No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001.
No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation.
No. MIIXR0002EAC Table of Contents Page 1 INTRODUCT ION ................................................................................................................ 1 1.1 R EFERENCES ................................................................
No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules ................................................................ 9 8.1.2 Media Storage XA IOD Modules .......................................................................... 9 8.1.3 XA IOD Modules .
No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments.
No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Sy mbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • .
No. MIIXR0002EAC 2 Implement ation Model 2.1 Application Data Flow Diagram Transfer of X-r a y Examinat ion DICOM Recording CD-R Medium Review of X-r a y Examinat ion DICOM Reader Legend Applicati on Entity Local Real-W orld Activi ty File-set Creator (FS C) File-set Reader (FS R) Local Relationship Figure 1 2.
No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represent s the contents of t he data as recorded. • Displays the ordered list of patient and image identifying information or icon images.
No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media.
No. MIIXR0002EAC 3 AE Sp ecifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and t he Media Storage Application Profile.
No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relev ant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator.
No. MIIXR0002EAC 5 Extensions, S pecializations, and Privatizations of SOP Classes and T ransfer Synt axes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set.
No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage 1 DICOM File Meta Information 8.
No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage 1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equi pment Module 8.
No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Alw ays set DICOM Prefi.
No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Attribute Description Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set O.
No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag T ype Attribute Description Study Date (0008, 0020) 1 Alway s set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Le.
No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type A ttribute Description Instance Number (0020, 0013) 1 Alway s set Image Type (0008, 0008) 1 Alway s set Image Date (0008, 0023) 3 Alw.
No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Attribute Description Patient's Name (0010, 0010) 2 Always set except for urgent patie.
No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Attribute Description Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Alway s set S.
No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Attribute Description Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always s.
No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Attribute Description Frame Increment Pointer (0028, 0009) 1C Always set (0x00181063) Image Type (0008, 0008) 1 Alw ays set .
No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification Fact.
Een belangrijk punt na aankoop van elk apparaat Toshiba DFP-2000A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Toshiba DFP-2000A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Toshiba DFP-2000A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Toshiba DFP-2000A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Toshiba DFP-2000A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Toshiba DFP-2000A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Toshiba DFP-2000A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Toshiba DFP-2000A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.