PM229 - Issue 3 (November 2008) Brunel 1A/2CB/3CB Free Standing Stove M ODELS: 7008/7008BL/7008LG/7051/7051BL/7051LG/7053/7053BL/7053LG Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland).
COVERING THE FOLLOWING MODELS: 7008/7008BL/7008LG/7051/7051BL/7051LG/7053/7053BL/7053LG 2 COMMISSIONING 22 MAINTENANCE & SERVICING 23 Annual Service 23 Removal of Log Guard 24 Removal of Fire Bric.
3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Dealer appliance was purchased from Name: .............................................................................................
4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance.
5 USER INSTRUCTIONS Airwash Closed Open Primary Air Open Closed Secondary Combustion Control (not 1A) Closed Open PR7225a DOOR HANDLE 1.12 Use a protective gloved hand to operate.
6 USER INSTRUCTIONS 3.2 Solid fuel: •Burn only anthracite or manufactured briquette smokeless fuels listed as suitable for use with closed heating appliances Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this will invalidate the product guarantee .
7 USER INSTRUCTIONS •Rake the embers evenly over the fire bed and open the Airwash control fully for a few minutes before re-fuelling 5.2 Burn new logs at high output for a few minutes before adjusting the Airwash control .
8 USER INSTRUCTIONS 5.11 You must burn only anthracite or smokeless fuels suitable for use in closed appliances . 5.12 Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this invalidates the product guarantee . Do not load fuel above the log guard and the secondary combustion inlets at the back of the firebox.
9 7. ASH REMOVAL 7.1 All fuels: •Open Doors, See Diagram 11 AR2142 •Riddle, See Diagram 12 Riddling Mechanism •Remove Ashpan carefully.
10 13.2 The chimney, any connecting flue pipe and the appliance flue ways if incorporated, must be regularly cleaned. 13.3 Ensure adequate access to cleaning doors where it is not possible to sweep through the chimney.
11 USER INSTRUCTIONS 15. SEASONAL USE 15.1 Clean and service the appliance if it is not used during the warmer periods of the year as detailed in the Maintenance and Servicing section 15.2 Set the air controls 50% open to keep the appliance ventilated and stop the build-up of any moisture inside.
12 TECHNICAL SPECIFICATION Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG Nominal Heat Output Wood kW 4.0 4.0 1.25 0.05 3.3 3.4 396 369 125 5 6.0 6.0 1.25 0.05 5.5 5.8 360 360 150 6 7.0 7.0 1.25 0.
13 BRUNEL DIMENSIONS Description Brunel 1a Brunel 2CB Brunel 3CB Model 7008 7008BL 7008LG 7051 7051BL 7051LG 7053 7053BL 7053LG A 525 640 685 385 437 550 290 335 330 106 115 115 430 545 588 125 125 150 89 122 155 95 103 103 B C D E F (dia) G H All dimensions in mm.
14 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks.
15 2.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in diagram. 2.2 The building must have a suitable load-bearing capacity for the hearth and appliance. •Consult a structural engineer for advice before proceeding 2.
16 SITE REQUIREMENTS WALLS NEXT TO HEARTHS Solid, non-combustible material e.g. masonry or concrete Thickness W C 150mm minimum 150mm minimum C H PR7227 Position of Appliance & Hearth in relation .
17 PRE-INSTALLATION CHECKS Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG Flue/Chimney size Flue/Chimney Minimum Height* Without Liner System Roun.
18 PRE-INSTALLATION CHECKS 3. VENTILATION 3.1 This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm 2 per kW of appliance rated output above 5kW.
19 LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations* and standards**, along with any local regulations and working practices that may apply.
20 INSTALLATION INSTRUCTIONS The Flue must be installed in accordance with manufacturers instructions. Seal Collar with Fire Cement Self Tapping Screw Tee Size Stovax Part No. 5" 4516 6" (4616)* Cap PR7228 PR7229 600mm min 1000mm max unsupported Elbow with access cover Size Stovax Part No.
21 INSTALLATION INSTRUCTIONS 3.3 Take care when handling, as bricks can become fragile after use. Life span depends on the type of fuels burnt and the level of use.
22 COMMISSIONING 1.1 To commission: • Replace the firebricks, baffle, and log retainer • Check the door alignment and catch operation, adjust if required, see Installation Section 6. Adjusting Door hinges • Check the soundness of door seals, castings and joints •C heck the operation of the air controls 1.
23 MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Stovax or call 01392 474011 1. ANNUAL SERVICE 1.1 At the end of the heating season strip, inspect and clean.
24 1.4 Using the appliance for the first time: • Burn at a low output for the first day of use This allows the seals, fixing glues and paint to fully cure. 1.5 During this time the appliance may give off some unpleasant odours: •Keep the room well ventilated to avoid a build-up of fumes.
25 BASIC SPARE PARTS LIST BRUNEL 1A BRUNEL 2CB BRUNEL 3CB BRUNEL 1A 1 2 3 4 5 6 7 8 9 10 12 13 11 Diagram No. Description Part No. 1 BafePlate BR24 2 Side Firebrick BR29 3 Glass Panel Clip BR43 .
26 NOTES.
SERVICE RECORDS 27 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
28.
29.
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.
Een belangrijk punt na aankoop van elk apparaat Stovax 7053lG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Stovax 7053lG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Stovax 7053lG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Stovax 7053lG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Stovax 7053lG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Stovax 7053lG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Stovax 7053lG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Stovax 7053lG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.