CAC 1 Installation, Operation and Maintenance Instructions TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ................................................................................................... .............................................
2 CAC FIGURE 1 - MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 2 - MINIMUM CLEARANCES TO COMBUSTIBLES When selecting a location for the heater, be sure attention is given to the following considerations: 1.
CAC 3 FIGURE 3 - MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 - MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW.
4 CAC FIGURE 5 - FLOOR PROTECTION FLOOR PROTECTION This heater has been designed to prevent excessive temperatures on the floor beneath the heater. It is important, however, tha t a combustible floor be protected by a 3/8 inch minimum thick noncombustible inorganic millboard having a thermal conductivity of K=0.
CAC 5 There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall.
6 CAC MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. CHIMNEY LENGTH FLUSH WITH INSIDE OF FLUE NONSOLUBLE REFACTORY CEMENT MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 CHIMNEY CONNECTOR TO HEATER MINIMUM CLEARANCE 9 IN.
CAC 7 SHEET STEEL SUPPORTS CHIMNEY SECTION CHIMNEY CONNECTOR AIR SPACE 2 IN. TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL. PART C FIGURE 5 PART D FIGURE 5 MINIMUM CLEARANCE 2 IN. ALL AROUND CHIMNEY THIMBLE 1 IN. AIR SPACE TO CHIMNEY LENGTH MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS (24 GAUGE MIN.
8 CAC FIGURE 8 - CONNECTING HEATER’S CHIMNEY CONNECTOR TO MASONRY CHIMNEY WHEN CHIMNEY CON- NECTOR DOES NOT HAVE TO PASS THROUGH A COMBUSTIBLE WALL CAUTION: IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS.
CAC 9 Two common types of clearance reductions systems use sheet metal with a thickness of 28 gauge (galvanized steel, aluminum, copper) or a 3-1/2 inch (4 inch thick nominal) thick masonry wall. Either of these materials must be spaced out 1 inch from th e combustible surfaces.
10 CAC FIGURE 9 - HEATER OPERATION INFORMATION HEATER OPERATION IMPORTANT: DO NOT USE THE HEATER UNTIL A PROFESSIONAL INSPECTION HAS BEEN MADE OF THE ENTIRE INSTALLATION BY YOUR LOCAL FIRE DEPARTMENT, FIRE MARSHAL OR BUILDING CODE INSPEC- TOR.
CAC 11 FIGURE 10 - OPENING AND CLOSING FUEL FEED DOOR 5. When the wood is burning briskly, add additional kindling as required to establish a good kindling fire. 6. When the kindling fire has been established and is burning briskly, cover it with a thin layer of coal.
12 CAC 8. DO NOT OVERFIRE THE HEATER. If any part of the heater or chimney connector becomes red hot, the heater is being overfired. Immediately turn the heater’s thermostat to “LO” and keep the fuel feed door and ash removal door closed until the heater cools.
CAC 13 Ashes should never be placed in wooden or plastic containers, or in paper or plastic bags, no matter how long the fire has been out. Coals have been known to stay hot for several days when embedded in ashes.
14 CAC FIGURE 11 - CHIMNEY HEIGHT REQUIREMENTS WHAT TO DO IF THE HEATER SMOKES OR BURNS POORLY OR EXCESSIVE CREOSOTE ACCUMULATES IN THE CHIMNEY 1. Open a window slightly to see if the conditions improve.
CAC 15 QUICK REFERENCE TO THE MOST COMMON SOLUTIONS FOR THE MOST COMMON HEATER OPERATIONAL PROBLEMS 1. Symptom: Fire rate does not increase with thermostat open, smoke spilling from feed door when tending fire or backpuffing. Check for: a. Chimney connector pushed too far into a masonry chimney thimble restricting draft.
16 CAC 25 . Do assemble the chimney connector so that moisture that accumulates within the chimney will flow back toward the heater. 26. Do remove the ashes from the heater regularly. 27. Do set the thermostat on “HI” and allow the heater to burn for approximately 15 minutes after fresh coal is added before reducing the thermostat setting.
CAC 17 FIGURE 12 ILLUSTRATION OF REPAIR PARTS. SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS..
18 CAC SEE FIGURE 12 FOR ILLUSTRATION OF PARTS CUSTOMER NOTE: IN ADDI- TION TO THE REPAIR PARTS, KITS INCLUDE ANY RE- PLACEMENT FASTENERS WHICH WILL MOST LIKELY BE NEEDED TO INSTALL THE REPAIR PART. N/S = Not Shown K EY QTY. CA C NO . PART NAME Per Unit PART NO.
Een belangrijk punt na aankoop van elk apparaat United States Stove DR6 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen United States Stove DR6 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens United States Stove DR6 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding United States Stove DR6 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over United States Stove DR6 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van United States Stove DR6 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de United States Stove DR6 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met United States Stove DR6 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.