Gebruiksaanwijzing /service van het product 6300C van de fabrikant United States Stove
Ga naar pagina of 24
USSC 1.
2 USSC T ABLE OF CONTENTS .............................................................................................. 2 SAFETY PRECAUTIONS ........................................................................................... 3 SPECIFICA TIONS .
USSC 3 Safety Precautions IMPORT ANT : Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury , or even death. Proper installation of this furnace is crucial for safe and efficient operation.
4 USSC Specifications Input BTU/Hr 1 50,000 to 105,000 BTU/hr . Heating Capacity 2 1,200 - 2,800 sq. ft. Fuel Burn Rate 3 5.0 - 13.0 lbs./hr . Burn T ime (lowest setting) 70 hours continuous Hopper Capacity 320 lbs Heating S pecifications Height 43-1/8 in.
USSC 5 Fuel Considerations SHELLED CORN (Dry , preferably corn with 1 1% or less moisture content) • • • • • • • Optimum moisture content of corn should be 1 1% or less. Wet corn will rapidly deteriorate furnace components, reduce efficiency and void all warranties.
6 USSC INST ALLA TION OPTIONS Read this entire manual before you inst all and use your Multi-Fuel Furnace. Failure to follow instructions may result in property damage, bodily injury , or even death! .
USSC 7 Installation CLEARANCES NOTE: Distance on the left-hand side of y our Multi-Fuel Furnace is set at 24 inches for suitable access to the control panel and for fuel loading.
8 USSC Installation VENTING REQUIREMENTS Inst all vent at clearances specified by the vent manufacturer . Do not connect the pellet vent to a vent serving any other appliance or furnace. Do not inst all a flue damper in the exhaust venting system of this unit.
USSC 9 Installation VENT TERMINA TION CLEARANCES: A ----- Minimum 4-foot clearance below or beside any door or window that opens. B ----- Minimum 1-foot clearance above any door or window that opens. C ----- Minimum 3-foot clearance from any adjacent building.
10 USSC Installation THROUGH THE W ALL INST ALLA TION (RECOMMENDED INST ALLA TION) T o vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter . If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall.
USSC 11 Installation PRIMAR Y FURNACE SECONDAR Y (ADD-ON) FURNACE When installed as a seondary furnace, a Duct Damper must be inst alled between the air discharge of the 6300 furnace and the primary (Gas, Electric, etc.). This duct damper prevent s the air from the primary furnace from back flowing to the secondary furnace.
12 USSC Component Location.
USSC 13.
14 USSC LIGHTING INSTRUCTIONS CAUTION: DO NOT USE CHEMICALS OR FLUIDS TO ST ART THE FIRE HOT WHILE IN OPERA TION. KEEP CHILDREN, CLOTHING AND FURNITURE AW A Y . CONT ACT MA Y CAUSE SKIN BURNS. Before lighting your heater for the first time, make sure that all items are out of the hopper , ash pan and firebox area.
USSC 15 Maintenance Operation DAIL Y OPERA TION The hopper and furnace top will be hot during operation; therefore, you should always use some type of hand protection when refueling your furnace. Never place your hand near the auger while the furnace is in operation.
16 USSC INTERIOR CHAMBERS Open the Ash Cleanouts and scrap all ash into the ash p an. Open the damper and allow the ashes to fall into the ash pan. The damper may need to be slide in and out several times to clear any ash build-up. This may need to be done daily depending on fuel consumption.
USSC 17 Parts Diagram.
18 USSC Parts List 1 5 9 8 10 12 7 4 6 11 3 2 Item Part No. Title Qt y . 1 25507 Feed Door 1 2 25492 Handle, Door 1 3 83506 3/8 x 1 1/4 Roll Pin 1 4 891053 Door Glass w/o Logo 1 5 88066 5/8” Rope Gasket 4.5 ft 6 88087 Glass Gasket (1 x 1 3/16) 3 ft 7 25520 Bottom Glass Ret ainer 1 8 25521 T op Glass Retainer 1 P ARTS LIST Item Part No.
USSC 19 Wiring Diagram.
20 USSC T rouble Shooting PROBLEM CAUSE: Not enough combustion air; Fuel has too much moisture. Viewing window becoming black shortly af ter start-up. • Adjust the air damper to a more open position. • Use a fuel with less moisture content PROBLEM CAUSE: Not enough combustion air; Fuel has too much moisture.
USSC 21 Err or Codes Below is a chart describing the Error Codes that might be displayed if an error occurs with your furnace. Error Code Err1 Err2 Err3 Err4 Err5 Err6 Err7 Err8 Error Descrption The high limit temperature sensor has tripped. Furnace ran out of fuel during normal operation.
22 USSC Notes.
USSC 23 Notes.
24 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR KING OR ASHLEY, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Een belangrijk punt na aankoop van elk apparaat United States Stove 6300C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove 6300C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove 6300C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove 6300C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove 6300C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove 6300C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove 6300C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove 6300C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.