1 C O M P A N Y U N I T E D S T A T E S S T O V E C S S U Models: 1537M 1557M OWNERS MANUAL SOLID FUEL WARM AIR FURNACE CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR O.
2 NOTE: YOUR UNIT MUST BE INSTALLED BY A QUALIFIED FURNACE INSTALLER. You've purchased one of America's Finest Wood and Coal Burning Furnaces. By heating with wood and coal you're helping CONSERVE AMERICA'S ENERGY! Wood is our Renewable Energy Resource.
3 CAUTION! CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY, AND DRAFT INDUCER (IF USED), IS ESPECIALLY IMPORTANT AT THE END OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE SUMMER MONTHS, CAUSED BY ACCUMULATED ASH. Your Furnace has the following labels.
4 1 . Check your local codes. The installation must comply with their rulings. 2 . Do not install this furnace in a mobile home or trailer. 3 . Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building.
5 Y our Hotblast Furnace is designed to be a supplemental or central heating source for your home. This Solid Fuel Furnace may be installed in conjunction with a properly operating central furnace tha.
6 DIMENSIONS OF FURNACE FIGURE 1 1537M.
7 LOCATING THE FURNACE 1. The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
8 CHIMNEY CONNECTION Fig. 4 MASONRY CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the furnace. See page 4, item 5. Look at Fig. 4. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown.
9 RULES FOR CONNECTOR PIPE INSTALLATION 1. The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chim- ney connectors and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any condensation in the flue to run back into the furnace.
10 ASSEMBLY OF FURNACE Your furnace requires the following items to be assembled or installed by the service person: Feed Door Pull Handle Feed Door Locking Handle Blower(s) and Blower Controls Electr.
11 FIGURE 11.
12 INSTALLATION Please see all methods of Installation in Appendix at the rear of this booklet. Pipe to combustible: Sides: 21" Back: 18" The installation must be made only on a non- combustible floor.
13 2" MI N. AI R SPAC E REQUIRED BY CO DE PLENUM TO CEILING 6" MI N. CENTRAL FURN ACE PLENUM Figure 12 P OWER F AILURE I NSTRUCTIONS : Operation after loss of power-- 1. Remove filter if provided 2. Do not expect to keep home at normal temperatures.
14 CAUTION GASES THAT ARE DRIVEN FROM FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DE- SIGNED FOR THERMOSTATIC OPERATION.
15 SERVICE HINTS Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or excessive build-up of water or creosote in the chimney are warnings that the chimney is not functioning properly. Correct the problem before using furnace.
16 MODEL 1537M REPAIR PARTS.
17 PARTS LIST MODEL 1537M (SEE DIAGRAM, PAGE 16) KEY PART # DESCRIPTION QTY. 1 23458G Cabinet Bottom 1 2 23461G Cabinet Side (Left & Right) 2 3 88032 Flue Collar Gasket 1 4 40246 Flue Collar 1 5 2.
18 MODEL 1557M REPAIR PARTS.
19 PARTS LIST MODEL 1557M (SEE DIAGRAM, PAGE 18) KEY PART # DESCRIPTION QTY. 1 69509 Firebox Weldment 1 2 25467G Cabinet Side (Left & Right) 2 3 88032 Flue Collar Gasket 1 4 40246 Flue Collar 1 5 .
20 COLD AIR DUC T 6" PIPE DAMPER PIPE CONNE CT OR FURNA CE OPTION AL 11 RPT 90° EL BOW FIGURE 15-1 FIGURE 15-1 6" PI PE COLD AI R DUCT 8" PI PE FURN ACE EXISTIN G GAS/O IL/ELECT RIC FU.
21 APPENDIX INSTALLATION - A (U.S. ONLY) TO EXISTIN G DUCT WOR K WARM A IR EXISTING FU RNAC E SOLID FU EL FURN ACE FILTER BO X COLD AI R RETURN.
22 TO EXIS TING DUCT WO RK WARM AI R EXISTING FURNACE SOLID FUEL FURNAC E FILTE R BOX COLD AIR RETURN PLENUM TOP (OPTIO NAL) INSTALLATION - B (U.S. ONLY) INSTALLATION - C (U.
23 COLD A IR RETURN 2" MIN IMUIM CLEARANCE SOLID FU EL FURNACE DUCT WORK BAFFLE FUR NAC E PL ENUM EXISTIN G FURNACE EXISTING FURNACE FURNACE PLEN UM CLEARANCE 2" MIN IMUIM WORK DUCT RETURN COLD AIR FURNACE SOLID FU EL 11 PCS (OPTIONAL PLEN UM FAN CONT ROL LOC ATION ) ANTI-BAC KDRAFT FLAPPE R INSTALLATION - D (U.
24 SOLID FUEL FURNACE COLD AIR RETURN TO FILTER BOX 2" MINIMUM CLEARANCE DUCT WORK CENT RAL FURNACE INSTALLATION SOLID FUEL FURNACE EXISTING FURNACE FURNACE PLENUM COLD AIR RETURN 2" MINIMUM.
25 EXI ST ING OI L, ELE CT RIC , O R GAS FURNACE SOLID FUEL FURNACE 2" MINIM UM CLEARANCE SOLID FUEL FURNACE EXISTING OIL, ELECTRIC, OR GAS FURNACE INSTALLATION - H.
26 1. Smoking when feed door a ) Insufficient Draft. a ) Set Thermostat higher. is open. b ) Clogged chimney or chimney b ) Clean Chimney. connector. c) Down draft in chimney. c) Add raincap to chimney. 2. Furnace does not heat. a ) Wood not seasoned and dry.
27 NOTES.
28 THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SER- VICE FROM YOUR AMERICAN HARVEST, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Een belangrijk punt na aankoop van elk apparaat United States Stove 1557M (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove 1557M heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove 1557M vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove 1557M leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove 1557M krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove 1557M bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove 1557M kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove 1557M . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.