Gebruiksaanwijzing /service van het product X-Lander Military van de fabrikant Suunto
Ga naar pagina of 50
www .suunto.com AL TIMAX | VECTOR | X-LANDER INSTRUCTION MANUAL EN | FR | DE | ES | IT | NL | FI | SV.
1. 2. 10. 9. 8. 7. 6. 5. 4. 3. 12. 11..
13. 14. 22. 21. 20. 19. 18. 17. 16. 15. 24. 23..
25. 26. 34. 33. 32. 31. 30. 29. 28. 27. 36. 35..
1 EN Customer SERVICE Contacts Suunto USA Phone 1 (800) 543-9124 Suunto Canada Phone 1 (800) 776-7770 We b Site www .suuntousa.com Suunto Eur ope Phone +33 3 90 20 74 30 Fax +33 3 90 20 74 40 We b Site www .suuntoeur ope.com Suunto Oy Phone +358 9 875 870 Fax +358 9 8758 7301 We b Site www .
2 TABLE OF CONTENTS CHAPTER 1 I NTRODUCTION .......................................................... 6 1.1 GENERAL INFORMA TION ............................................................................................ 6 1.2 MAIN FUNCTIONS (MODES) .
3 2.4.2 How to Start the Countdown T imer ............................................................... 18 2.5 DUAL TIME SUB MODE (AL TIMAX) ........................................................................... 19 2.5.1 Setting the Dual Time Function .
4 CHAPTER 6 FREQUENTL Y ASKED QUESTIONS .......................... 36 6.1 GENERAL .................................................................................................................... .3 6 6.1.1 Is the Wristop Computer waterproof? .....
5 6.4.2 Does the Wristop Computer show future trends in weather conditions? ..... 4 1 6.4.3 What does absolute pressure and relative pressure mean? ................... 41 6.4.4 What is te mperature compe nsation? ..........................
6 CHAPTER 1 INTRODUCTION 1.1 GENERAL INFORMA TION The W ristop Computer is a reliable high precision electronic instrument, intended for recreational use. The outdoor enthusiast who enjoys venturing in sport s like skiing, k ayaking, mount ain climbing, hiking and biking can rely on the Wristop Computer s accuracy .
7 In each of the functions, associated sub modes provide further enhancements to the usefulness of it s owner. All key features and sub modes are discussed in detail following this section. Note: Wristop Computer models Vector and X-Lander provide the same features.
8 1.3.2 The [+] Button Is located on the bottom right of the Wristop Computer . In the setup process, pressing the [+] button changes or scrolls the value upward. In the timing and logbook functions, this button can act as a start/stop (or On/Off) button.
9 The display is divided into several regions or areas. The Outer Circumference encompasses the outer boundary of the LCD display . The peripheral segments are found in the Outer Circumference. A Barometric Trend Indicator provides a quick reference for forecasting weather conditions.
10 1.5 MEASUREMENTS AND UNITS The Wristop Computer supplies two units of measure: metric or imperial. Metric Unit of Measure Imperial Unit of Measure mf t m/min ft/min °C °F mbar inHg 1.5.1 Selecting the Units of Measur ement T o change the unit of measure displayed: 1.
11 9. At the unit of measure desired, PRESS the [Select] button to move to the next unit. Located at the top center in Field 1, m/min or ft/min will begin to flash. 10 PRESS the [+] button to toggle between m/min and ft/min. 1 1 At the unit of measure desired, PRESS the [Mode] button to accept the changes.
12 1.7.1 Batter y R eplacement The Wristop Computer operates on a three-volt lithium cell Type: CR 2430. The maximum life expectancy is approximately 12-18 months. A low battery-warning indicator is activated when 5-15 percent of the battery capacity is still available.
13 After every battery replacement, it is necessary to calibrate the magnetic sensor . Details on performing this process are found in Calibrating the Compass section of this manual.
14 4. PRESS the [+] button to scroll the minutes upward or PRESS the [-] button to scroll the minutes downward. 5. At the minutes desired, PRESS the [Select] button to move to the next setting. Located in the center of Field 2, the hour will begin to flash.
15 Note: If the user does not press any button for 1 minute in the setup mode, the display will automatically exit setup. Setting the time is now complete. 2.2 DAIL Y ALARM SUB MODE The Wristop Computer allows the user to select and enter settings for up to three alarms.
16 8. At the minutes desired, PRESS the [Mode] button to accept the changes and exit the setup program. A small bell will appear at the bottom left side in Field 2 to signify an alarm has been activated. The Alarm setup is complete. T o activate up to three alarms, please repeat steps 1-8 for the selected alarm (1,2, or 3).
17 2. PRESS the [-] button once to stop the stopwatch and to display a split time. 3. PRESS the [-] button a second time to release the split time display and resume the stopwatch. 4. PRESS the [+] button to stop the stopwatch. 5. PRESS the [-] button to reset the stopwatch to zero once the stopwatch has stopped.
18 2.4 COUNTDOWN TIMER SUB MODE In the TIME mode, PRESS the [Select] button three times to enter this sub mode. In the countdown timer sub mode (Fig. 41): Field 1 displays the seconds, Field 2 displays the current time, and Field 3 displays the hours and minutes and to the bottom far right the text timer.
19 Note: When the countdown timer is activated, the countdown timer will continue and remain in the background if the user is in other modes or sub modes. The user can identify the count down timer still activated by the flashing text timer in Field 3.
20 The dual time stays the same, even though the time in the main time mode is adjusted. For example, if you set the dual time to show your home time, your home time will always be displayed in this sub mode even though you travel to a different time zone and adjust the time in the main time mode.
21 THE CURRENT LOCA TION WITH THE ASSOCIA TED AL TITUDE MARKED. THE USER CAN PROCEED AND FOLLOW THE INSTRUCTIONS, SETTING THE AL TIMETER, PROVIDED IN THE SECTION BELOW . DET AILS REGARDING THE EFFECT OF AIR TEMPERA TURE ON AL TITUDE MEASUREMENT ARE SHOWN ON PAGE 41 OF THIS MANUAL.
22 5. At the desired setting, PRESS the [Select] button to move to the next setting. Located in the center of Field 2, the alarm altitude will begin to flash. 6. PRESS the [+] button to scroll the altitude upward or PRESS the [-] button to scroll the altitude downwards.
23 3.2 A L TITUDE DIFFERENCE MEASUREMENT SUB MODE In the Altimeter mode, PRESS the [Select] button once to enter this sub mode. In the Altitude Difference measurement sub mode (Fig.
24 3.3 24-HOUR MEMORY SUB MODE In the Altimeter mode, PRESS the [Select] button twice to enter this sub mode. In the 24-hour memory sub mode (Fig. 15): Field 1 displays the vertical ascent or desc.
25 The second display shows the ascent information for the particular logbook that is being viewed (Fig. 17). Field 1 displays the average ascent rate during the event; Field 2 displays the total vertical ascent ; and Field 3 displays the text ASC along with the text Log Book to the left.
26 3.4.1 How to Star t and Stop a Logbook For the V ector and X-Lander models: In the Altimeter main mode or the difference measurement sub mode, PRESS the [+] button. A beep will be heard and the flashing text Log Book will appear in Field 3 to indicate the start of the recording.
27 After the third display is shown, the Altimax automatically returns to the main mode in which the user was viewing. Note: During this process, pressing the [-] button allows the user to move on to the next of the three displays. 3.5 LOGBOOK HIST OR Y SUB MODE The Logbook history shows a summation of all logs recorded.
28 3.5.1 Clearing the Lo gbook Histor y T o clear the history of the logbook (Fig. 28): 1. In any of the logbook history displays, PRESS the [Select] button and hold in for 2 seconds. Located in Field 1 is the text CLR; in Field 2 the text HIS; and in Field 3, nO will begin to flash.
29 T o view and use the Barometer mode: Check the Mode Indicator Bar. If the mode arrow is not on BARO, PRESS the [Mode] button until the arrow is directly below BARO on the bar . In the Barometer mode (Fig. 5): Field 1 displays the current temperature.
30 4.1.1 How to Start the Pr essur e Dif f er ence Measur ement 1. PRESS the [Select] button and hold in for 2 seconds. Located in Field 1 is the text SET; located in Field 2, zero will begin to flash (Fig. 29). 2. PRESS the [Mode] button to accept the flashing zero and start the difference measurement.
31 4.3 SEA LEVEL PRESSURE SUB MODE Sea level pressure is pressure relative to sea level where as the pressure read in the main barometric display is absolute pressure in the current location. In the Barometer mode, PRESS the [Select] button three times to enter this sub mode.
32 4.4 BA ROMETRIC TREND INDICA TOR Located on the top left corner of the LCD display resides the Barometric T rend Indicator. This feature is always displayed in all main modes providing the user a continual quick reference to analyze upcoming weather conditions.
33 bearing degrees; a North-South arrow; a bearing track mode showing desired direction and actual bearing; a bubble level for accuracy reading +3 degrees (except in the X-Lander); a rotating bezel; a resolution of 1° for the bearing, +5° for North-South direction; and a declination correction feature.
34 5.1 BEARING TRACKING SUB MODE The user can select to change from the cardinal point mode to the bearing track function and utilize the bearing lock function in this mode for tracking purposes (Fig. 7). In the compass main mode: 1. PRESS the [Select] button and hold in for 2 seconds.
35 5.2.1 Setting the Local Declination 1. PRESS the [Select] button and hold in for 2 seconds. Located in Field 1, OFF will begin to flash. 2. PRESS either the [+] or the [-] button to change the declination direction in Field 1. 3. At the direction desired, PRESS the [Select] button to move to the next setting.
36 direction of turning does not matter. The lit segments will be turned off as the turning proceeds. When the first full circle is completed, the instrument will inform the user within one minute of whether the calibration was successful displaying the text dOnE in Field 2 (Fig.
37 6.1.3 W ha t do the se gments on the cir cumference mean? In the Altimeter mode, one full circle equals 1,000 meters or 1,000 feet, therefore the segment s on the circumference graphically show the user the altitude over a full thousand.
38 6.2 TIME 6.2.1 W hy do the se gments on the cir cumf er ence increase and decrease w hen I am in t he Time mode? The main function of the segments is related to the Comp ass mode, where a division into 36 segments is necessary due to the 360-degree scale of a compass.
39 T o avoid excessive battery drain, the recording is not continuous. The recording functions have certain timeouts (i.e. the recording will be turned off automatically after a certain time). The timeouts are shorter for the faster interval and longer for the slower interval.
40 Third, if think ing about the difference measurement function and how this is affected by the example situation, the Wristop Computer will show you the absolute difference between 5,000 ft and 8,000 ft (beginning and end).
41 6.4.2 Does the Wristop Computer show futur e trends in weather conditions? No, the Wristop Computer continually accumulates data on barometric pressure existent within a 3 to 6 hour window and displays general barometric trends in weather based on the accumulated data.
42 6.5.2 Wher e do I find the cor rect declination for my area so I can set my Wristop Computer? Local declination, either E or W , is usually marked on maps with either one-degree or half-degree accuracy .
43 1800 5906 3.3 37.9 2000 6562 2.0 35.6 2400 7874 -0.6 30.9 2800 9187 -3.2 26.2 3000 9843 -4.5 23.9 3400 1 1 155 -7.1 19.2 3800 12468 -9.7 14.5 4000 13124 -1 1.0 12.2 4500 14765 -14.3 6.4 5000 16405 -17.5 0.5 5500 18046 -20.8 -5.4 6000 19686 -24.0 -1 1.
44 Lower point Higher point Set reference altitude (real altitude) 1000 m Displayed altitude 3000 m Real outside temperature +17.5 ºC +6.5 ºC Normal (table) temperature +8.5 ºC -4.5 ºC T emperature offset (= real - normal) +9 ºC +1 1 ºC Sum of temperature offset s +9 ºC + +1 1 ºC = 20 ºC T able 2.
45 8. ABBREVIA TIONS dEF - default factory setting of pressure sensor , corresponds to standard (1013 mbar or 29,90 inHg) airpressure at sea level SNR - sensor (used in sensor calibration) RE - refere.
46 11. LIMITS OF LIABILITY AND ISO 9001 COMPLIANCE If this product should fail due to defects in materials or workmanship, Suunto Oy will, at its sole option, repair or replace it with new or rebuilt p arts, free of charge, for two (2) years from the date of its purchase.
Een belangrijk punt na aankoop van elk apparaat Suunto X-Lander Military (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Suunto X-Lander Military heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Suunto X-Lander Military vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Suunto X-Lander Military leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Suunto X-Lander Military krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Suunto X-Lander Military bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Suunto X-Lander Military kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Suunto X-Lander Military . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.