Manual

Medium Temperature Refrigerated Display Cases
This manual has been designed to be used in conjunction with the General
(UL/NSF) Installation & Service Manual. Save the Instructions in Both Manuals for Future Reference!!
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 1999.
PRINTED IN Specifications subject to REPLACES ISSUE PART IN U.S.A. change without notice. EDITION DATE 1/01 NO. 9037155 REV.
Tyler Refrigeration Corporation * Niles, Michigan 49120



NSF Product Thermometer 14 Service Instructions
Preventive Maintenance (See General-UL/NSF I&S Manual) Troubleshooting Self-Contained Units 15 Light Servicing Ballast and Lighting Locations 16 Fan Blade and Motor Replacement (See Gen.-UL/NSF I&S Manual) Color Band and Bumper Replacement (See Gen.-UL/NSF I&S Man.) Parts Information
Operational Parts List 17 Cladding and Optional Trim Parts List 18 TYLER Warranty (See General-UL/NSF I&S Manual)
The following Narrow Medium Temperature Dairy and Deli Merchandiser models are covered in this manual:
N5D 4’, 6’ & 8’ REMOTE MULTI-DECK DAIRY/DELI MERCHANDISER
N5DH 4’, 6’ & 8’ REMOTE DEEP WELL MULTI-DECK DAIRY/DELI MERCHANDISER
N5DL 4’, 6’ & 8’ REMOTE LOW FRONT MULTI-DECK DAIRY/DELI MERCHANDISER





This circuit is to be supplied by an uninter- rupted, protected 120V circuit. The case fan circuit is not cycled during defrost on any of these models.
Case Pull-Up Locations

N5D/N5DH/N5DL/N5DSC case lighting is supplied by 800MA HO horizontal lights. It is controlled by a light switch in each case. The standard lighting is 1-row of high output 800MA canopy lights. N5D/N5DH/N5DL/N5DSC also offers up to 4 rows of T-8 shelf lights with remote electronic ballasts.
LNDSC cases are self-contained units. Information pertaining to self-contained units should be obtained directly from TYLER Refrigeration. Defrost Information
See “General-UL/NSF I&S Manual” for operational descriptions for Off Time defrost control.
The N5D, N5DH, N5DL and N5DSC models have four pull-ups at each end of the case. Pull-ups A, B, C and D are located as shown and should be install-ed and tightened starting with A and finishing with D.
Defrost Defrost Defrosts Duration Term. Type Per Day (Min) Temp. Off Time 4 24
ELECTRICIAN NOTE - OVERCURRENT
PROTECTION
120V circuits should be protected by 15 or 20 Amp devices per the requirements noted on the cabinet nameplate or the National Electrical Code, Canadian Electrical Code - Part 1, Section 28. 208V defrost circuits employ No. 12 AWG field wire leads for field connections. On remote cases intended for end to end line-ups, bonding for ground may rely upon the pull-up bolts.
CAUTION
Make sure all electrical connections at com- ponents and terminal blocks are tight.
The following wiring diagrams on pages 7 thru 12 will cover the N5D, N5DH, N5DL and N5DSC case circuits and the lighting circuits.
Since the lower front cladding is shipped loose, the wiring has immediate access.















CLEANING AND SANITATION
Rear duct panels with electrical recepta- cles can be cleaned without removing the electrical receptacles. Do not get moisture on electrical wires when cleaning under this cover. Moisture on wires could cause premature product failure and/or personal injury or death from electrical shock.
NOTE
Improper installation of the honeycomb grid section could result in improper air flow and/or poor refrigeration.

GENERAL INFORMATION
For ease of installation, position the wash- ers and capnuts on the top side of the bracket and bottom tray.


SERVICE INSTRUCTIONS
WARNING
Never work on electrically powered equipment while it is energized! Electrical shock could cause personal injury and/or death.
Low voltage Check outlet with voltmeter. Voltage should be 115V or 220V (±10%).
Inoperative motor or Check connections. temperature control
Thermostat set incorrectly Check setting.
Pressure control set Check setting. incorrectly
Case fans not operating Check terminal block connections.
Pressure control set Check setting. incorrectly
Room temperature Ventilate room appropriately. too warm
Thermostat set incorrectly Reset thermostat.
Refrigerant charge low Have unit serviced by a qualified service technician.
Tubing contacting cabinet Move tubing. or other tubing
Cabinet not level Level cabinet.
Dissipator not functioning Check electrical supply. Check float assembly.

Ballast and Lighting Locations

All light ballasts are located under the canopy and mounted on the top of the canopy light channel. This includes remote ballasts for optional shelf lights. The canopy light(s) are under the canopy light channel in the top of the case. The optional shelf lights are mount- ed in separate light channels under the front of each shelf section.
See “General-UL/NSF I&S Manual” for 800MA and T-8 ballast and lamp, fan blade & motor and color band & bumper replace- ment instructions.

PARTS INFORMATION
Case Usage Domestic Export
Electrical Circuit 115 Volt 60 Hertz 220 Volt 50 Hertz
Case Size 4’ 6’ 8’ 4’ 6’ 8’
Fan Motors 5125532 5125532 5125532 5126572 5126572 5126572 (N5D/N5DH/N5DL) 5 Watt 5 Watt 5 Watt 5 Watt 5 Watt 5 Watt
Fan Motors (N5DSC) 5125532 5125532 5 Watt 5 Watt
Fan Motor Brackets 5962269
Fan Bracket Plate 9041077
Fan Blades (7” 40° 5B) 5221604
Opt. ECM Fan Motors 9025002 (N5D/N5DH/N5DL) 8 Watt 8 Watt 8 Watt 8 Watt 8 Watt 8 Watt
Opt. ECM Fan Motors 9025002 (N5DSC) 8 Watt 8 Watt 8 Watt 8 Watt
Opt. ECM Motor Brackets 9025005
Opt. ECM Fan Blades 5223370 (7” 30° 5B)
800MA Ballast (canopy) 5049140 5049140 5049140 5232195 5232195 5232195
Opt. T-8 Ballast
(can. 1-row) 5991029 5991029 5991029 9322286 9322286 9322286
(can. 2-row) 5966635 5966635 5966635 9322286 9322286 9322286
(shelf) 5966635 5966635 5966635 9322288 9322288 9322288
800MA Lampholder (telescoping) 5614628
(stationary) 5614629
T-8 Lampholder (canopy) 9041897
(shelf) 9041897
Self-Cont. Compressor
Compressor Model No.
Condensate Pan (N5DSC) 9601926 5966037
NSF Product Thermometer 5967100
For information on operational parts not listed above contact the TYLER Service Parts Department.

Item Description N5D/N5DH/N5DL N5DSC
4’ 6’ 8’ 4’ 6’
1 Screw 5183536(3) 5183536(4) 5183536(6) 5183536(3) 5183536(4)
2 Close-off, Hood 9026366 9026367 9026368 9026366 9026367
3 Canopy Backer, Ptd. 9026364
4 Canopy Hood, Ptd. 9025968 9025969 9025970 9025968 9025969
5 Screw 9025833
6 Bumper Retainer/Hand Rail color by order
7 Hand Rail Backer, Ptd. 9025316
8 Color Band, Ptd. 9023791 9023796 9023799 9023791 9023796
9 Color Band Backer, Ptd. 9040223
10 Bumper color by order
11 Bumper Backer color by order
12 Bumper End Trim color by order
13 Lwr. Frt. Cladding, Ptd. (N5D / N5DSC) 9025459 9025460 9025461
(N5DSC) ----- ----- ----- 9603773 9603774
14 Upr. Frt. Cladding, Ptd. (N5D / N5DL) 9025462 9025463 9025464
(N5DSC) ----- ----- ----- 9025462 9025463
15 Screw 5183536(10)5183536(12)5183536(15) 5183536(10)5183536(12)
16 Kickplate color by order
Kickplate Backer 9023569
17 Screw 9029131(6) 9029131(6) 9029131(8) 9029131(6) 9029131(6)
18 Kickplate Support 9023565(3) 9023565(3) 9023565(4) 9023565(3) 9023565(3)
19 LH End Close-off, Ptd. 9022469
RH End Close-off, Ptd. 9022471
20 Screw 5048626(2)