________________________________ Continuous Loss-in-Weight Blenders with Allen-Bradley SLC 5/04 Programmable Controller and PanelView 600 Touch Screen Interface Part Number: 882.
Continuous Loss-in-Weight Blenders ii Shipping Information Unpacking and Inspection You should inspect your equipm ent for possible shipping damage. Thoroughly check the equipment for any damage that m ight have occurre d in transit, such as broken or loose wiring and components, loose hardware and mounting screws, etc.
Continuous Loss-in-Weight Blenders iii Credit Returns Prior to the return of any material, authorization must be given by the manufacturer. A RMA number will be assigned for the equipment to be returned. Reason for requesting the return must be given.
Continuous Loss-in-Weight Blenders iv Table of Contents CHAPTER 1: SAFETY ................................................................. 6 1-1 How to use this manual ..................................................................................
Continuous Loss-in-Weight Blenders v MAINTENANCE .......................................................................... 52 Preventative maintenance schedule .................................................................................... 52 APPENDIX .
Continuous Loss-in-Weight Blenders Chapter 1: Safety 6 Allen-Bradley Controls Chapter 1: Safety 1-1 How to Use This Manual Use this manual as a guide and reference for installing, operating, and maintaining your Continuous Loss-in-weight Blender.
Continuous Loss-in-Weight Blenders Chapter 1: Safety 7 Continuous Loss-in-Weight Blender Safety Tags Tag Description Tag Description Pinch Point - Slide Gate Read Operation & Installation Manual S.
Continuous Loss-in-Weight Blenders Chapter 1: Safety 8 1-2 Warnings and Precautions Our equipment is designed to provide safe and reliable operation when installed and operated within design specifications, following pertinent local and national codes.
Continuous Loss-in-Weight Blenders Chapter 1: Safety 9 1-3 Responsibility These machines are constructed for maximum operator safety when used under standard operating conditions and when recommended inst ructions are followed in the maintenance and operation of the machine.
Continuous Loss-in-Weight Blenders Chapter 1: Safety 10 Operator Responsibility The operator’s responsibility does not end with e fficient production. The operator usually has the most daily contact with the equipment and intimately knows its capabilities and limitations.
Continuous Loss-in-Weight Blenders Chapter 1: Safety 11 • Clean the blender and surrounding area DAILY , and inspect the machine for loose, missing or broken parts. • Shut off power to the blender when it is not in use. Turn the switch to the OFF position, or unplug it from the power source.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 12 Chapter 2: Functional Description 2-1 Models Covered in This Manual This manual provides operation, installation, an d maintenance instructions for co ntinuous loss-in-weight blenders of various blending rates and specifications.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 13 2-3 Typical Features & Components Mechanical Features • Blender automatically adjusts individual feeders to match learne d extruder rate at the ratio required. • Upper material supply hoppers with conical re-fill valves and dust boots.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 14 Blender System Component Description This section describes the various components of the continuous blending system.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 15 hoppers are not controlled nor read by the blender. Their existence is solely for the use of a low level alarm to be wired into a separate controller. These would not be present on a standard blender.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 16 Ingredient Metering/Transport Auger Assemblie s Each metering auger assembly consists of a: • Cast aluminum motor mount • Ca.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 17 Lower Mass Flow Weigh Hopper Assembly The lower mass flow weigh hopper, otherwise known as the weighed common hopper, is used to determine the actual processing rate of the processing machine so that the blender can be slaved in to run at the learned rate.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 18 PLC Control Panel The PLC control panel may be mounted on the side o f the blender frame, or remote mounted near the blender. It uses an Allen-Bradley SLC 5/04 programmable cont roller with standard 24 vdc input output cards.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 19 2-4 Options The following is a list of options, which y our blender may have been equipped with: • Mezzanine stand with slide gate and 4” tube stub. • Low-level proximity switches.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 20 2-5 Safety Device s and Interlocks This section includes information on safety devices and procedures that are inherent to the continuous loss-in-weight blender. This manual is not intended to supersede or alter safety standards established by the user of this equipm ent.
Continuous Loss-in-Weight Blenders Chapter 2: Functional Description 21 Safety Device Lock-Outs Some safety devices disconnect electrical energy from a circuit.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 22 Chapter 3: Inst allation 3-1 Uncrating the Equipment Continuous loss-in-weight blenders are shipped bolted on a skid, enclosed in pla stic wrap, and contained in a wood crate. 1. Remove the crate from around blender.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 23 Site Requirements This section describes site requirements in detail. These requirements are broken down into mechanical mounting, electrical connecti ons and pneumatic connections.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 24 Note: Never weld on the blender’s fr ame, machine or mezzanine without first removing the contro l panel and verifying that the blender’s power is disconnected. Mezzanine Mount In a mezzanine mount application, review th e following items before installation begins.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 25 Note: Ensure that the feed tube angle is steep enough (60 degrees is recommended). Note: Some mezzanine mount applications w ill require the blending system’s lower mass flow hopper be mounted on the ex truder throat.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 26 Figure 8: Typical Layout for a floor mounted blender 3-3 Electrical Installation The continuous loss-in-weight blending system is designed to operate on 115 volt, single phase, 50 or 60 hertz AC power.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 27 3-4 Pneumatic Installation The blending system utilizes air pneumatics to perform the re-fill function on the ingredient weigh hoppers. The manufacturer provides all pneumatic plumbi ng to a single ¼” standard pipe thread fitting.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 28 3-5 Overall Installation (Summary) This installation procedure should be used as a general guideline for the proper installation steps required to install the continuous loss-in-weight blending s ystem.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 29 3-6 Set-up This section will discuss the mechanical setup a nd control system setup of the continuous loss-in-weight blending system. After reading this section, you should be fam iliar with the mechanical setup and the electronic control setup of the blending s ystem.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 30 Final Connections 1. Connect the blender to the appropriate power source. 2. Connect the compressed air piping, ensuring that a 5-micron air filter is installed, along with the proper water trap, and lubricati on unit, if required.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 31 Controller Setup This section describes the proper setup of the c ontinuous loss-in-weight blending system control parameters. These parameters are ope rator changeable; however, these items should only require setup during the initial installation.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 32 will suffice. The weight will be in pounds, unl ess the blender is provided for metric display operation (kilograms). Given the two weight points on the load cell scale, the controller will be able to determine any other weight on the load cell span.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 33 Touch the “ACS Group” logo in the upper left ha nd corner. You will be prom pted to enter a password - it is “5413”. You will see the “Password Accep ted” screen, now press “OK”.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 34 Touch “Scale” button Find your calibration weight that shipped with th e ble nder and locate the Weight information stamped on the weight proceed as follows. 1. Enter weight value stamped on the weight in Cal Wt Box .
Continuous Loss-in-Weight Blenders Chapter 3: Installation 35 Touch the “ ACS Group” Logo. Then enter password “5413”. Touch the “OK” button.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 36 Touch “Feeder” button Feeder Calibration is carried out as follow s: 1. Select the feeder you want to calibrate and enter the value in Feeder# by touching the adjacent box. 2. Determine the calibration weight and enter it in the box for Cal Wt .
Continuous Loss-in-Weight Blenders Chapter 3: Installation 37 Figure 12: Hopper Sizes Hopper Diameter (inches) Approximate Hopper Capacity (@35 lbs. / cu. ft.) 9 7 12 14 14 18 20 40 24 60 Above lists standard sizes and can vary depending on the blender requireme nts and rates to be blended.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 38 Touch “ Hopper Setup” Touch the box next to the hopper number that y ou want to change and enter weight value. Setting Passwords There are three levels of password security for the control system.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 39 To change a password proceed as follows: Touch the “ ACS Group” logo. Enter password and touch “ OK” .
Continuous Loss-in-Weight Blenders Chapter 3: Installation 40 -Enter original password. -Touch box next to select operator until you see the level you want to set.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 41 First you must get to the Alarm Setup Page. To d o this; Touch the “ ACS Group” l ogo .
Continuous Loss-in-Weight Blenders Chapter 3: Installation 42 All alarm parameters are selectable. If you do not want to use an alarm for a feeder, ensure the corresponding box has an “ N” in it. To be enabled, the box must have a “ Y” in it. You can also decide to let the Blender continue to Run or Stop if an alarm is active.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 43 Setting Blender for English or Metric Touch the “ ACS Group” logo. Enter the password and touch “ OK” .
Continuous Loss-in-Weight Blenders Chapter 3: Installation 44 Touch the box that says “ English Units” to toggle between English and Metric ****Note, you must re-calibrate the blender and reset the in ventory values if you change this value.*** How to use FIFO Diagnostics First you must get to the FIFO screen.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 45 Enter the Password and touch “ OK” Touch “ FIFO Diagnostics” Select “ Mass Flow FIFO Data” or “Feeder FIFO Data”.
Continuous Loss-in-Weight Blenders Chapter 3: Installation 46 The Following screens will appear. This data is provided for trouble shooting blender stability problems. If you are not getting a steady system indication or if you are getting an unstable system alarm you can check here for the problem.
Continuous Loss-in-Weight Blenders Chapter 4: Operation 47 Chapter 4: Operation 4-1 Start-up The objective of this chapter is to familiarize the reader with the blender’s recipe menu, run mode operation and displays.
Continuous Loss-in-Weight Blenders Chapter 4: Operation 48 The blender will blend at a maximum rate when the lower mass flow weigh hopper has a very low weight of material. As the weight of mate rial increases in the mass flow weigh hopper, th e controller will adjust the blender feeders out put to match the calculated processing machine rate.
Continuous Loss-in-Weight Blenders Chapter 4: Operation 49 4-2 Controller Description & Operation Display Description The controller on the continuous loss-in-weight blender, utilizes a LCD touch screen display. Figure 14: Typical Controller Display A typical menu entry is shown in the figure above.
Continuous Loss-in-Weight Blenders Chapter 4: Operation 50 “Invento ry” page ¾ Clear Invent ory ¾ “Next” returns to “ R eci pe” page “Setup” Page ¾ Touch the AC S icon and ent er in.
Continuous Loss-in-Weight Blenders Chapter 4: Operation 51 Setting a Recipe - To set a recipe, touch the hopper you want to change, a keypad will pop up, enter the desired percentage for the hopper. Clean Out -Touching the “Clean Out” button will take y ou to the page to manually run the motors.
Continuous Loss-in-Weight Ble nders Chapter 5: Maintenance 52 Chapter 5: Maintenance 5-1 Preventative Maintenance Schedule The mechanical design of the blender is simple and little maintenance is required. The only moving parts are the re-fill valves, optional re grind agitators, meteri ng augers, and optional discharge slide gates.
Continuous Loss-in-Weight Ble nders Chapter 5: Maintenance 53 Note: Other service problems or questions can be answered by contacting the Service Department.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 54 Chapter 6: Appendix 6-1 Spare Parts Typical Blender Parts List # DESCRIPTION 015 060 100 Lid (0.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 55 Annex B Information The following design information is provided for your reference: 1. No modifications are allowed to this equi pment that could alter the CE compliance 2. Ambient temperature: 40 degrees Celsius (104 degrees Fahrenheit) – Maximum 3.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 56 6-2 Addendum (Service Supervisor Information) Caution! After all selections are made: Keep p ressing the “Done” key until the unit returns to the Recipe menu.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 57 Once you access the Engineering Menu you will see the following. This is where you make adjustments to fine t une the blender’s performance. You will need to assess the FIFO page previously mentioned in the manually to decide what changes need to be made.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 58 Feed Factor Filter This filter allows you to set the number of snap shots that the FIFO page looks at to find the average deviation. Making this number bigger will cause the feeder to m ake changes slowly, and decreasing the number will make changes f aster.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 59 Advance PID Options (mass flow setup) Sample Time once in Steady Window for FIFO This is how often the control takes snap shots of the mass flow hopper and enters the num ber in the FIFO table.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 60 PID Integral Constant Works the same as the Gain. Feeder Speed Limits This allows you to set the minimum and maxim u m speed for the motor dr ives as a percentage. The drives are not supposed to be run at less than 8 hertz and should not be run a bove 115 hertz.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 61 Allowed Extruder RPM Change for Steady Flag This is how much the extruder RPM can vary and still be considered steady. With no extruder measurement the control always assumes a steady RPM. Update Time for Prox Method in seconds This is how often the extrud er speed updates from the prox.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 62 Advanced Alarm Options This alarm is for no material flow through a a uger, this could be caused by a blockage stopped motor etc. No Flow Timer This is the amount of time used to measure the bit flow (weight lo ss) through a hopper, to determine if an alarm is warranted.
Continuous Loss-in-Weight Blenders Chapter 6: Appendix 63 6-3 Technical Assistance Parts Department Call toll-free 7 am–5 pm CST 800.423.31 83 or call 262.
Een belangrijk punt na aankoop van elk apparaat Sterling 100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sterling 100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sterling 100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sterling 100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sterling 100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sterling 100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sterling 100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sterling 100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.