36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 700,032M REV . B 05/2006 MODELS UNIVERSAL VENT -FREE FIREBOX Due to high temperatures, the appliance should be located out of traffi c and away from furniture or draperies.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 2 IMPORT ANT SAFETY INFORMA TION INST ALLER: PLEASE LEA VE THESE INSTRUC- TIONS WITH THE OWNER. OWNER: PLEASE RET AIN THESE INSTRUC- TIONS FOR FUTURE REFERENCE.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 3 Misc. Codes / Standards - The Installation must conform to local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 4 Y our options are: a. Rework equations adding the space of adjoin- ing room(s). If the extra volume provides an unconfi ned space, then remove door or add ventilation grills between rooms. Refer to National Fuel Gas Code, ANSI Z223.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 5 Note: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 40" 16" Optional Hearth Extension Fireplace Opening Top Stand- Off Spacer (on appliance) Top of Appliance Finished Wall Header Shown with Canopy Installed (required on UVF-36 only) Non-Combustible Material 3" Min.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 7 Noncombustible material (minimum requirements) with wood mantel or other combustible projections: T o install the fi rebox with a wood mantel, shelf or other combustible projection above fi rebox opening.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 8 Consult all local codes. Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFP A 54 - latest edition (USA) or B149 - latest edition (Canada).
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. Figure 7 8d Nail Top Spacer 9 The fi rebox may be positioned and then the framing built around it, or the framing may be constructed and the fi rebox positioned into the opening. Usually , no special fl oor support is needed for the fi rebox, however , to be certain: 1.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 10 Figure 8 SPECIFICA TIONS Gas Line Access - Both Sides Access Opening for Junction Box - Right Side Only (remove the knock-out before installing J-Box). J-Box / Electrical Kit is not provided with appliance.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. A B 11 FRAMING SPECIFICA TIONS Figure 9 Canopy Kit Installation (see ordering information on Page 16 ) NOTE: A canopy comes standard and is required for model U VF-36.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 12 OPTIONAL EQUIPMENT Blower Kits The FBK-100 Blower Kits are used when a wall-mounted ON/OFF blower switch is desired, and the FBK-200 Blower Kits are used when a wall-mounted variable speed blower control (rheostat) is desired.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 13 Step 1. Follow the instructions below for the model you are installing: Model UVF-36: Using a screwdriver remove the screw from the blower access panel as shown in Figure 18. Slide the panel to the right until the fl ange clears the opening.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 14 Step 8. Ensure that power supply wires are NOT "live" before making these connections).
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 15 FIREBOX FINISHES There are a wide variety of “fi nished looks” for your built-in Vent-Free fi rebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 16 Outside Air Gate & Duct Kit Cat. No. Model No. Description H3991 OAK-UVFRC Outside Air Gate & Duct Kit Outside Air Gate & Duct Kit These kits have an air gate assembly , 4" diam- eter duct and a termination hood.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 17 6 No. Description UVF-36 UVFRC-3628 UVFRC-3628-H UVFRC-4228 UVFRC-4228-H Part No. Qty . Part No. Qty . Part No. Qty. Part No. Qty . Part No. Qty . Gas Fireplace Assembly - - - - - - - - 1. Firescreen H3814 2 H3820 2 H3820 2 H3827 2 H3827 2 2.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 18 NOTES.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 19 NOTES.
Printed in U.S.A. © 2006 by LHP P/N 700,032M REV . B 05/2006 LHP 1110 West T aft Avenue • Orange, CA 92865 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
Een belangrijk punt na aankoop van elk apparaat Superior UVFRC-3628 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Superior UVFRC-3628 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Superior UVFRC-3628 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Superior UVFRC-3628 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Superior UVFRC-3628 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Superior UVFRC-3628 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Superior UVFRC-3628 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Superior UVFRC-3628 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.