Gebruiksaanwijzing /service van het product CD12 van de fabrikant Stanley Black & Decker
Ga naar pagina of 22
© 2014 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 62379 8/2014 V er . 4 USER MANUAL Safety , Operation and Maintenance CD12 Hydraulic Core Drill.
.
CD12 User Manual ◄ 3 SERVICING: This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized and certied dealer .
4 ► CD12 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
CD12 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual, and on the stickers and tags attached to or on the tool and hose(s). These safety precautions are for your safety . Review them carefully before operating the tool or performing any maintenance or repairs.
6 ► CD12 User Manual SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
CD12 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► CD12 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
CD12 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max.
10 ► CD12 User Manual GENERAL OPERA TION The tool comes with a set of accessories which may be customized by each purchaser , so as to facilitate per- formance of all work occurring within the scope of his specic application. T ools included are for mounting and dismounting.
CD12 User Manual ◄ 1 1 DRILLING WITH CD12 ANCHOR ST AND The anchor stand may be used with a vacuum pump for a vacuum hold down or with a concrete anchor screw to hold the stand in place while drilling. The standard ar- rangement of the anchor stand is for use with a vacuum pump.
12 ► CD12 User Manual 12. NO TICE Manually screw the corresponding drill bit from below onto the drill bit adapter . Manual tightening is sufcient because the drill bit will automatically tighten further during the drilling operation. Connect the core drill to a water supply .
CD12 User Manual ◄ 13 ANCHOR ST AND TROUBLESHOOTING Symptom Cause Solution The Anchor Stand will not hold a vacuum. Debris under the base gasket is preventing a good seal. Clean the surface on which the gasket must seal. Debris between the base gasket and the base.
14 ► CD12 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hy- draulic system.
CD12 User Manual ◄ 15 When diagnosing faults in operation of the grinder , always check that the hydraulic power source is supplying the correct hydraulic ow and pressure to the grinder as listed in the table. Use a owmeter known to be accurate.
16 ► CD12 User Manual Problem Cause Solution Fluid gets too hot. Circuit relief set too low . Adjust relief valve to 2100-2250/145- 155 bar . T oo much uid going through tool. Adjust ow for 6 gpm/23 lpm maximum. Circuit has contaminants that have caused wear and high heat genera- tion.
CD12 User Manual ◄ 17 System T ype .................................................................................................................................... HTMA T ype II OC Flow Range .....................................................
18 ► CD12 User Manual CD12 P ARTS ILLUSTRA TION.
CD12 User Manual ◄ 19 ITEM P ART NO. QTY DESCRIPTION 6531 1 MOTOR ASSEMBL Y 101 65207 1 MOT OR HOUSING 102 41254 1 OUTPUT SHAFT 103 41255 1 SPUR GEAR 104 41256 1 SHAFT SEALING 105 41257 1 SNAP RING .
20 ► CD12 User Manual CD12 ANCHOR ST AND ILLUSTRA TION.
CD12 User Manual ◄ 21 ITEM P ART NO. QTY DESCRIPTION 1 65214 1 HANDLE 2 65215 1 ST OP PLA TE 3 65216 2 HSH CAPSCREW 4 65217 4 HSFH SCREW 5 65218 1 CLAMP PLA TE 6 65219 1 DRILL ST AND COLUMN 7 65220 .
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
Een belangrijk punt na aankoop van elk apparaat Stanley Black & Decker CD12 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Stanley Black & Decker CD12 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Stanley Black & Decker CD12 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Stanley Black & Decker CD12 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Stanley Black & Decker CD12 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Stanley Black & Decker CD12 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Stanley Black & Decker CD12 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Stanley Black & Decker CD12 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.