Product Reference Guide
72-68456-01 · Revision A · July 2004

© 2004 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.
The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to maintain Symbol’s copyright notice on the licensed programs delivered hereunder and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in Symbol products.
Symbol, Spectrum One and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.com


Introduction xiii Chapter Descriptions xiii Notational Conventions xiii Related Publications xiv Service Information xiv
Symbol Support Center xiv

DS 3408 Product Reference Guide xii

Introduction The DS 3408 Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the DS 3408 Standard Range and DS 3408 High Density digital scanners.

DS 3408 Product Reference Guide xiv
Related Publications The LS/DS 3408 Quick Start Guide, p/n 72-67131-xx, provides general information for getting started with the digital scanner, and includes basic set up and operation instructions.
For the latest versions of the Quick Start Guide and Product Reference Guide go to: http://www.symbol.com/manuals
Service Information If you have a problem with your equipment, contact the Symbol Support Center for your region. See page xvi for contact information. Before calling, have the model number, serial number, and several of your bar code symbols at hand.
Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, the Support Center will request samples of your bar codes for analysis at our plant.
If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions.
Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.
Symbol Support Center For service information, warranty information, or technical assistance contact or call the Symbol Support Center in:
United States Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 1-800-653-5350
Canada Symbol Technologies Canada, Inc. 2540 Matheson Boulevard East Mississauga, Ontario, Canada L4W 4Z2 905-629-7226
United Kingdom Symbol Technologies Symbol Place Winnersh Triangle, Berkshire RG41 5TP United Kingdom 0800 328 2424 (Inside UK) +44 118 945 7529 (Outside UK)
Asia/Pacific Symbol Technologies Asia, Inc (Singapore Branch) 230 Victoria Street #05-07/09 Bugis Junction Office Tower Singapore 188024 Tel : +65-6796-9600 Fax : +65-6337-6488

Australia Symbol Technologies Pty. Ltd. 432 St. Kilda Road Melbourne, Victoria 3004 1-800-672-906 (Inside Australia) +61-3-9866-6044 (Outside Australia)
Austria/Österreich Symbol Technologies Austria GmbH Prinz-Eugen Strasse 70 / 2.Haus 1040 Vienna, Austria 01-5055794-0 (Inside Austria) +43-1-5055794-0 (Outside Austria)
Denmark/Danmark Symbol Technologies AS Dr. Neergaardsvej 3 2970 Hørsholm 7020-1718 (Inside Denmark) +45-7020-1718 (Outside Denmark)
Europe/Mid-East Distributor Operations Contact your local distributor or call +44 118 945 7360
France Symbol Technologies France Centre d'Affaire d'Antony 3 Rue de la Renaissance 92184 Antony Cedex, France 01-40-96-52-21 (Inside France) +33-1-40-96-52-50 (Outside France)
Finland/Suomi Oy Symbol Technologies Kaupintie 8 A 6 FIN-00440 Helsinki, Finland 9 5407 580 (Inside Finland) +358 9 5407 580 (Outside Finland)
Italy/Italia Symbol Technologies Italia S.R.L. Via Cristoforo Columbo, 49 20090 Trezzano S/N Navigilo Milano, Italy 2-484441 (Inside Italy) +39-02-484441 (Outside Italy)
Germany/Deutschland Symbol Technologies GmbH Waldstrasse 66 D-63128 Dietzenbach, Germany 6074-49020 (Inside Germany) +49-6074-49020 (Outside Germany)
Mexico/México Symbol Technologies Mexico Ltd. Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas de Chapultepec CP 11000 Mexico City, DF, Mexico 5-520-1835 (Inside Mexico) +52-5-520-1835 (Outside Mexico)
Latin America Sales Support 2730 University Dr. Coral Springs, FL 33065 USA 1-800-347-0178 (Inside United States) +1-954-255-2610 (Outside United States) 954-340-9454 (Fax)
Norway/Norge Symbol’s registered and mailing address: Symbol Technologies Norway Hoybratenveien 35 C N-1055 OSLO, Norway
Netherlands/Nederland Symbol Technologies Kerkplein 2, 7051 CX Postbus 24 7050 AA Varsseveld, Netherlands 315-271700 (Inside Netherlands) +31-315-271700 (Outside Netherlands)
Symbol’s repair depot and shipping address: Symbol Technologies Norway Enebakkveien 123 N-0680 OSLO, Norway
+47 2232 4375

DS 3408 Product Reference Guide xvi
South Africa Symbol Technologies Africa Inc. Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11-809 5311 (Inside South Africa) +27-11-809 5311 (Outside South Africa)
Spain/España Symbol Technologies S.L. Avenida de Bruselas, 22 Edificio Sauce Alcobendas, Madrid 28108 Spain 91 324 40 00 (Inside Spain) +34 91 324 40 00 (Outside Spain) Fax: +34.91.324.4010
Switchboard: 08 445 29 00 (domestic) Call Center: +46 8 445 29 29 (international) Support E-Mail: Sweden.Support@se.symbol.com
If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.

Introduction 1-3 Unpacking 1-4 Setting Up the Digital Scanner 1-4
Installing the Interface Cable 1-4 Removing the Interface Cable 1-5 Connecting a Synapse Cable Interface 1-6 Connecting Power (if required) 1-6 Configuring the Digital Scanner 1-6



Introduction The digital scanner combines superior 1D and 2D omnidirectional bar code scanning and advanced ergonomics to provide the best value in a digital scanner. Whether in hand-held mode or hands-free mode in a stand, the digital scanner ensures comfort and ease of use for extended periods of time.
The digital scanner supports:
Getting Started 1-3

Unpacking Remove the digital scanner from its packing and inspect it for damage. If the digital scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page xiv. KEEP THE PACKING. It is the approved shipping container; use this to return the equipment for servicing.
Installing the Interface Cable

Different cables are required for different hosts. The connectors illustrated in each host chapter are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner remain the same.
Getting Started 1-5

Refer to the Synapse Interface Guide provided with the Synapse cable for detailed setup instructions.
Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The Synapse cable has built-in intelligence to detect that host.
Connecting Power (if required) If the host does not provide power to the digital scanner, connect an external power supply to the digital scanner:
Configuring the Digital Scanner To configure the digital scanner, use the bar codes included in this manual, or the 123Scan configuration program.
See Chapter 4, User Preferences for information about programming the digital scanner using bar code menus. Also see each host- specific chapter to set up connection to a specific host type.
See Chapter 12, 123 Scan to configure the digital scanner using this configuration program. A help file is available in the program.

Introduction 2-3 Beeper Definitions 2-4 LED Definitions 2-5 Scanning in Hand-Held Mode 2-6
Scanning with the Digital Scanner 2-6 Aiming 2-7 Scanning in Hands-Free Mode 2-8 Decode Zones 2-9
Near Focus 2-9 Far Focus 2-10 Toggled Focus 2-11



Introduction This chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general instructions and tips about scanning, and decode zone diagrams.

Scanning 2-3

Beeper Definitions The digital scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the digital scanner.
Short low/short medium/short high beep sequence
Power up.
1 short high beep A bar code symbol was decoded (if decode beeper is enabled).
4 long low beeps A transmission error was detected in a scanned symbol. The data is ignored. This occurs if the digital scanner is not properly configured. Check option setting.
5 low beeps Conversion or format error.
Lo/hi/lo beeps ADF transmit error. See Chapter 15, Advanced Data Formatting.
Short high/short high/short high/long low beep sequence
RS-232 receive error.
Short high beep Correct entry scanned or correct menu sequence performed.
Long low/long high beep sequence Input error; incorrect bar code, programming sequence, or Cancel scanned; digital scanner remains in ADF program mode.
Short high/short low beep sequence Keyboard parameter selected. Enter value using numeric bar codes.
Short high/short low/short high/short low beep sequence
Successful program exit with change in parameter setting.
Short low/short high/short low/short high beep sequence
Out of host parameter storage space. Scan Set Default Parameter on page 4-5.
Hi/lo beeps New Code 39 data was entered into the buffer.
3 long high beeps Code 39 buffer is full.
Lo/hi/lo beeps The Code 39 buffer was erased or there was an attempt to clear or transmit an empty buffer.
Lo/hi beeps A successful transmission of buffered data.
2 long low beeps File ID error. A bar code not in the current MPDF sequence was scanned.
3 long low beeps Out of memory. There is not enough buffer space to store the current MPDF symbol.
4 long low beeps Bad symbology. Scanned a 1D or 2D bar code in a MPDF sequence, a duplicate MPDF label, a label in an incorrect order, or trying to transmit an empty or illegal MPDF field.
5 long low beeps Flushing MPDF buffer.
Fast warble beep Aborting MPDF sequence.
Lo/Hi beeps Flushing an already empty MPDF buffer.
ADF Programming: Normal Data Entry. Duration of tones are short.
Hi/Lo beeps Enter another digit. Add leading zeros to the front if necessary.
Lo/Lo beeps Enter another alphabetic character or scan the End of Message bar code.

Hi/Hi beeps Enter another criterion or action, or scan the Save Rule bar code.
Hi/Lo/Hi/Lo beeps Rule saved. Rule entry mode exited.
Hi/Lo/Lo beeps All criteria or actions cleared for current rule, continue entering rule.
Low beep Delete last saved rule. The current rule is left intact.
Lo/Hi/Hi beeps All rules are deleted.
ADF Programming: Error Indications. Duration of tones are very long.
Lo/Hi/Lo/Hi beeps Out of rule memory. Erase some existing rules, then try to save rule again. (It is not necessary to re-enter the current rule.)
Lo/Hi/Lo beeps Cancel rule entry. Rule entry mode exited because of an error or the user asked to exit rule entry.
Lo/Hi beeps Entry error, wrong bar code scanned. Re-enter criterion or action. All previously entered criteria and actions are retained. Criteria or action list is too long for a rule.
4 short high beeps Digital scanner has not completed initialization. Wait several seconds and scan again.
Short low/short medium/short high beep sequence after scanning a USB device type
Communication with the bus must be established before the digital scanner can operate at the highest power level.
Short low/short medium/short high beep sequence occurs more than once
The USB bus can put the digital scanner in a state where power to the digital scanner is cycled on and off more than once. This is normal and usually happens when the PC cold boots.
1 short high beep A character is received and Beep on is enabled.
LED Definitions In addition to beep sequences, the digital scanner uses a two-color LED to indicate status. Table 2-2 defines LED colors that display during scanning.
Off No power is applied to the digital scanner, or the digital scanner is on and ready to scan.
Green A bar code was successfully decoded.
Red A data transmission error or digital scanner malfunction occurred.

Scanning in Hand-Held Mode Install and program the digital scanner (see Setting Up the Digital Scanner on page 1-4). For assistance, contact the local supplier or the local Symbol Support Center.
If necessary, the digital scanner turns on its red LEDs to illuminate the target bar code.
1D bar code 2D bar code
Linear bar code PDF417 symbol
Symbol · Aiming Pattern

Aiming Hold the digital scanner between two and nine inches (depending on symbol density; see Decode Zones on page 2-9) from the symbol, centering the aiming pattern cross hairs on the symbol.
The aiming pattern is smaller when the digital scanner is closer to the symbol and larger when it is farther from the symbol. Scan symbols with smaller bars or elements (mil size) closer to the digital scanner, and those with larger bars or elements (mil size) farther from the digital scanner.
The digital scanner can also read a bar code presented within the aiming pattern but not centered. The top examples in Figure 2-5 show acceptable aiming options, while the bottom examples can not be decoded.
0 1 2 3 4 5
0 1 2 3 4 5
0 1 2 3 4 5
0 1 2 3 4 5
Scanning 2-7

Scanning in Hands-Free Mode The optional Intellistand adds greater flexibility to scanning operation. When the digital scanner is seated in the stand’s “cup,” the digital scanner’s built-in sensor places the digital scanner in hands-free mode. When the digital scanner is removed from the stand it operates in its normal hand-held mode.
Adjust angle of scanner “cup”
Scanner “Cup” Adjust height of IntelliStand
To operate the digital scanner in the IntelliStand:
1. Ensure the digital scanner is properly connected to the host (see the appropriate host chapter for information on host connections). 2. Insert the digital scanner in the Intellistand by placing the front of the digital scanner into the stand’s “cup” (see Figure 2-6). 3. Use the Intellistand’s adjustment knobs to adjust the height and angle of the digital scanner. 4. Center the symbol in the aiming pattern. The entire symbol must be within the brackets. 5. Upon successful decode, the digital scanner beeps and the LED turns green. For more information on beeper and LED definitions, see Table 2-1 and Table 2-2.

Near Focus
in. Note: Typical performance at 73˚F (23˚C) on high quality symbols in normal room light. Vcc = 3.3V
F
1.75 4.4
2.0 5.5
6.67 mil PDF417 2.3 4.5
3.5 8.9
7.5 mil 1.3 6.3
10 mil PDF417 1.8 5.8
0.8 7.3
13 mil (100% UPC)
In. cm
2 4 6 8 10 0 5.1 10.2 15.2 20.3 25.4
* Minimum distance determined by symbol length and scan angle.

in.
4 Top of scanner
5.0 6.0
7.5 mil 2.8 8.5
4.3 8.8
13 mil (100% UPC)
1.5 14.5
In. cm
5 10 15 20 0 12.7 25.4 38.1 50.8
* Minimum distance determined by symbol length and scan angle.

in.
2.0 6.0
6.67 mil PDF417 2.3 4.5
7.5 mil 1.3 8.5
1.8 8.8
13 mil (100% UPC)
0.8 14.5
5 10 15 20 0 12.7 25.4 38.1 50.8
In. cm
* Minimum distance determined by symbol length and scan angle.



Specifications
Introduction 3-3 Maintenance 3-3 Troubleshooting 3-3 Technical Specifications 3-5 Digital Scanner Signal Descriptions 3-6



Maintenance and Technical Specifications 3-3
Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.
Problem Possible Causes Possible Solutions
The aiming pattern does not appear when pressing the trigger.
No power to the digital scanner. If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used. Connect the correct host interface cable.
Interface/power cables are loose. Re-connect cables.
Digital scanner is disabled. For Synapse or IBM 468x mode, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted. Assert CTS line.
Aiming pattern is disabled. Enable the aiming pattern. See Decode Aiming Pattern on page 5-6.
Scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.
The USB bus may put the digital scanner in a state where power to the digital scanner is cycled on and off more than once.
Normal during host reset.
Digital scanner emits aiming pattern, but does not decode the bar code.
Digital scanner is not programmed for the correct bar code type.
Program the digital scanner to read that type of bar code. See Chapter 13, Symbologies.
Bar code symbol is unreadable. Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern. Move the symbol completely within the aiming
pattern.
Digital scanner emits 4 short high beeps during decode attempt.
Digital scanner has not completed USB initialization. Wait several seconds and scan again.

Problem Possible Causes Possible Solutions
Digital scanner decodes bar code, but does not transmit the data to the host.
Digital scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose. Re-connect the cable.
If 4 long low beeps are heard, a transmission error occurred.
Set the digital scanner's communication parameters to match the host's setting.
If 5 low beeps are heard, a conversion or format error occurred.
Configure the digital scanner's conversion parameters properly.
If lo/hi/lo beeps are heard, an invalid ADF rule is detected.
Program the correct ADF rules.
If hi/lo beeps are heard, the digital scanner is buffering Code 39 data.
Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.
Host displays scanned data incorrectly. Digital scanner is not programmed to work with the host.
Scan the appropriate host type programming bar code.
For RS-232, set the digital scanner's communication parameters to match the host's settings.
For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key.
Program the proper editing options (e.g., UPC-E to UPC-A Conversion).
Digital scanner emits hi/hi/hi/Lo beeps when not in use.
RS-232 receive error. Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.
Digital scanner emits lo/hi beeps during programming.
Input error or Cancel bar code was scanned. Scan the correct numeric bar codes within range for the parameter programmed.
Digital scanner emits lo/hi/lo/hi beeps during programming.
Out of ADF parameter storage space. Erase all rules and re-program with shorter rules.
Out of Synapse parameter storage space. Scan Set Synapse Defaults bar code for cables no longer in use and re-program the digital scanner for the current host interface.
Digital scanner emits lo/hi/lo beeps. Clearing Code 39 buffer. Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.
Digital scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital scanner.
Normal when changing USB host type.
Digital scanner emits one high beep when not in use. In RS-232 mode, a character was received
Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.
and Beep on option is enabled.
If after performing these checks the digital scanner still experiences problems, contact the distributor or call the local Symbol Support Center. See page xiv for the telephone numbers.

Maintenance and Technical Specifications 3-5
Power Requirements 5 VDC + / - 10% @ approximately 220 mA RMS (nominal), 500 mA (max)
Depending on host:
UPC/EAN, UPC/EAN with supplementals, UCC/EAN, JAN 8 & 13, 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, IATA 2 of 5, Code 128, Code 93, MSI, Code 11, Code 32, Coupon Code, Bookland EAN, RSS, US Postnet, US Planet,UK Postal, Japan Postal, Australia Postal, Dutch Postal, Composite Codes, PDF417, MicroPDF, Maxicode, Data Matrix (ECC 200), QR Code.
Yaw Tolerance ± 50° from normal
Pitch Tolerance ± 60° from normal
Roll Tolerance ± 180° from normal
Print Contrast Minimum 25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity 10,000 Ft Candles (107,600 Lux)
Durability 6.5 ft (2 m) drop to concrete
Operating Temperature -4° to 122° F (-20° to 50° C)
Storage Temperature -40° to 158° F (-40° to 70° C)
Humidity 5% to 95% (non-condensing)
Weight (without cable) 11.73 oz. (335 g)
Dimensions:
7.34 in. (18.65 cm) 4.82 in. (12.25 cm) 2.93 in. (7.43 cm)
Laser 650nm laser diode
Laser Classifications IEC 825-1 Class 2
ESD 15 kV area discharge 8 kV contact discharge
Minimum Element Width 5 mil (0.127 mm)
Interfaces Supported RS-232, Keyboard Wedge, Wand Emulation, Scanner Emulation, IBM 468X/469X, USB, Synapse
Electrical Safety UL1950, CSA C22.2 No.950. EN60950/IC950
Input Transient Protection IEC 1000-4-(2,3,4,5,6,11)
EMI FCC Part 15 Class B, ICES-003 Class B European Union EMC Directive, Japan VCCI/MITI/Dentori


The signal descriptions in Table 3-3 apply to the connector on the digital scanner and are for reference only.
1 Reserved SynClock Reserved Reserved Reserved Jump to Pin 6 DBP
5 Reserved Reserved RxD TermData CTS D + Decode
6 IBM_B(-) SynData RTS KeyData RTS Jump to Pin 1 Trigger
7 Reserved Reserved CTS TermClock Reserved D - Enable

Introduction 4-3 Scanning Sequence Examples 4-3 Errors While Scanning 4-3 User Preferences Parameter Defaults 4-4 User Preferences 4-5
Set Default Parameter 4-5 Parameter Scanning 4-5 Beeper Tone 4-6 Beeper Volume 4-7 Power Mode 4-7 Time Delay to Low Power Mode 4-8 Trigger Mode 4-9 Decode Session Timeout 4-10 Timeout Between Decodes, Same Symbol 4-10 Beep After Good Decode 4-11 Scanstand Session Timeout 4-11



Introduction If desired, program the digital scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides the programming bar codes necessary for selecting these features.
The digital scanner ships with the settings shown in the Table 4-1 on page 4-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary.
To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host.
To return all features to default values, scan the Set All Defaults bar code on 4-5. Throughout the programming bar code menus, default values are indicated with asterisks (*).

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-6. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences 4-3

User Preferences Parameter Defaults Table 4-1 lists defaults for user preferences parameters. To change any option, scan the appropriate bar code(s) provided in the User Preferences section beginning on page 4-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 4-1. User Preferences Default Table
Set Default Parameter All Defaults 4-5
Parameter Scanning ECh Enable 4-5
Beeper Tone 91h Medium 4-6
Beeper Volume 8Ch High 4-7
Power Mode 80h Continuous On 4-7
Time Delay to Low Power Mode 92h 5 Minutes 4-8
Trigger Mode 8Ah Level 4-9
Decode Session Timeout 88h 9.9 Sec 4-10
Timeout Between Decodes, Same Symbol 89h 0.6 Sec 4-10
Beep After Good Decode 38h Enable 4-11
Scanstand Session Timeout F0h, 90h 2 Seconds 4-11

Set Default Parameter Scan this bar code to return all parameters to the default values listed in Table A-1 on page A-3.
Parameter # ECh To disable decoding of parameter bar codes, scan the Disable Parameter Scanning bar code below. Note that the Set Defaults parameter bar code can still be decoded. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning or Set All Defaults.

*Enable Parameter Scanning (01h)


Parameter # 91h To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.




Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.


Power Mode
Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In reduced power mode, the digital scanner enters into a low power consumption mode to preserve battery life after each decode attempt. In continuous power mode, power remains on after each decode attempt.




This parameter only applies when Power Mode is set to Reduced Power.
This parameter sets the time the digital scanner remains active after decoding. The digital scanner wakes upon trigger pull or when the host attempts to communicate with the digital scanner.

Trigger Mode
Parameter # 8Ah Select one of the following trigger modes for the digital scanner:


Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on page D-4.

Parameter # 89h This option is used in hands-free (Intellistand) mode to prevent the beeper from continuously beeping when a symbol is left in the digital scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.

Timeout Between Decodes, Same Symbol
Decode Session Timeout

Parameter # 38h Scan a bar code below to select whether or not the digital scanner beeps after a good decode. If selecting Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and to indicate error conditions.


Do Not Beep After Good Decode
Parameter # F0h, 90h To set the amount of time the digital scanner attempts to decode a bar code in hands-free mode (blink mode), scan the bar code below. Next, scan three numeric bar codes from Appendix D, Numeric Bar Codes to select a value between 1 and 255 that represents tenths of a second. Single digit numbers must have a leading zero. For example, to set 0.5 seconds, scan the bar code below, then scan the 0, 0, 5 bar codes. To correct an error or change the selection, scan Cancel on page D-4. The default value is 2 seconds.



Introduction 5-3 Scanning Sequence Examples 5-3 Errors While Scanning 5-3 Decoding Preferences Parameter Defaults 5-3 Decoding Preferences 5-5
Focus Mode 5-5 Decoding Illumination 5-6 Decode Aiming Pattern 5-6



Introduction If desired, program the digital scanner to perform various functions, or activate different features. This chapter describes digital scanner preference features and provides the programming bar codes for selecting these features.
The digital scanner ships with the settings shown in the Decoding Preferences Default Table on page 5-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary.
To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host.
To return all features to default values, scan the Set Default Parameter bar code on page 4-5. Throughout the programming bar code menus, default values are indicated with asterisks (*).
Feature/Option * Indicates Default *Enable Decode Aiming Pattern (02h) Hex Value
Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to disable the decode aiming pattern, scan the Disable Decode Aiming Pattern bar code listed under Decode Aiming Pattern on page 5-6. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Decoding Preferences Parameter Defaults Table 5-1 lists defaults for digital scanner preferences parameters. To change any option, scan the appropriate bar code(s) provided in Decoding Preferences on page 5-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Decoding Preferences 5-3

Number Default Page Number
Focus Mode F0h A6h Far Focus 5-5
Decoding Illumination F0h 2Ah Enable 5-6
Decode Aiming Pattern F0h 32h Enable 5-6
Parameter Parameter · Decoding Options

Decoding Preferences The parameters in this chapter control bar code decoding characteristics.
Parameter # F0h, A6h Select the Focus Mode to control the working range of the digital scanner. If Far Focus is selected, the digital scanner is optimized to read at its far position. With Near Focus, the digital scanner is optimized to read at its near position. Smart Focus toggles the focus position after every frame.

Parameter # F0h, 2Ah Selecting Enable Illumination causes the digital scanner to flash illumination to aid decoding. Select Disable Illumination to prevent the digital scanner from using decoding illumination.
Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases.

*Enable Decoding Illumination (01h)

Parameter # F0h, 32h This parameter only applies when in Decode Mode. Select Enable Decode Aiming Pattern to project the aiming pattern during bar code capture, or Disable Decode Aiming Pattern to turn the aiming pattern off.
*Enable Decode Aiming Pattern (02h)
Disable Decode Aiming Pattern
Disable Decoding Illumination · (00h) · (00h)

Introduction 6-3 Connecting a Keyboard Wedge Interface 6-3 Keyboard Wedge Parameter Defaults 6-4 Keyboard Wedge Host Parameters 6-5
Keyboard Wedge Host Types 6-5 Keyboard Wedge Country Types (Country Codes) 6-6 Ignore Unknown Characters 6-8 Keystroke Delay 6-8 Intra-Keystroke Delay 6-9 Alternate Numeric Keypad Emulation 6-9 Caps Lock On 6-10 Caps Lock Override 6-10 Convert Wedge Data 6-11 Function Key Mapping 6-11 FN1 Substitution 6-12 Send Make and Break 6-12 Keyboard Maps 6-13 ASCII Character Set for Keyboard Wedge 6-15



Keyboard Wedge Interface 6-3
Introduction This chapter describes how to set up a Keyboard Wedge interface with the digital scanner. With this interface, the digital scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting a Keyboard Wedge Interface
Female DIN Connector Keyboard Connector
To connect the Keyboard Wedge interface Y-cable:
Interface cables vary depending on configuration. The connectors illustrated in Figure 6-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
Male DIN Connector

3. Connect the round male DIN host connector of the Y-cable to the keyboard port on the host device. 4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard connector. 5. If needed, attach the optional power supply to the connector in the middle of the Y-cable. 6. Ensure that all connections are secure. 7. Turn on the host system. 8. Select the Keyboard Wedge host type by scanning the appropriate bar code from Keyboard Wedge Host Types on page 6-5. 9. To modify any other parameter options, scan the appropriate bar codes in this chapter.
Keyboard Wedge Parameter Defaults Table 6-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page 6-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 6-1. Keyboard Wedge Host Default Table
Parameter Default Page Number
Keyboard Wedge Host Parameters
Keyboard Wedge Host Type IBM PC/AT& IBM PC Compatibles 6-5
Country Types (Country Codes) North American 6-6
Ignore Unknown Characters Transmit 6-8
Keystroke Delay No Delay 6-8
Intra-Keystroke Delay Disable 6-9
Alternate Numeric Keypad Emulation Disable 6-9
Caps Lock On Disable 6-10
Caps Lock Override Disable 6-10
Convert Wedge Data No Convert 6-11
Function Key Mapping Disable 6-11
FN1 Substitution Disable 6-12
Send and Make Break Send 6-12

Keyboard Wedge Interface 6-5

Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below.

Keyboard Wedge Country Types (Country Codes) Scan the bar code corresponding to the keyboard type. If the keyboard type is not listed, see Alternate Numeric Keypad Emulation on page 6-9.


Keyboard Wedge Interface 6-7


Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then the digital scanner issues an error beep.
Do Not Send Bar Codes with Unknown Characters
Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.
Medium Delay (20 msec)
Long Delay (40 msec)

Keyboard Wedge Interface 6-9
Intra-Keystroke Delay When enabled, an additional delay is inserted between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well.

Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types (Country Codes) on page 6- 6 in a Microsoft® operating system environment.

Caps Lock On When enabled, the digital scanner emulates keystrokes as if the Caps Lock key is always pressed.

Caps Lock Override When enabled, on AT or AT Notebook hosts, the keyboard ignores the state of the Caps Lock key. Therefore, an ‘A’ in the bar code is sent as an ‘A’ no matter what the state of the keyboard’s Caps Lock key.
If both Caps Lock On and Caps Lock Override are enabled, Caps Lock Override takes precedence.

Keyboard Wedge Interface 6-11
Convert Wedge Data When enabled, the digital scanner converts all bar code data to the selected case.

Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 6-2 on page 6-15). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.

FN1 Substitution When this is enabled, the digital scanner replaces FN1 characters in an EAN128 bar code with a keystroke chosen by the user (see FN1 Substitution Values on page 14-8).

Send Make and Break When enabled, the scan codes for releasing a key are not sent.

Keyboard Wedge Interface 6-13
Keyboard Maps The following keyboard maps are provided for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 14-6.

7014 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010

(7013 if double key) (1048 if double key)
(1043 if double key) (1048 if double key)

Keyboard Wedge Interface 6-15
Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and +B is scanned, it is interpreted as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >.
Table 6-2. Keyboard Wedge ASCII Character Set
Code 39 Encode Char.acter Keystroke
1002 $B CTRL B
1003 $C CTRL C
1004 $D CTRL D
1005 $E CTRL E
1006 $F CTRL F
1007 $G CTRL G
1008 $H CTRL H/ BACKSPACE 1
1009 $I CTRL I/ HORIZONTAL TAB 1
1010 $J CTRL J
1011 $K CTRL K
1012 $L CTRL L
1013 $M CTRL M/ ENTER 1
1014 $N CTRL N
1015 $O CTRL O
1016 $P CTRL P
1017 $Q CTRL Q
1018 $R CTRL R
1019 $S CTRL S
1020 $T CTRL T
1021 $U CTRL U
1022 $V CTRL V
1023 $W CTRL W
1024 $X CTRL X
1025 $Y CTRL Y
1026 $Z CTRL Z
1027 %A CTRL [ / ESC 1
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.
Full ASCII · ASCII Value

Code 39 Encode Char.acter Keystroke
1029 %C CTRL ]
1030 %D CTRL 6
1031 %E CTRL -
1033 /A !
1034 /B “
1035 /C #
1036 /D $
1037 /E %
1038 /F &
1039 /G ‘
1040 /H (
1041 /I )
1042 /J *
1043 /K +
1044 /L ,
1046 . .
1058 /Z :
1059 %F ;
1060 %G <
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

Keyboard Wedge Interface 6-17
Code 39 Encode Char.acter Keystroke
1062 %I >
1063 %J ?
1064 %V @
1065 A A
1066 B B
1067 C C
1068 D D
1069 E E
1070 F F
1071 G G
1072 H H
1073 I I
1074 J J
1075 K K
1076 L L
1077 M M
1078 N N
1079 O O
1080 P P
1081 Q Q
1082 R R
1083 S S
1084 T T
1085 U U
1086 V V
1087 W W
1088 X X
1089 Y Y
1090 Z Z
1091 %K [
1092 %L \
1093 %M ]
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.
Full ASCII · ASCII Value

Code 39 Encode Char.acter Keystroke
1095 %O _
1096 %W ‘
1123 %P {
1124 %Q |
1125 %R }
1126 %S ~
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

Keyboard Wedge Interface 6-19
2066 ALT B
2067 ALT C
2068 ALT D
2069 ALT E
2070 ALT F
2071 ALT G
2072 ALT H
2073 ALT I
2074 ALT J
2075 ALT K
2076 ALT L
2077 ALT M
2078 ALT N
2079 ALT O
2080 ALT P
2081 ALT Q
2082 ALT R
2083 ALT S
2084 ALT T
2085 ALT U
2086 ALT V
2087 ALT W
2088 ALT X
2089 ALT Y
2090 ALT Z
Table 6-4. Keyboard Wedge GUI Key Character Set
3000 Right Control Key
3049 GUI 1
3050 GUI 2
3051 GUI 3
3052 GUI 4
ALT Keys Keystroke · GUI Keys Keystrokes

3054 GUI 6
3055 GUI 7
3056 GUI 8
3057 GUI 9
3065 GUI A
3066 GUI B
3067 GUI C
3068 GUI D
3069 GUI E
3070 GUI F
3071 GUI G
3072 GUI H
3073 GUI I
3074 GUI J
3075 GUI K
3076 GUI L
3077 GUI M
3078 GUI N
3079 GUI O
3080 GUI P
3081 GUI Q
3082 GUI R
3083 GUI S
3084 GUI T
3085 GUI U
3086 GUI V
3087 GUI W
3088 GUI X
3089 GUI Y
3090 GUI Z
GUI Keys Keystrokes

Keyboard Wedge Interface 6-21
5002 F2
5003 F3
5004 F4
5005 F5
5006 F6
5007 F7
5008 F8
5009 F9
5010 F10
5011 F11
5012 F12
5013 F13
5014 F14
5015 F15
5016 F16
5017 F17
5018 F18
5019 F19
5020 F20
5021 F21
5022 F22
5023 F23
5024 F24
Table 6-6. Keyboard Wedge Numeric Keypad Character Set

Table 6-7. Keyboard Wedge Extended Keypad Character Set

Introduction 7-3 Connecting an RS-232 Interface 7-4 RS-232 Parameter Defaults 7-5 RS-232 Host Parameters 7-6
RS-232 Host Types 7-8 Baud Rate 7-9 Parity 7-11 Stop Bit Select 7-12 Data Bits 7-12 Check Receive Errors 7-13 Hardware Handshaking 7-14 Hardware Handshaking (continued) 7-15 Software Handshaking 7-16 Host Serial Response Time-out 7-17 RTS Line State 7-18 Beep on 7-18 Intercharacter Delay 7-19 Nixdorf Beep/LED Options 7-20 Ignore Unknown Characters 7-20 ASCII Character Set for RS-232 7-21



Introduction This chapter describes how to set up the digital scanner with an RS-232 host. The RS-232 interface is used to connect the digital scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port).
If the host is not listed in Table 7-2, refer to the documentation for the host device to set communication parameters to match the host.
The digital scanner uses TTL RS-232 signal levels, which interface with most system architectures. For system architectures requiring RS-232C signal levels, Symbol offers different cables providing TTL-to-RS- 232C conversion. Contact the Symbol Support Center for more information.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
*Baud Rate 9600 Feature/Option * Indicates Default
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
RS-232 Interface 7-3

Connecting an RS-232 Interface This connection is made directly from the digital scanner to the host computer.
Serial Port Connector to Host
Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
1. Attach the modular connector of the RS-232 interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Connect the other end of the RS-232 interface cable to the serial port on the host. 3. Connect the power supply to the serial connector end of the RS-232 interface cable. Plug the power supply into an appropriate outlet. 4. Select the RS-232 host type by scanning the appropriate bar code from RS-232 Host Types on page 7-8. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter.
Interface Cable · Power Supply Cable

RS-232 Parameter Defaults Table 7-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the RS- 232 Host Parameters section beginning on page 7-6.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 7-1. RS-232 Host Default Table
Parameter Default Page Number
RS-232 Host Types Standard 7-8
Baud Rate 9600 7-10
Parity Type None 7-11
Stop Bit Select 1 Stop Bit 7-12
Data Bits 8-Bit 7-12
Check Receive Errors Enable 7-13
Hardware Handshaking None 7-15
Software Handshaking None 7-16
Host Serial Response Time-out 2 Sec 7-17
RTS Line State Low RTS 7-18
Beep on Disable 7-18
Intercharacter Delay 0 msec 7-19
Nixdorf Beep/LED Options Normal Operation 7-20
Ignore Unknown Characters Send Bar Code 7-20
RS-232 Interface 7-5 · RS-232 Host Parameters

RS-232 Host Parameters Various RS-232 hosts are set up with their own parameter default settings (Table 7-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below.
Transmit Code ID No Yes
Data as is Data/Suffix Prefix/Data/ Suffix
Suffix CR/LF (7013) CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013)
Baud Rate 9600
Parity None Even None Odd Odd Even None
None RTS/CTS Option 3
None RTS/CTS Option 3
RTS/CTS Option 3 None None
Software Handshaking None Ack/Nak None
Serial Response Time-out 2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec.
Stop Bit Select One
ASCII Format 8-Bit 7-Bit 8-Bit
Beep On <BEL> Disable
Low High Low Low Low = No data to send
Prefix None STX (1003) None
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the digital scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the digital scanner.

RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 7-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.
Nixdorf Mode B/ OPOS/JPOS
UPC-E E E C C C E
EAN-8/JAN-8 FF FF B B B FF
EAN-13/JAN-13 F F A A A F
Code 39 C None M M M C
Codabar N None N N N N
Code 128 L None K K K L
I 2 of 5 I None I I I I
Code 93 None None L L L None
D 2 of 5 H None H H H H
UCC/EAN 128 L None P P P L
MSI None None O O O None
Bookland EAN F F A A A F
Trioptic None
Code 11 None
IATA H None H H None None
Code 32 None

RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes.



Baud Rate Baud rate is the number of bits of data transmitted per second. Set the digital scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.
RS-232 Interface 7-9



Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

Data Bits This parameter allows the digital scanner to interface with devices requiring a 7-bit or 8-bit ASCII protocol.

Check Receive Errors Select whether or not the parity, framing, and overrun of received characters are checked. The parity value of received characters is verified against the parity parameter selected above.
Do Not Check For Received Errors
RS-232 Interface 7-13

Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS).
If Standard RTS/CTS handshaking is not selected, scan data is transmitted as it becomes available. If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence:
During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the digital scanner sounds a transmission error, and the data is discarded.
If the above communication sequence fails, the digital scanner issues an error indication. In this case, the data is lost and must be rescanned.
If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking takes precedence.
The DTR signal is jumpered to the active state.


RS-232 Interface 7-15

Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options.
If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence.
ENQ


Host Serial Response Time-out This parameter specifies how long the digital scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option.
RS-232 Interface 7-17


RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state.
Beep on <BEL> When this parameter is enabled, the digital scanner issues a beep when a character is detected on the RS-232 serial line. is issued to gain a user's attention to an illegal entry or other important event.

Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions.

RS-232 Interface 7-19

Nixdorf Beep/LED Options When Nixdorf Mode B is selected, this indicates when the digital scanner should beep and turn on its LED after a decode.
*Normal Operation (Beep/LED immediately after decode)
Beep/LED After CTS Pulse
Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes with Unknown Characters is selected, all bar code data is send except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character and then an error beep will sound on the digital scanner.
*Send Bar Code (with unknown characters)
Do Not Send Bar Codes (with unknown characters)
Beep/LED After Transmission

ASCII Character Set for RS-232 The values in Table 7-4 can be assigned as prefixes or suffixes for ASCII character data transmission.
Full ASCII Code 39 Encode Character ASCII Character
1001 $A SOH
1002 $B STX
1003 $C ETX
1004 $D EOT
1005 $E ENQ
1006 $F ACK
1007 $G BELL
1008 $H BCKSPC
1009 $I HORIZ TAB
1010 $J LF/NW LN
1011 $K VT
1012 $L FF
1013 $M CR/ENTER
1014 $N SO
1015 $O SI
1016 $P DLE
1017 $Q DC1/XON
1018 $R DC2
1019 $S DC3/XOFF
1020 $T DC4
1021 $U NAK
1022 $V SYN
1023 $W ETB
1024 $X CAN
1025 $Y EM
1026 $Z SUB
1027 %A ESC
1028 %B FS
1029 %C GS
1030 %D RS
1031 %E US
RS-232 Interface 7-21 · Prefix/Suffix Value · 1032 Space Space

Full ASCII Code 39 Encode Character ASCII Character
1034 /B "
1035 /C #
1036 /D $
1037 /E %
1038 /F &
1039 /G ‘
1040 /H (
1041 /I )
1042 /J *
1043 /K +
1044 /L ,
1046. .
1058 /Z :
1059 %F ;
1060 %G <
1061 %H =
1062 %I >
1063 %J ?
1064 %V @
1065 A A
1066 B B
1067 C C

Full ASCII Code 39 Encode Character ASCII Character
1069 E E
1070 F F
1071 G G
1072 H H
1073 I I
1074 J J
1075 K K
1076 L L
1077 M M
1078 N N
1079 O O
1080 P P
1081 Q Q
1082 R R
1083 S S
1084 T T
1085 U U
1086 V V
1087 W W
1088 X X
1089 Y Y
1090 Z Z
1091 %K [
1092 %L \
1093 %M ]
1094 %N ^
1095 %O _
1096 %W `

Full ASCII Code 39 Encode Character ASCII Character
1124 %Q |
1125 %R }
1126 %S ~
7013 ENTER

Introduction 8-3 Connecting a USB Interface 8-3 USB Parameter Defaults 8-4 USB Host Parameters 8-5
USB Device Type 8-5 USB Country Keyboard Types (Country Codes) 8-6 USB Keystroke Delay 8-8 USB CAPS Lock Override 8-8 USB Ignore Unknown Characters 8-9 Emulate Keypad 8-9 USB Keyboard FN 1 Substitution 8-10 Function Key Mapping 8-10 Simulated Caps Lock 8-11 Convert Case 8-11 ASCII Character Set for USB 8-12



Introduction This chapter describes how to set up the digital scanner with a USB host. The digital scanner connects directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting a USB Interface
USB Series A Connector
The digital scanner connects with USB-capable hosts including:
The following operating systems support the digital scanner through USB:
The digital scanner also interfaces with other USB hosts which support USB Human Interface Devices (HID). For more information on USB technology, hosts, and peripheral devices, visit www.symbol.com/usb.
USB Interface 8-3 · Interface Cable

To set up the digital scanner:
Interface cables vary depending on configuration. The connectors illustrated in Figure 8-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
1. Connect the modular connector of the USB interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Plug the series A connector in the USB host or hub, or plug the Plus Power connector in an available port of the IBM SurePOS terminal. 3. Select the USB device type by scanning the appropriate bar code from USB Device Type on page 8-5. 4. On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter. If problems occur with the system, see Troubleshooting on page 3-3.
USB Parameter Defaults Table 8-1 lists the defaults for USB host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 8-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 8-1. USB Host Default Table
Parameter Default Page Number
USB Device Type HID Keyboard Emulation 8-5
USB Country Keyboard Types (Country Codes) North American 8-6
USB Keystroke Delay No Delay 8-8
USB CAPS Lock Override Disable 8-8
USB Ignore Unknown Characters Enable 8-9
Emulate Keypad Disable 8-9
USB FN1 Substitution Disable 8-10
Function Key Mapping Disable 8-10
Simulated Caps Lock Disable 8-11
Convert Case None 8-11
USB Host Parameters


USB Device Type Select the desired USB device type.
When changing USB Device Types, the digital scanner automatically resets. The digital scanner issues the standard startup beep sequences.
USB Interface 8-5

USB Country Keyboard Types (Country Codes) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device.

When changing USB country keyboard types the digital scanner automatically resets. The digital scanner issues the standard startup beep sequences.


USB Interface 8-7

USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.

USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device. When enabled, the case of the data is preserved regardless of the state of the caps lock key. This setting is always enabled for the Japanese, Windows (ASCII) keyboard type and can not be disabled.

USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Do Not Send Bar Codes With Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the host, and an error beep sounds.
*Send Bar Codes with Unknown Characters (Transmit)
Do Not Send Bar Codes with Unknown Characters
Emulate Keypad When enabled, all characters are sent as ASCII sequences over the numeric keypad. For example ASCII A would be sent as “ALT make” 0 6 5 “ALT Break”.

USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device. When enabled, this allows replacement of any FN 1 characters in an EAN 128 bar code with a Key Category and value chosen by the user (see FN1 Substitution Values on page 14-8 to set the Key Category and Key Value).
Function Key Mapping ASCII values under 32 are normally sent as a control-key sequences (see Table 8-2 on page 8-12). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.
*Disable Function Key Mapping
Enable Function Key Mapping
Enable · *Disable

Simulated Caps Lock When enabled, the digital scanner inverts upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion is done regardless of the current state of the keyboard’s Caps Lock state.

Convert Case When enabled, the digital scanner converts all bar code data to the selected case.
USB Interface 8-11

Full ASCII Code 39 Encode Char.acter Keystroke
1001 $A CTRL A
1002 $B CTRL B
1003 $C CTRL C
1004 $D CTRL D
1005 $E CTRL E
1006 $F CTRL F
1007 $G CTRL G
1008 $H CTRL H/ BACKSPACE 1
1009 $I CTRL I/ HORIZONTAL TAB 1
1010 $J CTRL J
1011 $K CTRL K
1012 $L CTRL L
1013 $M CTRL M/ ENTER 1
1014 $N CTRL N
1015 $O CTRL O
1016 $P CTRL P
1017 $Q CTRL Q
1018 $R CTRL R
1019 $S CTRL S
1020 $T CTRL T
1021 $U CTRL U
1022 $V CTRL V
1023 $W CTRL W
1024 $X CTRL X
1025 $Y CTRL Y
1026 $Z CTRL Z
1027 %A CTRL [/ ESC 1
1028 %B CTRL \
1029 %C CTRL ]
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.
Prefix/ Suffix Value

Full ASCII Code 39 Encode Char.acter Keystroke
1031 %E CTRL -
1033 /A !
1034 /B “
1035 /C #
1036 /D $
1037 /E %
1038 /F &
1039 /G ‘
1040 /H (
1041 /I )
1042 /J *
1043 /K +
1044 /L ,
1046 . .
1058 /Z :
1059 %F ;
1060 %G <
1061 %H =
1062 %I >
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

Full ASCII Code 39 Encode Char.acter Keystroke
1064 %V @
1065 A A
1066 B B
1067 C C
1068 D D
1069 E E
1070 F F
1071 G G
1072 H H
1073 I I
1074 J J
1075 K K
1076 L L
1077 M M
1078 N N
1079 O O
1080 P P
1081 Q Q
1082 R R
1083 S S
1084 T T
1085 U U
1086 V V
1087 W W
1088 X X
1089 Y Y
1090 Z Z
1091 %K [
1092 %L \
1093 %M ]
1094 %N ^
1095 %O _
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.
Prefix/ Suffix Value

Full ASCII Code 39 Encode Char.acter Keystroke
1123 %P {
1124 %Q |
1125 %R }
1126 %S ~
1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

2065 ALT A
2066 ALT B
2067 ALT C
2068 ALT D
2069 ALT E
2070 ALT F
2071 ALT G
2072 ALT H
2073 ALT I
2074 ALT J
2075 ALT K
2076 ALT L
2077 ALT M
2078 ALT N
2079 ALT O
2080 ALT P
2081 ALT Q
2082 ALT R
2083 ALT S
2084 ALT T
2085 ALT U
2086 ALT V
2087 ALT W
2088 ALT X
2089 ALT Y
2090 ALT Z
ALT Keys Keystroke

3000 Right Control Key
3049 GUI 1
3050 GUI 2
3051 GUI 3
3052 GUI 4
3053 GUI 5
3054 GUI 6
3055 GUI 7
3056 GUI 8
3057 GUI 9
3065 GUI A
3066 GUI B
3067 GUI C
3068 GUI D
3069 GUI E
3070 GUI F
3071 GUI G
3072 GUI H
3073 GUI I
3074 GUI J
3075 GUI K
3076 GUI L
3077 GUI M
3078 GUI N
3079 GUI O
3080 GUI P
3081 GUI Q
3082 GUI R
3083 GUI S
3084 GUI T
3085 GUI U
3086 GUI V
USB Interface 8-17 · GUI Key Keystroke

3088 GUI X
3089 GUI Y
3090 GUI Z
5002 F2
5003 F3
5004 F4
5005 F5
5006 F6
5007 F7
5008 F8
5009 F9
5010 F10
5011 F11
5012 F12
5013 F13
5014 F14
5015 F15
5016 F16
5017 F17
5018 F18
5019 F19
5020 F20
5021 F21
5022 F22
5023 F23
5024 F24
GUI Key Keystroke · F Keys Keystroke



Introduction 9-3 Connecting to an IBM 468X/469X Host 9-3 IBM Parameter Defaults 9-4 IBM 468X/469X Host Parameters 9-5
Port Address 9-5 Convert Unknown to Code 39 9-6



IBM 468X/469X Interface 9-3
Introduction This chapter describes how to set up the digital scanner with an IBM 468X/469X host.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting to an IBM 468X/469X Host This connection is made directly from the digital scanner to the host interface.
Interface cables vary depending on configuration. The connectors illustrated in Figure 9-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
1. Attach the modular connector of the IBM 46XX interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Connect the other end of the IBM 46XX interface cable to the appropriate port on the host (typically Port 9). 3. Select the port address by scanning the appropriate bar code from Port Address on page 9-5. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter.
Interface Cable · Host Port Connector

The only required configuration is the port address. Other digital scanner parameters are typically controlled by the IBM system.
IBM Parameter Defaults Table 9-1 lists the defaults for IBM host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 9-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 9-1. IBM Host Default Table
Parameter Default Page Number
IBM 468X/469X Host Parameters
Port Address None Selected 9-5
Convert Unknown to Code 39 Disable 9-6

IBM 468X/469X Interface 9-5

Port Address This parameter sets the IBM 468X/469X port used.
Scanning one of these bar codes enables the RS-485 interface on the digital scanner.

Convert Unknown to Code 39 Scan a bar code below to enable or disable the conversion of unknown bar code type data to Code 39.
Enable Convert Unknown to Code 39

Introduction 10-3 Connecting Using Wand Emulation 10-3 Wand Emulation Parameter Defaults 10-4 Wand Emulation Host Parameters 10-5
Wand Emulation Host Types 10-5 Leading Margin (Quiet Zone) 10-6 Polarity 10-7 Ignore Unknown Characters 10-7 Convert All Bar Codes to Code 39 10-8 Convert Code 39 to Full ASCII 10-9



Wand Emulation Interface 10-3
Introduction This chapter describes how to set up the digital scanner with a wand emulation host when Wand Emulation communication is needed. The digital scanner connects to an external wand decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal.
In this mode the digital scanner emulates the signal of a digital wand to make it "readable" by a wand decoder.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
Feature/Option * Indicates Default
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting Using Wand Emulation To perform Wand Emulation, connect the digital scanner to a mobile computer, or a controller which collects the wand data and interprets it for the host.
Wand Port Interface Cable
Interface cables vary depending on configuration. The connectors illustrated in Figure 10-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
Mobile Computer

1. Attach the modular connector of the Wand Emulation interface cable to cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Connect the other end of the Wand Emulation interface cable to the wand port on the mobile computer or controller. 3. Select the Wand Emulation host type by scanning the appropriate bar code from Wand Emulation Host Types on page 10-5. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter.
Connect the digital scanner to 5 volt decoders only. Connecting the digital scanner to a 12 volt decoder can damage the digital scanner and invalidate the warranty.
Wand Emulation Parameter Defaults Table 10-1 lists the defaults for Wand Emulation host types. To change any option, scan the appropriate bar code(s) provided in Wand Emulation Host Parameters on page 10-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 10-1. Wand Emulation Default Table
Parameter Default Page Number
Wand Emulation Host Parameters
Wand Emulation Host Types Symbol OmniLink Interface Controller
Leading Margin 80 msec 10-6
Polarity Bar High/Margin Low 10-7
Ignore Unknown Characters Ignore 10-7
Convert All Bar Codes to Code 39 Disable 10-8
Convert Code 39 to Full ASCII Disable 10-9

Wand Emulation Interface 10-5

Wand Emulation Host Types Select a Wand Emulation host by scanning one of the bar codes below.

Leading Margin (Quiet Zone) Scan a bar code below to select a leading margin duration. A leading margin is the time that precedes the first bar of the scan, (in milliseconds). The minimum allowed value is 80 msec and the maximum is 250 msec. This parameter accommodates older wand decoders which cannot handle short leading margins.

250 msec is the maximum value that this parameter can attain, however, 200 msec is sufficient.

Wand Emulation Interface 10-7
Polarity Polarity determines how the digital scanner's Wand Emulation interface creates the Digitized Barcode Pattern (DBP). DBP is a digital signal that represents the scanned bar code. Different decoders expect the DBP to be in a certain format. The DBP either has the "highs" represent bars and the "lows" represent spaces (margins), or the "highs" represent spaces (margins) and the "lows" represent bars.
Scan the appropriate bar code to select the polarity required by the decoder.
Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the host, and the digital scanner emits an error beep.
Do Not Send Bar Codes With Unknown Characters
Bar Low/Margin High · (Do Not Transmit)

Convert All Bar Codes to Code 39 By default, the Wand Emulation interface sends data to the attached host in the same symbology that was decoded. This can be a problem for customers with older systems that do not recognize newer symbologies (for example, RSS).
Enabling this parameter ignores the original symbology decoded, and outputs the data as if it were a Code 39 bar code. Any lowercase characters in the original data stream are transmitted as uppercase characters. This also allows ADF Formatting.
If Ignore Unknown Characters is enabled, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space.
If Ignore Unknown Characters is disabled, if any characters that do not have a corresponding Code 39 character are encountered, the digital scanner emits an error beep and no data is transmitted.
ADF Note: By default, the Wand Emulation interface does not allow scanned data to be processed by ADF rules. Enabling this parameter allows the scanned data to be processed by ADF rules (Chapter 15, Advanced Data Formatting).
Enable Convert to Code 39 for Wand Host

Wand Emulation Interface 10-9
Convert Code 39 to Full ASCII By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the wand Interface is encoded in Code 39 Full ASCII. This setting requires that the Host be able to interpret Code 39 Full ASCII data.
This setting applies only if Convert to Code 39 is also enabled.
Enable Code 39 Full ASCII Conversion



Introduction 11-3 Connecting Using Scanner Emulation 11-3 Scanner Emulation Parameter Defaults 11-4 Scanner Emulation Host 11-6
Scanner Emulation Host Parameters 11-6 Beep Style 11-6 Parameter Pass-Through 11-7 Convert Newer Code Types 11-7 Module Width 11-8 Convert All Bar Codes to Code 39 11-8 Code 39 Full ASCII Conversion 11-9 Transmission Timeout 11-9 Ignore Unknown Characters 11-10 Leading Margin 11-11 Check For Decode LED 11-12



Scanner Emulation Interface 11-3
Introduction This chapter describes how to set up the digital scanner with a Scanner Emulation host. Use this mode when Scanner Emulation communication is needed. In this mode, the digital scanner connects to an external decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
Feature/Option * Indicates Default
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting Using Scanner Emulation To perform Scanner Emulation, connect the digital scanner to a mobile computer, or a controller which collects the data and interprets it for the host.
Interface cables vary depending on configuration. The connectors illustrated in Figure 11-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
Host Port Connector · Interface Cable

Connect the digital scanner to 5 volt decoders only. Connecting the digital scanner to a 12 volt decoder can damage the digital scanner and invalidate the warranty.
Scanner Emulation Parameter Defaults Table 11-1 lists the defaults for the Scanner Emulation host. To change any option, scan the appropriate bar code(s) provided in the Scanner Emulation Host Parameters section beginning on page 11-6.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Scanner Emulation Interface 11-5
Parameter Default Page Number
Beep Style Beep on Successful Transmit 11-6
Parameter Pass-Through Parameter Process and Pass Through
Convert Newer Code Types Convert Newer Code Types 11-7
Module Width 20 µs 11-8
Convert All Bar Codes to Code 39 Do Not Convert to Bar Codes to Code 39
Code 39 Full ASCII Conversion Disable 11-9
Transmission Timeout 3 seconds 11-9
Ignore Unknown Characters Ignore Unknown Characters 11-10
Leading Margin 2 ms 11-11
Check for Decode LED Check for Decode LED 11-12

Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation host.
Beep Style The Scanner Emulation host supports three beep styles.
In all cases, if an error occurs, the digital scanner issues error beeps.
*Beep On Successful Transmit
Beep At Decode Time
Scanner Emulation Host · Do Not Beep

Scanner Emulation Interface 11-7
Parameter Pass-Through The Scanner Emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once.
For example, to enable D 2 of 5, scan the D 2 of 5 Enable parameter bar code. The digital scanner and the attached decoder both process the parameter.
*Parameter Process and Pass-Through
Convert Newer Code Types The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow compatibility in these environments, the digital scanner converts these code types to more commonly decodable symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally.
Code 11 Code 39
RSS (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF, MaxiCode, DataMatrix, QR Code, Postal Codes, Composite Codes
When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data.
*Convert Newer Code Types
Reject Newer Code Types
Parameter Process Only · Code 128

Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.

Convert All Bar Codes to Code 39 Scan a bar code below to enable or disable the conversion of all bar code data to Code 39.

Scanner Emulation Interface 11-9
Code 39 Full ASCII Conversion By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the Scanner Emulation host is encoded in Code 39 Full ASCII. The host must be able to interpret Code 39 Full ASCII data.
This setting applies only if Convert to Code 39 is also enabled.
*Disable Convert Code 39 To Full ASCII
Enable Convert Code 39 To Full ASCII
Transmission Timeout The Scanner Emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time, the Decode signal is not asserted (indicating that the attached decoder has not successfully received the bar code data), the digital scanner issues transmit error beeps.
Scan the appropriate bar code below to select the desired transmission timeout.
*3 Second Transmission Timeout
4 Second Transmission Timeout
5 Second Transmission Timeout


Ignore Unknown Characters Unknown characters are characters the decoder does not recognize. When Ignore Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Convert Error on Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the decoder, and a convert error beep sounds.

Scanner Emulation Interface 11-11
Leading Margin Scan a bar code below to select a leading margin duration.


Check For Decode LED The attached decoder normally asserts the Decode line to signal to the Scanner Emulation host that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the Decode signal. In this case, the digital scanner emits transmit error beeps to indicate that the bar code was not successfully transmitted. Scan the Ignore Decode LED bar code to disable the Transmit Error beeps.
*Check For Decode LED
Ignore Decode LED

Introduction 12-3 Communication with 123Scan 12-3 123Scan Parameter 12-3

DS 3408 Product Reference Guid 12-2

Introduction 123Scan is a Windows®-based utility that programs the digital scanner with all parameters including Advanced Data Formatting (ADF) Rules. An ADF rule modifies bar code data before it is sent to the host to ensure compatibility between bar coded data and the host application. Digital scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility. Digital scanner programming is saved in a file for electronic distribution. The 123Scan program includes a help file.
Communication with 123Scan To communicate with the 123Scan program which runs on a host computer running a Windows operating system, use an RS-232 cable to connect the digital scanner to the host computer (see Connecting an RS-232 Interface on page 7-4).
123Scan requirements:
123Scan Parameter To communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto the host computer, and scan the bar code below. Refer to 123Scan instructions for programming the digital scanner.
Scan the bar code below to enable the 123Scan interface on the digital scanner.
123 Scan 12-3 · 123Scan Configuration

DS 3408 Product Reference Guid 12-4

Introduction 13-5 Scanning Sequence Examples 13-5 Errors While Scanning 13-5 Symbology Parameter Defaults 13-6 UPC/EAN 13-10
Enable/Disable UPC-A 13-10 Enable/Disable UPC-E 13-10 Enable/Disable UPC-E1 13-11 Enable/Disable EAN-8/JAN-8 13-11 Enable/Disable EAN-13/JAN-13 13-12 Enable/Disable Bookland EAN 13-12 Decode UPC/EAN/JAN Supplementals 13-13 UPC/EAN/JAN Supplemental Redundancy 13-14 Transmit UPC-A Check Digit 13-15 Transmit UPC-E Check Digit 13-15 Transmit UPC-E1 Check Digit 13-16 UPC-A Preamble 13-16 UPC-E Preamble 13-17 UPC-E1 Preamble 13-18 Convert UPC-E to UPC-A 13-18 Convert UPC-E1 to UPC-A 13-19 EAN-8/JAN-8 Extend 13-19 UCC Coupon Extended Code 13-20 Code 128 13-20
Enable/Disable Code 128 13-20

Enable/Disable UCC/EAN-128 13-21 Enable/Disable ISBT 128 13-21 Code 39 13-22
Enable/Disable Trioptic Code 39 13-22 Convert Code 39 to Code 32 13-23 Code 32 Prefix 13-23 Set Lengths for Code 39 13-24 Code 39 Check Digit Verification 13-25 Transmit Code 39 Check Digit 13-26 Code 39 Full ASCII Conversion 13-26 Code 39 Buffering (Scan & Store) 13-27 Code 93 13-29
Enable/Disable Code 93 13-29 Set Lengths for Code 93 13-30 Code 11 13-31
Code 11 13-31 Set Lengths for Code 11 13-32 Code 11 Check Digit Verification 13-33 Transmit Code 11 Check Digits 13-34 Interleaved 2 of 5 (ITF) 13-34
Enable/Disable Interleaved 2 of 5 13-34 Set Lengths for Interleaved 2 of 5 13-35 I 2 of 5 Check Digit Verification 13-36 Transmit I 2 of 5 Check Digit 13-37 Convert I 2 of 5 to EAN-13 13-37 Discrete 2 of 5 (DTF) 13-38
Enable/Disable Discrete 2 of 5 13-38 Set Lengths for Discrete 2 of 5 13-38 Codabar (NW - 7) 13-39
Enable/Disable Codabar 13-39 Set Lengths for Codabar 13-40 CLSI Editing 13-41 NOTIS Editing 13-41 MSI 13-42
Enable/Disable MSI 13-42 Set Lengths for MSI 13-42 MSI Check Digits 13-43 Transmit MSI Check Digit(s) 13-44 MSI Check Digit Algorithm 13-44 Postal Codes 13-45
US Postnet 13-45 US Planet 13-45 UK Postal 13-46 Transmit UK Postal Check Digit 13-46 Japan Postal 13-47 Australian Postal 13-47 Dutch Postal 13-48 Transmit US Postal Check Digit 13-48

RSS (Reduced Space Symbology) 13-49
RSS-14 13-49 RSS Limited 13-49 RSS Expanded 13-50 Convert RSS to UPC/EAN 13-50 Composite 13-51
Composite CC-C 13-51 Composite CC-A/B 13-51 Composite TLC-39 13-52 UPC Composite Mode 13-53 Composite Beep Mode 13-54 UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes 13-54 2D Symbologies 13-55 Enable/Disable PDF417 13-55 Enable/Disable MicroPDF417 13-55 Code 128 Emulation 13-56 Data Matrix 13-57 Maxicode 13-57 QR Code 13-58 Redundancy Level 13-59 Security Level 13-61
Intercharacter Gap Size 13-62 Report Version 13-62 Macro PDF Features 13-63
Flush Macro Buffer 13-63 Abort Macro PDF Entry 13-63
Symbologies 13-3



Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started.
The digital scanner is shipped with the settings shown in the Symbology Default Table on page 13-6 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary.
To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host.
To return all features to default values, scan the *Set All Defaults bar code on page 4-5. Throughout the programming bar code menus, default values are indicated with asterisks (*).
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 13-15. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbologies 13-5

Symbology Parameter Defaults Table 13-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on 13-10.
See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.
Table 13-1. Symbology Default Table
UPC-A 01h Enable 13-10
UPC-E 02h Enable 13-10
UPC-E1 0Ch Disable 13-11
EAN-8/JAN 8 04h Enable 13-11
EAN-13/JAN 13 03h Enable 13-12
Bookland EAN 53h Disable 13-12
Decode UPC/EAN/JAN Supplementals (2 and 5 digits) 10h Ignore 13-13
UPC/EAN/JAN Supplemental Redundancy 50h 10 13-14
Transmit UPC-A Check Digit 28h Enable 13-15
Transmit UPC-E Check Digit 29h Enable 13-15
Transmit UPC-E1 Check Digit 2Ah Enable 13-16
UPC-A Preamble 22h System Character 13-16
UPC-E Preamble 23h System Character 13-16
UPC-E1 Preamble 24h System Character 13-18
Convert UPC-E to A 25h Disable 13-19
Convert UPC-E1 to A 26h Disable 13-19
EAN-8/JAN-8 Extend 27h Disable 13-19
UCC Coupon Extended Code 55h Disable 13-20
Code 128 08h Enable 13-20
UCC/EAN-128 0Eh Enable 13-21
ISBT 128 54h Enable 13-21

Code 39 00h Enable 13-22
Trioptic Code 39 0Dh Disable 13-22
Convert Code 39 to Code 32 (Italian Pharmacy Code) 56h Disable 13-23
Code 32 Prefix E7h Disable 13-23
Set Length(s) for Code 39 12h 13h 2 to 55 13-24
Code 39 Check Digit Verification 30h Disable 13-25
Transmit Code 39 Check Digit 2Bh Disable 13-26
Code 39 Full ASCII Conversion 11h Disable 13-26
Buffer Code 39 71h Disable 13-27
Code 93 09h Disable 13-29
Set Length(s) for Code 93 1Ah 1Bh 4 to 55 13-30
Code 11 0Ah Disable 13-31
Set Lengths for Code 11 1Ch 1Dh 4 to 55 13-32
Code 11 Check Digit Verification 34h Disable 13-33
Transmit Code 11 Check Digit(s) 2Fh Disable 13-34
Interleaved 2 of 5 (ITF)
Interleaved 2 of 5 (ITF) 06h Enable 13-34
Set Lengths for I 2 of 5 16h 17h 14 13-35
I 2 of 5 Check Digit Verification 31h Disable 13-36
Transmit I 2 of 5 Check Digit 2Ch Disable 13-37
Convert I 2 of 5 to EAN 13 52h Disable 13-37
Discrete 2 of 5 (DTF)
Discrete 2 of 5 05h Disable 13-38
Set Length(s) for D 2 of 5 14h 15h 12 13-38

Codabar (NW - 7)
Codabar 07h Disable 13-39
Set Lengths for Codabar 18h 19h 5 to 55 13-40
CLSI Editing 36h Disable 13-41
NOTIS Editing 37h Disable 13-41
MSI 0Bh Disable 13-42
Set Length(s) for MSI 1Eh 1Fh 1 to 55 13-42
MSI Check Digits 32h One 13-43
Transmit MSI Check Digit 2Eh Disable 13-44
MSI Check Digit Algorithm 33h Mod 10/Mod 10 13-44
US Postnet 59h Enable 13-45
US Planet 5Ah Enable 13-45
UK Postal 5Bh Enable 13-46
Transmit UK Postal Check Digit 60h Enable 13-46
Japan Postal F0h 22h Enable 13-47
Australian Postal F0h 23h Enable 13-47
Dutch Postal F0h 46h Enable 13-48
Transmit US Postal Check Digit 5Fh Enable 13-48
RSS (Reduced Space Symbology)
RSS 14 F0h 52h Enable 13-49
RSS Limited F0h 53h Enable 13-49
RSS Expanded F0h 54h Enable 13-50
Convert RSS to UPC/EAN F0h 8Dh Disable 13-50
Composite CC-C F0h 55h Disable 13-51
Composite CC-A/B F0h 56h Disable 13-51

Composite TLC-39 F0h 73h Disable 13-52
UPC Composite Mode F0h 58h Always Linked 13-53
Composite Beep Mode F0h 8Eh Beep As Each Code Type is Decoded
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes
F0h ABh Disable 13-54
PDF417 0Fh Enable 13-55
MicroPDF417 E3h Disable 13-55
Code 128 Emulation 7Bh Disable 13-56
Data Matrix F0h 24h Enable 13-57
Maxicode F0h 26h Enable 13-57
QR Code F0h 25h Enable 13-58
Redundancy Level 4Eh 1 13-59
Security Level 4Dh 0 13-61
Intercharacter Gap Size F0h 7Dh Normal 13-62
Flush Macro PDF Buffer 13-63
Abort Macro PDF Entry 13-63


To enable or disable UPC-A, scan the appropriate bar code below.
To enable or disable UPC-E, scan the appropriate bar code below.


To enable or disable UPC-E1, scan the appropriate bar code below.
UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
Symbologies 13-11


To enable or disable EAN-13/JAN-13, scan the appropriate bar code below.
Parameter # 53h To enable or disable Bookland EAN, scan the appropriate bar code below.

Parameter # 10h Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available.
To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters.

Decode UPC/EAN/JAN Only With Supplementals

Enable 378/379 Supplemental Mode
Enable 978 Supplemental Mode
Enable Smart Supplemental Mode
Parameter # 50h With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN/JAN symbols with and without supplementals, and the autodiscriminate option is selected. The default is set at 10.
Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar codes in Appendix D, Numeric Bar Codes. Single digit numbers must have a leading zero. To correct an error or change a selection, scan Cancel on page D-4.


Parameter # 28h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-A check digit. It is always verified to guarantee the integrity of the data.
Do Not Transmit UPC-A Check Digit
Parameter # 29h The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data.
Do Not Transmit UPC-E Check Digit
Symbologies 13-15 · (00h) · (00h)

Parameter # 2Ah The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data.
Do Not Transmit UPC-E1 Check Digit
Parameter # 22h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-A preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Parameter # 23h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Parameter # 24h Preamble characters are part of the UPC symbol, and include Country Code and System Character. There are three options for transmitting a UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and transmit no preamble. Select the appropriate option to match the host system.
System Character & Country Code (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)
Parameter # 25h Enable this to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
When disabled, UPC-E decoded data is transmitted as UPC-E data, without conversion.
Convert UPC-E to UPC-A (Enable)


Parameter # 26h Enable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
When disabled, UPC-E1 decoded data is transmitted as UPC-E1 data, without conversion.
Parameter # 27h When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
Symbologies 13-19


Parameter # 55h When enabled, this parameter decodes UPC-A bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPC- A/EAN-128 Coupon Codes. UPCA, EAN-13, and EAN-128 must be enabled to scan all types of Coupon Codes.
Use the Decode UPC/EAN Supplemental Redundancy parameter to control autodiscrimination of the EAN128 (right half) of a coupon code.
Parameter # 08h To enable or disable Code 128, scan the appropriate bar code below.

Parameter # 0Eh To enable or disable UCC/EAN-128, scan the appropriate bar code below.
Enable/Disable ISBT 128
Parameter # 54h ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan a bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data.

*Enable ISBT 128 (01h)



Parameter # 00h To enable or disable Code 39, scan the appropriate bar code below.
Parameter # 0Dh Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.


Parameter # 56h Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32.
Code 39 must be enabled for this parameter to function.
Parameter # E7h Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes.
Convert Code 39 to Code 32 must be enabled for this parameter to function.
Symbologies 13-23

Parameter # L1 = 12h, L2 = 13h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options.
When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero.

Code 39 - One Discrete Length
Code 39 - Two Discrete Lengths


Code 39 - Length Within Range

Code 39 - Any Length
Parameter # 30h
When this feature is enabled, the digital scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only Code 39 symbols which include a modulo 43 check digit are decoded. Enable this feature if the Code 39 symbols contain a Modulo 43 check digit.
Enable Code 39 Check Digit
Symbologies 13-25 · (01h)

Parameter # 2Bh Scan a bar code below to transmit Code 39 data with or without the check digit.
Transmit Code 39 Check Digit (Enable)
Code 39 Check Digit Verification must be enabled for this parameter to function.
Code 39 Full ASCII Conversion
Parameter # 11h Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below.
Enable Code 39 Full ASCII
Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the ASCII Character Set Table for the appropriate interface. See the ASCII Character Set for Keyboard Wedge on page 6-15, the ASCII Character Set for USB on page 8-12, or the ASCII Character Set for RS-232 on page 7-21.
(01h) · (01h)

Parameter # 71h This feature allows the digital scanner to accumulate data from multiple Code 39 symbols.
Selecting the Scan and Store option (Buffer Code 39) temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission. The leading space is not buffered.
Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further details.
When the Do Not Buffer Code 39 option is selected, all decoded Code 39 symbols are transmitted immediately without being stored in the buffer.
This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the digital scanner to decode Code 39 symbology only.
Buffer Code 39 (Enable)
While there is data in the transmission buffer, selecting Do Not Buffer Code 39 is not allowed. The buffer holds 200 bytes of information.
To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmit Buffer on page 13-28) or clear the buffer.
Buffer Data To buffer data, Code 39 buffering must be enabled and a Code 39 symbol must be read with a space immediately following the start pattern.
Symbologies 13-27 · (01h)

Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character.
The Clear Buffer contains only the dash (minus) character. In order to scan this command, be sure Code 39 length is set to include length 1.
Transmit Buffer There are two methods to transmit the Code 39 buffer.
Clear Buffer · Transmit Buffer

Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read results in an overflow of the transmission buffer:
Attempt to Transmit an Empty Buffer If the symbol just read was the Transmit Buffer symbol and the Code 39 buffer is empty:
Enable/Disable Code 93
Parameter # 09h To enable or disable Code 93, scan the appropriate bar code below.
Symbologies 13-29 · Enable Code 93 · (01h)

Parameter # L1 = 1Ah, L2 = 1Bh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range.


Parameter # 0Ah To enable or disable Code 11, scan the appropriate bar code below.
Symbologies 13-31

Parameter # L1 = 1Ch, L2 = 1Dh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range.
Code 11 - One Discrete Length
Code 11 - Two Discrete Lengths
Code 11 - Length Within Range
Code 11 - Any Length

Parameter # 34h This feature allows the digital scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature.
To enable this feature, scan the bar code below corresponding to the number of check digits encoded in the Code 11 symbols.


Parameter # 2Fh This feature selects whether or not to transmit the Code 11 check digit(s).
Code 11 Check Digit Verification must be enabled for this parameter to function.
Parameter # 06h To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages.

Parameter # L1 = 16h, L2 = 17h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for I 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range.
Due to the construction of the I 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (I 2 of 5 - One Discrete Length - Two Discrete Lengths) for I 2 of 5 applications.
I 2 of 5 - One Discrete Length
I 2 of 5 - Two Discrete Lengths
Symbologies 13-35

I 2 of 5 - Length Within Range
I 2 of 5 - Any Length
Parameter # 31h When this feature is enabled, the digital scanner checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.





Parameter # 2Ch Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit.
Parameter # 52h Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13. To accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid EAN-13 check digit.
Symbologies 13-37

Enable/Disable Discrete 2 of 5
Parameter # 05h To enable or disable Discrete 2 of 5, scan the appropriate bar code below.
Enable Discrete 2 of 5
Set Lengths for Discrete 2 of 5
Parameter # L1 = 14h, L2 = 15h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range.
Due to the construction of the D 2 of 5 symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (D 2 of 5 - One Discrete Length - Two Discrete Lengths) for D 2 of 5 applications.
(01h)


Parameter # 07h To enable or disable Codabar, scan the appropriate bar code below.
Symbologies 13-39

Parameter # L1 = 18h, L2 = 19h The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Codabar to any length, one or two discrete lengths, or lengths within a specific range.

Codabar - One Discrete Length
Codabar - Two Discrete Lengths

Codabar - Length Within Range

Codabar - Any Length


Parameter # 36h When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
Symbol length does not include start and stop characters.
Parameter # 37h When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enable this feature if the host system requires this data format.
Symbologies 13-41

Enable/Disable MSI
Parameter # 0Bh To enable or disable MSI, scan the appropriate bar code below.
Set Lengths for MSI
Parameter # L1 = 1Eh, L2 = 1Fh The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range.
Due to the construction of the MSI symbology, it is possible for a scan line covering only a portion of the code to be interpreted as a complete scan, yielding less data than is encoded in the bar code. To prevent this, select specific lengths (MSI - One Discrete Length - Two Discrete Lengths) for MSI applications.
Enable MSI · (01h)


Parameter # 32h With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit.
See MSI Check Digit Algorithm on page 13-44 for the selection of second digit algorithms.
Symbologies 13-43


Parameter # 2Eh Scan a bar code below to transmit MSI data with or without the check digit.
Parameter # 33h Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode the check digit.

US Postnet
Parameter # 59h To enable or disable US Postnet, scan the appropriate bar code below.
*Enable US Postnet (01h)
Parameter # 5Ah To enable or disable US Planet, scan the appropriate bar code below.

*Enable US Planet (01h)


Parameter # 5Bh To enable or disable UK Postal, scan the appropriate bar code below.

*Enable UK Postal (01h)

Parameter # 60h Select whether to transmit UK Postal data with or without the check digit.
*Transmit UK Postal Check Digit
Do Not Transmit UK Postal Check Digit


Parameter # F0h, 22h To enable or disable Japan Postal, scan the appropriate bar code below.
Parameter # F0h, 23h To enable or disable Australian Postal, scan the appropriate bar code below.
Symbologies 13-47


Parameter # F0h, 46h To enable or disable Dutch Postal, scan the appropriate bar code below.
Parameter # 5Fh Select whether to transmit US Postal data with or without the check digit.

RSS (Reduced Space Symbology) The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and expanded versions have stacked variants. Scan the appropriate bar code below to enable or disable each variant of RSS.

Symbologies 13-49

RSS Expanded Parameter # F0h 54h.
*Enable RSS Expanded (01h)
Parameter # F0h, 8Dh This parameter only applies to RSS-14 and RSS Limited symbols not decoded as part of a Composite symbol. Enable this to strip the leading '010' from RSS-14 and RSS Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13.
For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and country code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped.
Enable Convert RSS to UPC/EAN
Disable RSS Expanded · (00h) · (01h)


Parameter # F0h 55h Scan a bar code below to enable or disable Composite bar codes of type CC-C.
Parameter # F0h 56h Scan a bar code below to enable or disable Composite bar codes of type CC-A/B.
Symbologies 13-51

Parameter # F0h 73h Scan a bar code below to enable or disable Composite bar codes of type TLC-39.
Enable TLC39 · (01h) · *Disable TLC39 (00h)

Parameter # F0h 58h UPC symbols can be “linked” with a 2D symbol during transmission as if they were one symbol. There are three options for these symbols:
*UPC Always Linked (01h)


Parameter # F0h, 8Eh To select the number of decode beeps when a composite bar code is decoded, scan the appropriate bar code.
Parameter # F0h, ABh Select whether to enable or disable this mode.
*Disable UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes

Enable/Disable PDF417
Parameter # 0Fh To enable or disable PDF417, scan the appropriate bar code below.


Parameter # E3h To enable or disable MicroPDF417, scan the appropriate bar code below.



Parameter # 7Bh When this parameter is enabled, the scanner transmits data from certain MicroPDF417 symbols as if it was encoded in Code 128 symbols. Transmit AIM Symbology Identifiers must be enabled for this parameter to work.
If Code 128 Emulation is enabled, these MicroPDF417 symbols are transmitted with one of the following prefixes:
]C1 if the first codeword is 903-907, 912, 914, 915
]C2 if the first codeword is 908 or 909
]C0 if the first codeword is 910 or 911
If disabled, they are transmitted with one of the following prefixes:
]L3 if the first codeword is 903-907, 912, 914, 915
]L4 if the first codeword is 908 or 909
]L5 if the first codeword is 910 or 911
Scan a bar code below to enable or disable Code 128 Emulation.

Enable Code 128 Emulation

*Disable Code 128 Emulation (00h)
(01h)


Parameter # F0h, 24h To enable or disable Data Matrix, scan the appropriate bar code below.
Parameter # F0h, 26h To enable or disable Maxicode, scan the appropriate bar code below.
Symbologies 13-57

Parameter # F0h,25h To enable or disable QR Code, scan the appropriate bar code below.
*Enable QR Code (01h)
Disable QR Code · (00h)

Redundancy Level Parameter # 4Eh The digital scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the digital scanner’s aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1 The following code types must be successfully read twice before being decoded:
Code Type Code Length
Codabar 8 characters or less
MSI 4 characters or less
D 2 of 5 8 characters or less
I 2 of 5 8 characters or less
Redundancy Level 2 The following code types must be successfully read twice before being decoded:
Code Type Code Length
Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:
Code Type Code Length
MSI Plessey 4 characters or less
D 2 of 5 8 characters or less
I 2 of 5 8 characters or less
Codabar 8 characters or less
Redundancy Level 4 The following code types must be successfully read three times before being decoded:
Code Type Code Length
Symbologies 13-59 · All All · All All



Parameter # 4Dh The digital scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and digital scanner aggressiveness, so choose only that level of security necessary for any given application.
*Security Level 0 (00h)


Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the digital scanner from decoding the symbol. If this problem occurs, scan the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
Report Version Scan the bar code below to report the version of software currently installed in the digital scanner.

Macro PDF Features Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The digital scanner can decode symbols that are encoded with this feature, and can store more than 64 kb of decoded data stored in up to 50 MacroPDF symbols.
When printing, keep each Macro PDF sequence separate, as each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data. When scanning Macro PDF sequences, scan the entire Macro PDF sequence without interruption. If, when scanning a mixed sequence, the digital scanner emits two long low beeps (Lo Lo) this indicates an inconsistent file ID or inconsistent symbology error.
Flush Macro Buffer This flushes the buffer of all decoded Macro PDF data stored to that point, transmits it to the host device, and aborts from Macro PDF mode.

Flush Macro PDF Buffer
Abort Macro PDF Entry This clears all currently-stored Macro PDF data in the buffer without transmission and aborts from Macro PDF mode.

Abort Macro PDF Entry
Symbologies 13-63



Introduction 14-3 Scanning Sequence Examples 14-3 Errors While Scanning 14-3 Miscellaneous Scanner Parameter Defaults 14-4 Miscellaneous Scanner Parameters 14-5
Transmit Code ID Character 14-5 Prefix/Suffix Values 14-6 Scan Data Transmission Format 14-7 FN1 Substitution Values 14-8 Transmit “No Read” Message 14-9 Synapse Interface 14-10



Miscellaneous Scanner Options 14-3
Introduction This chapter includes commonly used bar codes to customize how data is transmitted to the host device. See Chapter 15, Advanced Data Formatting for further customization options.
The digital scanner ships with the settings shown in the Miscellaneous Scanner Options Default Table on page 14-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit requirements, programming is not necessary.
To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down.
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
If not using a Synapse or USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host.
To return all features to default values, scan the *Set All Defaults bar code on page 4-5. Throughout the programming bar code menus, default values are indicated with asterisks (*).

Feature/Option * Indicates Default
Scanning Sequence Examples In most cases, scan one bar code to set a specific parameter value. Other parameters, such as Prefix Value, require scanning several bar codes. See each parameter for descriptions of this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Hex Value

Miscellaneous Scanner Parameter Defaults Table 14-1 lists the defaults for miscellaneous scanner options parameters. To change any option, scan the appropriate bar code(s) provided in the Miscellaneous Scanner Parameters on page 14-5.
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 14-1. Miscellaneous Scanner Options Default Table
Transmit Code ID Character 2Dh None 14-5
Prefix Value 63h, 69h 7013 14-6
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah 7013 14-6
Scan Data Transmission Format EBh Data as is 14-7
FN1 Substitution Values 67h, 6Dh Set 14-8
Transmit “No Read” Message 5Eh Disable 14-9
Synapse Interface F0h ACh Standard 14-10

Miscellaneous Scanner Options 14-5
Transmit Code ID Character
Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when the digital scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol.
Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-3 and AIM Code Identifiers on page B-4.

Symbol Code ID Character

AIM Code ID Character

(02h) · (01h)

Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E- 3 for the four-digit codes.
When using host commands to set the prefix or suffix , set the key category parameter to 1, then set the 3-digit decimal value. See Table E-1 on page E-3 for the four-digit codes.
To correct an error or change a selection, scan Cancel on page D-4.
To use Prefix/Suffix values, first set the Scan Data Transmission Format on page 14-7.




Miscellaneous Scanner Options 14-7
Parameter # EBh To change the scan data format, scan one of the following eight bar codes corresponding to the desired format.
If using this parameter do not use ADF rules to set the prefix/suffix.
To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 14-6.

*Data As Is (00h)








FN1 Substitution Values
Key Category Parameter # 67h Decimal Value Parameter # 6Dh
The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key).
When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the ASCII Character Set table for the currently installed host interface for the desired value.
To select a FN1 substitution value via bar code menus:
Set FN1 Substitution Value
To enable FN1 substitution for keyboard wedge, scan the Enable FN1 Substitution bar code on page 6-12.
To enable FN1 substitution for USB HID keyboard, scan the Enable FN1 Substitution bar code on page 8-10.
(05h) · (06h) · (07h)

Miscellaneous Scanner Options 14-9
Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.

Enable No Read · (01h)

Parameter # F0h, ACh The auto-detection of a Synapse cable varies in duration depending on the type of Synapse connection. If a digital scanner is connected to another scanner using a Synapse cable, use the Auxiliary Synapse Port connection. In all other cases, where the cable is used, the default setting is recommended.
To disconnect and reconnect the digital scanner from a Synapse cable that is connected to a live host via a Synapse, use the "Plug and Play" setting. Do not change this setting from the default if an on-board wedge host is enabled.
*Standard Synapse Connection (01h)
Auxiliary Synapse Port Connection
“Plug and Play” Synapse Connection
(32h) · (0Ah)

Introduction 15-3 Rules: Criteria Linked to Actions 15-3 Using ADF Bar Codes 15-4 ADF Bar Code Menu Example 15-4
Rule 1: The Code 128 Scanning Rule 15-5 Rule 2: The UPC Scanning Rule 15-5 Alternate Rule Sets 15-5 Rules Hierarchy (in Bar Codes) 15-6 Default Rules 15-7 Special Commands 15-8
Pause Duration 15-8 Begin New Rule 15-8 Save Rule 15-8 Erase 15-9 Quit Entering Rules 15-9 Disable Rule Set 15-10 Criteria 15-11
Code Types 15-11 Code Lengths 15-17 Message Containing A Specific Data String 15-22 Actions 15-27
Send Data 15-27 Setup Field(s) 15-30 Modify Data 15-36 Pad Data with Spaces 15-37 Pad Data with Zeros 15-41

Beeps 15-46 Send Keystroke (Control Characters and Keyboard Characters) 15-46 Send Right Control Key 15-82 Send Graphic User Interface (GUI) Characters 15-83 Turn On/Off Rule Sets 15-88 Alphanumeric Keyboard 15-90

Advanced Data Formatting 15-3
Introduction Advanced Data Formatting (ADF) is a means of customizing data before transmission to the host device. Scan data can be edited to suit particular requirements.
ADF can be implemented through scanning a related series of bar codes, which begin on page 15-8, or by installing the 123Scan utility (see Chapter 12, 123 Scan) which allows the digital scanner to be setup and programmed with Advanced Data Formatting (ADF) Rules.
Avoid using ADF formatting with bar codes containing more than 60 characters. To add a prefix or suffix value for such bar codes, use Add Prefix/Suffix setting. Using ADF with longer bar codes transmits the bar code in segments of length 252 or less (depending on the host selected), and applies the rule to each segment
If using the Wand interface with the digital scanner, in order to use ADF rules to format data, first enable Convert All Bar Codes to Code 39 on page 10-8.
Rules: Criteria Linked to Actions In ADF, data is customized through rules. These rules perform detailed actions when the data meets certain criteria. One rule may consist of single or multiple criteria applied to single or multiple actions.
For instance, a data formatting rule could be the following:
Criteria: When scan data is Code 39, length 12, and data at the start position is the string “129”,
Actions: pad all sends with zeros to length 8, send all data up to X, send a space.
If a Code 39 bar code of 1299X1559828 is scanned, the following is transmitted: 00001299. If a Code 39 bar code of 1299X15598 is scanned, this rule is ignored because the length criteria has not been met.
The rule specifies the editing conditions and requirements before data transmission occurs.

Using ADF Bar Codes When programming a rule, make sure the rule is logically correct. Plan ahead before scanning.
To program each data formatting rule:
Beeper Definitions on page 2-4 guide through the programming steps.
ADF Bar Code Menu Example This section provides an example of how ADF rules are entered and used for scan data.
An auto parts distribution center wants to encode manufacturer ID, part number, and destination code into their own Code 128 bar codes. The distribution center also has products that carry UPC bar codes, placed there by the manufacturer. The Code 128 bar codes have the following format:
P = Part Number
D = Destination Code
The distribution center uses a PC with dedicated control characters for manufacturer ID , part number , and destination code . At this center the UPC data is treated as manufacturer ID code.
The following rules need to be entered:
When scanning data of code type Code 128, send the next 5 characters, send the manufacturer ID key , send the next 5 characters, send the part number key , send the next 2 characters, send the destination code key .
When scanning data of code type UPC/EAN, send all data, send the manufacturer ID key .
To enter these rules, follow the steps below:

Advanced Data Formatting 15-5
1 Begin New Rule 15-8 High High
2 Code 128 15-11 High High
3 Send next 5 characters 15-28 High High
4 Send 15-48 High High
5 Send next 5 characters 15-28 High High
6 Send 15-48 High High
7 Send next 2 characters 15-27 High High
8 Send 15-47 High High
9 Save Rule 15-8 High Low High Low
1 Begin New Rule 15-8 High High
2 UPC/EAN 15-12 High High
3 Send all remaining data 15-27 High High
4 Send 15-48 High High
5 Save Rule 15-8 High Low High Low
To correct any errors made while entering this rule, scan the Quit Entering Rules bar code on page 15-9. If the rule is already saved, scan the Erase Previously Saved Rule bar code on page 15-9.
Alternate Rule Sets ADF rules may be grouped into one of four alternate sets which can be turned on and off when needed. This is useful to format the same message in different ways. For example, a Code 128 bar code contains the following information:
Class (2 digits), Stock Number (8) digits, Price (5 digits)
This bar code might look like this:
where:
Stock Number = 56712437
Ordinarily, data is sent as follows:
But, when there is a sale, send only the following:

and the cashier will key the price manually.
To implement this, first enter an ADF rule that applies to the normal situation, such as:
Scan Rule Belongs to Set 1. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, send the data that remains, send the Enter key.
The “sale” rule may look like this:
Scan Rule Belongs to Set 2. When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key.
To switch between the two sets of rules, a “switching rule” must be programmed. This rule specifies what type of bar code must be scanned to switch between the rule sets. For example, in the case of the “sale” rule above, the rule programmer wants the cashier to scan the bar code “M” before a sale. To do this, a rule can be entered as follows:
When scanning a bar code of length 1 that begins with “M”, select rule set number 1.
Another rule could be programmed to switch back.
When scanning a bar code of length 1 that begins with “N”, turn off rule set number 1.
The switching back to normal rules can also be done in the “sale” rule. For example, the rule may look like this:
When scanning a bar code of length 15, send the next 2 characters, send the class key, send the next 8 characters, send the stock key, turn off rule set 1.
For optimal results, scan the Disable All Rule Sets bar code on page 15-10 after programming a rule belonging to an alternate rule set.
In addition to enabling and disabling rule sets within the rules, enable or disable them by scanning the appropriate bar codes on 15-10.
Rules Hierarchy (in Bar Codes) The order of programming individual rules is important.The most general rule should be programmed last.
All programmed rules are stored in a buffer. As they are programmed, they are stored at the “top” of a rules list. If three rules have been created, the list would be configured as follows:
When data is scanned, the rules list is checked from top to bottom to determine if the criteria matches (and therefore, if the actions should occur). Input is modified into the data format specified by the first matching set of criteria it finds. Be sure to program the most general rule last.
For example, if the THIRD rule states:
When scanning a bar code of any length, send all data, then send the ENTER key.
And the SECOND rule states:
When scanning a Code 128 bar code of length 12, send the first four characters, then send the ENTER key, then send all remaining data.
If a Code 128 bar code of length 12 were scanned, the THIRD rule would be in effect. The SECOND rule would appear to not function.
Third Rule · Second Rule · First Rule

Advanced Data Formatting 15-7
These rules reside in the same “rule list” as ADF Rules, so the order of their creation is also important.
Default Rules Every unit has a default rule to send all scan data. Units with custom software may have one or more default rules burned in. The rules hierarchy checks user programmable rules first, then the default rules. Default rules can be disabled by entering the following general rule in the user programmable buffer:
When receiving scan data, send all data.
Since this rule always applies, ADF will never go into the default rules.

Pause Duration This parameter along with the Send Pause parameter on page 15-31 allows a pause to be inserted in the data transmission. Pauses are set by scanning a two-digit number (i.e., two bar codes), and are measured in 0.1 second intervals. For example, scanning bar codes “0” and “1” inserts a 0.1 second pause; “0” and “5” inserts a 0.5 second delay. See Appendix D, Numeric Bar Codes. To correct an error or change a selection, scan Cancel on page D-4.

Begin New Rule Scan this bar code to start entering a new rule
Save Rule Scan this bar code to save the rule.
Pause Duration · Begin New Rule · Save Rule

Advanced Data Formatting 15-9
Erase Use these bar codes to erase criteria, actions, or rules.
Erase Criteria And Start Again
Erase Actions And Start Again
Erase Previously Saved Rule
Quit Entering Rules Scan this bar code to quit entering rules.
Erase All Rules · Quit Entering Rules

Disable Rule Set Use these bar codes to disable rule sets.
Disable Rule Set 1
Disable Rule Set 2
Disable Rule Set 3
Disable Rule Set 4
Disable All Rule Sets

Advanced Data Formatting 15-11
Code Types Select any number of code types to be affected. All selected codes must be scanned in succession, prior to selecting other criteria. To select all code types, do not scan any code type.
Scan the bar codes for all code types desired before selecting other criteria.









Code 93

Advanced Data Formatting 15-13

UPC-E1



Advanced Data Formatting 15-15



When selecting composite bar codes, enable AIM IDs if parsing UPC or EAN composite data, or data from an application that uses symbol separators.

Advanced Data Formatting 15-17
Code Lengths Define the number of characters the selected code type must contain. Do not select any code length to select code types of any length.
Scan these bar codes to define the number of characters the selected code types must contain. Select one length per rule only.


Advanced Data Formatting 15-19


Advanced Data Formatting 15-21
28 Characters · 29 Characters · 30 Characters

Message Containing A Specific Data String Use this feature to select whether the formatting affects data that begins with a specific character or data string, or contains a specific character or data string.
There are 4 features:
Specific String at Start Scan this bar code, then scan the bar codes representing the desired character or characters (up to a total of 8) in the Alphanumeric Keyboard on page 15-90.
After scanning the following bar code:

Specific String At Start

Advanced Data Formatting 15-23
Specific String, Any Location Scan this bar code, then, using the Numeric Keypad on page 15-24, scan a two-digit number representing the position (use a leading “zero” if necessary). Then scan the desired character or characters (up to a total of 8) on the Alphanumeric Keyboard on page 15-90, followed by the End of Message bar code on page 15-99.
After scanning the following bar code:
Specific String Any Location
Any Message OK By not scanning any bar code, all selected code types are formatted, regardless of information contained.

Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard.

Advanced Data Formatting 15-25
Cancel

Rule Belongs To Set Select the set a rule belongs to. (There are four possible rule sets.) See Alternate Rule Sets on page 15-5 for more information about rule sets.
Scan a bar code below to select which set a rule belongs to.
Rule Belongs To Set 1
Rule Belongs To Set 2
Rule Belongs To Set 3
Rule Belongs To Set 4

Advanced Data Formatting 15-27
Actions Select how to format the data for transmission.
Send Data Send all data that remains, send all data up to a specific character selected from the Alphanumeric Keyboard on page 15-90, or send the next N characters. N = any number from 1 to 254, selected from the Alphanumeric Keyboard. Use these bar codes to send data.
Send Data Up To Character
Send All Data That Remains
Send Next 2 Characters
Send Next 3 Characters
Send Next 4 Characters
Send Next Character

Send Next 5 Characters
Send Next 6 Characters
Send Next 7 Characters
Send Next 8 Characters
Send Next 9 Characters

Send Next 10 Characters

Send Next 11 Characters

Advanced Data Formatting 15-29

Send Next 12 Characters

Send Next 13 Characters

Send Next 14 Characters

Send Next 15 Characters
Send Next 16 Characters
Send Next 17 Characters
Send Next 18 Characters

Send Next 19 Characters
Send Next 20 Characters
Scan the Move Cursor To Character bar code on page 15-31, then any printable ASCII character from the Alphanumeric Keyboard. When this is used, the cursor moves to the position after the matching character. If the character is not there, the rule fails and ADF tries the next rule.
Move Cursor To a Character
Move Cursor to Start of Data Scan this bar code to move cursor to the beginning of the data. 15-31
This parameter moves the cursor past all sequential occurrences of a selected character. For example, if the selected character is ‘A’, then the cursor moves past ‘A’, ‘AA’, ‘AAA’, etc. Scan the Move Cursor Past Character bar code on page 15-31, then select a character from the Alphanumeric Keyboard. If the character is not there, the cursor does not move (i.e., has no effect).
Move Cursor Past a Character
Skip Ahead “N” Characters Scan one of these bar codes to select the number of positions ahead to move the cursor.
Skip Back “N” Characters Scan one of these bar codes to select the number of positions back to move the cursor.
Send Values 1 through 6 by scanning the appropriate bar code. These values must be set using the prefix/suffix values in Table 7-4 on page 7-21. Value 1 = Scan Suffix Value 2 = Scan Prefix Values 3-6 are not applicable
Parameter Description Page · Move Cursor · Send Preset Value

Advanced Data Formatting 15-31
Move Cursor Scan a bar code below to move the cursor in relation to a specified character. Then enter a character by scanning a bar code from the Alphanumeric Keyboard beginning on page 15-90.
If there is no match when the rule is interpreted and the rule fails, the next rule is checked.
Move Cursor To Character
Move Cursor To Start
Move Cursor Past Character
Send Pause Scan the bar code below to insert a pause in the transmission of data. The length of this pause is controlled by the value of the Pause Duration parameter.
Send Pause

Skip Ahead Use the following bar codes to skip ahead characters.
Skip Ahead 1 Character
Skip Ahead 2 Characters
Skip Ahead 3 Characters
Skip Ahead 4 Characters
Skip Ahead 5 Characters
Skip Ahead 7 Characters
Skip Ahead 8 Characters

Advanced Data Formatting 15-33
Skip Ahead 9 Characters

Skip Ahead 10 Characters
Skip Ahead 6 Characters
Skip Back Use the following bar codes to skip back characters.
Skip Back 1 Character
Skip Back 2 Characters
Skip Back 3 Characters

Skip Back 4 Characters
Skip Back 5 Characters
Skip Back 6 Characters
Skip Back 7 Characters
Skip Back 8 Characters
Skip Back 9 Characters

Skip Back 10 Characters

Advanced Data Formatting 15-35
Send Preset Value Use these bar codes to send preset values. These values must be set using the Scan Prefix and Scan Suffix bar codes on page 14-6.
Send Prefix · Send Suffix

Modify Data Modify data in the ways listed. The following actions work for all send commands that follow it within a rule. Programming pad zeros to length 6, send next 3 characters, stop padding, send next 5 characters, adds three zeros to the first send, and the next send is unaffected by the padding. These options do not apply to the Send Keystroke or Send Preset Value options.
Remove All Spaces To remove all spaces in the send commands that follow, scan this bar code.
Crunch All Spaces To leave one space between words, scan this bar code. This also removes all leading and trailing spaces.
Stop Space Removal Scan this bar code to disable space removal.
Remove Leading Zeros Scan this bar code to remove all leading zeros.
Stop Zero Removal Scan this bar code to disable the removal of zeros.





Advanced Data Formatting 15-41

Pad Spaces To Length 29

Pad Spaces To Length 30
Pad Data with Zeros To pad data to the left, scan the bar code containing the desired number of zeros. This parameter is activated by Send commands.
Pad Zeros To Length 1
Pad Zeros To Length 2
Pad Zeros To Length 3
Stop Pad Spaces





Beeps Select a beep sequence for each ADF rule.
Control Characters Scan the “Send __” bar code for the keystroke to send

Advanced Data Formatting 15-47








Advanced Data Formatting 15-49






Advanced Data Formatting 15-51


Keyboard Characters Scan the “Send __” bar code for the keyboard characters to send.



Advanced Data Formatting 15-53




Send .



Advanced Data Formatting 15-55

Send :







Advanced Data Formatting 15-57








Advanced Data Formatting 15-59








Advanced Data Formatting 15-61








Advanced Data Formatting 15-63







Advanced Data Formatting 15-65






Advanced Data Formatting 15-67






Advanced Data Formatting 15-69









Send Keypad .





Send Page Up Key

Advanced Data Formatting 15-73
Send Page Down Key
Send Scroll Lock Key

Send Print Screen Key






Send Up Arrow Key
Send Down Arrow Key
Send Left Arrow Key
Send Right Arrow Key
Send Home Key · Send Enter Key · Send Escape Key

Advanced Data Formatting 15-75







Advanced Data Formatting 15-77



Advanced Data Formatting 15-79








Advanced Data Formatting 15-81






Send Right Control Key The “Send Right Control Key” action will send a tap (press and release) of the Right Control Key.
Send Right Control Key

Advanced Data Formatting 15-83
Send Graphic User Interface (GUI) Characters The “Send Graphic User Interface Character” actions will tap the specified key while holding the System Dependent Graphic User Interface (GUI) Key. The definition of the Graphic User Interface key is dependant upon the attached system:




Advanced Data Formatting 15-85




Advanced Data Formatting 15-87


Turn On/Off Rule Sets Use these bar codes to turn rule sets on and off.
Turn On Rule Set 1
Turn On Rule Set 2
Turn On Rule Set 3
Turn On Rule Set 4
Send GUI Y · Send GUI Z

Advanced Data Formatting 15-89
Turn On/Off Rule Sets (continued) Use these bar codes to turn rule sets on and off.
Turn Off Rule Set 1
Turn Off Rule Set 2
Turn Off Rule Set 3
Turn Off Rule Set 4


Advanced Data Formatting 15-91

:

Advanced Data Formatting 15-93

Numeric bar codes below should not be confused with those on the numeric keypad.

Advanced Data Formatting 15-95
B

E
F
G
H
J

Advanced Data Formatting 15-97
M
N
O
P
Q

S
T
U
W

Advanced Data Formatting 15-99
Z


Advanced Data Formatting 15-101


Advanced Data Formatting 15-103




DS 3408 Product Reference Guide A-2

Standard Default Parameters A-3
Set Default Parameter All Defaults 4-5
Parameter Scanning ECh Enable 4-5
Beeper Tone 91h Medium 4-6
Beeper Volume 8Ch High 4-7
Power Mode 80h Continuous On 4-7
Time Delay to Low Power Mode 92h 5 Minutes 4-8
Trigger Mode 8Ah Level 4-9
Decode Session Timeout 88h 9.9 Sec 4-10
Timeout Between Decodes, Same Symbol 89h 0.6 Sec 4-10
Beep After Good Decode 38h Enable 4-11
Scanstand Session Timeout F0h 90h 2 Seconds 4-11
Focus Mode F0h A6h Far Focus 5-5
Decoding Illumination F0h 2Ah Enable 5-6
Decode Aiming Pattern F0h 32h Enable 5-6
Keyboard Wedge Host Parameters
Keyboard Wedge Host Type IBM PC/AT& IBM PC Compatibles1 6-5
Country Types (Country Codes) North American 6-6
Ignore Unknown Characters Transmit 6-8
Keystroke Delay No Delay 6-8
Intra-Keystroke Delay Disable 6-9
Alternate Numeric Keypad Emulation Disable 6-9
Caps Lock On Disable 6-10
Caps Lock Override Disable 6-10
1User selection is required to configure this interface and this is the most common selection.

DS 3408 Product Reference Guide A-4
Convert Wedge Data No Convert 6-11
Function Key Mapping Disable 6-11
FN1 Substitution Disable 6-12
Send and Make Break Send 6-12
RS-232 Host Types Standard1 7-8
Baud Rate 9600 7-10
Parity Type None 7-11
Stop Bit Select 1 Stop Bit 7-12
Data Bits 8-Bit 7-12
Check Receive Errors Enable 7-13
Hardware Handshaking None 7-15
Software Handshaking None 7-16
Host Serial Response Time-out 2 Sec 7-17
RTS Line State Low RTS 7-18
Beep on Disable 7-18
Intercharacter Delay 0 msec 7-19
Nixdorf Beep/LED Options Normal Operation 7-20
Ignore Unknown Characters Send Bar Code 7-20
USB Device Type HID Keyboard Emulation 8-5
USB Country Keyboard Types (Country Codes) North American 8-6
USB Keystroke Delay No Delay 8-8
USB CAPS Lock Override Disable 8-8
USB Ignore Unknown Characters Enable 8-9
Emulate Keypad Disable 8-9
USB Keyboard FN1 Substitution Disable 8-10
1User selection is required to configure this interface and this is the most common selection.

Standard Default Parameters A-5
Function Key Mapping Disable 8-10
Simulated Caps Lock Disable 8-11
Convert Case No Case Conversion 8-11
IBM 468X/469X Host Parameters
Port Address None Selected 9-5
Convert Unknown to Code 39 Disable 9-6
Wand Emulation Host Parameters
Wand Emulation Host Types Symbol OmniLink Interface Controller1 10-5
Leading Margin 80 msec 10-6
Polarity Bar High/Margin Low 10-7
Ignore Unknown Characters Ignore 10-7
Convert All Bar Codes to Code 39 Disable 10-8
Convert Code 39 to Full ASCII Disable 10-9
Beep Style Beep on Successful Transmit 11-6
Parameter Pass-Through Parameter Process and Pass Through 11-7
Convert Newer Code Types Convert Newer Code Types 11-7
Module Width 20 µs 11-8
Convert All Bar Codes to Code 39 Do Not Convert to Code 39 11-8
Code 39 Full ASCII Conversion Disable 11-9
Transmission Timeout 3 seconds 11-9
Ignore Unknown Characters Ignore Unknown Characters 11-10
Leading Margin 2 ms 11-11
Check for Decode LED Check for Decode LED 11-12
123Scan Configuration None1 12-3
1User selection is required to configure this interface and this is the most common selection.

DS 3408 Product Reference Guide A-6
UPC-A 01h Enable 13-10
UPC-E 02h Enable 13-10
UPC-E1 0Ch Disable 13-11
EAN-8/JAN 8 04h Enable 13-11
EAN-13/JAN 13 03h Enable 13-12
Bookland EAN 53h Disable 13-12
Decode UPC/EAN/JAN Supplementals (2 and 5 digits) 10h Ignore 13-13
UPC/EAN/JAN Supplemental Redundancy 50h 10 13-14
Transmit UPC-A Check Digit 28h Enable 13-15
Transmit UPC-E Check Digit 29h Enable 13-15
Transmit UPC-E1 Check Digit 2Ah Enable 13-16
UPC-A Preamble 22h System Character 13-16
UPC-E Preamble 23h System Character 13-17
UPC-E1 Preamble 24h System Character 13-18
Convert UPC-E to A 25h Disable 13-18
Convert UPC-E1 to A 26h Disable 13-19
EAN-8/JAN-8 Extend 27h Disable 13-19
UCC Coupon Extended Code 55h Disable 13-20
Code 128 08h Enable 13-20
UCC/EAN-128 0Eh Enable 13-21
ISBT 128 54h Enable 13-21
Code 39 00h Enable 13-22
Trioptic Code 39 0Dh Disable 13-22
Convert Code 39 to Code 32 (Italian Pharmacy Code) 56h Disable 13-23
1User selection is required to configure this interface and this is the most common selection.

Standard Default Parameters A-7
Code 32 Prefix E7h Disable 13-23
Set Length(s) for Code 39 12h 13h 2 to 55 13-24
Code 39 Check Digit Verification 30h Disable 13-25
Transmit Code 39 Check Digit 2Bh Disable 13-26
Code 39 Full ASCII Conversion 11h Disable 13-26
Buffer Code 39 71h Disable 13-27
Code 93 09h Disable 13-29
Set Length(s) for Code 93 1Ah 1Bh 4 to 55 13-30
Code 11 0Ah Disable 13-31
Set Lengths for Code 11 1Ch 1Dh 4 to 55 13-32
Code 11 Check Digit Verification 34h Disable 13-33
Transmit Code 11 Check Digit(s) 2Fh Disable 13-34
Interleaved 2 of 5 (ITF)
Interleaved 2 of 5 (ITF) 06h Enable 13-34
Set Lengths for I 2 of 5 16h 17h 14 13-35
I 2 of 5 Check Digit Verification 31h Disable 13-36
Transmit I 2 of 5 Check Digit 2Ch Disable 13-37
Convert I 2 of 5 to EAN 13 52h Disable 13-37
Discrete 2 of 5 (DTF)
Discrete 2 of 5 05h Disable 13-38
Set Length(s) for D 2 of 5 14h 15h 12 13-38
Codabar (NW - 7)
Codabar 07h Disable 13-39
Set Lengths for Codabar 18h 19h 5 to 55 13-40
CLSI Editing 36h Disable 13-41
1User selection is required to configure this interface and this is the most common selection.

DS 3408 Product Reference Guide A-8
NOTIS Editing 37h Disable 13-41
MSI 0Bh Disable 13-42
Set Length(s) for MSI 1Eh 1Fh 1 to 55 13-42
MSI Check Digits 32h One 13-43
Transmit MSI Check Digit 2Eh Disable 13-44
MSI Check Digit Algorithm 33h Mod 10/Mod 10 13-44
US Postnet 59h Enable 13-45
US Planet 5Ah Enable 13-45
UK Postal 5Bh Enable 13-46
Transmit UK Postal Check Digit 60h Enable 13-46
Japan Postal F0h 22h Enable 13-47
Australian Postal F0h 23h Enable 13-47
Dutch Postal F0h 46h Enable 13-48
Transmit US Postal Check Digit 5Fh Enable 13-48
RSS (Reduced Space Symbology)
RSS 14 F0h 52h Enable 13-49
RSS Limited F0h 53h Enable 13-49
RSS Expanded F0h 54h Enable 13-50
Convert RSS to UPC/EAN F0h 8Dh Disable 13-50
Composite CC-C F0h 55h Disable 13-51
Composite CC-A/B F0h 56h Disable 13-51
Composite TLC-39 F0h 73h Disable 13-52
UPC Composite Mode F0h 58h Always Linked 13-53
Composite Beep Mode F0h 8Eh Beep As Each Code Type is Decoded 13-54
1User selection is required to configure this interface and this is the most common selection.

Standard Default Parameters A-9
UCC/EAN Code 128 Emulation Mode for UCC/EAN Composite Codes
F0h ABh Disable 13-54
PDF417 0Fh Enable 13-55
MicroPDF417 E3h Disable 13-55
Code 128 Emulation 7Bh Disable 13-56
Data Matrix F0h 24h Enable 13-57
Maxicode F0h 26h Enable 13-57
QR Code F0h 25h Enable 13-58
Redundancy Level 4Eh 1 13-59
Security Level 4Dh 0 13-61
Intercharacter Gap Size F0h 7Dh Normal 13-62
Flush Macro PDF Buffer 13-63
Abort Macro PDF Entry 13-63
Transmit Code ID Character 2Dh None 14-5
Prefix Value 63h, 69h 7013 14-6
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah 7013 14-6
Scan Data Transmission Format EBh Data as is 14-7
FN1 Substitution Values 67h, 6Dh Set 14-8
Transmit “No Read” Message 5Eh Disable 14-9
Synapse Interface F0h ACh Standard 14-10
1User selection is required to configure this interface and this is the most common selection.

DS 3408 Product Reference Guide A-10

Symbol Code Identifiers B-3 AIM Code Identifiers B-4

DS 3408 Product Reference Guide B-2

Code Character Code Type
B Code 39, Code 32
F Interleaved 2 of 5
G Discrete 2 of 5, or Discrete 2 of 5 IATA
K UCC/EAN-128
M Trioptic Code 39
T UCC Composite, TLC 39
X PDF417, Macro PDF417, Micro PDF417

DS 3408 Product Reference Guide B-4
AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character (ASCII 93) c = Code Character (see Table B-2) m = Modifier Character (see Table B-3)
Code Character Code Type
A Code 39, Code 39 Full ASCII, Code 32
C Code 128, Coupon (Code 128 portion)
E UPC/EAN, Coupon (UPC portion)
I Interleaved 2 of 5
L PDF417, Macro PDF417, Micro PDF417
S Discrete 2 of 5, IATA 2 of 5
X Bookland EAN, Trioptic Code 39, US Postnet, US Planet, UK Postal, Japan Postal, Australian Postal, Dutch Postal

The modifier character is the sum of the applicable option values based on Table B-3.
Code Type Option Value Option
0 No check character or Full ASCII processing.
1 Reader has checked one check character.
3 Reader has checked and stripped check character.
4 Reader has performed Full ASCII character conversion.
5 Reader has performed Full ASCII character conversion and checked one check character.
7 Reader has performed Full ASCII character conversion and checked and stripped check character.
Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AIMID where 7 = (3+4).
0 No option specified at this time. Always transmit 0.
0 Standard data packet, no Function code 1 in first symbol position.
1 Function code 1 in first symbol character position.
2 Function code 1 in second symbol character position.
Example: A Code (EAN) 128 bar code with Function 1 character FNC1 in the first position, AIMID is transmitted as ]C1AIMID
0 No check digit processing.
1 Reader has validated check digit.
I 2 of 5
3 Reader has validated and stripped check digit.
Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123
0 No check digit processing.
1 Reader has checked check digit.
3 Reader has stripped check digit before transmission.
0 No options specified at this time. Always transmit 0.
0 Check digits are sent.
1 No check digit is sent.
Example: An MSI bar code 4123, with a single check digit checked, is transmitted as ]M14123
0 No options specified at this time. Always transmit 0.
D 2 of 5
0 Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).
1 Two-digit supplement data only.
2 Five-digit supplement data only.
4 EAN-8 data packet.

DS 3408 Product Reference Guide B-6
Code Type Option Value Option
0 No options specified at this time. Always transmit 0.
0 Single check digit
1 Two check digits
3 Check characters validated but not transmitted.
No option specified at this time. Always transmit 0. RSS-14 and RSS-Limited transmit with an Application Identifier “01”. Note: In UCC/EAN-128 emulation mode, RSS is transmitted using Code 128 rules (i.e., ]C1).
Example: An RSS-14 bar code 100123456788902 is transmitted as ]e001100123456788902.
Native mode transmission. Note: UPC portion of composite is transmitted using UPC rules.
0 Standard data packet.
1 Data packet containing the data following an encoded symbol separator character.
EAN.UCC Composites (RSS, UCC/EAN-128, 2D portion of UPC composite)
2 Data packet containing the data following an escape mechanism character. The data packet does not support the ECI protocol.
3 Data packet containing the data following an escape mechanism character. The data packet supports the ECI protocol.
UCC/EAN-128 emulation Note: UPC portion of composite is transmitted using UPC rules.
1 Data packet is a UCC/EAN-128 symbol (i.e., data is preceded with ]JC1).
0 Reader set to conform to protocol defined in 1994 PDF417 symbology specifications. Note: When this option is transmitted, the receiver cannot reliably determine whether ECIs have been invoked or whether data byte 92DEC has been doubled in transmission.
1 Reader set to follow the ECI protocol (Extended Channel Interpretation). All data characters 92DEC are doubled.
2 Reader set for Basic Channel operation (no escape character transmission protocol). Data characters 92DEC are not doubled. Note: When decoders are set to this mode, unbuffered Macro symbols and symbols requiring the decoder to convey ECI escape sequences cannot be transmitted.
3 The bar code contains a UCC/EAN-128 symbol, and the first codeword is 903-907, 912, 914, 915.
4 The bar code contains a UCC/EAN-128 symbol, and the first codeword is in the range 908-909.
5 The bar code contains a UCC/EAN-128 symbol, and the first codeword is in the range 910-911.
Example: A PDF417 bar code ABCD, with no transmission protocol enabled, is transmitted as ]L2ABCD.
0 ECC 000-140, not supported.
1 ECC 200.
2 ECC 200, FNC1 in first or fifth position.
3 ECC 200, FNC1 in second or sixth position.
4 ECC 200, ECI protocol implemented.
5 ECC 200, FNC1 in first or fifth position, ECI protocol implemented.
6 ECC 200, FNC1 in second or sixth position, ECI protocol implemented.

Code Type Option Value Option
0 Symbol in Mode 4 or 5.
1 Symbol in Mode 2 or 3.
2 Symbol in Mode 4 or 5, ECI protocol implemented.
3 Symbol in Mode 2 or 3, ECI protocol implemented in secondary message.
0 Model 1 symbol.
1 Model 2 symbol, ECI protocol not implemented.
2 Model 2 symbol, ECI protocol implemented.
3 Model 2 symbol, ECI protocol not implemented, FNC1 implied in first position.
4 Model 2 symbol, ECI protocol implemented, FNC1 implied in first position.
5 Model 2 symbol, ECI protocol not implemented, FNC1 implied in second position.
6 Model 2 symbol, ECI protocol implemented, FNC1 implied in second position.
Programming Reference B-7 · MaxiCode · QR Code

DS 3408 Product Reference Guide B-8

Code 39 C-3 UPC/EAN C-3
UPC-A, 100 % C-3 EAN-13, 100 % C-3 Code 128 C-3 Interleaved 2 of 5 C-4 RSS 14 C-4 PDF417 C-4 Data Matrix C-4 Maxicode C-5 QR Code C-5 US Postnet C-5 UK Postal C-5

DS 3408 Product Reference Guide C-2

Sample Bar Codes C-3

1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4

DS 3408 Product Reference Guide C-4

RSS 14 must be enabled to read the bar code below (see RSS-14 on page 13-49).

Sample Bar Codes C-5


DS 3408 Product Reference Guide C-6

Numeric Bar Codes D-3 Cancel D-4

DS 3408 Product Reference Guide D-2

Numeric Bar Codes D-3
Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).

DS 3408 Product Reference Guide D-4
Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
Cancel To correct an error or change a selection, scan the bar code below.
Cancel


DS 3408 Product Reference Guide E-2

ASCII Character Sets E-3
Full ASCII Code 39
1001 $A CTRL A
1002 $B CTRL B
1003 $C CTRL C
1004 $D CTRL D
1005 $E CTRL E
1006 $F CTRL F
1007 $G CTRL G
1008 $H CTRL H/ BACKSPACE 1
1009 $I CTRL I/ HORIZONTAL TAB 1
1010 $J CTRL J
1011 $K CTRL K
1012 $L CTRL L
1013 $M CTRL M/ ENTER 1
1014 $N CTRL N
1015 $O CTRL O
1016 $P CTRL P
1017 $Q CTRL Q
1018 $R CTRL R
1019 $S CTRL S
1020 $T CTRL T
1021 $U CTRL U
1022 $V CTRL V
1023 $W CTRL W
1024 $X CTRL X
The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.
ASCII Value · Encode Char Keystroke

DS 3408 Product Reference Guide E-4
Full ASCII Code 39
1026 $Z CTRL Z
1027 %A CTRL [
1028 %B CTRL \
1029 %C CTRL ]
1030 %D CTRL 6
1031 %E CTRL -
1033 /A !
1034 /B “
1035 /C #
1036 /D $
1037 /E %
1038 /F &
1039 /G ‘
1040 /H (
1041 /I )
1042 /J *
1043 /K +
1044 /L ,
1046 . .
The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.

ASCII Character Sets E-5
Full ASCII Code 39
1059 %F ;
1060 %G <
1061 %H =
1062 %I >
1063 %J ?
1064 %V @
1065 A A
1066 B B
1067 C C
1068 D D
1069 E E
1070 F F
1071 G G
1072 H H
1073 I I
1074 J J
1075 K K
1076 L L
1077 M M
1078 N N
The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.

DS 3408 Product Reference Guide E-6
Full ASCII Code 39
1080 P P
1081 Q Q
1082 R R
1083 S S
1084 T T
1085 U U
1086 V V
1087 W W
1088 X X
1089 Y Y
1090 Z Z
1091 %K [
1092 %L \
1093 %M ]
1094 %N ^
1095 %O _
1096 %W ‘
The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.

ASCII Character Sets E-7
Full ASCII Code 39
1124 %Q I
1125 %R }
1126 %S ~
The keystroke in bold is sent only if the Function Key Mapping is enabled. Otherwise, the unbold keystroke is sent.

DS 3408 Product Reference Guide E-8
2065 ALT A
2066 ALT B
2067 ALT C
2068 ALT D
2069 ALT E
2070 ALT F
2071 ALT G
2072 ALT H
2073 ALT I
2074 ALT J
2075 ALT K
2076 ALT L
2077 ALT M
2078 ALT N
2079 ALT O
2080 ALT P
2081 ALT Q
2082 ALT R
2083 ALT S
2084 ALT T
2085 ALT U
2086 ALT V
2087 ALT W
2088 ALT X
2089 ALT Y
2090 ALT Z
ALT Keys Keystroke

ASCII Character Sets E-9
3000 Right Control Key
3049 GUI 1
3050 GUI 2
3051 GUI 3
3052 GUI 4
3053 GUI 5
3054 GUI 6
3055 GUI 7
3056 GUI 8
3057 GUI 9
3065 GUI A
3066 GUI B
3067 GUI C
3068 GUI D
3069 GUI E
3070 GUI F
3071 GUI G
3072 GUI H
3073 GUI I
3074 GUI J
3075 GUI K
3076 GUI L
3077 GUI M
3078 GUI N
3079 GUI O
3080 GUI P
3081 GUI Q
3082 GUI R
3083 GUI S
3084 GUI T
3085 GUI U
3086 GUI V
GUI Key Keystroke

DS 3408 Product Reference Guide E-10
3088 GUI X
3089 GUI Y
3090 GUI Z
4002 PF 2
4003 PF 3
4004 PF 4
4005 PF 5
4006 PF 6
4007 PF 7
4008 PF 8
4009 PF 9
4010 PF 10
4011 PF 11
4012 PF 12
4013 PF 13
4014 PF 14
4015 PF 15
4016 PF 16
GUI Key Keystroke · PF Keys Keystroke

ASCII Character Sets E-11
5002 F 2
5003 F 3
5004 F 4
5005 F 5
5006 F 6
5007 F 7
5008 F 8
5009 F 9
5010 F 10
5011 F 11
5012 F 12
5013 F 13
5014 F 14
5015 F 15
5016 F 16
5017 F 17
5018 F 18
5019 F 19
5020 F 20
5021 F 21
5022 F 22
5023 F 23
5024 F 24
Table E-6. Numeric Key Standard Default Table

DS 3408 Product Reference Guide E-12
Table E-7. Extended Keypad Standard Default Table

AIM Automatic Identification Manufacturers, Inc. is the trade association for manufacturers of automatic identification systems.
Alphanumeric A character set that contains letters, numbers and other characters such as special symbols.
Aperture The opening in an optical system defined by a lens or baffle that establishes the field of view.
ASCII American Standard Code for Information Interchange. A 7-bit-plus-parity code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the U.S.
Aspect Ratio The ratio of symbol height to symbol length in a 2-dimensional symbol.
Autodiscrimination The ability of an interface controller to determine the code type of a scanned bar code. After this determination is made, the information content is decoded.
Automatic Identification System The application of various technologies, such as bar code recognition, image recognition, voice recognition and RF/MW transponders, for the purpose of data entry into a data processing system and bypassing the key-entry component of traditional data entry.
Background The area surrounding a printed symbol including the spaces and quiet zones.
Bar The dark element in a printed bar code symbol.
Bar Code An array of parallel rectangular bars and spaces arranged according to the encodation rules of a particular symbol specification in order to represent data in machine-readable form (i.e., Code 39).
Bar Code Character A single group of bars and spaces which represent an individual number, letter, punctuation mark or other symbol.

DS 3408 Product Reference Guide GL-2
Bar Code Density The number of characters represented per unit of measurement (e.g., characters per inch).
Bar Code Reader A device used to read or decode a bar code symbol.
Bar Code Symbol The combination of symbol characters and features required by a particular symbology, including quiet zones, start and stop characters, data characters, check characters and other auxiliary patterns, that together form a complete scannable entity (see symbol).
Bar Height The dimension of a bar measured perpendicular to the bar width. or The dimension of the individual bars in a bar code symbol or in a row of a multi- row, 2-dimensional symbol that is measured perpendicular to the scanning direction (see Y dimension).
Bar Width Thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar. or The transverse dimension of an individual bar in a bar code symbol that is measured parallel to the scanning direction. The number of possible width variations within a particular printed symbol depends on the symbology used (see X dimension).
Baud Rate A measure of the data flow or number of signaling events occurring per second. When one bit is the standard "event," this is a measure of bits per second (bps). For example, a baud rate of 50 means transmission of 50 bits of data per second.
Bi-directional Denotes that a machine-readable symbol can be read successfully in two directions – either backwards or forwards. Also identifies a scanner that can operate or a bar code that can be read independent of scanning direction.
Binary Denotes a numbering system to base 2 in which numbers are expressed as combinations of the digits 0 and 1 with positional weighting based on powers of 2. In computing, these can be represented electrically by 'off' and 'on' respectively or in machine-readable symbols by narrow and wide elements or by the absence or presence of a bar module.
Bit Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning.
Byte On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory is used to store one ASCII character. or A sequential series of bits comprising one character and handled as one unit. Usually encoded in the ASCII format, a byte usually consists of eight bits and represents one alphabetic or special character, two decimal digits or eight binary bits.
CDRH Center for Devices and Radiological Health. A federal agency responsible for regulating laser product safety. This agency specifies various laser operation classes based on power output during operation.
CDRH Class 1 This is the lowest power CDRH laser classification. This class is considered intrinsically safe, even if all laser output were directed into the eye's pupil. There are no special operating procedures for this class.

CDRH Class 2 No additional software mechanisms are needed to conform to this limit. Laser operation in this class poses no danger for unintentional direct human exposure.
Character A pattern of bars and spaces which either directly represents data or indicates a control function, such as a number, letter, punctuation mark, or communications control contained in a message.
Character Set Those characters available for encoding in a particular bar code symbology.
Check Digit A digit used to verify a correct symbol decode. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC but are optional for other symbologies. Using check digits decreases the chance of substitution errors when a symbol is decoded.
Codabar A discrete self-checking code with a character set consisting of digits 0 to 9 and six additional characters: ( - $ : / , +).
Code A set of unambiguous rules specifying the way in which data may be represented as numbers and letters used to represent information (see number system).
Code 128 A high density symbology which allows the controller to encode all 128 ASCII characters without adding extra symbol elements.
Code 3 of 9 (Code 39) A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9, and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow.
Code 93 An industrial symbology compatible with Code 39 but offering a full character ASCII set and a higher coding density than Code 39.
Code Length Number of data characters in a bar code between the start and stop characters, not including those characters.
Codeword As a symbol character value, this isan intermediate level of coding between source data and the graphical encodation in the symbol.
Concatination The construction of a string of data from two or more strings by appending each string in succession. The linking or chaining together of separate items of data in a bar code symbol or of the data contained in two or more separate bar code symbols (also referred to as message append and structured append).
Continuous Code A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code. The absence of gaps allows for greater information density.
Contrast The difference in reflectance between the black and white (or bar and space) areas of a symbol.
Data Identifier A specified character or string of characters that defines the intended use of the data element that follows. For the purposes of automatic data capture technologies, data identifier refers to the alphanumeric identifiers as defined in ANSI MH10.8.2, formerly known as ANSI/FACT data identifiers.

DS 3408 Product Reference Guide GL-4
Data Matrix This error correcting, 2-dimensional matrix symbology was originally developed in 1989, and a finalized design was completed in 1995 by International Data Matrix. It's capable of encoding various character sets including strictly numeric data, alphanumeric data and all ISO 646 (ASCII) characters, as well as special character sets. The symbology has both error detection and error correction features. Each Data Matrix symbol consists of data regions, which contain nominally square modules set out in a regular array. A dark module is a binary 1 and a light module is a binary 0. There is no specified minimum or maximum for the X or Y dimension. The data region is surrounded by a finder pattern, a perimeter to the data region that is 1 module wide, which is surrounded by a quiet zone on all four sides of the symbol. Two adjacent sides are solid dark lines used primarily to define physical size, orientation and symbol distortion. The two opposite sides consist of alternating dark and light modules. These are used primarily to define the cell structure but also assist in determining physical size and distortion. There are 2 types of Data Matrix symbologies: ECC 000 - 140 with several available levels of convolutional error correction, and ECC 200, which uses Reed-Solomon error correction. For ISO/ IEC JTC 1/SC 31 purposes, only ECC 200 is recommended. The intellectual property rights associated with Data Matrix have been committed to the public domain.
Data Structure The stipulation of the type of information that is included in a bar code, such as its order and format.
Dead Zone An area within a scanner's field of view, in which specular reflection may prevent a successful decode.
Decode To recognize a bar code symbology (e.g., UPC/EAN) and then analyze the content of the specific bar code scanned.
Decode Algorithm A decoding scheme that converts pulse widths into data representation of the letters or numbers encoded within a bar code symbol.
Decoder An electronic package that receives the signals from the scanning function, performs the algorithm to interpret the signals into meaningful data and provides the interface to other devices.
Depth of Field The range between minimum and maximum distances at which a scanner can read a symbol with a certain minimum element width.
Diffuse Reflection The component of reflected light that emanates in all directions from the reflecting surface.
Discrete 2 of 5 A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded.
Discrete Code A bar code or symbol in which the spaces between characters (intercharacter gaps) are not part of the code.
EAN European Article Number. This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail.

EAN/U.P.C. A fixed-length, numeric 13-digit bar code symbol consisting of 30 dark elements and 29 intervening light elements. Each character is represented by 2 bars and 2 spaces over 7 modules. A bar may be comprised of 1, 2, 3 or 4 modules. Each EAN/U.P.C. symbol consists of a leading quiet zone, a start pattern, 7 left-hand data characters, a center bar pattern, 5 right-hand data characters, a Modulo 10 check character, a stop pattern and a trailing quiet zone. U.P.C. is often considered a 12-digit code. The 13th digit of EAN/U.P.C. symbol is a derived character in the left-most position. In the case of U.P.C., this derived left-most character is a 0.
Element Generic term for a bar or space.
Encoded Area Total linear dimension occupied by all characters of a code pattern, including start/stop characters and data.
Error Correction A reader or decoder's use of mathematical schemes to reconstruct or replace damaged or missing symbol characters to enable the reading of the symbol data.
Error Detection This occurs when error-correction characters detect that the presence of errors in the symbol exceeds the error correction capacity, and keeps the symbol from being decoded as erroneous data.
Error-Correction Characters Symbol characters used for error correction and detection, calculated automatically from the other symbol characters.
Error-Correction Level An indicator of the number of characters used in a symbology for error correction. A higher level of error correction allows for correcting greater potential symbol damage.
Error-Detection Characters Symbol characters reserved for error detection that are calculated automatically from the other symbol characters.
Fixed Beam Bar Code Reader A scanning device where scanning motion is achieved by moving the object relative to the reader; as opposed to a moving beam reader.
Guard Bars Bars located at both ends and the center of a UPC and EAN symbol to provide reference points for scanning.
Horizontal Bar Code A bar code or symbol with an overall length dimension that is parallel to the horizon, which resembles a picket fence.
Host Computer A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control.
IEC International Electrotechnical Commission. This international agency regulates laser safety by specifying various laser operation classes based on power output during operation.
IEC (825) Class 1 This is the lowest power IEC laser classification. Conformity is ensured through a software restriction of 120 seconds of laser operation within any 1000 second window and an automatic laser shutdown if the scanner's oscillating mirror fails.
Intercharacter Gap The space between two adjacent bar code characters in a discrete code.
Interleaved 2 of 5 A binary bar code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides for greater information density. The location of wide elements (bar/spaces) within each group determines which characters are encoded. This continuous code type uses no intercharacter spaces. Only numeric (0 to 9) and START/STOP characters may be encoded.
Interleaved Bar Code A bar code in which characters are paired together, using bars to represent the first character and the intervening spaces to represent the second.

DS 3408 Product Reference Guide GL-6
LASER - Light Amplification by Stimulated Emission of Radiation
The laser is an intense light source. Light from a laser is all the same frequency, unlike the output of an incandescent bulb. Laser light is typically coherent and has a high energy density.
Laser Diode A gallium-arsenide semiconductor type of laser connected to a power source to generate a laser beam. This laser type is a compact source of coherent light.
Laser Scanner An optical bar code reading device using a coherent laser light beam as its source of illumination.
LED Indicator A semiconductor diode (LED - Light Emitting Diode) used as an indicator, often in digital displays. The semiconductor uses applied voltage to produce light of a certain frequency determined by the semiconductor's particular chemical composition.
Matrix Symbols A 2-dimensional array of regular polygon shaped cells where the center-to- center distance of adjacent elements is uniform. The arrangement of the cells represents data and/or symbology functions. Matrix symbols may include recognition patterns that do not follow the same rule as the other elements within the symbol (i.e., Data Matrix and MaxiCode).
MIL 1 mil = 1 thousandth of an inch; a unit of measure often used to quantify bar code printing and scanning dimensions.
Misread (Misdecode) A condition which occurs when the data output of a reader or interface controller does not agree with the data encoded within a bar code symbol.
Module (1) The narrowest nominal width unit of measure in a symbol. In certain symbologies, element widths are specified as multiples of 1 module. Equivalent to X dimension; or (2) a single cell in a matrix symbology used to encode 1 bit of data. In MaxiCode, the module shape is a regular hexagon. In Data Matrix, the module shape is nominally square. In PDF417, the module shape is a regular rectangle. In bar code symbologies, the module shape is a regular rectangle.
Module Check Digit or Character A character within the symbol data field calculated using modular arithmetic that is used for error detection. The calculated character is determined by applying a code algorithm to the data field contents (see check character).
Moving Beam Bar Code Reader A device where scanning motion is achieved by mechanically moving the optical geometry.
MRD Minimum reflectance difference: a formula that is used to determine if there is an adequate difference between absorbed and reflected light.
Nanometer Unit of measure used to define the wavelength of light that is equal to 10-9 meter.
Nominal The exact (or ideal) intended value for a specified parameter. Tolerances are specified as positive and negative deviations from this value.
Nominal Size Standard size for a bar code symbol. Most UPC/EAN codes are used over a range of magnifications (e.g., from 0.80 to 2.00 of nominal).
Non-Contact Reader/Scanner Bar code readers requiring no physical contact with the printed symbol.
Non-read The absence of data at the scanner output after an attempted scan, which is due to no code, defective code, scanner failure or operator error.
Omnidirectional Bar codes read in any orientation relative to the scanner.
Optical Throw The distance from the scanner face to the closest point at which symbol can be read; also, optical throw is the difference between range and depth of field.

Orientation The alignment of the symbol's scan path. Two possible orientations are horizontal with vertical bars and spaces (picket fence) and vertical with horizontal bars and spaces (ladder).
Overhead The fixed number of characters required for start, stop and checking in a given symbol. For example, a symbol requiring a start, stop and 2 check characters contains 4 characters of overhead.
Parameter A variable that can have different values assigned to it.
PDF417 An error correcting 2-dimensional multi-row symbol developed in 1992 by Symbol Technologies, PDF417 symbols are constructed from 4 bars and 4 spaces over 17 modules. The symbol size is from 3 to 90 rows. There is no specified minimum or maximum for X or Y dimension. With at least the recommended minimum level of error correction, the recommended Y dimension is 3X. With less than the minimum recommended level of error correction, the recommended Y dimension is 4X. A quiet zone of 2X is specified on each side of a symbol. Because of delta decode techniques, the symbology is immune from uniform bar width growth. PDF417 supports cross-row scanning. The intellectual property rights associated with PDF417 have been committed to the public domain.
Percent Decode The average probability that a single scan of a bar code would result in a successful decode. In a well-designed bar code scanning system, that probability should approach near 100%.
Pitch Rotation of a bar code symbol in an axis parallel to the direction of the bars.
Plessey Code A pulse-width, modulated bar code commonly used for shelf marking in grocery stores.
Postnet Code Code developed by the U.S. Postal Service to assist in the automatic sorting of mail.
Print Contrast Signal (PCS) Measurement of the contrast (brightness difference) between the bars and spaces of a symbol. A minimum PCS value is needed for a bar code symbol to be scannable. PCS = (RL - RD) / RL, where RL is the reflectance factor of the background and RD the reflectance factor of the dark bars.
Programming Mode The state in which a scanner is configured for parameter values. See SCANNING MODE.
Quiet Zone A clear space, containing no dark marks, which precedes the start character of a bar code symbol and follows the stop character.
Reflectance Amount of light returned from an illuminated surface.
Resolution The narrowest element dimension which is distinguished by a particular reading device or printed with a particular device or method.
RSS Reduced Space Symbology: A family of space efficient symbologies developed by UCC.EAN.
Scan Area Area intended to contain a symbol.
Scanner An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are: 1. Light source (laser or photoelectric cell) - illuminates a bar code. 2. Photodetector - registers the difference in reflected light (more light reflected from spaces). 3. Signal conditioning circuit - transforms optical detector output into a digitized bar pattern.
Scanning Mode The scanner is energized, programmed, and ready to read a bar code.

DS 3408 Product Reference Guide GL-8
Scanning Sequence A method of programming or configuring parameters for a bar code reading system by scanning bar code menus.
Self-Checking Code A symbology that uses a checking algorithm to detect encoding errors within the characters of a bar code symbol.
Skew Rotation of a bar code symbol on an axis parallel to the symbol's length.
Space The lighter element of a bar code formed by the background between bars.
Space Width The thickness of a space measured from the edge closest to the symbol start character to the trailing edge of the same space.
Specular Reflection The mirror-like direct reflection of light from a surface, which can cause difficulty decoding a bar code.
Stacked Symbol (2D Symbols) A 2-dimensional (2D) symbol with sequences of linear (width-coded) data that are stacked one upon another (i.e., PDF417).
Start/Stop Character A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are normally to the left and right margins of a horizontal code.
Substrate A foundation material on which a substance or image is placed.
Symbol A scannable unit that encodes data within the conventions of a certain symbology, usually including start/stop characters, quiet zones, data characters, and check characters.
Symbol Aspect Ratio The ratio of symbol height to symbol width.
Symbol Density The number of data characters per unit length; usually expressed as characters per inch (CPI).
Symbol Height The distance between the outside edges of the quiet zones of the first row and the last row.
Symbol Length Length of symbol measured from the beginning of the quiet zone (margin) adjacent to the start character to the end of the quiet zone (margin) adjacent to a stop character.
Symbology The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39).
Tilt Rotation of a bar code symbol on an axis perpendicular to the substrate.
Tolerance Allowable deviation from the nominal bar or space width.
Two-dimensional symbology A machine-readable symbol which must be examined both vertically and horizontally to read the entire message. A 2-dimensional (2D) symbol may be one of two types of machine-readable symbols: a Matrix Symbol or a stacked symbol. 2D symbols differ from linear bar codes with the ability for high data content, small size, data efficiency and error correction capability.
UCC Uniform Code Council: the organization that administers the U.P.C and other retail standards.
UCC.EAN-128 Code 128 with a Function 1 character in the first position that is the symbology used with the UCC.EAN format for a universal product number (UPN).
UPC Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which is any of four widths. The standard symbology for retail food packages in the United States.
Variable Length Code A code with a number of encoded characters within a range, as opposed to a code with a fixed number of encoded characters.

Vertical Bar Code A bar code pattern presented in such orientation that the symbol from start to stop is perpendicular to the horizon. The individual bars are in an array appearing as rungs of a ladder.
Visible Laser Diode (VLD) A solid state device which produces visible laser light.
Wand Scanner A handheld scanning device used as a contact bar code or OCR reader.
Wedge A device that plugs in between a keyboard and a terminal and allows data to be entered by a keyboard or by various types of scanners.
X Dimension The dimension of the narrowest bar and narrowest space in a bar code.
Y Dimension The height of the modules in a row of a 2-dimensional (2D) symbols.

DS 3408 Product Reference Guide GL-10

Tell Us What You Think...
We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 738-3318, or mail to:
Symbol Technologies, Inc. One Symbol Plaza M/S B-4 Holtsville, NY 11742-1300 Attention: Technical Publications Manager
How familiar were you with this product before using this manual?
Very familiar Slightly familiar Not at all familiar
Did this manual meet your needs? If not, please explain
What topics need to be added to the index, if applicable?
What topics do you feel need to be better discussed? Please be specific
What can we do to further improve our manuals?
Thank you for your input—We value your comments.






Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.