Gebruiksaanwijzing /service van het product TED 191 van de fabrikant Teledyne
Ga naar pagina of 30
i TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments TED ' P ORT ABLE O XYGEN M ONIT OR I NSTRUCTION M ANUAL TYPE B EQUIPMENT: Equipment providing a particular degree of protec- tion against electric shock, particularly regarding— • allowable LEAKAGE CURRENT • Reliability of the protective earth connection (if present).
2 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments C OPYRIGHT © 1996 T ELEDYNE E LECTRONIC TECHNOLOGIES – A NAL YTICA L I NSTRUM ENTS A ll Rights Reserved No par t of this m anual may be re.
3 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T AB L E O F C ONTENTS S ECTION T OPIC P AG E N UMBER I NTRODUCTION 4 A PPLICA TION S 5 D ESCRI PTIONS O F F UNCTIONAL Z ONES : F RONT P ANEL 6 R EAR P AN EL 7 1. O PER ATION S : 1.1 S ET - UP 8 1.
4 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments I NTRODUCTION The T ED 191 Portab le Ox ygen Monitor is a n eas y-to-use , port able instrum ent that pro vides f ast and accurate ox ygen m onitoring and aud io-vis ual alarm capabi lity.
5 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments A PPLICA TIONS The ins trum ent is desi gned f or the m easur em ent of ox ygen conc entra tions in a variet y of m edical gas m ixtures .
6 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments 21 30 40 50 60 70 80 90 102 21 30 40 50 60 70 80 90 102 LO HI X 21 TELEDYNE % OXYGEN OXYGEN M ONIT OR I O D ES CRIPT ION OF F UNCTIONAL Z ONES F RONT P AN E L On / Of f Sw itch Allows th e operat or to t urn the i nstrum ent on a nd of f.
7 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments D ES CRIPT ION OF F UNCTIONAL Z ONES R EA R P ANE L Battery Drawer The Batter y Drawer cont ains 4 x AA (P enlight) batteri es required to power the ins trum ent. Sensor Cable Connector Plug The Oxygen Sensor Con nector C able is plugg ed into this “one way” sock et.
8 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION O NE O PERATIONS Note : Upon receip t, inspect the entir e unit and ac com panying acc essor ies for dam age or brok en or loose parts. If dam aged, do not use. Notif y t he Shippe r, a nd c onsult Tele dyne Electro nic T echno logies Anal ytical Inst ruments 1.
9 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.2 I NSTA LL ING TH E BA TTERIE S W ithdraw the battery drawer fr om the monitor casing, by grasp ing the s ide lugs loca ted on either s ide of the batter y dra wer, and , firm ly pinch ing them inwards , s im ultaneousl y pu ll th e drawer o utwards.
10 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.3 I NSTALLING THE O XYGEN SENSOR The T- 7 Ox ygen Sensor m ust be insta lled bef ore the instrum ent c an be use d. Ensure t hat the m onit or is s witched off . Remove the s ens or fr om its pr otective bag.
11 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.4 C AL IBRA TE THE I NSTRUMENT Calibration shou ld be ef fec ted at le ast once per sh ift, and alwa ys prior t o the use of the instrum ent. Note: Never expos e the se nsor to v aryi ng temp eratures w hile c alibr ating ( i.
12 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.5 N ORM AL O PERATION Switch the instrum ent o n usi ng the On –Of f Switch . Validate the ca librat ion of the instrum ent by ex posing t he ox ygen sensor to room air , and verif ying that the displa y on the instrum ent reads 100% (± 2 %).
13 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.6 S ET THE A LA RMS The lines in dicating the 100% gradua tions ar ound t he Hig h and L ow Al arm Settings Knobs are onl y intended as gu ides, an d not as prec ise sett ings.
14 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T WO A NAESTHETIC A GENTS 2. A N AESTHETIC A GENTS The anaes thetic agents listed in the f ollow ing ta ble (Halo thane, Enf lur ane, Is oflur ane Sev ofl urane, and Desflur ane) were vap orised int o a stream of 30%ox ygen / 70% n itrous oxide.
15 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T HREE C LEA NING A ND S TERI L IS ATION 3.1 C LEANING T HE TED 191 P ORTABLE O XYGEN M ONIT OR The instrum ent itself shou ld be cl eaned using a d am p cloth.
16 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION F OU R D O ’ S A ND D ON ’ TS D O ’ S ; Read the O perator s Manual thor oughl y before us ing the instr um ent. ; Calibrate onc e per s hif t, and prior to e ach and e ver y use.
17 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION F IV E R OU TIN E M A INTE NA NCE 5.1 R OUTIN E V ISU AL I NSPECTION Always ins pect t he instr um ent prior to us e f or obvio us dam age or f or parts or com ponents miss ing.
18 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION S IX T RO UBLESHOOTING S YMP TOM C URE / R EM ARK No numer ic disp la y on the LCD when powered on 1) Check batter y drawer is proper ly locate d.
19 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ROUBLESHOOTING S YMP TOM C URE / R EM ARK The dis played rea dings are unsta ble 1) Rem ove the sens or tip f rom the T-adaptor , unsc rew th e “flo w diverter” and g entl y swab an y exces s m oisture of f the s ensor c ell mem brane, then f low dr y gas over th e m embrane.
20 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION S EVEN T ECHNICAL S PE CIFICA TIONS SA FE TY CLASSI FICATION Complies to IEC 601 – Safety of Medical Eq uipm ent Internall y pow.
21 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ECHNIC AL S PE CIFIC ATION S SENSO R RES PON SE TI ME Less than 6 secon ds to 90% of f inal m easured v alue in r espons e to a step ch ange in th e actu al ox ygen co ncentrat ion be ing m easured.
22 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION E IGHT E FFECT OF P RESSURE Virtual ly all gas sens ors and anal ysers m eas ure the part ial pr essure, no t the per cent age, of the gas that they sens e.
23 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION N IN E E FFECT OF H UMID ITY Humidit y does not directl y affect the accurac y of the sensor's m eas urement. Ho wever, whe n a nebuliser or oth er de vice is used t o inc rease m ois ture le vels i n gas m ixtur es, the m oistur e actua ll y dilutes t he m ixture.
24 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T E N E FFECT OF T EMPERATURE The T eledyne E lectron ic T echnolog ies Anal ytical Int ruments sens ors adjus t for ambient tem per ature changes in the ra nge of 0 - 40 ºC (32 - 10 6ºF).
25 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION E LEVEN D ISCREPANCY IN R EADINGS The T ED 191 is intend ed to be used as a secondary oxygen monitor , meani ng that it is int ended to verif y the accur acy of and chec k the oxygen co ncentrat ion l eaving a nother ox ygen m ixing device or prim ar y life support s ystem (i.
26 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T WELVE R EPAIR S ERVICE In the even t that your TED 1 91 Porta ble O xygen Monitor re quir es servic e, th e followi ng s teps wi.
27 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ENSOR C ELL R EPLACEMENT L OG D AT E W AR R AN T Y ?S ERIAL N UMBER R EM ARKS N/A MANUFACT URED.
28 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ECHNIC AL S ERVICE L OG D AT E W AR R AN T Y ?D ETA ILS R EM ARKS.
29 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments G ENERAL N OTES.
30 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S PA RE P AR T S L IST S PA RE P ARTS P AR T N UM BER D ESCRIPT ION A51327 Micro-F uel Cell T-7 with f low diverter P/N A5 0057 C885 Cable a.
Een belangrijk punt na aankoop van elk apparaat Teledyne TED 191 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Teledyne TED 191 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Teledyne TED 191 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Teledyne TED 191 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Teledyne TED 191 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Teledyne TED 191 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Teledyne TED 191 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Teledyne TED 191 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.