable (1) Operati.
ICD-UX70/UX80 GB 3-274-295-12(1) 6 GB In de x t o Pa rts a nd C on tr ols Refer to the pages indicated in parentheses for details . Fr ont Rear Operation indicator (14, 16, 17, 23, 38, 57) .
ICD-UX70/UX80 GB 3-274-295-12(1) 7 GB (record/pause) button (16, 17, 19, 35) (stop) button (17, 24, 25, 28, 31, 32) (cue/fast forward) button (23, 24, 25) .
ICD-UX70/UX80 GB 3-274-295-12(1) 8 GB Display windo w Operation mode indicator Displays the following , depending on the current operation mode : stop : playback : recording : recording standby.
ICD-UX70/UX80 GB 3-274-295-12(1) 9 GB : review/fast backward, cue/fast forward : going backward/forward continuously F older name/ Message title name/ Ar tist name indication Pr ess the control key toward or to display a folder name , message title name, and artist name in sequence.
ICD-UX70/UX80 GB 3-274-295-12(1) 10 GB Remaining recording time indication Displays the remaining recor ding time in hours, minutes, and seconds . If there is more than 10 hours time remaining, the time is displa yed in hours. If there is more than 10 minutes and less than 10 hours time remaining, the time is displayed in hours and minutes.
ICD-UX70/UX80 GB 3-274-295-12(1) 11 GB Getting Started Getting Started St ep 1: Pr epar in g a P ow er Sou rc e Inser ting the battery 1 Slide and lift the battery compartment lid. 2 Insert one LR03 (size AAA) alkaline battery with correct polarity , and close the lid.
ICD-UX70/UX80 GB 3-274-295-12(1) 12 GB When replacing/char ging the battery The remaining battery indicator on the display shows the battery condition. Battery remain indication : Replace the old battery with a new one or charge the rechargeable battery.
ICD-UX70/UX80 GB 3-274-295-13(1) 13 GB Getting Started When using Sony NH-AAA rechargeable battery Recording mode ST *3 STSP *4 Recording Approx. 9 hr . Approx. 9 hr . Playback *2 through speaker Approx. 13 hr . Approx. 13 hr . Playback using the headphones Approx.
ICD-UX70/UX80 GB 3-274-295-12(1) 14 GB Note while accessing The IC recorder is accessing data when an updating animation appears in the display window or the operation indicator ashes in orange or is lit in red. While the IC recorder is accessing data, do not remove the battery or connect or disconnect the USB AC adaptor (not supplied).
ICD-UX70/UX80 GB 3-274-295-12(1) 15 GB Getting Started 1 Select “DA TE & TIME” in the menu. Pr ess and hold /MENU for more than one second. The menu mode will be displayed in the display window . Pr ess the control key toward or to select “DE T AIL MENU, ” and then press ENT .
ICD-UX70/UX80 GB 3-274-295-12(1) 16 GB Basic Operations Re co rd ing Me ssa ges 2 3 1 Built-in microphones (headphone) jack Operation indicator 1 1 Select a folder .
ICD-UX70/UX80 GB 3-274-295-12(1) 17 GB Basic Operations 3 Press (stop ) to stop recording . The IC recorder st ops at the beginning of the current recording . Tips While recording you can lock all the functions of all the buttons so that you can prevent inadvertent operations by sliding the HOLD switch in the direction of the arrow .
ICD-UX70/UX80 GB 3-274-295-12(1) 18 GB Selecting the recording mode Select the recording mode in the “REC MODE” menu. ST : High- quality stereo recording mode (44.1 kHz/192 k bps) Y ou can record with stereo high- quality sound. STSP : Standard play ster eo recording mode (44.
ICD-UX70/UX80 GB 3-274-295-12(1) 19 GB Various Recording Modes Various Recor ding Modes St artin g t o Rec ord A ut oma ti call y i n Re spon se to Sou nd – the VO R F uncti on 2 1 1 Press the c ontrol key towar d or to set “VOR” to “ON” in the menu, and then press ENT .
ICD-UX70/UX80 GB 3-274-295-12(1) 20 GB Re co rd ing wi th an Ext ern al Mic ro pho ne Stereo mi cro pho ne 1 Connect an external microphone to the (microphone) jack when the IC recorder is in the st op mode. “SELEC T INPUT ” appears in the display window .
ICD-UX70/UX80 GB 3-274-295-12(1) 21 GB Various Recording Modes Re co rd ing fr om Oth er Eq uip men t T ape recorder , etc. 1 Connect other equipment to the IC recorder when the IC r ecorder is in the stop mode.
ICD-UX70/UX80 GB 3-274-295-12(1) 22 GB * Optional audio connec ting cables (not supplied) T o the IC recorder T o the other equipment RK-G139 HG Stereo mini-plug (w ith ou t re si st or) Mini-plug (mo.
ICD-UX70/UX80 GB 3-274-295-12(1) 23 GB Playback/Erasing Playback/Erasing Pl ay ing Ba ck Me ssa ges 4 5 3 (headphone) jack A-B 1 1 DPC Operation indicator 2 1 Select a folder . Pr ess /MENU. Pr ess the control key toward or to select the folder , and then press ENT .
ICD-UX70/UX80 GB 3-274-295-12(1) 24 GB 5 Press (stop ) to stop playback. After playing back the last message in the selected folder , the IC recorder stops at the beginning of that message.
ICD-UX70/UX80 GB 3-274-295-12(1) 25 GB Playback/Erasing When messages are play ed back to the end of the last message When you play back or fast play back to the end of the last message, “MESSAGE END” lights up for 5 seconds and the operation indicator lights up in green.
ICD-UX70/UX80 GB 3-274-295-12(1) 26 GB V arious playback modes Y ou can selec t “1 FILE” playback (one message/le is played back once), “FOLDER” playback (all the messages/les in the sel.
ICD-UX70/UX80 GB 3-274-295-12(1) 27 GB Playback/Erasing Playing back a specied section repeatedly – A-B Repeat 1 During playback, press (repeat) A-B to specify the starting point A. “ A-B B?” is displayed. 2 Press (repeat) A-B again t o specify the nishing point B.
ICD-UX70/UX80 GB 3-274-295-12(1) 28 GB 3 Set the alarm date and time. Pr ess the control key toward or to select “DA TE, ” a day of the week, or “DAIL Y , ” and then press ENT.
ICD-UX70/UX80 GB 3-274-295-12(1) 29 GB Playback/Erasing Notes Y ou can set only one alarm. When the clock has not been set or no messages are recorded , you cannot set the alarm. The alarm sounds even if you set “BEEP” to “OFF” in the menu (page 38).
ICD-UX70/UX80 GB 3-274-295-12(1) 30 GB Erasing messages one by one Y ou can erase unwanted messages, retaining all other messages when the IC recorder is in the stop or pla yback mode. When a message is erased, the remaining messages will advance and be renumbered so that ther e will be no space between messages.
ICD-UX70/UX80 GB 3-274-295-12(1) 31 GB Editing Messages Editing Messages Mo vi ng Mes sag e t o a Di ere nt F ol der Note When “ ” is displayed for the f older indicator , you cannot move a message (page 47). 1 Select the message you want to move .
ICD-UX70/UX80 GB 3-274-295-12(1) 32 GB Utilizing the Menu Function Ma king Set tin gs fo r th e M enu 2, 3 4 2, 3 1 1 Press and hold /MENU for more than one second to enter the menu mode.
ICD-UX70/UX80 GB 3-274-295-12(1) 33 GB Utilizing the Menu Function Menu settings Menu items S ettings Operation mode ( : the setting can be made/ : the setting can be made/ : the setting canno.
ICD-UX70/UX80 GB 3-274-295-12(1) 34 GB Menu items S ettings Operation mode ( : the setting can be made/ : the setting can be made/ : the setting cannot be made) Stop mode Playback mode Recordi.
ICD-UX70/UX80 GB 3-274-295-12(1) 35 GB Utilizing the Menu Function Menu items Settings (*: Initial setting) REC MODE Sets the rec ording mode. ST: Stereo high-quality recording mode. STSP*: *: : Stereo standard r ecording mode. STLP: Stereo long play r ecording mode.
ICD-UX70/UX80 GB 3-274-295-12(1) 36 GB Menu items Settings (*: Initial setting) DISPLA Y Changes the display mode. ELAPSE*: Elapsed playback time of one message REMAIN: During playback, the remaining .
ICD-UX70/UX80 GB 3-274-295-12(1) 37 GB Utilizing the Menu Function Menu items Settings (*: Initial setting) EFFECT POP: Stresses middle ranges, ideal f or vocals. ROCK : Emphasizes high and low ranges for a po wer ful sound. JAZZ: Emphasizes high ranges for a lively sound .
ICD-UX70/UX80 GB 3-274-295-12(1) 38 GB Menu items Settings (*: Initial setting) PLA Y MODE Sets the playback mode. 1 FILE: When a message is played back, the IC recorder stops at the beginning of the next message. FOLDER*: Messages in one folder are played back continuously .
ICD-UX70/UX80 GB 3-274-295-12(1) 39 GB Utilizing the Menu Function Menu items Settings (*: Initial setting) BACKLIGHT T urns the backlight in the display window on or off. ON*: The backlight in the display window lights up for 10 seconds. OFF: The backlight in the display window does not light, even during operation.
ICD-UX70/UX80 GB 3-274-295-12(1) 40 GB Menu items Settings (*: Initial setting) DET AIL MENU SELECT INPUT Selects the external input to be recorded that is connected to the (microphone) jack. MIC IN*: Select when you record messages using an external microphone.
ICD-UX70/UX80 GB 3-274-295-12(1) 41 GB Utilizing Y our Computer Utilizing Y our Computer Y our Computer U sin g t he IC Rec ord er wi th Y ou r C omp ut er Sy stem requirements Operating sy stems: Win.
ICD-UX70/UX80 GB 3-274-295-12(1) 42 GB Connecting the IC recor der to your c omputer Y ou can transfer the IC recorder data onto your computer by connecting the IC recorder to the comput er . Remove the USB cap fr om the IC recorder and then connect the IC recorder to the USB connector of your computer .
ICD-UX70/UX80 GB 3-274-295-12(1) 43 GB Utilizing Y our Computer Notes If you connect more than two USB devices to your computer , nor mal operation will not be guaranteed. Use of this IC recorder with a USB hub or a USB connection suppor t cable other than the supplied cable is not guaranteed.
ICD-UX70/UX80 GB 3-274-295-12(1) 44 GB Notes Y ou can use the transcribing feature only when you have installed Dragon NaturallySpeaking Selec t or Prof essional Edition (not supplied) on your computer . T o install Dragon NaturallySpeak ing, your computer should meet the specified system requirements.
ICD-UX70/UX80 GB 3-274-295-12(1) 45 GB Utilizing Y our Computer Tips on using the IC recorder When transcribing messages recorded using the IC recorder , the following tips will help you obtain maximum recognition accuracy . Set “REC MODE” to “ST , ” “STSP , ” “STLP” or “SP ” in the menu.
ICD-UX70/UX80 GB 3-274-295-12(1) 46 GB 1 Connect the IC recorder t o your computer (page 42). On the Windows screen; open “My Computer” and make sure that “IC RECORDER” has been ne wly recognized . On the Macintosh screen; make sure that a “IC RECORDER” drive is displayed on the desk top.
ICD-UX70/UX80 GB 3-274-295-12(1) 47 GB Utilizing Y our Computer Construction of folders and les The folders and les ar e displayed on the computer screen as shown.
ICD-UX70/UX80 GB 3-274-295-12(1) 48 GB *1 The name of a folder in which MP3 files are stored will be displayed on the IC r ecorder as it is, so it is convenient if y ou put an easy-to- remember name on the folder in advance .
ICD-UX70/UX80 GB 3-274-295-12(1) 49 GB T roub les hoo tin g T roubleshooting T ro ubl esh ooti ng Before taking the IC recorder f or repair , check the following sections. Should any problem persist after you have made these checks , consult your nearest Sony dealer .
ICD-UX70/UX80 GB 3-274-295-12(1) 50 GB Symptom Remedy “FILE FULL ” is displayed and you cannot operate the IC recorder . 99 messages have been recor ded in the selected folder or 495 messages (when there are 5 f olders) in total have been recorded .
ICD-UX70/UX80 GB 3-274-295-13(1) 51 GB T roub les hoo tin g Symptom Remedy There are f ewer menu items displayed in the menu mode. The menu items displayed ar e dierent depending on the operation modes (stop mode, playback mode , and recording mode) (pages 33, 34).
ICD-UX70/UX80 GB 3-274-295-12(1) 52 GB Error messages Error message Cause/Remedy BA T TERY L O W Y ou cannot format the memory or erase all the les in a folder because of insucient battery power . Prepare a new battery to replace the current one.
ICD-UX70/UX80 GB 3-274-295-12(1) 53 GB T roub les hoo tin g Error message Cause/Remedy SET DA TE&TIME Set the clock; other wise, you cannot set the alarm. NO FILE The selected folder does not have an y messages. Y ou cannot move a message or set the alarm, etc.
ICD-UX70/UX80 GB 3-274-295-12(1) 54 GB Sy stem limitations There are some syst em limitations of the IC recorder . T roubles as mentioned below are not malfunctions of the IC recorder . Symptom Cause/Remedy Y ou cannot record messages up to the maximum recording time .
ICD-UX70/UX80 GB 3-274-295-12(1) 55 GB Additional Information Additional Informa tion Re co rd ing wi th Othe r Eq uip men t T ape recorder , etc. T o (headphone) jack T o audio input connector T .
ICD-UX70/UX80 GB 3-274-295-12(1) 56 GB U sin g a US B A C A dap to r ( not su ppl ied ) USB connector of the IC recorder USB AC adaptor (not supplied) Y ou can connec t the IC recorder to an AC outlet using a USB AC adaptor AC-U50A/ AC-U50AD (not supplied).
ICD-UX70/UX80 GB 3-274-295-12(1) 57 GB Additional Information Notes During recording (the operation indicator lights or flashes in red) or accessing data (the operation indicator flashes in orange), the IC recorder should not be connected to or disconnected from the USB AC adaptor connected to the AC outlet.
ICD-UX70/UX80 GB 3-274-295-12(1) 58 GB On noise Noise may be heard when the unit is placed near an AC power sour ce, a uorescent lamp or a mobile phone during recording or playback. Noise may be recorded when an object, such as your nger , etc., rubs or scratches the unit during recording .
ICD-UX70/UX80 GB 3-274-295-13(1) 59 GB Addi tion al In form ati on Speaker Approx. 10 mm (13/32 in.) dia. Po wer output 90 mW Input/Output Microphone jack (minijack, stereo) input for plug in power , minimum input level 0.
ICD-UX70/UX80 GB 3-274-295-12(1) 60 GB In de x A A-B Repeat .....................................................................27 Adjusting the volume .....................................18, 23 Alarm ................................................
ICD-UX70/UX80 GB 3-274-295-12(1) 61 GB I ndex M Maintenance.................................................................58 Menu ALARM ................................................................ 33, 39 BACKLIGHT ...............................
ICD-UX70/UX80 GB 3-274-295-13(1) 62 GB S Setting the Clock ....................................................... 14 SP ............................................ 9, 13, 18, 33, 35, 54, 58 Specications ...........................................
ICD-UX70/UX80 GB 3-274-295-12(1) 63 GB I ndex.
ICD-UX70/UX80 GB 3-274-295-13(1) Printed in China.
Een belangrijk punt na aankoop van elk apparaat Sony ICD-UX70 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sony ICD-UX70 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sony ICD-UX70 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sony ICD-UX70 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sony ICD-UX70 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sony ICD-UX70 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sony ICD-UX70 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sony ICD-UX70 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.