BACK (OUTDOOR AIRFLOW) END OF UNIT
Standard Engineered Features Field Installed Accessories
Optional Field Installed Electric Heat Strips: With automatic limit and thermal cutoff.
Air Conditioner Compressor: Reciprocating compressors with crankcase heaters are standard on 2, 2½ and 3-ton models. Scroll compressors are used on all other models and no crankcase heaters are required.
Compressor Control Module: Built-in off-delay timer adjustable from 30 seconds to 5 minutes. 2-minute on-delay if power interrupt. 120- second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay.
R-410A Refrigerant: Designed with R-410A (HFC) non- ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements.
Optional Field Installed Low Ambient Control: Cycles outdoor fan motor below 55°F outdoor temperature to maintain acceptable condensing pressure.
Phase Rotation Monitor: Standard on all 3-phase models. Protects against reverse rotation if power supply is not properly connected.
ECM Indoor Blower Motor: Features an electronically commutated motor providing super-high efficiency, low sound levels and soft-start capabilities. The motor is self- adjusting to provide the proper airflow rate for a broad range of static pressure in ducted installations without user adjustment or wiring changes.
High & Low Pressure Switches are Auto-Reset Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor.
Pre-Painted 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03.
Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.
Outdoor coil is constructed with special corrosion resistant hydrophilic fin stock with 2-layer coating. (1st layer - blue acrylic primer; 2nd layer - clear topcoat.)
Pre-Painted 16 Gauge Zinc Coated Unit Base: The unit base is treated with the same paint coatings as the cabinet above, insuring years of service.
Thermal Expansion Valves: Models with reciprocating compressors have bleed TXV, models with scroll compressor have non-bleed TXV.
Top Discharge Outdoor Fan: Efficiently moves air quietly for effective heat exchange.
Discharge Muffler: Standard on 2½ and 3-ton models.
Electrical Components & Controls: Readily accessible for easier service.
Liquid Line Filter Drier: Protects system against moisture.

Tested and Certified in accordance with ARI Standard 210/240-2003.
1 ECM = Electronically Commutated Motor 2 Maximum time delay fuse or HACR type circuit breaker for protection of field wiring devices. 3 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes. 4 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to National Electric Code (latest revision), Article 310 for power conductor sizing.
1 Motor will deliver consistent CFM through voltage supply range with no deterioration (197-253V for all 230/208V models). 2 Continuous CFM is the total air being circulated during continuous (manual fan) mode. 3 Will occur automatically with a call for “Y” for cooling mode operation. 4 Will occur automatically with a call for “W1” for heating mode operation.

Optional field-installed electric heater packages are available for 5 through 15Kw capacities. The heater packages are UL listed to be field-installed into the basic unit. They feature prewired control circuit wiring with plug-in connector. Simply slide the heater into the unit, plug in the pretested control circuit and connect the separate high voltage circuit wiring.

Optional Field Installed Heater Packages Are Only To Be Used With The Models As Indicated Below
r e t a e H
e g a k c a P
& s tl o V
A - 2 4 2 3 1 A P A - 2 0 3 3 1 A P A - 2 6 3 3 1 A P B - 2 6 3 3 1 A P A - 2 2 4 3 1 A P B - 2 2 4 3 1 A P C - 2 2 4 3 1 A P A - 2 8 4 3 1 A P B - 2 8 4 3 1 A P C - 2 8 4 3 1 A P A - 2 0 6 3 1 A P B - 2 0 6 3 1 A P C - 2 0 6 3 1 A P
l e d o M
e s a h P
5 0 A - 3 2 3 P H E 1 - 8 0 2 / 0 4 2 X X X
0 1 A - 3 2 3 P H E 1 - 8 0 2 / 0 4 2 X X X
5 1 A - 3 2 3 P H E 1 - 8 0 2 / 0 4 2 X X
9 0 B - 3 2 3 P H E 3 - 8 0 2 / 0 4 2 X
5 1 B - 3 2 3 P H E 3 - 8 0 2 / 0 4 2 X
5 0 A - 3 1 5 P H E 1 - 8 0 2 / 0 4 2 X X X
0 1 A - 3 1 5 P H E 1 - 8 0 2 / 0 4 2 X X X
5 1 A - 3 1 5 P H E 1 - 8 0 2 / 0 4 2 X X X
9 0 B - 3 1 5 P H E 3 - 8 0 2 / 0 4 2 X X X
5 1 B - 3 1 5 P H E 3 - 8 0 2 / 0 4 2 X X X
9 0 C - 3 1 5 P H E 3 - 0 6 4 X X X
5 1 C - 3 1 5 P H E 3 - 0 6 4 X X X
1 Maximum size of the time delay fuse or HACR circuit breaker for protection of field wiring devices.
2 Based on wire suitable for 75°C. Other wiring materials must be rated for marked “Minimum Circuit Ampacity” or greater. Based on 75°C copper wire. All wiring must conform to the National Electric Code and all local codes.
3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310 for power conductor sizing.

1 Below 55°F, unit requires a field installed low ambient control model CMA-28. 2 Return air temperature °F.



Side
Slab Mounting at Ground Level
Air Outlet · Nearest Structure




. o N l e d o M o T e l b a c il p p A t h g i e W g n i p p i h S
A - 3 1 3 P H R sle d o m n o t 3 d n a 2 / 1 - 2 , 2 0 1 1
A - 3 1 5 P H R sle d o m n o t 5 d n a 4 , 2 / 1 - 3 0 2 1
g n ip p ih S - stin u tn ela viu q E †

X A WIDTH AIR CONDITIONING UNIT
FILTER
FRESH AIR OPENING
MIS-2254
Optional Equipment — Pre-Fabricated Roof Curb
. o N l e d o M o T e l b a c il p p A † . U . E t h g i e W g n i p p i h S
3 0 0 - 2 4 0 9 sle d o m n o t 3 d n a 2 / 1 - 2 , 2 0 8 . 4 4 1
4 0 0 - 2 4 0 9 sle d o m n o t 5 d n a 4 , 2 / 1 - 3 0 8 . 0 6 1
g n ip p ih S - stin u tn ela viu q E †
Heavy gauge galvanized with wood nailing strip, welded/leakproof one piece construction - ready to install.

h ti W d e s U
d o o H f o o R
d n a p m u P t a e H
l e d o M
l e d o M A B C 1 D E F J 1 H 1
s ti n U g n i n o iti d n o C ri A
3 0 0 - 2 4 0 9 ) b r u C 6 3 P ( A - 3 1 3 P H R 8 / 3 - 0 8 4 / 1 - 0 4 4 / 1 - 7 3 8 / 3 - 8 3 8 / 3 - 5 3 2 4 4 / 3 - 4 1 8 / 1 - 9 1 sle d o M n o T 3 & , 2 / 1 - 2 , 2 ll A
4 0 0 - 2 4 0 9 ) b r u C 0 6 P ( A - 3 1 5 P H R 8 / 3 - 2 8 8 / 1 - 4 4 8 / 1 - 1 4 8 / 3 - 8 3 8 / 3 - 5 3 4 4 4 / 3 - 4 1 8 / 1 - 9 1 sle d o M n o T 5 & 4 , 2 / 1 - 3 ll A
1 Duct Sizing Information: Return air dimension “C” is length / Supply air dimension “C” is length. Return air dimension “H” is width / Supply air dimension “J” is width.
12 1/2" · 1 1/2"

. o N l e d o M t h g i e W g n i p p i h S
) V 8 0 2 / 0 3 2 ( X - D 3 A - R V R E . s bl 5 2 1

Legend: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery
ROOF CURB
ROOF
MIS-2253
SUPPLY DUCT RETURN DUCT
R V R E 4 / 3 - 2 3 * 4 / 3 - 8 1 4 / 3 - 8 1 .s bl 5 2 1
* Does not include 1" mounting brackets on each side of ERVR.
Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com
Due to our continuous product improvement policy, all specifications subject to change without notice.
Form No.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
S3383 November, 2012