© Barco, Inc. June 29, 2005
All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted or stored in a retrieval system without the prior written consent of Barco.
Barco provides this manual “as is” without warranty of any kind, either expressed or implied, including but not limited to the implied warranties or merchantability and fitness for a particular purpose. Barco may make improvements and/or changes to the product(s) and/ or the program(s) described in this publication at any time without notice.
This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information in this publication; these changes are incorporated in new editions of this publication.
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the user will be responsible for correcting any interference.
Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchaser must immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults Barco must be informed immediately in writing of any complaints.
The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning, at latest 30 days after the transfer of risks. In the event of justified notice of compliant, Barco can repair the fault or provide a replacement at its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand a reduction in the purchase price or cancellation of the contract. All other claims, in particular those relating to compensation for direct or indirect damage, and also damage attributed to the operation of software as well as to other services provided by Barco, being a component of the system or independent service, will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence or part of Barco.

If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco, or if the goods are handled incorrectly, in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences not
agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either.
The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer.
Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders. All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufactures.

The general safety information in this summary is for operating personnel.
There are no user-serviceable parts within the unit. Removal of the top cover will expose dangerous voltages. To avoid personal injury, do not remove the top cover. Do not operate the unit without the cover installed.
This product is intended to operate from a power source that will not apply more than 230 volts rms between the supply conductors or between both supply conductor and ground. A protective ground connection by way of grounding conductor in the power cord is essential for safe operation.
This product is grounded through the grounding conductor of the power cord. To avoid electrical shock, plug the power cord into a properly wired receptacle before connecting to the product input or output terminals. A protective-ground connection by way of the grounding conductor in the power cord is essential for safe operation.
Use only the power cord and connector specified for your product. Use only a power cord that is in good condition. Refer cord and connector changes to qualified service personnel.
To avoid fire hazard, use only the fuse having identical type, voltage rating, and current rating characteristics. Refer fuse replacement to qualified service personnel.
To avoid explosion, do not operate this product in an explosive atmosphere.

t^okfkd
Highlights an operating procedure, practice, condition, statement, etc., which, if not strictly observed, could result in injury to or death of personnel.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Le point d´exclamation dans un triangle equilatéral signale à alerter l´utilisateur qu´il y a des instructions d´operation et d´entretien tres importantes dans la litérature qui accompagne l´appareil.
Ein Ausrufungszeichen innerhalb eines gleichwinkeligen Dreiecks dient dazu, den Benutzer auf wichtige Bedienungs-und Wartungsanweisungen in der Dem Great beiliegenden Literatur aufmerksam zu machen.

The table below lists the changes to the 16x16 and 8x8 HD/SD-SDI Router User’s Guide.
Table 0-1. Change History


få=qÜáë=`Ü~éíÉê
This chapter is designed to introduce you to the MatrixPRO™ 16x16 and 8x8 HD/SD-SDI Router User’s Guide.
Areas to be covered are:

`Ü~éíÉê=píêìÅíìêÉ
The following chapters provide instructions for all aspects of MatrixPRO 16x16 and 8x8 HD/SD-SDI Router operations:
Chapter Structure

^Äçìí=íÜÉ=j~íêáñmol
The MatrixPRO 16x16 digital router is available in HD-SDI or SD-SDI versions:
Both versions of the MatrixPRO 16x16 digital router provide 16 inputs and 16 outputs, and allow any input to be routed to any output (or group of outputs). The 8x router provides eight inputs and eight outputs.
MatrixPRO is an ideal switcher to provide professional-quality serial digital video signal routing. The operator can save up to eight "presets" from the front panel, and eight with the MatrixPRO Control GUI. Typical applications include live staging events, corporate boardroom presentations, and educational and training events. Remote control operation is available over RS-232, RS-485 and Ethernet.
To ensure trouble-free operation, please follow all procedures in the Installation and Operation sections of this manual. Refer to Chapter 2, “Hardware Installation” and Chapter 3, “Operation” for details.
Should you have any questions regarding the operation of this unit, please consult the factory. Refer to Appendix C, “Contact Information” section for information.
The MatrixPRO 16x16 digital router includes the following features:
About the MatrixPRO

qÉÅÜåáÅ~ä=aÉëÅêáéíáçå
The MatrixPRO Serial Digital switcher is available in three versions.
The output gain is unity into 75 ohm loads. All video signals are carried on BNCs for the highest signal quality.
A matrix switcher can route any input to any output (or multiple) outputs. The matrix switcher has built in capabilities to group outputs and route a single input to that group.
The router has the ability to switch inputs to outputs during the vertical interval. In practice, this feature will be used to switch synchronous sources. Channel 1 is the source for vertical interval switching. The feature can be enabled or disabled.
The reclocking circuits clean up marginal input signals. There are times when the signal quality is much worse than marginal, but still produces a usable picture. In this case, the reclocking circuits should be disabled because they will be ineffective at improving image quality.
The MatrixPRO 16x and 8x series can be controlled by the front panel, RS-232, RS-485, or Ethernet. The MP Control GUI allows control of the MatrixPRO router from a PC via serial and Ethernet interfaces. Barco Folsom also offers the compact 1RU MatrixPRO Remote Control Panel which provides 16 input and 16 output buttons for simple remote operation of the MatrixPRO router.
The MatrixPRO product line has been specifically designed to work as the front-end switchers for the Encore Presentation System. The Encore Controller communicates with MatrixPRO analog and digital routers over an EtherNet local area network. All Controller commands are processed and issued to the array of routers without the need to specifically program each switcher. Control of each router is essentially "transparent" to the user.
Technical Description

Technical Description

få=qÜáë=`Ü~éíÉê
This chapter provides detailed instructions for installing the MatrixPRO 16x16 and 8x8 HD/ SD-SDI Router hardware.
The following topics are discussed:

p~ÑÉíó=mêÉÅ~ìíáçåë=
For all MatrixPRO 16x16 and 8x8 HD/SD-SDI Router installation procedures, observe the following important safety and handling rules to avoid damage to yourself and the equipment:
Before opening the boxes, inspect them for damage. If you find any damage, notify the shipping carrier immediately for all claims adjustments. As you open each box, compare its contents against the packing slips. If you find any shortages, contact your Barco sales representative.
Once you have removed all the components from their packaging and checked that all the listed components are present, visually inspect each unit to ensure there was no damage during shipping. If there is damage, notify the shipping carrier immediately for all claims adjustments.
The environment in which you install your MatrixPRO 16x16 and 8x8 HD/SD-SDI Routers should be clean, properly lit, free from static, and have adequate power, ventilation, and space for all components.
Safety Precautions

oÉ~ê=m~åÉä=`çååÉÅíçêë
The figures below illustrate the MatrixPRO 16x16 and 8x8 rear panels:

4 6 8 10 12 14 16 2 2 4 6 8 10 12 14 16
Figure 2-1. MatrixPRO 16x16 HD-SDI and SD-SDI Rear Panel

8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8
Figure 2-2. MatrixPRO 8x8 HD-SDI Rear Panel
Rear Panel Connectors

o~ÅâJjçìåí=fåëí~ää~íáçå
MatrixPRO 16x and 8x Digital Router units are designed to be rack mounted.
Please note the following important points:
Rack-Mount Installation

Power Cord/Line Voltage Selection
The MatrixPRO 16x Matrix Switcher performs line voltage selection automatically. No user controls are required for line voltage selection. The AC power cords must be accessible so that the cords can be removed during field servicing.
Figure 2-3. Tandem Prong-type Plug

sáÇÉç=fåéìíLlìíéìí=`çååÉÅíáçåë
The figure below illustrates the input and output connectors on the 16x16 panel:

4 6 8 10 12 14 16 2 2 4 6 8 10 12 14 16
Figure 2-1. MatrixPRO 16x16 Input/Output Connectors
The figure below illustrates the input and output connectors on the 8x8 panel:

8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8
Figure 2-2. MatrixPRO 8x8 Input/Output Connectors
The video input section on the MatrixPRO rear panel provides 16 digital video inputs. Each HD-SDI input accepts serial digital video signals up to 1.485Gb/s. The SD-SDI version accepts serial digital video signals up to 540Mb/s. Connection points for each type of video signal are illustrated above.
Sixteen independently buffered outputs are provided.
Eight independently buffered inputs are provided.
Eight independently buffered outputs are provided.
Video Input/Output Connections

få=qÜáë=`Ü~éíÉê
This chapter provides detailed operating instructions for the MatrixPRO 16x16 and 8x8 HD/ SD-SDI Routers.
The following topics are discussed:

`çåíêçä=lîÉêîáÉï
This portion of the manual outlines how to control all MatrixPRO functions. There are many means to control the unit available to the user.
After plugging in the MatrixPRO to the wall socket, locate the power switch on the back of the chassis, and turn the power ON. The LEDs on the buttons will light, the display will show the Main Menu screen, and the last saved or recalled setup will be recalled.
Control Overview

j~íêáñmol=cêçåí=m~åÉäë
On the MatrixPRO 16x and 8x routers, the front panel allows local control and monitoring of the matrix switcher. The figures below illustrate the MatrixPRO 16x16 and 8x8 front panels:

8 16 7 15 6 14 5 13 4 12 3 11 2 10 1 9
8 16 7 15 6 14 5 13 4 12 3 11 2 10 1 9
Figure 3-1. MatrixPRO 16x16 Front Panel

Figure 3-2. MatrixPRO 8x8 Front Panel

The Menu Display shows all MatrixPRO menus, using a four-line display. Brightness is adjustable.
Use the Selector Knob to scroll through system menus. The cursor (>) always indicates the current line.
MatrixPRO Front Panels

At the right-side of the front panel, the 8x and 16x routers each have a set of eight input selection switches on the top row. On the 16x only, unshifted input buttons access inputs 1-8; shifted buttons access inputs 9-16.
Routing operation resembles the industry standard procedure — select a destination (output), select a source (input) and press TAKE.
Once input and output selections are made, press TAKE to complete a route.
Two buttons are provided for menu navigation. Within the menu structure:
~ Press SEL to enter a menu, change a parameter and accept a parameter. ~ Press ESC to exit a menu without making changes, and to navigate up the menu tree.
Refer to the “Main Menu” section for additional menu navigation instructions.
At the right-side of the front panel, The 8x and 16x routers each have a set of eight output selection switches on the bottom row. On the 16x only, unshifted output buttons access outputs 1-8; shifted buttons access outputs 9-16.
Routing operation resembles the industry standard procedure — select a destination (output), select a source (input) and press TAKE.
On the 16x router only, the two SHIFT keys allows access to inputs 9 through 16, and outputs 9 through 16. When the SHIFT key is pressed for the adjacent row, the button lights to indicate that inputs (or outputs) 9 through 16 can be accessed.
Please continue with the “Menu Structure” section, which describes all menu displays in the MatrixPRO Digital product line.
MatrixPRO Front Panels

jÉåì=píêìÅíìêÉ
This section illustrates and explains all the menus in the MatrixPRO’s menu structure, in the order in which they appear. The following topics are discussed:
Menu Structure

jÉåì=qêÉÉ
The figure below illustrates the MatrixPRO Menu Tree. Use this diagram for reference as you learn the menu structure.
Figure 3-3. MatrixPRO Menu Tree

j~áå=jÉåì
The figure below illustrates the Main Menu, which contains six items. Each of these items contains at least one sub-menu.
> Setup >> Status >> Reclocking >> Vertical Switch >> Save Preset >> Recall Preset >>
Figure 3-4. MatrixPRO Main Menu
Please note the following important rules regarding menu usage:
Each menu is explained in detail below:
Menu Structure

pÉíìé=jÉåì
From the Main Menu, select Setup to display the Setup Menu.
> System >> Factory Reset >> Tech Support >>
Figure 3-5. MatrixPRO Setup Menu
Each menu is explained in detail below:
From the Setup Menu, select System to display the System Menu
> VFD Brightness +10 Serial Mode >> RS-232 Settings >> RS-485 Settings >> IP Address >> System Save >> System Recall >>
Figure 3-6. MatrixPRO System Menu
Each menu is explained in detail below:
Menu Structure

From the System Menu, select VFD Brightness to adjust the vacuum fluorescent display (VFD) brightness. To change brightness:
From the System Menu, select Serial Mode to display the Serial Mode Menu.
> RS-232
Figure 3-7. MatrixPRO Serial Mode Menu
This sub-menu enables you to determine the mode of serial communication. The choices are RS-232 or RS-485. RS-232 signalling is used when there is a direct connection between a control function and the switcher. RS-485 signalling is used when there are many devices attached to a party-line communications ring. Each Node on the party-line is assigned a number for addressing purposes. To determine the mode of serial communication:
From the System Menu, select RS-232 Settings to display the RS-232 Settings Menu.
> Baud Rate 57600 Parameters N81 Handshaking ON Reset
Figure 3-8. MatrixPRO RS-232 Settings Menu
This menu allows control of serial communications parameters for both RS-232 and RS- 485. The parameters listed above show the default settings that result from a Factory Reset, or by issuing a Reset from this menu.
Menu Structure

Please note:
~ N81, (one start bit, eight data bits, one stop bit and no parity bit) ~ E71, (one start bit, seven data bits, one stop bit, even parity) ~ O71, (one start bit, seven data bits, one stop bit, odd parity.) • Hardware handshaking can be set to ON or OFF.
From the System Menu, select RS-485 Settings to display the RS-485 Settings Menu.
> Baud Rate [57600] Handshaking [OFF] Node Number 17
Figure 3-9. MatrixPRO RS-485 Settings Menu
This menu allows the adjustment of the node number in the conventional manner. The node number can range from 1 to 32. After a factory reset or an RS-232 menu reset, the default node number is set to 17.
From the System Menu, select IP Address to display the IP Address Menu.
192.168.000.242 ^
Figure 3-10. MatrixPRO IP Address Menu
When this menu item is selected, the cursor (^) will be positioned under the right-most digit in the address. Note that the default IP address is 192.168.000.242. To adjust the IP address:
Menu Structure

From the System Menu, select System Save to save all settings except routing. When pressed, the menu briefly displays “Saving.”
From the System Menu, select System Recall to recall all settings except routing. When pressed, the menu briefly displays “Recall.”
From the Setup Menu, select Factory Reset to display the Factory Reset Menu.
<SEL> = Yes <ESC> = No
Figure 3-11. MatrixPRO Factory Reset Menu
The user must make a deliberate decision to perform a factory reset. When this function is performed, the following conditions will take effect:
Menu Structure

qÉÅÜ=pìééçêí=jÉåì
From the Setup Menu, select Tech Support to display the Tech Support Menu.
Version 2.10.09 Phone 866-374-7878
Figure 3-12. MatrixPRO Tech Support Menu
The Tech Support Menu shows the installed version of software, as well as the phone number for factory support. During the week, technical help is available on the toll-free line from 8:00 AM to 6:00 PM, West Coast time.
From the Main Menu, select Status to display the Input/Output Status Menu, as illustrated below.
Figure 3-13. MatrixPRO Input/Output Status Menu (sample)
This menu shows the current assignments of inputs to outputs. The 16x router can route any input to any of 16 outputs. Please note:
Menu Structure

oÉÅäçÅâáåÖ=jÉåì
From the Main Menu, select Reclocking to display the Reclocking Control Menu, as illustrated below.
> Output 1 Enabled Output 2 Disabled Output 15 Enabled Output 16 Disabled
Figure 3-14. MatrixPRO Reclocking Control Menu
The system’s reclocking circuits clean up marginal input signals. There are times when the signal quality is much worse than marginal, but still produces a usable picture. In this case, the reclocking circuits should be disabled, because they will be ineffective at improving image quality. To enable or disable reclocking:
All channels of reclocking are set to "enabled" during a factory reset.
Menu Structure

sÉêíáÅ~ä=fåíÉêî~ä=pïáíÅÜáåÖ=jÉåì
From the Main Menu, select Vertical Switch to display the Vertical Interval Switching Menu, as illustrated below.
> Function Enabled Source [Ch. 1] SYNC [Valid]
Figure 3-15. MatrixPRO Vertical Interval Switching Menu
The source for vertical SYNC is hard-set to the channel 1 input. The only function that the user can control is to enable or disable the vertical interval switching. This function can be enabled and disabled in the same manner as the reclocking function.
Status will report a unacceptable or absent input signal as "Invalid," and report an acceptable signal as "Valid." The status of input SYNC will always be reported whether or not the function is enabled.
From the Main Menu, select Save to display the Save Presets Menu, as illustrated below.
> File 1
Figure 3-16. MatrixPRO Save Presets Menu
There are eight machine configuration presets that can be saved. To save presets:
Menu Structure

oÉÅ~ää=mêÉëÉíë=jÉåì
From the Main Menu, select Recall to display the Recall Presets Menu, as illustrated below.
> File 1
Figure 3-17. MatrixPRO Recall Presets Menu
There are eight video signal configuration presets that can be recalled. To recall presets:
Menu Structure

Control of Digital Video Switching
Use the following steps to perform a switch:

Establishing Groups of Inputs and Outputs
The MatrixPRO routers can be set up to "lock-out" input sources that are incompatible with certain output display devices.
S Example: Input channels 1, 2 and 3 are SD-SDI sources and output channels 1, 2 and 3 are SD-SDI display devices. Input channels 4, 5 and 6 are HD-SDI sources and outputs 4, 5 and 6 are HD-SDI display devices.
Establishing groups like these prevents an input from Group 2 from being accidentally switched to a Group 1 output.
There are two methods available for grouping inputs and outputs:
Use the following steps to create an input/output group manually:
S Prerequisites: Assume that input channel 1 is routed to output channel 1. No other inputs are assigned to any output.
When an input/output group has been established, it has the following characteristics:

Establishing Groups of Inputs and Outputs
Use the following steps to remove a member of an input/output group:
Please note:

få=qÜáë=`Ü~éíÉê
This chapter describes the installation and operation of the MatrixPRO interactive Control GUI. The following topics are discussed:

`çåíêçä=drf=fåëí~ää~íáçå
The MatrixPRO Control GUI is an interactive Graphical User Interface application designed to assist users with MatrixPRO operation. There are two ways to obtain the software:
The following step-by-step instructions will allow you to install Barco Folsom MatrixPRO Control GUI in a Windows NT/2000/XP PC. Use the figures provided as a visual reference during the installation process. Use the following steps to install the MatrixPRO control software:

Figure 4-1. Welcome Dialog
Control GUI Installation


Figure 4-2. Choose Destination Dialog
The default install directory is C:\Folsom Research\MatrixPRO\MPControl.
~ Click Browse to select a different directory, if desired.

Figure 4-3. Start Installation Dialog
The setup application is now ready to install the MP Control application.
Control GUI Installation


Figure 4-4. Installation Complete Dialog
Please note:
Start > Programs > Folsom Research > MPControl
Control GUI Installation

bèìáéãÉåí=pÉíìé
Use the following steps to set up equipment:
Use the following steps to control the MatrixPRO using a computer on the same LAN:
Please note the following important points:
Equipment Setup

drf=léÉê~íáçå
As with all Barco Folsom products, if the hardware is populated or functionality is enabled, the control "keys" will be labelled in black. If channels of hardware are not populated, the "key" labels will be grayed out.
S Example: In the case of a 8x8 router, input channels 9 through 16, and output channels 9 through 16 will be grayed-out.
The following topics are discussed in this section:
GUI Operation

sáÇÉç=pïáíÅÜáåÖ=q~Ä
Use the following steps to utilize the Video Switching Tab:

Figure 4-5. Video Switching Tab (sample)
~ On the front panel of the MatrixPRO, the Output channel will be steadily illuminated while the Input key will start blinking. This also is an indication that a route is pending.
~ The Video Switching page mimics the MatrixPRO front panel — in that the user must click on a given input channel "key" in order to see the type
GUI Operation

of the assigned output route, but the Input channel assigned to that particular Output channel can be read in the green box.
The complete MatrixPRO configuration can be saved as a "preset." Please note:
~ The input channel assignment boxes light up in red, indicating that a route is pending. ~ The input channel assignments are those of Preset 2, (input 1 to output 2, etc.).
At the top of the GUI page, there are three pull-down menus:
GUI Operation

i~ÄÉäáåÖ=q~Ä
Click the Labeling Tab on the MatrixPRO Control application. A sample tab is shown below:

Figure 4-6. Labeling Tab (sample)
This tab allows the user to assign a name to any input and output channel. The names will appear throughout the GUI pages, as an aid to the user. There is a limit of 5 capitalized characters per label. These can be either letters or numbers, or a mixture of both.
GUI Operation

dêçìéáåÖ=q~Ä
Click the Grouping Tab on the MatrixPRO Control application. A sample tab is shown below:

Figure 4-7. Grouping Tab (sample)
The MatrixPRO routers can be set up to "lock-out" input sources that are incompatible with certain output display devices.
S Example: Input channels 1, 2 and 3 are all SD-SDI sources, and output channels 1, 2 and 3 are SD-SDI display devices. Input channels 4, 5 and 6 are HD-SDI sources and output channels 4, 5 and 6 are HD-SDI devices.
Establishing groups like these prevents an input from Group 2 from being accidentally switched to a Group 1 output. The type of route and the input source must still be established using the Video Switching page. Use the following steps to establish a group:
GUI Operation

The Front Panel buttons will show the members of a Group:
GUI Operation

pÉèìÉåÅáåÖ=q~Ä
Click the Sequencing Tab on the MatrixPRO Control application. A sample tab is shown below:

Figure 4-8. Sequencing Tab (sample)
The Sequencing Tab enables you to cycle through a sequence of presets. This functionality also allows for a variable "dwell time," in seconds, during which the currently selected preset is applied to the router. Dwell time ranges from 1 to 1000 seconds. and the default dwell time is 3 seconds. Please note:
GUI Operation

Use the following steps to perform a sample sequence:
GUI Operation

pÉíìé=q~Ä
Click the Setup Tab on the MatrixPRO Control application. A sample tab is shown below:

Figure 4-9. Setup Tab (sample)
The Setup Tab allows the user to select the method of MatrixPRO remote control, either RS-232 or EtherNet. Please note:
GUI Operation

qÜÉ=?^Äçìí?=q~Ä
Click the About Tab on the MatrixPRO Control application. A sample tab is shown below:

Figure 4-10. About Tab (sample)
This page shows the current GUI software revision as well as the firmware revision running on the MatrixPRO hardware. This page also contains the RS-232 dialog box.
Commands can be issued from this dialog box, and MatrixPRO will respond according to the serial command structure document. The user must position the mouse cursor inside the dialog box and make one click in order to issue commands to the MatrixPRO.
Serial activity indicators are located underneath the dialog box to aid in serial communication debugging.
GUI Operation

GUI Operation

få=qÜáë=`Ü~éíÉê
This chapter provides system connectivity information. The following topics are discussed:

`çååÉÅíáîáíó=aá~Öê~ã
The figure below provides a sample connectivity diagram:

Figure 5-1. MatrixPRO Connectivity Diagram (sample)
At Barco Folsom, we take pride in offering unique solutions to demanding technical problems. If you have questions, require further information or would like to discuss your application requirements in more detail, please call (916) 859-2500. Our Customer Support Engineers will be happy to supply you with the support you need.
Connectivity Diagram

få=qÜáë=`Ü~éíÉê
This chapter provides detailed instructions for upgrading system software components.
The following topics are discussed:

lîÉêîáÉï
The MatrixPRO units built by Barco Folsom incorporate system software in a Flash memory component. Flash memory allows easy software upgrades, without the need to send the unit back to the factory.
The “loader” utility enables you to update the system’s Flash module with the latest revision of software. The utility can be run from a computer with a hard drive (recommended) or a floppy drive. Running the loader from a floppy drive is discouraged due to the slow speeds associated with disk access.
The following list outlines hardware requirements for upgrading software:
The following list outlines software requirements for upgrading software:
The Flash File Loader with the Software files can be downloaded from our FTP site as described below.
Overview

Connecting to Barco Folsom
ftp://ftp.folsom.com • If you are using a web browser to access our web site, point the browser to:
MatrixPRO Software Files and Flash File Loader
Directory Location:
File to download:
Use the following steps to install MatrixPRO software files and the Flash File loader:

Preparing to Upgrade the MatrixPRO
Use the following steps to prepare to upgrade the MatrixPRO 16x and 8x:
Use the following steps to start the Flash File utility:
~ If nothing occurs when ENTER is pressed, it is possible that serial port communication was not established. ~ If this is true, click on the RS232 Config Menu and select the COM Port to which the unit is connected. ~ In the CONFIG SERIAL sub-menu, verify the following:

Uploading Files to MatrixPRO
Use the following steps to upload files to the MatrixPRO system:

Uploading Files to MatrixPRO

få=qÜáë=^ééÉåÇáñ
This appendix provides detailed technical specifications for the MatrixPRO 16x16 and 8x8 HD/SD-SDI Router.
The following topics are provided:

paf=péÉÅáÑáÅ~íáçåë=
The table below lists MatrixPRO SDI specifications.
Table A-1. MatrixPRO SDI Specifications
Video Input Number/signal type 16 Unbalanced serial data
Signal Type SMPTE 259M compliant
Signal Speeds 143, 177, 270, 360 Mbps
Return loss -15dB @ 270 MHz
Maximum Cable Length 350m at 270Mbps using Belden 1694A cable
Video Output Number/signal type 16 Unbalanced serial data
Signal Type SMPTE 259M compliant
Return loss -15dB @ 270 MHz
Output Jitter with reclocker enabled (max)
0.2 U.I (Alignment), 1.0 U.I (Timing) per SMPTE specifications
Switching type Vertical interval per SMPTE specs - input channel 1 reference

eaLpaf=péÉÅáÑáÅ~íáçåë=
The table below lists MatrixPRO HD/SDI specifications.
Table A-2. MatrixPRO HD/SDI Specifications
Video Input Number/signal type 16 Unbalanced serial data
Signal Type SMPTE 292M and SMPTE 259M compliant
Signal Speeds 143, 177, 270, 360, 1483.5, 1485 Mbps
Return loss -15dB @ 1.485 GHz
Maximum Cable Length 350m at 270 Mbps, 140m @ 1.485 Gbps using Belden 1694A cable
Video Output Number/signal type 16 Unbalanced serial data
Signal Type SMPTE 292M and SMPTE 259M compliant
Return loss -15dB @ 1.485 GHz
Output Jitter with reclocker enabled (max)
0.2 U.I (Alignment), 1.0 U.I (Timing) per SMPTE specifications
Switching type Vertical interval per SMPTE specs - input channel 1 reference

`çããçå=péÉÅáÑáÅ~íáçåë=
The table below lists common MatrixPRO specifications.
Table A-3. MatrixPRO Common Specifications
VREF Sync Input Source Channel 1 Input
Control/Remote Serial control port RS-232 / RS-485, 25-pin female D connector
Baud rate and protocol 57600, 8-bit, 1 stop bit, no parity, (selectable)
Ethernet control port 1 RJ-45 female connector
Ethernet data rate 10/100Base-T, half/full duplex with autodetect
Ethernet protocol ARP, ICMP (ping), TCP/IP, Telnet
Power Type 100-240 VAC, 47-63 Hz, auto-configuring
Connector IEC connector with integrated fuse and switch
Power Dissipation 35 watts
Enclosure Dimensions 3.5" H x 17.0" W x 15" D
8.9cm H x 43.2cm W x 38.1cm D
Weight 17 lbs (7.6 kg)
Shipping weight 22 lbs (10 kg)
Rack mount Yes, with included parts
Environmental Temperature 0-40 degrees C
EN55022:1998 Class A and EN550024:1998

få=qÜáë=^ééÉåÇáñ
This appendix provides information regarding external remote control protocol. The following topics are discussed:

aÉÑ~ìäí=pÉêá~ä=m~ê~ãÉíÉêë
The following are the parameter settings for serial communication:
Default Serial Parameters

RS-232/485 Remote Control Connections
The RS-232 or RS-485 serial port can be connected to a computer to support remote control of the MatrixPRO unit. The Electronics Industry Association (EIA) has produced standards for RS-232 and RS-485 that describe serial data communications.
Figure B-1. Remote Port Connector, DB-25
Below is the pinout for both RS-232 and RS-485 with the DB-25 connector:
Table B-1. RS-232 and RS-485 Pinouts
4 RTS N/A
5 CTS N/A
6 DSR N/A
7 Sig Gnd Sig Gnd
10 N/A N/A
12 N/A N/A
14 N/A T(+)
15 N/A N/A
16 N/A R(+)
19 N/A N/A
20 DTR N/A
21-25 N/A N/A
1 Shield Shield · 2 TxD T(-) · 3 RxD R(-)

opJOPO=jçÇÉ
The MatrixPRO will respond with a “#” prompt when the command processor is ready for a command. The command syntax is shown below
cmd arg1 arg2 … argn
Table B-2. RS-232 Command Syntax
cmd cmd is any valid MatrixPRO command, typically 2 to 6 alphabetic (non numeric) characters
arg argument1, argument2, … argument"N" are required or optional parameters depending on the command used.
carriage return (ASCII 13) terminates the command
Please note:
The “=” indicates that a result from a query command is following. The “result” will follow directly after the “=”. The value of the result will vary depending on the query command used. A new line will be generated and the prompt (#) will indicate the system is ready for a new command.

opJQUR=jçÇÉ
To switch to RS-485, refer to the “RS-232 Settings Menu” section in Chapter 3. Single commands will be combined with a command delimiter start, device number, command separator and command delimiter end to form a command string as shown below:
cdsidcmd arg1 arg2 ..argn,idcmd arg1 arg2 ..argN,…,idcmd arg1 arg2 ..argncde
Table B-3. RS-485 Command Syntax
cds cds is the command delimiter start character '*' (ASCII 42).
id id is the device number in the range of 1 to 32. This can be a single character for values less than 10, no preceding zero is required.
cmd cmd is any valid Graphics Board command, typically 2 to 6 characters in length
arg arg1,2,N is any required or optional parameters need for the command
, separates multiple commands
cde cde is the command delimiter end character '!' (ASCII 33).
S Example:
The command string is started by the command delimiter start character “*”. The first command follows directly after the command delimiter start character. The example shows that device 12 should process the XYZ command with A and 9 as parameters. A comma (ASCII 44) separates the commands. Device 9 will process the PDQY command with a parameter of 1234 and device 31 will process the WX command with parameters of 200 and 98. The command end delimiter character “!” follows directly after the last command to end the command string.
Commands received in the command string will not be processed until the command end delimiter character “!” is received. This format allows commands to be stacked up for transmission to a single device or multiple devices and executed when the cde “!” character is received by all units. Any incomplete or unknown commands will be ignored. The maximum number of commands that can be stacked up per unit is 16. Each unit will only stack those commands assigned to it, even though all units receive the same command string.
During queue processing, no input buffer processing is performed. Characters sent through the serial port during queue processing are still stored in the input buffer. If hardware flow control is not observed, it is important to guarantee that the input buffer limit
RS-485 Mode · Command Description

is not exceeded before completion of the last command string.
To minimize bus traffic the command words should be kept as short as possible. The units will not respond with prompts or any command error conditions. Echo mode will be disabled when RS-485 mode is selected.
RS-485 Mode

j~íêáñmol=oÉãçíÉ=`çãã~åÇë
The table below lists MatrixPRO remote commands. Click the hyperlink for detailed descriptions and examples.
Table B-4. MatrixPRO Remote Commands
HELP Capabilities. Send complete list of commands available in ASCII format
CLEAR Clear all matrix video routings
CSUMSTAT Display Main Code/RBF Checksum info
FPLOCK en Locks/unlocks Front Panel control
GADD grp out in Add an output or input to group
GCLEAR grp Clears grouping information
GDEL grp out in Remove output, input from group
IPCONFIG I3 I2 I1 I0 IP address configuration I3.I2.I1.I0
ISTAT num Input video status
LOADRMP Places unit into loader mode for firmware upgrade
OBLNK out blnk Displays output channel status
OSTAT Displays output status in ASCII
PRST num Saves current front panel configuration to a Preset location
PSTAT Displays preset status in ASCII
RCLKEN num en Enables/Disables individual output reclockers
RESETMP op Reset MatrixPRO, recall saved Flash values op [R|F] Reset|Factory Reset
RNOV Recall Flash settings
RPRST num Recall preset from a Preset location
RTEMP out in Route inputs to outputs. If output is in group, group is routed too
SBAUD mode Sets Baud Rate. 0=19200, 1=28800, 2=38400, 3=57600
SMODE mode [485id] Serial Mode. 0=RS232, 1=RS485. [485id] opt if RS232
SWITCH mode Switching Mode. 0 = (Vertical Interval Switching Off), 1 = On
TAKE en en = 1 simulates a TAKE button pushed on the front panel (i.e takes all preliminary routes and makes them permanent). en = 0 simulates a CANCEL button pushed
UNOV Save current settings to FLASH
MatrixPRO Remote Commands · Command Description

j~íêáñmol=pÉêá~ä=`çãã~åÇ=iáëíLaÉëÅêáéíáçå
grp Group number to add output; [1-16]
out Output number to add; [1-16] / 101 if no output to add
in Input number to add; [1-16] / 101 if no input to add S Examples:
GADD 1 4 2 (Add output 4 and input 2 to group 1.)
GADD 1 101 5 (Add input 5 to group 1.)
MatrixPRO Remote Commands

grp Group number to clear; [1-16] S Example: GCLEAR 1 (Clears the grouping information in group number 1.)
grp Group number to remove output; [1-16]
out Output number to remove; [1-16] / 101 if no output to remove
in Input number to remove; [1-16] / 101 if no input to remove S Examples:
GDEL 1 4 2 (Remove output 4 and input 2 from group 1.)
GDEL 1 101 5 (Remove input 5 from group 1.)
I3 First set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I2 Second set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I1 Third set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255]
I0 Fourth set of IP numbers for Ipv4 (I3.I2.I1.I0); [0-255] • Query: IPCONFIG? Returns the current IP address the MatrixPRO is set to in the format:
num Input number; [1 - 16]
Returns [1] for good video present
Returns [0] for bad or absent video signal. S Example: ISTAT 1 Queries status input one. Returns 1 for good video
MatrixPRO Remote Commands

out Output number; [1 - 16]
blnk Blanking status; [0|1], Disable|Enable • Query: OBLNK? out Returns the selected output blanking status in the format:
out Output number; [1 - 16]
S Examples:
OSTAT 1 (Displays output status for output 1.)
OSTAT (Displays output status for all outputs.)
out Preset number to save to; [1 - 16] S Example: PRST 1 (Saves configuration to preset location 1.)
MatrixPRO Remote Commands

out Preset number; [1 - 16]
S Examples:
PSTAT 1 (Displays preset status for preset 1.)
PSTAT (Displays preset status for all presets.)
num Input number; [1 - 16]
en Enable -[1]; Disable - [0] • Query: RCLKEN? num; Returns the selected output's Reclocker Status: =en S Example: RCLKEN 10 1 (Enables output 10 Reclocker)
op Reset operation; [R|F], Restart|Factory S Example: RESETMP F (Resets system to factory defaults and resets all user saved presets.)
out Preset number to recall from; [1 - 16] S Example: RPRST 1 (Recalls configuration from preset location 1.)
MatrixPRO Remote Commands

out Output number; [1 - 16]
in Video Input number to route video; [1-16] / 101 if no input to add / 0 unroutes input • Query: RTEMP? out; Returns the current video inputs routed to the specified output in the format: =in S Examples:
RTEMP 1 3 (Route to output 1, video input 3.)
RTEMP 4 101 (Route to output 4.)
mode Mode; [0|1|2|3], 19200|28800|38400|57600 • Query: SBAUD? Returns the current serial baud in the format: =mode S Example: SBAUD 0 (Sets Serial baud rate to 19200.)
mode Mode; [0|1], RS-232|RS-485
485id RS-485 ID for the MatrixPRO. This field is ignored if switching to RS-232 mode. • Query: SMODE? Returns the current serial mode in the format: =mode 485id S Examples:
SMODE 0 (Sets Serial mode for RS-232.)
SMODE 1 10 (Sets Serial mode for RS-485 with ID 10)
mode Mode; [0|1], Off|On • Query: SWITCH? Returns current video switching mode in the format: =mode S Example: SWITCH 0 (Turns vertical interval switching off.)
MatrixPRO Remote Commands

en Mode; [0|1], Cancel all pending|Route all pending.
MatrixPRO Remote Commands

MatrixPRO Remote Commands

få=qÜáë=^ééÉåÇáñ
The following topics are discussed in this Appendix:
All video products are designed and tested to the highest quality standards and are backed by a full 3-year parts and labor warranty. Warranties are effective upon delivery date to customer and are non-transferable. Barco warranties are only valid to the original purchaser/owner. Warranty related repairs include parts and labor, but do not include faults resulting from user negligence, special modifications, lightning strikes, abuse (drop/crush), and/or other unusual damages.
The customer shall pay shipping charges when unit is returned for repair. Barco will cover shipping charges for return shipments to customers.
In the unlikely event that a product is required to return for repair, please call the following number and ask for a Sales Engineer to receive a Return Merchandise Authorization number (RMA).
RMA Conditions are listed below:
a. Prior to returning any item, you must receive a Return Merchandise Authorization (RMA) number.
b. All RMA numbers must appear on their return-shipping label.
c. RMA numbers are valid for ten (10) days from issue date.
d. All shipping and insurance charges on all RMAs must be prepaid by the
customer

Barco Events Contact Information
Barco Events USA/Barco Folsom, LLC
Barco N.V
Sales Contact Information · Technical Support Information

e
Double-cursor 19 Downloading files, software upgrade 51
handshaking 22 installation 7 requirements, upgrading software 50 HD-SDI
Encore Presentation System 5 Equipment
architecture 4 specifications 57 HELP 66 History, change vi How to
marking terms v setup 35 ESC 16, 19 Ethernet
connector 9 control 4 remote setup 35 socket 35
adjust IP address 22 control MatrixPRO on LAN 35 create input/output group manually 29 determine mode of serial communication .21 enable/disable reclocking 25 establish a group via GUI 40 install MatrixPRO control software 32 install MatrixPRO software files 51 perform a sample sequence 43 perform a switch 28 power up MatrixPRO 14 prepare to upgrade MatrixPRO 52 recall presets 27 remove member of input/output group . . .30 save presets 26 set up equipment 35 set up sample presets 38 start Flash File utility 52 upload files to MatrixPRO 53 use menu system 19 use this guide 3 use video switching tab 37 Hyperlinks 3
Factory Reset menu 23 FCC statement ii Features, MatrixPRO 4 File pull-down menu 38 Flash File
loader 51 utility 52 FPLOCK 66 Front panel 15
lockout key 44 lockout mode 4 FTP
server 32 site address 51
f
GADD 66 GCLEAR 67 GDEL 67 Graphical User Interface, grouping 29 Grouping tab 40 Groups of inputs and outputs 29 Guarantee and compensation ii GUI 4
I/O Grouping 4 Input
connections 12 crosspoint selection buttons 16 Input/Output
assignments, current 24 group, characteristics 29 groups 29 Inspection 8 Installation
current software revision 45 grouping 29 installation 32 installation and operation 31 operation 36
complete dialog 34 GUI 31, 32 hardware 7 rack mount 10 safety precautions 8 site preparation 8 unpacking and inspection 8
Hardware

Installed version of software 24 Introduction to MatrixPRO 1 IP address
tree 18 usage, rules 19 vertical interval switching 26 VFD brightness 21 MPControlSetup.exe 32
default 44 menu 22 IPCONFIG 67 ISTAT 67
Labeling tab 39 LAN control 35 LOADRMP 68
OBLNK 68 Operation
GUI 31, 36 MatrixPRO 13 Operators safety summary iv OSTAT 68 Output
Main Menu 19 Manual grouping 29 MatrixPRO
about 4 control application . . .35, 39, 40, 42, 44, 45 control overview 14 features 4 front panel 15 hardware installation 7 introduction to 1 operation 13 rear panel 12 rear panel connectors 9 remote commands 65 remote control protocol 59 specifications 55 technical description 5 upgrading software 49 uploading files 53 versions 4 Memory Presets 4 Menu
connections 12 crosspoint selection buttons 16 Overview
control 14 upgrading software 50
PDF file usage 3
navigating and searching 3 Pinout, RS-232, RS-485 connector 61 Power
cord, line voltage selection 11 up and initialization 14 Preset save and recall 38 Protocol, remote control 59 PRST 68 PSTAT 69
display 15 factory reset 23 IP address 22 main 19 navigation buttons 16 recall presets 27 reclocking control 25 RS-232 settings 21 RS-485 settings 22 save presets 26 serial mode 21 setup 20 status 24 structure 17 system 20 tech support 24
Rack mount installation 10 RCLKEN 69 Rear panel 12
connectors 9 Recall
preset 38 presets menu 27 system 23

Reclockers 4 Reclocking Control Menu 25 Remote
HELP 66 IPCONFIG 67 ISTAT 67 LOADRMP 68 OBLNK 68 OSTAT 68 PRST 68 PSTAT 69 RCLKEN 69 RESETMP 69 RNOV 69 RPRST 69 RTEMP 70 SBAUD 70 SMODE 70 SWITCH 70 TAKE 71 UNOV 71 Setup
commands, MatrixPRO 65 connections 61 Ethernet setup 35 Remote control
panel 4 protocol 59 RESETMP 69 Return material authorization 73 RMA 73 RNOV 69 RPRST 69 RS-232
command Syntax 62 mode 62 remote connections 61 settings menu 21 signalling 21 RS-485
menu 20 remote Ethernet 35 tab 44 SHIFT 28
command syntax 63 mode 63 remote connections 61 settings menu 22 signalling 21 RTEMP 70
buttons 16 Site preparation 8 SMODE 70 Software
flash file loader 51 installed version 24 requirements, upgrading 50 upgrade overview 50 upgrade, downloading files 51 upgrading 49 Specifications 55
precautions 8 summary iv Save
common 58 HD/SDI 57 SDI 56 Start Installation Dialog 33 Status menu 24 Structure, menu system 17 SWITCH 70 Switching, control of 28 Symbols 3 System
preset 38 presets menu 26 system 23 SBAUD 70 Scan convert 48 SDI specifications 56 SD-SDI architecture 4 SEL 16, 19 Selector Knob 15 Sequencing tab 42 Serial
connectivity 47 menu 20 recall 23 save 23
command list 66 mode menu 21 parameters 60 port pull-down menu 38 Serial command
CLEAR 66 CSUMSTAT 66 FPLOCK 66 GADD 66 GCLEAR 67 GDEL 67
about 45 grouping 40 labeling 39 sequencing 42
Safety · Tab

setup 44 video switching 37 TAKE
button 16 serial command 71 Take 28 Tech Support Menu 24 Technical
description, MatrixPRO 5 Terms, equipment marking v Trademarks iii
UNOV 71 Unpacking 8 Upgrading software 49 Uploading files to MatrixPRO 53
Versions of MatrixPRO 4 Vertical interval switching 4
menu 26 Vertical SYNC 26 VFD Brightness Menu 21 Video
input connectors 12 input/output connections 12 output connectors 12 switching tab 37 Voltage selection 11
Warranty 73

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.