Gebruiksaanwijzing /service van het product Oil-Fired van de fabrikant BCS
Ga naar pagina of 16
W ARNING Improper installation, adjustment, alteration, service or maintenance can cause serious in- jury or property damage. Refer to this manual. For assistance or additional information, con- sult a qualified installer or service agency .
Page 2 Oil-Fired BCS Storage Capacity (gal.) BTUH (Thousands) Firing Rate (GPH) Hot Outlet T emperature Rise (F) OIL-FIRED BCS Instr uction Manual Return Cold Inlet Recovery (GPH) B D 20e-BCS 20 60 0.
Oil-Fired BCS Page 3 WHEN YOU RECEIVE Y OUR NEW W ATER HEA TER Check the new equipment to see if all components are in good condition and were not damaged in shipment. The water heater and burner may be shipped as separate units. The aquastat and immersion well are packed with the burner .
Page 4 Oil-Fired BCS 1. Cut a 7" O.D. opening in the preferred wall and provide a minimum of 1 ⁄ 2 " clearance of non-combustible space around the Balanced Flue. The opening should allow for a 1 ⁄ 2 " downward pitch to the outside for drainage of any condensate in the Balanced Flue.
Oil-Fired BCS Page 5 CONNECT W ATER PIPING Be careful not to apply any heat to the water heater nipples. Install dielectric unions and shut off valves on both hot and cold water lines. 40 BCS models are equipped with a brass inlet bushing in- stalled in the tank.
Page 6 Oil-Fired BCS FRESH AIR INTAKE VENT Proper sealing of the fresh air intake vent material is important, but temperature is not an issue. Failure to properly seal the inlet venting subjects the burner to possible reverse drafts after burner shutdown— a hazardous condition with the possibility of creating a fire .
Oil-Fired BCS Page 7 CONNECT THE OIL LINE Gravity System: The oil burner is normally equipped with a single-stage pump equipped for one line (gravity) flow . Use 3 ⁄ 8 " O.D. or larger soft copper tubing and attach with flared fittings. DO NOT USE COMPRESSION FITTINGS.
Page 8 Oil-Fired BCS PLA CE W A TER SYSTEM IN OPERA TION 1. Fill the tank with water , opening a hot water faucet to allow trapped air to escape from the heater . Open the cold water inlet valves. Shut off each faucet as it delivers water that is free of air .
Oil-Fired BCS Page 9 MEASURING THE OUTCOMING W ATER TEMPERA TURE, CON’T W ARNING: Hydr ogen gas can be produced in a hot water system served by a heater that has not been used for a long period of time (generally two weeks or more). Hydr ogen gas is extremely flammable.
SERVICE 1. Check the fuel supply , electrical wiring, fuses, and make sure the temperature control is calling for heat. 2. If the motor runs but there is no flame, remove the electrode assembly , clean, readjust, and check the porcelain for cracks. Replace if necessary .
Oil-Fired BCS Page 11 COMP ANY’S RESPONSIBILITY The company’ s responsibility is to repair or replace, at our option, with the prevailing compa- rable Bock model, any part of the equipment, includ.
OUR TO T AL W ARRANTY COMMITMENT W e will not assume, nor authorize any person to assume for us, any other liability in connec- tion with the sale or operation of Bock W ater Heaters.
Oil-Fired BCS Page 13 BOCK OIL-FIRED W ATER HEA TER.
Page 14 Oil-Fired BCS Balanced Flue ™ BURNER WIRE DIA GRAM Models 20, 32,40,51,120,190E-BCS Carlin EZ-T emp Control.
Oil-Fired BCS Page 15 EXP ANSION T ANK (OPTIONAL) IF ANY OF THESE DEVICES ARE USED, A PROPERL Y SIZED EXP ANSION T ANK MUST BE INST ALLED..
Page 16 Oil-Fired BCS Form # 23390 Rev 3 3/2007 BCS AND RADIANT HEA T Radiant heating: An in-floor hot water space heating system A Bock high-efficiency water heater and zoned radiant heating— Bock&Radiant —make perfect partners for cost-effective personal comfort that heats both space and water .
Een belangrijk punt na aankoop van elk apparaat BCS Oil-Fired (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen BCS Oil-Fired heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens BCS Oil-Fired vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding BCS Oil-Fired leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over BCS Oil-Fired krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van BCS Oil-Fired bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de BCS Oil-Fired kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met BCS Oil-Fired . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.