Gebruiksaanwijzing /service van het product 1537G van de fabrikant United States Stove
Ga naar pagina of 24
1 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U Model 1537G OWNERS MANUAL SOLID FUEL W ARM AIR FURNA CE CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATI.
2 NO TE: Y OUR UNIT MUST BE INST ALLED BY A QU ALIFIED FURNA CE INST ALLER. Y ou've purchased one of America's Finest W ood and Coal Burning Furnaces. By heating with wood and coal you're helping CONSER VE AMERICA'S ENERGY! W ood is our Renewable Energy Resource.
3 CAUTION! CLEANOUT OF THE HEA T EXCHANGER, FLUE PIPE, CHIMNEY , AND DRAFT INDUCER (IF USED), IS ESPECIALL Y IMPORT ANT A T THE END OF THE HEA TING SEASON T O MINIMIZE CORROSION DURING THE SUMMER MONTHS, CA USED BY ACCUMULA TED ASH. Y our Fur nace has the follo wing labels .
4 1. Check your local codes. The installation must comply with their rulings. 2. Do not install this furnace in a mobile home or trailer. 3. Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building.
5 Y our CLAYTON Furnace is designed to be a supplemental or central heating source for your home. This Solid Fuel Furnace may be installed in conjunction with a properly operating central furnace that.
6 32-1/8" 1-3/4" 9" 33-7/8" 49-1/8" 24-1/16" 40-11/16" Figure 1B 1400/1500 DIMENSIONS OF FURNACE FIGURE 1 1537G.
7 LOCA TING THE FURNA CE 1. The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
8 10' 2' MIN. 3' MIN. 6" CHIMNEY CONNECTOR 6" ELBOW 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) REFER TO CHIMNEY MANUFACTURER'S INSTRUCTIONS AND PARTS.
9 RULES FOR CONNECT OR PIPE INST ALLA TION 1. The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chim- ney connectors and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any condensation in the flue to run back into the furnace.
10 ASSEMBL Y OF FURNA CE Your furnace requires the following items to be assembled or installed by the service person: Feed Door Pull Handle Feed Door Locking Handle Blower(s) and Blower Controls Elec.
11 LOAD FAN LINE LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN "OFF" INDICATOR FAN "ON" INDICATOR LIMIT INDICATOR Honeywell LIMIT SWITCH R1 R2 G B W 110 VAC, 60 HZ.
12 INST ALLA TION Please see all methods of Installation in Appendix at the rear of this booklet. Pipe to combustible: Sides: 21" Back: 18" The installation must be made only on a noncombustible floor.
13 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE Figure 12 P OWER F AILURE I NSTRUCTIONS : Operation after loss of power-- 1. Remove filter if provided 2. Do not expect to keep home at normal temperatures. 3. Do not load fuel above bottom of feed door.
14 CAUTION GASES THAT ARE DRIVEN FROM FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DE- SIGNED FOR THERMOSTATIC OPERATION.
15 SER VICE HINTS Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or excessive build-up of water or creosote in the chimney are warnings that the chimney is not functioning properly. Correct the problem before using furnace.
16 MODEL 1537G REPAIR PARTS.
17 KEY PART# DESCRIPTION QTY. 1 68215 FIREBOX WELDMENT 1 2 40246 FLUE CO LLAR 1 3 88032 FLUE CO LLAR GASKET 1 4 23458 CABINET BOTTOM 1 5 40258 BACK LI NE R 1 6 40256 SHAKER FRAME 2 7 40257 SHAKER GRAT.
18 COLD AIR DUCT 6" PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation Fig. 16-1 (U.S. ONLY) Add-On Installation COLD AIR DUCT 6" PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS/OIL/ELECTRIC FURNACE 8" PIPE Fig.
19 (U.S. ONLY) COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX APPENDIX INSTALLATION A.
20 INSTALLATION B INSTALLATION C COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM ELBOW PLENUM TOP (OPTIONAL) (U.
21 2" MINIMUM CLEARANCE DUCT WORK 11 PCS (OPTIONAL PLENUM FAN CONTROL LOCATION) FURNACE PLENUM EXISTING FURNACE ANTI-BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION E BAFFLE (U.
22 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2" MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR .
23 2" MINIMUM CLEARANCE EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE INSTALLATION H EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE (TOP VIEW) (FRONT VIEW).
24 1. Smoking when feed door a) Insufficient Draft. a) Set Thermostat higher. is open. b) Clogged chimney or chimney b) Clean Chimney. connector. c) Add raincap to chimney. c) Down draft in chimney. 2. Furnace does not heat. a) Wood not seasoned and dry.
Een belangrijk punt na aankoop van elk apparaat United States Stove 1537G (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove 1537G heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove 1537G vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove 1537G leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove 1537G krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove 1537G bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove 1537G kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove 1537G . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.