Gebruiksaanwijzing /service van het product MS337 van de fabrikant Unitech
Ga naar pagina of 79
MS337 Hand Held Scanner User's Manual.
.
T ABLE OF C ONTENTS Introduction ........................................................................................................ 1 Bar Code Configur ation Methods ..................................................................... 2 Scanner Oper ation .
MaxiCo de ....................................................................................................... 34 Aztec .............................................................................................................. 35 Postal .......
I NTRODUCTION Your new scanner has been configured at th e factory with default settings. Since many host systems have unique formats and protoco l requirements, Metrologic provides a wide range of conf i gurable features that may be selected using this bar code based con figurati on tool.
B AR C ODE C ONFIGURATION M ET HODS Single-Code Method Most features can be enabled or disabled using the Si ngle-Code Method . 1. Power up the scanner. 2. Scan the bar code for the desired feature. Observe a multi-toned, “save setting” beep that indicates th e configuration has been saved to NOVRAM.
S CANNER O PERATION Scan Buffers ³ 318000 * 1 Scan Buffer - The scanner will sca n one bar code in the scan field and not scan again u ntil the bar code is removed from the scan field for the duration of the same symbol time out. ³ 318010 2 Scan Buffers - The scanner will scan 2 bar codes in the scan field one time each.
S CANNER O PERATION Redundant Scans ³ 301100 * 0 Redundant Scans - Requires 1 good decode for a good scan . ³ 301110 1 Redundant Scan - Requires 2 consecutive decodes of the same bar code data for a good scan . ³ 301120 2 Redundant Scans - Requires 3 consecutive decodes of the same bar code data for a good scan .
S CANNER O PERATION Miscellaneous Decode Featu res ³ 118113 * Optional Same Symbol Check - Requires 1 different character bet ween successive bar codes to consider the bar code “new”. ³ 118103 Normal Same Symbol Check - Requires 3 different characters bet ween successive bar codes to consider the bar code “new”.
S CANNER O PERATION Beeper Options ³ 318575 * Normal Tone ³ 318565 Optional Tone 1 ³ 318555 Optional Tone 2 ³ 318545 Optional Tone 3 ³ 318535 Optional Tone 4 ³ 318525 Optional Tone 5 ³ 318515 O.
S CANNER O PERATION Beeper Options ³ 118407 * Ignore BEL Command ³ 116913 Enable Light Pen Tog gle During Beep - The scanner beeps and toggles th e light pen data line on a successful decode.
S CANNER O PERATION Communication Time Out Options ³ 118412 Enable Communications Ti me Out ³ 118402 * Disable Communications Time Out ³ 118413 * Beep Before Transmit ³ 118403 Beep After Transmit .
S CANNER O PERATION Host Scanner Commands ³ 118015 Enable D/E Disable Command. - The scanner will disable scanning after it receives an ASCII “D” from the host device. It will enable scanni ng when it receives an ASCII “E”. ³ 118005 * Disable D/E Disable.
S CANNER O PERATION Host Scanner Commands ³ 115916 Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 - The ID byte is transmitted as 3 bytes (i.
S CANNER O PERATION Presentation and Trigger Modes There are four configurable m odes fo r scanning: the presentation mode, the multi-try trigger mode, the continuous tri gger mode, and the single-trigger mode.
S CANNER O PERATION Omnidirectional and/or Linear Scanner Modes The unit can be configured to operate as an omnid irectional scanner, or a linear scanner, or a combination of both. Trigger and pres entation operations can be configured separately for Omnidirectional a nd Linear scan modes.
S CANNER O PERATION Omnidirectional and/or Linear Scanner Modes Enable Linear Only in Presentation Operations Disable Linear Only in Presentation Operations ³ 120211 ³ 120201 Enable 1D Linear Only i.
S CANNER O PERATION Aiming and Illumination Trigger and presentation o perations can be configured se parately to use the unit’s linear illumination as an aiming instrument .
S CANNER O PERATION Aiming and Illumination * Enable A uto Gain Disable Auto Gain ³ 125101 ³ 125111 Data Output * Enable Data Output Disable Data Output ³ 121205 ³ 121215 * Factory Default Configu.
S CANNER O PERATION Character Suppres sion Enable the Suppression of 1 Character * Disable the Suppression of 1 Character ³ 115111 ³ 115101 To suppress 1 character: 1. Scan the Enter/Exit Configuration Mode bar code, on page 2. 2. Scan the Enable the Suppression of 1 Character bar code.
S CANNER O PERATION Character Suppres sion (Code By tes 0 – 9) ³0 Code Byte 0 ³1 Code Byte 1 ³2 Code Byte 2 ³3 Code Byte 3 ³4 Code Byte 4 ³5 Code Byte 5 ³6 Code Byte 6 ³7 Code Byte 7 ³8 Cod.
S CANNER O PERATION Same Symbol Timeouts Retain Same Symbol Timeout on Trigger * Reset Same Symbol Timeout on Trigger ³ 120013 ³ 120003 The same-symbol timeout is not restarted when the trigger is pulled. The same-symbol timeout is restarted when the trigger is pulled.
C ODE T YPES AND D ECODE R ULES * Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code configuration meth od.
C ODE T YPES AND D ECODE R ULES C ODE 128 ³ 100113 * Enable Code 128 ³ 100103 Disable Code 128 ³ 100314 Enable UCC/EAN-128 ‘]C1’ Code Formatting ³ 100304 * Disable UCC/ EAN – 128 ‘]C1’ C.
C ODE T YPES AND D ECODE R ULES C ODE 39 ³ 100111 * Enab le Code 39 ³ 100101 Disable Code 39 ³ 100213 Enable MOD 43 Check Digit on Co de 39 - The scanner only scans Code 39 bar codes that have a valid Modulo 43 check digit.
C ODE T YPES AND D ECODE R ULES C ODE 39 ³ 100416 Enable ITF/Code 39 Filters ³ 100406 * Disable IT F/Code 39 Filters ³ 107715 Transmit MOD 43 Check Digit – with Self Service Library Code 3 9 ³ 1.
C ODE T YPES AND D ECODE R ULES 2 OF 5 C ODES ³ 100115 * Enable Interleaved 2 of 5 (ITF) ³ 100105 Disable Interleaved 2 of 5 (ITF) ³ 100310 Enable MOD 10 Check on ITF - T he scanner will only scan Interleaved 2 of 5 (ITF) bar codes that have a Modulo 10 check digit.
C ODE T YPES AND D ECODE R ULES 2 OF 5 C ODES ³ 100100 * Disable Standard 2 of 5 ³ 901500 ~ Standard 2 of 5 Sy mbol Length - To specify a minimum number of characters to be decoded, scan this bar code and the appropriate cod e bytes sequence located on p age 64 .
C ODE T YPES AND D ECODE R ULES C OD AB AR ³ 100114 * Enable Codabar ³ 100104 Disable Codabar ³ 100012 Enable Dual Field Codaba r ³ 100002 * Disable Dual Field Codaba r C ODE 93 ³ 100112 * Enable.
C ODE T YPES AND D ECODE R ULES C ODE 11 ³ 100013 Enable Code 11 ³ 100003 * Disable Co de 11 ³ 108005 * Check fo r 1 Code 11 Check Dig it ³ 108015 Check for 2 Code 11 Check Digits ³ 108004 * Do N.
C ODE T YPES AND D ECODE R ULES P LESSEY C ODES ³ 100212 Enable MSI Plessey ³ 100202 * Disable MSI Plessey ³ 200704 * No MSI Plessey Check Digit - Plessy bar codes will not be tested for a check digit. ³ 200734 Enable MSI Plessey MOD 10/10 Check Digi t - Test MSI Plessey bar codes for a 2 digit Modulo 10 check digit.
C ODE T YPES AND D ECODE R ULES ISBT C ODE 128 I MPLEMENTATION ³ 138417 Enable ISBT Code 128 ³ 138407 Disable ISBT Code 128 These bar codes are used to enable/d isable a special transmit mode as outline d in section 3.5.2 of the ISBT-128 Specification.
C ODE T YPES AND D ECODE R ULES RSS B AR C ODE I MPLEMENTATION ³ 100011 Double Border Required - When scanning RSS bar codes, it is recommended that double border requirements be enabled bec ause of the large spaces often found in RSS symbologies.
C ODE T YPES AND D ECODE R ULES RSS Limited Bar Codes ³ 100414 Enable RSS Limited ³ 100404 * Disable RSS Limited ³ 114903 * Transmit RSS Limited CD ³ 114913 Do Not Transmit RSS Limited CD ³ 114904 * Transmit RSS Limited Application ID - Application identifier “01” is transmitted by default.
C ODE T YPES AND D ECODE R ULES D AT A M AT RIX Enable Normal Color Data Matrix Decoding Enable Inverse Color Data Matrix Decoding ³ 200522 ³ 200512 Enable Normal and Inverse Color Data Matrix Decod.
C ODE T YPES AND D ECODE R ULES D AT A M AT RIX Enable Low-Contrast Data Matrix Decoding † * Disable Low-Contrast Data Matrix Decoding ³ 125417 Improves decoding † of low-contrast Data Matrix symbols.
C ODE T YPES AND D ECODE R ULES D AT A M AT RIX * Enable Data Matrix, Normal Size ³ 325402 The following bar codes improve deco ding of Data Matrix symbols when the length of a symbol size is small. To disable ei ther of these options scan the Enable Data Matrix Normal Size bar code above .
C ODE T YPES AND D ECODE R ULES QR C ODE Enable Normal Video QR Code Enable Inverse Video QR Code ³ 200612 ³ 200622 Enable Normal and Inverse QR Code * Disable QR Code ³ 200632 ³ 200602 2D structu.
C ODE T YPES AND D ECODE R ULES A ZTEC Enable Normal Video A ztec Dec oding * Disable Normal Video A ztec Dec oding ³ 100610 ³ 100600 Enable Inverse Video A ztec Dec oding * Disable Inverse Video A .
C ODE T YPES AND D ECODE R ULES A ZTEC Enable Aztec Structure Append Decoding * Disable Aztec Structu re Append Decoding ³ 100611 ³ 100601 When this feature is enabled, Aztec barcodes with a structured append header will be stored in the scanner’s memory buffer.
C ODE T YPES AND D ECODE R ULES P OSTAL Enable Australia Post * Disable Australia Pos t ³ 126217 ³ 126207 Enable Japan Post * Disable Japan Post ³ 126216 ³ 126206 Enable KIX Code * Disable KIX Cod.
C ODE T YPES AND D ECODE R ULES P OSTAL Enable PLANET Code * Disable PLANET Code ³ 126214 ³ 126204 Enable POSTNET Code * Disable POSTNET Post ³ 126213 ³ 126203 Enable B & B’ Fielded POSTNET .
C ODE T YPES AND D ECODE R ULES P OSTAL Enable UPU Decoding * Disable UPU Decoding ³ 126211 ³ 126201 Enable Royal Mail 4 Code * Disable Royal Mail 4 Code ³ 126210 ³ 126200 Enable Zero-FCC Australi.
C ODE T YPES AND D ECODE R ULES C ODABLOCK O PTIONS Enable Codablock A * Disable Codablock A ³ 126410 ³ 126400 Enable Codablock F * Disable Codablock F ³ 126411 ³ 126401 PDF O PTIONS Enable Transm.
C ODE T YPES AND D ECODE R ULES A DDITIONAL D ECODE F EATU RES ³ 100011 Enable Double Border Required / Large Intercharacter Space ³ 100001 * Disable Double Border Required / Large Intercharacter Space ³ 101115 Enable Small Border Required ³ 101105 * Disable Small Border ³ 901800 ~ Minimum Symbol Length - Single-line defau lt is 3.
C ODE T YPES AND D ECODE R ULES C ONFIGURABLE C ODE L ENGTHS There are seven bar code lock lengths avail able. Specific code types can be assigned to a lock length. While in programming mod e: 1. Scan the code lengt h lock #1 bar code 2. Scan the three code bytes that represe nt the code length (page 64 ) .
C ODE T YPES AND D ECODE R ULES C ONFIGURABLE C ODE L ENGTHS ³ 903000 ~ Code Length Lock #6 ³ 903100 ~ Code Type Lock #6 ³ 903200 ~ Code Length Lock #7.
C ODE T YPES AND D ECODE R ULES S UPPLEMENTS ³ 101217 Enable Two Digit S upplements ³ 101207 * Disable Two Digit Supp lements ³ 101212 * Enable Two Digit Redunda ncy - The scanner will scan the bar code plus the 2 digit add on t wice before accepting data.
C ODE T YPES AND D ECODE R ULES S UPPLEMENTS ³ 101417 Enable Bookland (978) Supp lement Required ³ 101407 * Disable Bookland (978) Supplemen t Required ³ 101314 Enable 977 (2 Digit) Supplement Requi red - The scanner will require a 2 digit suppleme nt to be scanned when an EAN-13 code beg ins with 977.
C ODE T YPES AND D ECODE R ULES S UPPLEMENTS ³ 101000 * Enab le 2 Digit Supplements w ith 37x, 43x, or UPC # System 5 ³ 101010 Disable 2 Digit Supplements with 37x, 43x, o r UPC # System 5 ³ 101001.
C ODE T YPES AND D ECODE R ULES S UPPLEMENTS ³ 101214 Enable Code ID’s with Supplements ³ 101204 * Disable Code ID’s with Supplements ³ 118406 * Beep Once on Supplements ³ 118416 Beep Twice on Su pplements ³ 101315 Enable ISBN Check Digit Transmissio n - Not available with all models.
P REFIXES /S UFFIXES Scan the Enter Configuration Mode b ar code before trying to set these features (see the Multi-Code M ethod on page 2 ). U SER C ONFIGURABLE P REFIXES , A LL D AT A ³ 903500 ~ Conf igurable Prefix Charact er #1 - A prefix ID can be added and assign ed for data transmission.
P REFIXES /S UFFIXES U SER C ONFIGURABLE ID C HAR ACTERS , C ODE S PECIFIC ³ 105507 * Use Configurable Cod e ID Bytes as Prefixes - User configured, code specific ID bytes are transmitted before the data. If using pr efixes, user configured suffixes cannot be used.
P REFIXES /S UFFIXES U SER C ONFIGURABLE ID C HARACTERS , C ODE S PECI FIC ‡ Enter configuration mode then scan this bar c ode followed by the three code byte bar codes (page 64 ) that represent a unique ID character to be associated with this bar code type.
P REFIXES /S UFFIXES S TA ND A RD P REFIX C HA RAC TERS ³ 116615 Enable STX Prefix - The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code.
P REFIXES /S UFFIXES S TA ND A RD P REFIX C HA RAC TERS ³ 107916 Enable SANYO ID Characters ³ 107906 * Disable SANYO ID Characters ³ 105512 Enable Manufacturer ID Prefix ³ 105502 * Disable Manufac.
P REFIXES /S UFFIXES S TA ND A RD S UFFIX C HARACTERS ³ 116613 * Enable CR Suffix - The scanner transmits a carriage return after each bar code. ³ 116603 Disable CR Suffix. ³ 116612 * Enable LF Suffix - The scanner transmits a line feed after each bar code.
P REFIXES /S UFFIXES L ONGITUDIN AL R EDUNDANCY C HECK A Longitudinal Redund ancy Check (LRC) is an error checki ng character that is calculated across a sequence of data char acters. It is determined by eXclusive ORing (XOR) the characters to be checked, starting with an initial value of 00H.
P REFIXES /S UFFIXES C HA RAC TER R EPL ACEMENTS To replace a character: 1. Scan the enter/exit configuration mode bar c ode (page 2 ). 2. Scan the character to replace code (shown below). 3. Scan the ASCII code byte value of the char acter you wish to replace (refer to the ASCII Reference Table in the Code B yte Usage section of this manual).
P REFIXES /S UFFIXES U SER C ONFIGURABLE S UFFIXES , A LL D AT A Note: Scan the Enter /Exit Configuration mode code before trying to set this feature. Refer to Multi-Code Method on page 2 . ³ 904500 ~ Conf igurable Suffix Charact er #1 - A suffix ID can be added and assigned for d ata transmission.
P REFIXES /S UFFIXES S PECIAL F ORMATS ³ 107914 Enable SINEKO Mode ³ 107904 * Disable SINEKO Mode ³ 116711 Enable Newcode Formatting Mode A ³ 116701 * Disable Newcode Formatting Mode A ³ 116710 E.
C ODE F ORMATTING UPC/EAN F ORMA TTING ³ 107517 * Transmit UPC-A Check Digit ³ 107507 Do Not Transmit UPC- A Check Digit ³ 107516 Transmit UPC-E Check Digit ³ 107506 * Do Not Transmit UPC-E Check Digit ³ 107515 Expand UPC-E to 12 Digits - Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes.
C ODE F ORMATTING ³ 107512 Convert EAN-8 to EAN-13 - The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13. ³ 107502 * Do Not Convert EAN-8 to EAN-13 ³ 107511 * Transm.
C ODE F ORMATTING C OD AB AR F ORMATTING ³ 107717 Transmit Codabar Start/Stop Character s - Transmits Codabar’s Start/stop characters before and after each bar code. ³ 107707 * Do Not Transmit Codabar Start/Stop ³ 107716 Enable CLSI Editing - Works only with 14 digit Codabar type lengths.
C ODE F ORMATTING C ODE 39 F ORM ATTING ³ 107715 Transmit Mod 43 Check Digi t on Code 39 - This feature works in conjunction with Mod 43 Check Digit on Code 39 option, page 21 .
C ODE F ORMATTING P LESSEY ³ 107816 Transmit UK Plessey Check Digi t - The scanner will transmit UK Plessey Check Digit characters and must be used with the UK Plessey option.
USB * Enable USB Keyboard Emulation Mode Enable USB Serial Mode ³ 117817 Enable Barcode ID ³ 117807 Disable Barcode ID ³ 119817 Enable USB Reserve Code #1 ³ 119807 Disable USB Reserve Code #1 ³ 9.
C ODE B YTES U SAGE The features that use t hese code bytes for configuration re quire that the scanner be in Configuration Mode . T he Enter/Exit Configuration Mode bar code (on page 2 ) must be scanned before starti ng the configurati on cycle.
C ODE B YTES U SAGE R ESERVED C ODES ³ 999988 ~ Enable Reserved Code ³ 999987 ~ Disable Reserved Code C ODE T YPE T ABL E DDD (Prefix) (Dec) (Hex) Comment (Symbology) 002 2 02h UPC-E 003 3 03h EAN-8.
C ODE B YTES U SAGE C ODE T YPE T ABL E DDD (Prefix) (Dec) (Hex) Comment (Symbology) 094 94 5Eh Matrix 2 of 5 095 95 5F h Telepen 096 96 60h UK Plessey 097 97 61h Airline 2 of 5 (13 digit) 098 98 62h .
C ODE B YTES U SAGE C ODE T YPE T ABL E DDD (Prefix) (Dec) (Hex) Comment (Symbology) 164 164 A4h OCR Price Field Template 165 165 A5h OCR MICR-E13B Template 166 166 A6h OCR Visa A Upper line template .
C ODE B YTES U SAGE ASCII R EFERENCE T AB LE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 000 NUL @ 01 001 SOH A 02 002 ST X B 03 003 ETX C 04 004 EOT D 05 005 ENQ E 06 0.
C ODE B YTES U SAGE ASCII R EFERENCE T AB LE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 1D 029 GS ^ 1E 030 RS _ 1F 031 US space,blank 20 032 SP 21 033 ! 22 034 “ 23 035 # 24 036 $ 25 037 % 26 038 & 27 039 ‘ apostrophe 28 040 ( 29 041 ) 2A 042 * 2B 043 + 2C 044 , comma 2D 045 - minus 2E 046 .
C ODE B YTES U SAGE ASCII R EFERENCE T AB L E HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 3C 060 < less than 3D 061 + 3E 062 > greater than 3F 063 ? 40 064 @ shift P .
C ODE B YTES U SAGE ASCII R EFERENCE T AB L E HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 5A 090 Z 5B 091 [ shift K 5C 092 shift L 5D 093 ] shift M 5E 094 ^ à,shift N 5F .
C ODE B YTES U SAGE ASCII R EFERENCE T AB L E HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 79 121 y 7A 122 z 7B 123 { 7C 124 | vertical slas h 7D 125 } alt mode 7E 126 ~ (al.
C ODE B YTES U SAGE E XTENDED K EY C ODE R EFERENCE T AB LE Key At S ca n Code PS2 Scan Code 3151 Prefix/Suffix Value Hex = Decimal F5 03H 3F H 27H 94H = 148 F6 0BH 40H 2FH 95H = 149 F7 83H 41H 37H 96.
C ODE B YTES U SAGE E XTENDED K EY C ODE R EFERENCE T AB LE Erase EOF 6DH C4H = 196 Send – Make Only 58H C5H = 197 *Example: 1st Configurable Prefix = 174 2nd Configurable Prefix = 065 Scanner will .
N EED T O S TART O VER ? Scan the Recall Default bar code. T his will erase all previous settings and return the scanner to its default communication pro tocol.
Een belangrijk punt na aankoop van elk apparaat Unitech MS337 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Unitech MS337 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Unitech MS337 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Unitech MS337 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Unitech MS337 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Unitech MS337 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Unitech MS337 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Unitech MS337 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.