DO NOT ST ORE OR USE GASOLINE OR OTHER FLAM- MABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
2 Dutchwest Direct V ent / Natur al V ent Gas Heater 30001935 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 General Information The Dutchwest Direct V ent/Natural V ent Room Heater , Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.
4 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Dutchwest Direct V ent / Natural V ent Dimensions C L V alve Inlet 23" (584mm) 6 " (172mm) 24 " (622mm) .
5 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude.
6 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natural V ent ST128b Stardance flue centerline 9/28/00 djt C L C L B D C A ST128c Stove Clearances A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines C: 15 ¹⁄₂ ” (395 mm) D: 9” (229 mm) Fig.
7 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 2465 Nat Millivolt 28,000 20,000 2466 Prop Millivolt 28,000 19,000 Gas Specifications Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minimum 5.
8 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ertical T ermination - Direct V ent ONL Y A vertical vent system must terminate no less than 8’ (2.
9 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • This unit does not require any opening for in- spection of vent pipe.
10 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
1 1 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fig. 10 T ermination clearances. V enting Requirements - Natural V ent Only FP567 NVBR/NVBC VENTING RUNS 11/12/97 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height.
12 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof.
13 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, V enting System Assembly . 1.
14 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting System Assembly - Direct V ent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly .
15 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the V ent Adapter Pipe (Simpson Dura-V ent Components) 1. Install the Restrictor Plate. Consult the ‘V ent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed.
16 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 For DuraV ent pipe only: Install vent pipe by align- ing the locking system together , sliding the pipes together and twisting clockwise. • Install 90° elbow . T wist lock as before. • Slide the wall plate over horizontal run before at - taching the horizontal run to the elbow .
17 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ent T ermination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level.
18 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints.
19 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Attach the first section of venting to the draft hood. De- pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
20 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFP A 54. Since some municipalities have additional local codes, be sure to consult your local authority .
21 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open.
22 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
23 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 45. Follow the lighting instructions on Page 25 exactly .
24 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
25 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 T roubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. W ARNING: REMOVE THE GLASS P ANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
26 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction.
27 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Pilot Orifice Conversion 1. Locate pilot. (Fig. 49) 2. Replace pilot orifice. Pilot T ype 1 • Remove pilot hood by lifting up. (Fig. 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver- sion.
28 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 21. Replace burner . Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base.
29 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Maintenance Y our Dutchwest Gas Heater will provide years of ser - vice with minimal upkeep.
30 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
31 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Wiring Diagrams OFF ON Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124b on/off/s witch wiring 1.
32 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 1a 1b 1c 2 10 12 1 1 PILOT ON OFF PILOT ADJ L O H I 23 27 28 32 CEMENT 34 35 1 3 4 6 7 5 8 13a,b 15a 17 19 14 18 20 21 15b 16a,b, c,d 25 2.
33 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Ref. Description Dutchwest Dutchwest Direct V ent / Natural V ent Gas Heater Models 2465, 2466 (continued) 10. Glass, DV25 1601691 1 1. Glass Frame Assembly - SDV30 30000127 12. Gasket, Glass - Med.
34 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture.
35 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 LIMITED LIFETIME W ARRANTY PRODUCT COVERED BY THIS W ARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner .
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .
Een belangrijk punt na aankoop van elk apparaat Vermont Casting 2466 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Casting 2466 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Casting 2466 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Casting 2466 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Casting 2466 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Casting 2466 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Casting 2466 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Casting 2466 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.