Gebruiksaanwijzing /service van het product USDT2004 van de fabrikant Thermo Products
Ga naar pagina of 14
USDT 2004 Installation and User’s Guide Introduction General Information 2 Installation 3 Collector Sensor 3 Control Box 5 Power Connection 6 Display Window 6 Operation Basic Operation (Factory Sett.
2 Introduction Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express or implied, or to form any contract. Thermo Technologies reserves the right to change specifications without prior notice.
3 INSTALLATION Note: This installation procedure is for guidance only, and the installer should verify its suitability. Make sure that the solar system is physically installed, manually tested, and ready for controlled operation. he following sa fety precautions are strongly recommended: 1.
4 strap the sensor to the collector outl et pipe or the absorber (flat plate collectors) that projects from the collector housing. Ideally, house the collector sensor (encased in a suitable sensor pocket) into a T - piece on the collector return outlet.
5 Undo the screw at the top of the housing. The control electronics are mounted on the enclosure cover. The controller enclosure can be screwed to the wall with cable entry grommets pointed downwards. Use the supplied plastic bridges to secure pow er and sensor cables.
6 ower Connections: A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inse rted. NOTE 1: Always disconnect the controller from power supply before opening the housing. NOTE 2: The controller should be properly grounded.
7 Use selection keys ïð during normal system operation to display the desired parameter: T1 xxx Collector temperature in o F T2 xxx Tank temperature in o F T3 xxx Reading of the third sensor; if the.
8 RUV X.X – This display shows the software revision number. NR O – This is PROGRAM 0 which indicates simple operation of unit as a U niversal S olar D ifferential T emperature ( USDT ) controller. Change this value to 1 ( NR 1 ) for activation of the third sensor or puls e flow meter input (PROGRAM 1) .
9 symbol while the pump is running. User can switch to manual mode by pressing ò k ey. By pressing ð key while centerline blinks, a hand symbol G in lower line shows manual operation. Pressing ð one more time lets you turn the pump ON or OFF . By pressing ñ key you change the pump operation.
10 max = 2 Pump runs again below this set point (T3) Energy calculation mode (PROGRAM 1) : USDT 2004 computes the energy production as a function of the temperature diff erential and fluid volume. In addition, the system anti - freeze (Glycol) percentage should be entered as it affects the thermal conductivity and heat transfer rate.
11 START Starts pump at pre - set insolation (solar radiation intensity) ALARM Enables/Disables protection functions BTU Energy calculation and setting ensor Designation – USD T 2004 accepts two different sensor types or a reference value . User can program a constant reference temperature instead of a sensor output.
12 circulation pump runs when the collector temperature is below a programmable minimum temperature, shown by = symbol. The pump stops as soon as the temperature in the solar loop reaches a safe region programmed by the ? symbol. This feature is also disabled at the factory by entering - 4 o F.
13 2 OPEN Disconnection in sensor 2 wiring OK System operates normal NO CIRC r T is more than 108 o F in last 30 minutes OK CIRC Pump is running CLEAR Clears NO CIRC display after correction nergy calculation - Energy gain is calculated by obtaining the temperature increase of heat transfer fluid across the solar collector.
14 T roubleshooting In general, all of the settings in the menus Par and Men and the terminal should f irst be checked if there is a malfunction. Malfunction, but "realistic" temperature values: • Check program number. • Check the switch - on and switch - off thresholds and the set differential temperatures.
Een belangrijk punt na aankoop van elk apparaat Thermo Products USDT2004 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Thermo Products USDT2004 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Thermo Products USDT2004 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Thermo Products USDT2004 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Thermo Products USDT2004 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Thermo Products USDT2004 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Thermo Products USDT2004 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Thermo Products USDT2004 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.