Gebruiksaanwijzing /service van het product 3015-4256 van de fabrikant Bacharach
Ga naar pagina of 36
HGMSZ Halogen Gas Monitor Single Zone Instruction 3015-4256 Installation / Operation / Maintenance Rev. 0 – January 2004 Product Leader ship • Training • Se rvice • Re liability MONITOR ON SYSTEM FAULT ALARM ENTER HGMSZ HALOGEN GAS MONITOR SINGLE ZONE SILENCE / QUIT Complies with UL 61010A-1 and CSA 22.
A Instruction 3015-4256 Declaration of Conformity Manufacturer’s name: Bacharach, Inc. Manufacturer’s address: 621 Hunt Valley Circle New Kensington, PA 15068 European Operations: Bacharach Europe.
Table of Contents INTRODUCTION ................................................................................................................... ........................ 1 How to Use Th is Ma nual ....................................................
ii Instruction 3015-4256 Working with Sy stem Faults ..................................................................................................... ........... 18 Functional Overview .............................................................
Introduction How to Use This Manual Thank you for investing in a BACHARACH HGMSZ (Halogen Gas Monitor Single Zone). This manual provides im portant inform ation on ho w to instal l, operate, and service the HGMSZ monitoring unit.
2 Instruction 3015-4256 Safety Precautions AC Power Supply The HGMSZ uses a universal power supply that is capable of accepting inp uts of 100 to 240 VAC, 50/60 Hz.
Instruction 3015-4256 3 Functional Overview General Description Refrigerant monit ors are specified to support com pliance to federal, state a nd local safety cod es governing refrigerant em issions.
4 Instruction 3015-4256 Suggested Location of Sampling Point At the point of a refr igerant leak the g as is nearly pure. As the refr igerant is dispersed into the air, th e gas molecules diffuse causin g a dilution of the or iginal conc entration. Th e HGMSZ measures the refri gerant concentration at the p oint the sample is col lected.
Installation Installation Considerations Warnings and Cautions WARNING: Drilling holes in the HGMSZ enclosure will void the warranty. Please use knockouts provided for electrical connections. WARNING: Do not mount the HGMSZ in an area that may contain flammable liquids, vapors or aerosols.
6 Instruction 3015-4256 Mounting Instructions The HGMSZ should be ins talled plumb and level and securely fasten ed to a rigid mountin g surface. The enclosur e utilizes keyh ole mounting brack ets designed for #12 pan head s crews. Locate the four screws as shown in the diagram below and leave the screw h eads protruding approximat ely 3/16".
Instruction 3015-4256 7 Tubing Considerations ¼" outside diamet er (0.040" wall) fl ex tubing is used for a ll air lines (P/N 304 -2743) or equ ivalent. The tubing should be clean a nd free of moisture or other contamina nts. The tubing should be cut cle anly with a sharp knife and care should be tak en not to distort the tubing end.
8 Instruction 3015-4256 Interior Schematic Interior Schematic LINE FUSES 1.0A, 250V, F UNIVERSAL POWER SUPPLY EXTERNAL ALARM RELAYS HYDROPHOBIC FILTER FACTORY DEFAULT SWITCH SW3 CPU RESET SWITCH SAMPLE PUMP CHARCOAL FILTER (Used to remove refrigerant gas from the purge air) AC INPUT TERMINALS GND LINE LINE 1 2 CLOCK BATTERY 4–20 MA (Signal Out.
Instruction 3015-4256 9 Electrical Wiring The HGMSZ uses a universal power supply that is capable of accepting inp uts of 100 to 240 VAC, 50/60 Hz. The monitor’s power consumption is 15 Watts. It is high ly recommended t hat the monitor be connected directly to the AC power source, preferably on its own ci rcuit.
10 Instruction 3015-4256 Connecting External Alarms Overview The HGMSZ includes four SPDT relays whose contacts are rat ed 3 A at 240 VAC. These relays ar e used for the connectio n of external a larm devices that are acti vated when the re lay is energized.
Instruction 3015-4256 11 Typical External Alarm Relay 1 Wiring Jumper the ‘Neutral’ line of an external power source or the monitor’s AC input to the ‘Comm on’ terminals on the relay connector. Connect one end of the strobe or horn to the ‘NO’ terminal of whichever level of alarm is a ppropriate for the application.
12 Instruction 3015-4256 Notes:.
Instruction 3015-4256 13 Operation Front Panel Display and Controls General Operation Once the HGMSZ has been installed, set up, and powe red ON, it will make measur ements in the area being sampled for r efrigerant gas w ithout further o perator intervent ion.
14 Instruction 3015-4256 If a system fault occurs (see F ault Code list on Pag e 19), the monitor resp onds by turning ON the fro nt panel SYSTEM FAULT (yello w) light and en ergizing the fault rela y. If the intern al audible alarm is turned ON, it too will acti vate.
Instruction 3015-4256 15 Function Screens The Function screens are used to display stored dat a and to set up the monitor. From the Data Display s creen, press any Keypad button to displa y the first Function Menu screen.
16 Instruction 3015-4256 DIAGNOS – Enters the diagnostic fu nction. Press the Up Arrow Keypad button to toggle betw een the monitor’s two dia gnostic screens.
Instruction 3015-4256 17 AUDALRM – Allows the monitor’s internal audible alarm to be associated with any function o f the monitoring syst em. Factory defaul t is OFF. Use the Keypad to select the d esired audible alarm function, and then press ENTER to save that value and return to the previo us screen.
18 Instruction 3015-4256 Working with Gas Alarms Functional Overview If the refrigerant l evel in the area being m onitored exce eds its preset Leak, Spil l, or Evacuate Alarm level (Page 17), the HGMSZ will d etect this alarm condit ion and turn ON the front panel ALARM light.
Instruction 3015-4256 19 Viewing the Fault Log From the Data Display s creen, use the Keypad buttons to place the arr ow (>) on the display next to t he FAULTS fu nction. Then press EN TER to display the fault log. Immediately after selecting the FAULTS funct ion, the most recent fault event is disp layed.
20 Instruction 3015-4256 Clearing the Stored PPM Log, Alarms & Faults Data Up to 200 refrigerant gas ppm measurements, and 30 al arm an d fault event s are stored by th e monitor. To clear stored data, first display the data t o be cleared by using the PPM Log , Alarms or Faults function (Pages 15).
Instruction 3015-4256 21 Working with the DIAGNOS Function Overview The DIAGNOS function displays sensor data and status in form ation useful to a service t echnician for troubleshooti ng various fault condit ions. Explan ations of the data shown in t hese screens are given b elow.
22 Instruction 3015-4256 Working with the P-CHK Function Overview The P-CHK function (Pressure Check Function) (Page 17) is useful to a servic e technician for troubleshooti ng a flow fault probl em. The monitor w ill trigger a flow fau lt if the pressure drop from ambient is less than 0.
Instruction 3015-4256 23 Working with the Calibration Function Overview If greater than standard accuracy is desired on any pa rticular gas, the factory’s default calibration factor of 1.
24 Instruction 3015-4256 Notes:.
Instruction 3015-4256 25 Maintenance Warnings and Cautions WARNING: Always disconnect AC power before working inside the monitor. CAUTION: When working inside the monitor, be very careful not to dislodge any electrical wiring or pneumatic tubing. The HGMSZ contains sensitive electronic components that can be easily damaged.
26 Instruction 3015-4256 Replacement Parts & Optional Accessories Replacement Parts Item Description Part Number HGMSZ, complete assembly ........................................... 3015-4200 Battery, Panasonic BR 2032, 3 V .......................
Instruction 3015-4256 27 Appendix Table of Recommended Alarm Settings Refrigerant Leak PPM Spill PPM Evacuate PPM R11 100 300 500 R12 100 300 500 R22 100 300 500 R23 100 300 500 R113 100 300 500 R114 .
28 Instruction 3015-4256 WARRANTY and SERVICE Warranty Subject to the terms herein, Seller war rants the or iginal equipment cat aloged or manufactured by the Seller and furnished hereunder is free from defects in materia l and workmanship, and w ill be of the kind and quality designat ed or described on the quotati on.
Instruction 3015-4256 29 Return Procedure To return equipment to the factor y for repair a Return Authorization (RA) number should be requested from the factory. Normal f actory repair t ime is approximatel y two (2) weeks, unless sp ecial provisions have been pr e-negotiated p rior to the issuance of an RA number.
30 Instruction 3015-4256 Specifications Product Type ........................ Multiple refrigerant gas monitoring system fo r low level continuous monitoring of refrigeran t gases Gas Library .
.
Bacharach, Inc. 2 Dart Road, Newnan GA 30265 Ph: 678-423-2481 • Fax: 678-423 -2479 Website: www.bacharach-inc.com • E-mail: help@bacharach-inc.com Printed in U.
Een belangrijk punt na aankoop van elk apparaat Bacharach 3015-4256 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Bacharach 3015-4256 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Bacharach 3015-4256 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Bacharach 3015-4256 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Bacharach 3015-4256 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Bacharach 3015-4256 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Bacharach 3015-4256 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Bacharach 3015-4256 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.