TDS 500D, TDS 600C & TDS 700D Digitizing Oscilloscopes
071-0273-02
This document supports firmware version 5.1 and above.

Copyright Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A.
Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.

Most TDS 600B information in the TDS 500D, TDS 600B, & TDS 700D Digitizing Oscilloscopes User manual is valid for the TDS 654C, TDS 680C, and TDS 684C oscilloscope models. This supplement lists the differences between the TDS 600C and the TDS 600B models.
Except for the differences outlined in this manual, the TDS 600C is identical to a TDS 600B. Most of the information in your user manual (and other TDS documentation) that applies to the TDS 600B also applies to the TDS 600C.
Table 1 lists the key features of the oscilloscope models. The pages that follow list the new TDS 600C features.


Feature 794D 784D 754D 724D 684C 680C 654C 580D 540D 520D
Floppy Disk Hard Disk Zip Drive Support
I/0 includes RS–232 and Centronics5
Option 13 Standard4
Input Impedance 50 and 1 M 50 only
Measurement statistics (mean, min, max, and std dev
Display Mono Color Mono Color
1 Two plus Two channel operation allows two of four channels to be displayed simultaneously. Channels not displayed can be used to couple a triggering signal to the oscilloscope.
2 These TDS models can be purchased with Option 1M or Option 2M, which add longer record length settings (up to 2 Mb/channel). See Option 1M and Option 2M on pages 4 and 5.
3 Advanced digital signal processing provides FFTs, integrals, and derivatives of waveforms. See Option 2F on page 5.
4 Standard denotes a standard product feature as opposed to a feature included as part of an option.
5 GPIB I/O included with all models.
The TDS 600C can display histograms as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can select and load Java-based applications in the APPLICA- TION menu as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual. Then you can control the application using the APPLICATION menus.

If your TDS 600C contains the optional hard disk, you can use it to save and recall waveforms, setups, and hard copies as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual. With this option, you can also run Java-based application programs.
Iomega Zip Drive Support
The TDS 600C is compatible with Iomega 100 Mbyte Zip drives as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can display statistics about a measurement as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
Take Optical Measurements
The TDS 600C can take Extinction Ratio, Extinction Percent, Extinction dB, and Mean dBm measurements as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
The TDS 600C can set External Attenuation as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.
On the TDS 600C, use the TDS 500D and TDS 700D procedures to calibrate a probe as described in the TDS 500D, TDS 600B & TDS 700D Digitizing Oscilloscopes User Manual.

Tektronix will ship the options shown in Table 2:
Option # Label Description
A1 Universal European power cord
220 V, 50 Hz power cord
A2 UK power cord 240 V, 50 Hz power cord
A3 Australian power cord 240 V, 50 Hz power cord
A4 North American power cord
240 V, 60 Hz power cord
A5 Switzerland power cord 220 V, 50 Hz power cord
HD Hard disk drive Add a hard disk.
05 Video trigger Oscilloscope comes with tools for investigating events that occur when a video signal generates a horizontal or vertical sync pulse. These tools allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals. (Option is not available on the TDS 794D.)
13 RS-232/Centronics Hard- copy Interface Ports
Add RS-232-C and Centronics interface ports. (Option applies to TDS 500D only.)
1G 1 GS/s maximum Limit sample rate to 1 GS/s maximum. (Option applies to TDS 520D, TDS 540D, TDS 724D, and TDS 754D only.)
1K Scope cart K420 scope cart. This cart can help transport the oscilloscope around many lab environ- ments.
1M 130,000 record length Extend record length from 50,000 samples standard as follows:
TDS 540D, TDS 580D, TDS 754D, TDS 784D, and TDS 794D: To 500,000 samples on one channel, 250,000 on two channels, and 130,000 samples on three or four channels
(Option is only available for the models listed above.)

Option # Description Label
2M 8 M acquisition length Extend standard acquisition length as follows:
TDS 540D, TDS 580D, TDS 754D, TDS 784D, & TDS 794D: To 2 M samples on three or four channels, 4 M on two channels, and 8 M samples on one channel
(Option includes a hard disk and is only available for the models listed above.)
1R Rackmount Oscilloscope comes configured for installation in a 19 inch wide instrument rack. For later field conversions, order kit # 016-1236-00.
2C Communication Signal Analyzer
Oscilloscope comes configured for communications signal triggering and mask testing. (Option applies to TDS 500D & TDS 700D only.)
3C P6701B with system calibration
Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
4C P6703B with system calibration
Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference receiver on channel 1. (Option applies to TDS 500D & TDS 700D only, except TDS 794D.)
31 Buffered passive probe Add a 500 MHz P6339A 10x, buffered passive probe (Option applies only to TDS 794D.)
32 Active probe Add a 4 GHz P6217 active probe (Option applies only to TDS 794D.)
33 Low capacitance probe Add a 3.0 GHz (probe only) P6158 20x, 1 k, low capacitance probe (Option applies only to TDS 580D, TDS 680C, TDS 684C, TDS 784D, and TDS 794D.)
34 Differential probe Add a 1 GHz (probe only) P6247 differential probe
35 Active probe Add a 1 GHz (probe only) P6243 active probe (Option applies only to TDS 754D, TDS 724D, TDS 540D, and TDS 520D.)
36 Passive probe Add a 500 MHz P6139A 10X passive probe (Option applies only to TDS 784D, TDS 600C, and TDS 580D.)
37 Active probe Add a 1.5 GHz P6245 active probe (Option applies only to TDS 794D, TDS 784D, TDS 680C, TDS 684C, and TDS 580D.)
2F Advanced DSP math Add advanced DSP math features such as FFT, integration, and differentiation. (Option applies only to TDS 500D models.)

Option # Description Label
C3 Three years calibration Provides three years of calibration
C5 Five years calibration Provides five years of calibration
D1 Calibration data report Oscilloscope comes with a calibration data report.
D3 Calibration data for C3 Provides calibration data for option C3
D5 Calibration data for C5 Provides calibration data for option C5
R5 Extended Warranty Oscilloscope comes with a 5 year extended warranty.
Provides Language versions of User Manual, according to option number chosen.
The oscilloscope comes standard with the accessories listed in Table 3.

You can also order the optional accessories listed in Table 4.
Rack Mount Kit (for field conversion) 016-1236-00
Accessory Pouch (TDS 500D and TDS 680C) 016-1268-00
Soft-Sided Carrying Case 016-0909-01
GPIB Cable (1 meter) 012-0991-01
GPIB Cable (2 meter) 012-0991-00

Table 5 lists the recommended probes for each oscilloscope.
Table 5: Recommended probe cross reference


Oscilloscopes numériques TDS 500D, TDS 600C & TDS 700D
071-0273-02
Le présent document s’applique aux versions ma- térielles 5.1 et ultérieures.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.