INS TRUCT ION MANUAL FOR SPEEDO TRON BROWN LINE EQUIPMENT .
2 3 T ABLE OF C ONTENT S Power Supplies General Information – Read This First . . . . . . . . . . . . . . . . . . . 4 Models D604, D1204, D1604 Description of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operating Instructions .
4 5 Speedotron power supplies are equipped with arc-protected outlets. However, as with any electrical equipment, arc-over (an electrical discharge between two physically dis- connected electrical terminals) is a possibility. When light cables, flash tubes or power cords are improperly seated, arc-over may occur.
6 7 OPERA TING INS TRUC TIONS Operation of the D604, D1204 and D1604 power supplies is simple and straight for- ward. This sequence of operation is suggested for maximum life and dependability. Make sure that the Model and Power switches are in the off position and the Push to Reset button is fully depressed into its socket.
8 9 One light: Symmetrical mode in any outlet, will receive 600Ws. Asymmetrical mode in outlets 1 or 2, will receive 600Ws; when using outlets 3 or 4 output is 450Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 300Ws (600Ws divided by 2).
10 11 One light: Symmetrical mode in any outlet will, receive 1600Ws. Asymmetrical mode in outlets 1 or 2, will receive 1600Ws; when using outlets 3 or 4 output is 1200Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 800Ws (1600Ws divided by 2).
12 13 D1204 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .1200Ws Number of light unit outlets: . . . . . . . . . . . .4 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 1200 4.1 600 2.0 300 1.0 Flash duration : .
14 15 *New MW9H flashtubes supplied with M11 light units handle up to 1200Ws. The MW9M flashtubes have a maximum capacity of 1000Ws. OPERA TING INS TRUC TIONS Operation of Brown Line power supplies is simple and straight forward. It is suggest- ed that this sequence of operation be utilized for maximum life and dependability.
16 17 One light: Symmetrical mode in any outlet, will receive 800Ws. Asymmetrical mode in outlets 1 or 2, will receive 800Ws; when using outlets 3 or 4 output is 600Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 400Ws (800Ws divided by 2).
18 19 DESCRIPTION OF C ONTROL S Power – turns power supply on and off. (Flashes light units when turning off.) Model – turns model lamps on and off. Symmetrical/Asymmetrical – controls power distribution. In the symmetrical position, power is split equally between all lights.
20 21 200 100 50 150 TE CHNICAL SPE CIFICA TIONS D202 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .200Ws Number of light unit outlets: . . . . . . . . . . . .2 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 200 3.
22 23 To connect light units, align the light unit plug with the power supply outlet and apply even pressure while pushing. Black colored light unit connectors are of the “ quick release ” type that only require pushing the connector firmly until it is fully seated.
24 25 T echnical Specifications Maximum power: MW3 (for MW3R, MW3U, M90) . . . . . . . . . . . . . .400Ws MW3C (for MW3R/CC, MW3U/CC, M90/CC) . . .400Ws MW3Q (for MW3UQ, M90Q) . . . . . . . . . . . . . . . .1200Ws MW3QC (for MW3UQ/CC, M90Q/CC) . . . .
26 27 UNIVERSAL LIGHT UNIT S (REMO V ABLE REFLE CT ORS) M11, M11/CC, M11Q and M11Q/CC The M11 series universal light units share a common base, but are differentiated by the type of flash tube each contains.
28 29 TROUBLE-SHOO TING System will not work at all; no flash. Check that sync cable, AC power cord and light unit cables are firmly and properly attached.
30 31 Ws per flash tube MW3-1 MW3Q MW9H MW9Q 100Ws 1/1500 1/1500 1/3000 1/3000 200Ws 1/1200 1/1200 1/2200 1/2200 400Ws 1/750 1/750 1/1400 1/1400 600Ws - 1/580 1/1000 1/1000 800Ws - 1/450 1/700 1/700 1.
© 1997 Speedotron Corporation SPEEDO TRON’S LIMITED W A RRANTY Speedotron guarantees to repair or replace, free of charge, any part or parts (except for flash tubes and modeling lamps) found by factory inspection to be defective due to faulty material or workman- ship, provided the equipment is returned to our factory prepaid.
Een belangrijk punt na aankoop van elk apparaat Speedotron D1204 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Speedotron D1204 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Speedotron D1204 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Speedotron D1204 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Speedotron D1204 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Speedotron D1204 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Speedotron D1204 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Speedotron D1204 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.