Gebruiksaanwijzing /service van het product PFI van de fabrikant Ultratec
Ga naar pagina of 16
Power F ogger Industrial Line and PFI w/ LSG Operator’ s Manual www .ultratecfx.com VER. 30.10.10.
T able of Contents Introduction ................................................................................ 3 Micropr ocessor Control ............................................................ 3 W ater Base Fog T echnology .....................
www .ultratecfx.com 3 Intr oduction The Power Fogger Industrial is a Micropr ocessor Controlled, W ater Based Fog generating system. Micr oprocessor Contr ol The PFI features dual micr oprocessor control. Fr om temperature r egulation to taper back ow control, all of the functions are monitor ed and processed by the two on-board pr ocessors.
www .ultratecfx.com 4 PFI T echnical Specications Model: PFI/PFI-9D Part Number: PFI CLF 4450 / 120 volt CLF 4451 / 220-240 volt PFI-9D CLF 4460 / 110 volt CLF 4461 / 220-240 volt Power Rating: 120 V olt A.C. 50/60 Hz. 13 Amps. 240 V olt A.C. 50/60 Hz.
www .ultratecfx.com 5 Power Fogger Industrial 9D.
www .ultratecfx.com 6 LSG PFI System in a Roadcase 39.5 28.75 34.5 23.25 29.6 24 20 36 32.2 22 28.02 LSG w/ PFI T echnical Drawings LSG PFI System on a Cart.
www .ultratecfx.com 7 Operating Pr ocedure 1. The fog machine must be connected to a grounded supply of at least 15 amps fr ee of any interference. 2. Open a 20 Litre (5 Gallon) container of Ultratec Special Ef fects fog uid and insert the uid pickup tube into the spout of the uid container .
www .ultratecfx.com 8 Operation Pr ocedure LSG MK II High Pr essure w/ 20 & 50lbs Cylinders The Operation Procedur es outlined in this section, refer to Figure A and Figur e B on Page 9 and 10 . 1. Place the fog machine’ s output nozzle rmly against the center of the foam ring, sealing it to the input port of the LSG MK II.
www .ultratecfx.com 9 9. V erify cool temperature output by using your hand and passing it thr ough the fog-CO2 output noting the temperature. 10. After use, tur n off the valves and trigger the LSG MK II to depr essurize the system before attempting to disconnect hoses.
www .ultratecfx.com 10 Figur e B Liquid Carbon Dioxide LSG Control Signal Installation Model Shown Above T ouring Model Available High Pressure Bottles w/ Liquid Siphon Tube Liquid Carbon Dioxide Liqu.
www .ultratecfx.com 11 Operation Pr ocedure LSG MK II Low Pr essure w/ 350lbs Dewar T ank The Operation Procedur es outlined in this section, refer to Figure C on Page 12. 1. Place the fog machine’ s output nozzle rmly against the center of the foam ring sealing it to the input port of the LSG MK II.
www .ultratecfx.com 12 10. V erify cool temperature output by using your hand and passing it through the fog-CO2 output noting the temperature. 11. After use, tur n off the valves and trigger the LSG MK II to depr essurize the system before attempting to disconnect the hoses.
www .ultratecfx.com 13 Options Remotes - The Show Control Remote and Timer/ Duration Remote are compatible with the Power Fog Industrial, Power Fog Industrial w/ Air Option, Power Fog Industrial 9D and Power Fog Industrial 9D w/ Air Option. Each remote is sold separately .
www .ultratecfx.com 14 Closed “Dry” Contact Show Control Show Contr ol Operation Show control is achieved by connecting a “Dry” or zer o voltage contact to the show control terminals. The Power Fog Industrial r equires no power to signal the fog, only one set of contacts that close for the entire fogging cue.
www .ultratecfx.com 15 DMX Operation The Power Fog Industrial is equipped with DMX controls as a standar d feature. 1. Attach a DMX signal to the DMX IN 5 pin connector on the rear of the unit. A terminator may be r equired on the DMX OUT connector in some applications.
www .ultratecfx.com 16 Contact Information Head Ofce Ultratec Special Effects Inc. 1960 Blue Heron Drive London, Ontario N6H 5L9 Direct: 519-659-7972 T oll Free: 866-534-5557 Fax: 519-659-7713 Canadian Shipping Address (For All Canadian Repairs) Ultratec Special Effects Inc.
Een belangrijk punt na aankoop van elk apparaat Ultratec PFI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Ultratec PFI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Ultratec PFI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Ultratec PFI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Ultratec PFI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Ultratec PFI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Ultratec PFI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Ultratec PFI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.