Inhoudsopgave 54 secties Installation & Service · Manual · N5D, N5DH, N5DL, N5DSC · NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS · … TonenVerbergen
Installation & Servicep.1Manualp.1N5D, N5DH, N5DL, N5DSCp.1NARROW MULTI-DECK DAIRY/DELI MERCHANDISERSp.1Medium Temperature Refrigerated Display Casesp.1Installation & Service Manual N5D, N5DH, N5DL, N5DSCp.3Page General Informationp.3MODELS DESCRIPTIONp.3N5DSC 4’ & 6’ SELF-CONTAINED MULTI-DECK DAIRY/DELI MERCHANDISERp.3SPECIFICATIONSp.4N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiserp.4INSTALLATION PROCEDURESp.6Carpentry Proceduresp.6Case Pull-Up Locationsp.6WIRING DIAGRAMSp.6See “General-UL/NSF I&S Manual” for lineup assembly instructions. Electrical Proceduresp.6ELECTRICIAN NOTE - OVERCURRENTp.6PROTECTIONp.6Electrical Considerationsp.6CAUTIONp.6NOTEp.6800MA Canopy Lighting Circuitp.11Optional Canopy Lighting Circuitp.11Optional Shelf Lighting Circuits 4’ Casesp.126’ & 8’ Casesp.12CLEANING AND SANITATIONp.13(with Shelf Light Sockets)p.13Component Removal and Installation Instructions for Cleaningp.13Mirrorsp.13WARNINGp.13Shelves and Shelf Bracketsp.13Discharge Air Honeycombp.13Bottom Traysp.13Front Air Ductsp.13Rear Duct Panels (w/o Shelf Light Sockets)p.13Top Ductp.14GENERAL INFORMATIONp.14NSF Product Thermometer Installationp.14Lower Claddingp.14Upper Claddingp.14SERVICE INSTRUCTIONSp.15Troubleshooting Self-Contained Unitsp.15TROUBLE COMMON CAUSE REMEDYp.15Light Servicingp.16Ballast and Lighting Locationsp.16PARTS INFORMATIONp.17Operational Parts Listp.17(N5DSC) 5965977 5965978 ---- ---- ---- ----p.17(N5DSC) REK3-0125-PFV REY3-0175-PFV ---- ---- ---- ----p.17Cladding and Optional Trim Parts Listp.18(N5DH) 9026305 9026306 9026307 ----- -----p.18(N5DSC) ----- ----- ----- 9603773 9603774p.18(N5DH) 9026308 9026309 9026310 ----- -----p.18(N5DSC) ----- ----- ----- 9025462 9025463p.18
Page 1 of the Tyler Refrigeration N5D user manual — NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS
Pagina 1 · klik om te vergroten
Pagina 1
Tyler Refrigeration N5D — Installation & Service diagram (page 1)
Afb. 1 · Installation & Service
Tyler Refrigeration N5D — Installation & Service diagram (page 1)
Afb. 2 · Installation & Service

Installation & Service

Manual

Tyler Refrigeration N5D — Installation & Service diagram (page 1)
Afb. 3 · Installation & Service

N5D, N5DH, N5DL, N5DSC

NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS

Medium Temperature Refrigerated Display Cases

This manual has been designed to be used in conjunction with the General

(UL/NSF) Installation & Service Manual. Save the Instructions in Both Manuals for Future Reference!!

This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 1999.

PRINTED IN Specifications subject to REPLACES ISSUE PART IN U.S.A. change without notice. EDITION DATE 1/01 NO. 9037155 REV.

Tyler Refrigeration Corporation * Niles, Michigan 49120

Page 2 of the Tyler Refrigeration N5D user manual — Installation & Service
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Tyler Refrigeration N5D user manual — Installation & Service
Page 3 of the Tyler Refrigeration N5D user manual — N5DSC 4’ & 6’ SELF-CONTAINED MULTI-DECK DAIRY/DELI MERCHANDISER
Pagina 3 · klik om te vergroten
Pagina 3

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

Page General Information

NSF Product Thermometer 14 Service Instructions

Preventive Maintenance (See General-UL/NSF I&S Manual) Troubleshooting Self-Contained Units 15 Light Servicing Ballast and Lighting Locations 16 Fan Blade and Motor Replacement (See Gen.-UL/NSF I&S Manual) Color Band and Bumper Replacement (See Gen.-UL/NSF I&S Man.) Parts Information

Operational Parts List 17 Cladding and Optional Trim Parts List 18 TYLER Warranty (See General-UL/NSF I&S Manual)

The following Narrow Medium Temperature Dairy and Deli Merchandiser models are covered in this manual:

MODELS DESCRIPTION

N5D 4’, 6’ & 8’ REMOTE MULTI-DECK DAIRY/DELI MERCHANDISER

N5DH 4’, 6’ & 8’ REMOTE DEEP WELL MULTI-DECK DAIRY/DELI MERCHANDISER

N5DL 4’, 6’ & 8’ REMOTE LOW FRONT MULTI-DECK DAIRY/DELI MERCHANDISER

N5DSC 4’ & 6’ SELF-CONTAINED MULTI-DECK DAIRY/DELI MERCHANDISER

Page 4 of the Tyler Refrigeration N5D user manual — N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser
Pagina 4 · klik om te vergroten
Pagina 4

SPECIFICATIONS

N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser

Tyler Refrigeration N5D — N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser diagram (page 4)
Afb. 4 · N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandis…
Page 5 of the Tyler Refrigeration N5D user manual — N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser
Pagina 5 · klik om te vergroten
Pagina 5

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser

Tyler Refrigeration N5D — N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser diagram (page 5)
Afb. 5 · N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandis…
Page 6 of the Tyler Refrigeration N5D user manual — NOTE
Pagina 6 · klik om te vergroten
Pagina 6

INSTALLATION PROCEDURES

This circuit is to be supplied by an uninter- rupted, protected 120V circuit. The case fan circuit is not cycled during defrost on any of these models.

Carpentry Procedures

Case Pull-Up Locations

Tyler Refrigeration N5D — Carpentry Procedures diagram (page 6)
Afb. 6 · Carpentry Procedures

N5D/N5DH/N5DL/N5DSC case lighting is supplied by 800MA HO horizontal lights. It is controlled by a light switch in each case. The standard lighting is 1-row of high output 800MA canopy lights. N5D/N5DH/N5DL/N5DSC also offers up to 4 rows of T-8 shelf lights with remote electronic ballasts.

LNDSC cases are self-contained units. Information pertaining to self-contained units should be obtained directly from TYLER Refrigeration. Defrost Information

See “General-UL/NSF I&S Manual” for operational descriptions for Off Time defrost control.

The N5D, N5DH, N5DL and N5DSC models have four pull-ups at each end of the case. Pull-ups A, B, C and D are located as shown and should be install-ed and tightened starting with A and finishing with D.

Defrost Defrost Defrosts Duration Term. Type Per Day (Min) Temp. Off Time 4 24

WIRING DIAGRAMS

See “General-UL/NSF I&S Manual” for lineup assembly instructions. Electrical Procedures

ELECTRICIAN NOTE - OVERCURRENT

PROTECTION

120V circuits should be protected by 15 or 20 Amp devices per the requirements noted on the cabinet nameplate or the National Electrical Code, Canadian Electrical Code - Part 1, Section 28. 208V defrost circuits employ No. 12 AWG field wire leads for field connections. On remote cases intended for end to end line-ups, bonding for ground may rely upon the pull-up bolts.

Electrical Considerations

CAUTION

Make sure all electrical connections at com- ponents and terminal blocks are tight.

NOTE

The following wiring diagrams on pages 7 thru 12 will cover the N5D, N5DH, N5DL and N5DSC case circuits and the lighting circuits.

Since the lower front cladding is shipped loose, the wiring has immediate access.

Show 4 more labels / short text on this page
Case Fan Circuit · Fluorescent Lamp Circuit · Self-Contained Circuit · Defrost Control Chart
Page 7 of the Tyler Refrigeration N5D user manual — INSTALLATION PROCEDURES
Pagina 7 · klik om te vergroten
Pagina 7
Tyler Refrigeration N5D — INSTALLATION PROCEDURES diagram (page 7)
Afb. 7
Page 8 of the Tyler Refrigeration N5D user manual — INSTALLATION PROCEDURES
Pagina 8 · klik om te vergroten
Pagina 8
Tyler Refrigeration N5D — INSTALLATION PROCEDURES diagram (page 8)
Afb. 8
Page 9 of the Tyler Refrigeration N5D user manual — INSTALLATION PROCEDURES
Pagina 9 · klik om te vergroten
Pagina 9
Tyler Refrigeration N5D — INSTALLATION PROCEDURES diagram (page 9)
Afb. 9
Page 10 of the Tyler Refrigeration N5D user manual — INSTALLATION PROCEDURES
Pagina 10 · klik om te vergroten
Pagina 10
Tyler Refrigeration N5D — INSTALLATION PROCEDURES diagram (page 10)
Afb. 10
Page 11 of the Tyler Refrigeration N5D user manual — Optional Canopy Lighting Circuit
Pagina 11 · klik om te vergroten
Pagina 11

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

800MA Canopy Lighting Circuit

Tyler Refrigeration N5D — 800MA Canopy Lighting Circuit diagram (page 11)
Afb. 11 · 800MA Canopy Lighting Circuit

Optional Canopy Lighting Circuit

Tyler Refrigeration N5D — Optional Canopy Lighting Circuit diagram (page 11)
Afb. 12 · Optional Canopy Lighting Circuit
Page 12 of the Tyler Refrigeration N5D user manual — 6’ & 8’ Cases
Pagina 12 · klik om te vergroten
Pagina 12

Optional Shelf Lighting Circuits 4’ Cases

Tyler Refrigeration N5D — Optional Shelf Lighting Circuits 4’ Cases diagram (page 12)
Afb. 13 · Optional Shelf Lighting Circuits 4’ Cases

6’ & 8’ Cases

Tyler Refrigeration N5D — 6’ & 8’ Cases diagram (page 12)
Afb. 14 · 6’ & 8’ Cases
Page 13 of the Tyler Refrigeration N5D user manual — Rear Duct Panels (w/o Shelf Light Sockets)
Pagina 13 · klik om te vergroten
Pagina 13

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

CLEANING AND SANITATION

(with Shelf Light Sockets)

1. Remove mirrors, shelves and bottom trays, see this page.

Component Removal and Installation Instructions for Cleaning

2. Remove mounting screws from rear duct panel.

Mirrors

3. Slowly lift out rear duct panel until the shelf harness connector near the top of the panel can be accessed.
1. Remove mounting screws and end molding of mirror line-up.
2. Carefully grasp and lift mirror section until bottom edge clears the lower mirror track.
4. Disconnect shelf harness connector and complete removing the rear duct panel.
3. Carefully lower mirror out of upper mirror track and remove from case.

WARNING

Rear duct panels with electrical recepta- cles can be cleaned without removing the electrical receptacles. Do not get moisture on electrical wires when cleaning under this cover. Moisture on wires could cause premature product failure and/or personal injury or death from electrical shock.

4. After cleaning, replace in reverse order.

Shelves and Shelf Brackets

1. Remove product from shelves.
2. If shelf has a light, unplug the light cord from the socket in the rear duct panel. Completely insert socket cover in the light socket to protect the receptacle.
5. After cleaning, reconnect the shelf harness connector: install the top socket assembly: replace and secure rear duct panels in reverse order.
3. Push shelves back and then lift up and out to remove them from the shelf brackets.
4. Remove shelf brackets from slots in rear uprights.

Discharge Air Honeycomb

5. After cleaning, replace in reverse order.
1. Loosen screws securing rear retainer plate.

Bottom Trays

NOTE

1. Remove product from bottom of case.
2. Grasp and lift out each of the bottom trays from the case interior.
3. After cleaning, replace in reverse order.
2. Slide rear retainer plate back until the honeycomb grid sections can be removed from the top duct.

Front Air Ducts

1. Remove lower trays, see this page.

CAUTION

2. Lift out front air duct sections.

Improper installation of the honeycomb grid section could result in improper air flow and/or poor refrigeration.

3. After cleaning, replace in reverse order.

Rear Duct Panels (w/o Shelf Light Sockets)

3. After cleaning, replace honeycomb grid sections as they were removed and secure with the rear retainer plate and screws.
1. Remove shelves and bottom trays, see above.
2. Remove mounting screws and rear duct panels from case.
3. After cleaning, replace and secure rear duct panels in reverse order.
Page 14 of the Tyler Refrigeration N5D user manual — Upper Cladding
Pagina 14 · klik om te vergroten
Pagina 14

Top Duct

GENERAL INFORMATION

1. Remove shelves and shelf brackets, see page 13.

NSF Product Thermometer Installation

2. Remove screws, rear retainer plate and honeycomb grid sections from top of case.
1. Unwrap the thermometer and bracket assembly shipped loose with the case.
3. Remove screws and top duct from case.
2. Position bracket in front right corner of the right-most bottom tray. Making sure the bracket is 5/8” in from the right edge, use the bracket holes as a template for where to drill the holes.
4. After cleaning, replace top duct and remaining components in reverse order.

Lower Cladding

1. Remove front kickplate form kickplate supports. (See General-UL/NSF I&S Manual.)
3. Drill two .196” holes in the bottom tray.
2. Remove mounting screws from top and bottom of lower cladding and remove lower cladding.

NOTE

For ease of installation, position the wash- ers and capnuts on the top side of the bracket and bottom tray.

3. After cleaning, replace in reverse order.

Upper Cladding

Tyler Refrigeration N5D — Upper Cladding diagram (page 14)
Afb. 15 · Upper Cladding
1. Remove lower cladding, see this page.
2. Remove color band, bumper and bumper retainer from the case. (See GeneralUL/NSF I&S Manual.)
3. Remove screws for top and bottom of upper cladding and remove upper cladding.
4. Mount the bracket to the bottom tray with two screws, washers and capnuts.
4. After cleaning, replace upper cladding and remaining front components in reverse order.
Page 15 of the Tyler Refrigeration N5D user manual — TROUBLE COMMON CAUSE REMEDY
Pagina 15 · klik om te vergroten
Pagina 15

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

SERVICE INSTRUCTIONS

Troubleshooting Self-Contained Units

WARNING

Never work on electrically powered equipment while it is energized! Electrical shock could cause personal injury and/or death.

TROUBLE COMMON CAUSE REMEDY

1. Unit will not run Blown fuse Replace fuse.

Low voltage Check outlet with voltmeter. Voltage should be 115V or 220V (±10%).

Inoperative motor or Check connections. temperature control

2. Refrigerated section Shelves overloaded; Make sure items do not block the is too warm blocked air flow air flow.

Thermostat set incorrectly Check setting.

Pressure control set Check setting. incorrectly

Case fans not operating Check terminal block connections.

3. Refrigerated section Thermostat set incorrectly Check setting. too cold

Pressure control set Check setting. incorrectly

4. Unit runs all the time Inadequate air circulation Relocate cabinet or remove obstruction. Check installation requirements.

Room temperature Ventilate room appropriately. too warm

Thermostat set incorrectly Reset thermostat.

Refrigerant charge low Have unit serviced by a qualified service technician.

5. Noisy operation Loose baffles Tighten or brace baffles.

Tubing contacting cabinet Move tubing. or other tubing

Cabinet not level Level cabinet.

6. Frost or ice on Defrost clock doesn’t work Check electrical conections. Have evaporator coil unit serviced by a qualified service technician.
7. Water dripping from Condensate drain clogged Clear drain. case drain

Dissipator not functioning Check electrical supply. Check float assembly.

Page 16 of the Tyler Refrigeration N5D user manual — NOTE
Pagina 16 · klik om te vergroten
Pagina 16

Light Servicing

Ballast and Lighting Locations

Tyler Refrigeration N5D — Light Servicing diagram (page 16)
Afb. 16 · Light Servicing

All light ballasts are located under the canopy and mounted on the top of the canopy light channel. This includes remote ballasts for optional shelf lights. The canopy light(s) are under the canopy light channel in the top of the case. The optional shelf lights are mount- ed in separate light channels under the front of each shelf section.

NOTE

See “General-UL/NSF I&S Manual” for 800MA and T-8 ballast and lamp, fan blade & motor and color band & bumper replace- ment instructions.

Page 17 of the Tyler Refrigeration N5D user manual — (N5DSC) REK3-0125-PFV REY3-0175-PFV ---- ---- ---- ----
Pagina 17 · klik om te vergroten
Pagina 17

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

PARTS INFORMATION

Operational Parts List

Case Usage Domestic Export

Electrical Circuit 115 Volt 60 Hertz 220 Volt 50 Hertz

Case Size 4’ 6’ 8’ 4’ 6’ 8’

Fan Motors 5125532 5125532 5125532 5126572 5126572 5126572 (N5D/N5DH/N5DL) 5 Watt 5 Watt 5 Watt 5 Watt 5 Watt 5 Watt

Fan Motors (N5DSC) 5125532 5125532 5 Watt 5 Watt

Fan Motor Brackets 5962269

Fan Bracket Plate 9041077

Fan Blades (7” 40° 5B) 5221604

Opt. ECM Fan Motors 9025002 (N5D/N5DH/N5DL) 8 Watt 8 Watt 8 Watt 8 Watt 8 Watt 8 Watt

Opt. ECM Fan Motors 9025002 (N5DSC) 8 Watt 8 Watt 8 Watt 8 Watt

Opt. ECM Motor Brackets 9025005

Opt. ECM Fan Blades 5223370 (7” 30° 5B)

800MA Ballast (canopy) 5049140 5049140 5049140 5232195 5232195 5232195

Opt. T-8 Ballast

(can. 1-row) 5991029 5991029 5991029 9322286 9322286 9322286

(can. 2-row) 5966635 5966635 5966635 9322286 9322286 9322286

(shelf) 5966635 5966635 5966635 9322288 9322288 9322288

800MA Lampholder (telescoping) 5614628

(stationary) 5614629

T-8 Lampholder (canopy) 9041897

(shelf) 9041897

Self-Cont. Compressor

(N5DSC) 5965977 5965978

Compressor Model No.

(N5DSC) REK3-0125-PFV REY3-0175-PFV

Condensate Pan (N5DSC) 9601926 5966037

NSF Product Thermometer 5967100

For information on operational parts not listed above contact the TYLER Service Parts Department.

Page 18 of the Tyler Refrigeration N5D user manual — (N5DH) 9026308 9026309 9026310 ----- -----
Pagina 18 · klik om te vergroten
Pagina 18

Cladding and Optional Trim Parts List

Item Description N5D/N5DH/N5DL N5DSC

4’ 6’ 8’ 4’ 6’

1 Screw 5183536(3) 5183536(4) 5183536(6) 5183536(3) 5183536(4)

2 Close-off, Hood 9026366 9026367 9026368 9026366 9026367

3 Canopy Backer, Ptd. 9026364

4 Canopy Hood, Ptd. 9025968 9025969 9025970 9025968 9025969

5 Screw 9025833

6 Bumper Retainer/Hand Rail color by order

7 Hand Rail Backer, Ptd. 9025316

8 Color Band, Ptd. 9023791 9023796 9023799 9023791 9023796

9 Color Band Backer, Ptd. 9040223

10 Bumper color by order

11 Bumper Backer color by order

12 Bumper End Trim color by order

13 Lwr. Frt. Cladding, Ptd. (N5D / N5DSC) 9025459 9025460 9025461

(N5DH) 9026305 9026306 9026307

(N5DSC) ----- ----- ----- 9603773 9603774

14 Upr. Frt. Cladding, Ptd. (N5D / N5DL) 9025462 9025463 9025464

(N5DH) 9026308 9026309 9026310

(N5DSC) ----- ----- ----- 9025462 9025463

15 Screw 5183536(10)5183536(12)5183536(15) 5183536(10)5183536(12)

16 Kickplate color by order

Kickplate Backer 9023569

17 Screw 9029131(6) 9029131(6) 9029131(8) 9029131(6) 9029131(6)

18 Kickplate Support 9023565(3) 9023565(3) 9023565(4) 9023565(3) 9023565(3)

19 LH End Close-off, Ptd. 9022469

RH End Close-off, Ptd. 9022471

20 Screw 5048626(2)

Page 19 of the Tyler Refrigeration N5D user manual — Installation & Service Manual N5D, N5DH, N5DL, N5DSC
Pagina 19 · klik om te vergroten
Pagina 19

Installation & Service Manual N5D, N5DH, N5DL, N5DSC

Tyler Refrigeration N5D — Installation & Service Manual N5D, N5DH, N5DL, N5DSC diagram (page 19)
Afb. 17 · Installation & Service Manual N5D, N5DH, N5DL, N5DSC

Vraag stellen over de Tyler Refrigeration N5D

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Tyler Refrigeration N5D

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Tyler Refrigeration N5D handleiding-pdf

19 pagina's·358 KB·Koelkast·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…