1 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• C O M P A N Y U N I T E D S T A T E S S T O V E C S S U CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE FUR.
2 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• TOOLS AND MATERIALS NEEDED TOOLS Pencil 6 Foot Folding Rule or Tape Tin Snips Drill, Hand or Electric Drill Bit (For Sheet Metal Screws) 1/8" Dia.
3 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CAUTION Your Furnace has the following labels. Read and obey all labels. REFER TO MARKINGS ON THE APPLIANCE FOR ADDITIONAL INFORMATION.
4 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage. Check your local codes. This installation must comply with their rulings.
5 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Your Ashley Furnace is designed to be a supplemental or central heating source for your home. This solid fuel furnace may be installed in conjunction wi.
6 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF DIMENSIONS FIG. 1.
7 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• 1. 2. 3. 4. FIG. 3 The furnace should be located in the same room as the central system and as close as possible, but no closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
8 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• LISTED FACTORY BUILT CHIMNEY Carefully follow chimney manufacturer's instructions. Use only a Listed Residential Type or Building Heating Appliance Chimney. If your chimney starts at the ceiling (Fig.
9 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• RULES FOR CONNECTOR PIPE INSTALLATION FIG. 6 The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chimney connector and elbow with the CRIMPED END TOWARD THE FURNACE.
10 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall.
11 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MINIMUM 12 IN. TO COMBUSTIBLES PART A, FIGURE 8 (FIGURE 8 CONTINUED ON NEXT PAGE) Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall.
12 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• PART B FIGURE 8 - (FIGURE 8 CONTIN- UED) AIR SPACE 9 IN. MINIMUM FACTORY-BUILT CHIMNEY LENGTH MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
13 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• BLOWER & COMPONENT ASSEMBLY - FIG. 9 JUNCTION BOX MOUNTING BRACKET 1. Attach the Fan Limit Control Bracket to the rear of the furnace with four(4) of the #10 x 1/2 Tek screws provided in the parts bag.
14 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF WIRING DIAGRAM - FIG. 11 WIRE COLOR CODE G- GREEN- GROUND B- BLACK- POWER SUPPLY W- WHITE- POWER SUPPLY R1- WHITE- FAN CONTROL R2- BLACK- FAN CONTROL M1- BLACK- BLOWER MOTOR M2- WHITE- BLOWER MOTOR Fig.
15 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Please see all methods of Installation in Appendix at the rear of this booklet. This is a furnace, not a free standing stove. You must direct heated air from 12" outlet away from the furnace, or it will not function properly.
16 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• POWER FAILURE INSTRUCTIONS: Operation after loss of power Remove filter if provided. Do not expect to keep home at normal temperatures. Do not load fuel above bottom of feed door. Set Fuel door and Ash door spin draft maximum closed per the factory installed stops.
17 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CENTRAL INSTALLATION (U.S. & CANADA) (FIGURE 12) ADD-ON INSTALLATION (U.S. ONLY) (FIGURE 13).
18 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• ALTERNATIVE PARALLEL INSTALLATION WIRING DIAGRAM - FIG. 14 TO GAS/OIL/ELECTRIC TRANSFORMER HOTBLAST COMBINATION CONTROL LIMIT FAN JUMPER IN H H POWER S.
19 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CAUTION GASES THAT ARE DRIVEN BY FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DESIGNED FOR THERMO- STATIC OPERATION.
20 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or exces- sive build-up of water or creosote in the chimney would keep it from functioning properly.
21 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF - PARTS.
22 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF - PARTS LIST KEY PART NO. DESCRIPTION QTY. 1 69356 Firebox Weldment 1 2 88032 Flue Collar Gasket 1 3 40246 Flue Collar 1 4 25102R Cabinet Si.
23 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION A NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
24 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION B NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
25 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION C NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
26 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION D (U.S. ONLY) INSTALLATION E (U. S. ONLY).
27 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION F INSTALLATION G.
28 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• 1. Smoking when feed door is open. 2. Furnace does not heat. 3. Blower does not run. 4. No air from registers - fan running. 5. Air from registers is not hot. 6. Blower runs too long. 7. Blower does not run long enough.
29 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• NOTES.
30 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• NOTES.
31 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• TYPE WEIGHT PER CORD EFFICIENCY SPLITS MILLIONS (LBS. CU. FT., DRY) RANKING BTU's/CORD Hickory 63 4500 1. 0 Well 31.5 White Oak 48 4100 . 9 Fair 28.6 Red Oak 46 3900 . 8 Fair 27.4 Beech 45 3800 . 7 Hard 26.
32 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Een belangrijk punt na aankoop van elk apparaat United States Stove 22AF (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove 22AF heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove 22AF vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove 22AF leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove 22AF krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove 22AF bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove 22AF kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove 22AF . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.